RESUMO
BACKGROUND: Transcatheter pulmonary valve replacement (TPVR) with the self-expanding Harmony valve (Medtronic) is an emerging treatment for patients with native or surgically repaired right ventricular outflow tract (RVOT) pulmonary regurgitation (PR). Limited data are available since U.S. Food and Drug Administration approval in 2021. OBJECTIVES: In this study, the authors sought to evaluate the safety and short-term effectiveness of self-expanding TPVR in a real-world experience. METHODS: This was a multicenter registry study of consecutive patients with native RVOT PR who underwent TPVR through April 30, 2022, at 11 U.S. CENTERS: The primary outcome was a composite of hemodynamic dysfunction (PR greater than mild and RVOT mean gradient >30 mm Hg) and RVOT reintervention. RESULTS: A total of 243 patients underwent TPVR at a median age of 31 years (Q1-Q3: 19-45 years). Cardiac diagnoses were tetralogy of Fallot (71%), valvular pulmonary stenosis (21%), and other (8%). Acute technical success was achieved in all but 1 case. Procedural serious adverse events occurred in 4% of cases, with no device embolization or death. Hospital length of stay was 1 day in 86% of patients. Ventricular arrhythmia prompting treatment occurred in 19% of cases. At a median follow-up of 13 months (Q1-Q3: 8-19 months), 98% of patients had acceptable hemodynamic function. Estimated freedom from the composite clinical outcome was 99% at 1 year and 96% at 2 years. Freedom from TPVR-related endocarditis was 98% at 1 year. Five patients died from COVID-19 (n = 1), unknown causes (n = 2), and bloodstream infection (n = 2). CONCLUSIONS: In this large multicenter real-world experience, short-term clinical and hemodynamic outcomes of self-expanding TPVR therapy were excellent. Ongoing follow-up of this cohort will provide important insights into long-term outcomes.
Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar , Valva Pulmonar , Humanos , Adulto , Valva Pulmonar/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Cateterismo Cardíaco/efeitos adversos , Resultado do Tratamento , Insuficiência da Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/etiologia , Sistema de Registros , Desenho de Prótese , Estudos RetrospectivosRESUMO
BACKGROUND: Transcatheter pulmonary valve replacement (TPVR) has expanded and evolved since its initial commercial approval in the United States in 2010. OBJECTIVES: This study sought to characterize real-world practice, including patient selection, procedural outcomes, complications, and off-label usage. METHODS: Characteristics and outcomes for patients undergoing balloon-expandable TPVR were collected from the American College of Cardiology National Cardiovascular Data Registry IMPACT (Improving Pediatric and Adult Congenital Treatment) Registry. RESULTS: Between April 2016 and March 2021, 4,513 TPVR procedures were performed in patients with a median age of 19 years, 57% with a Melody (Medtronic Inc) and 43% with a SAPIEN (Edwards Lifesciences) valve. Most implanting centers performed <10 cases annually. One-third of transcatheter pulmonary valve implants were into homograft conduits, one-third were into bioprosthetic valves (BPVs), 25% were in native or patched right ventricular outflow tracts (RVOTs), and 6% were into Contegra (Medtronic Inc) conduits. Over the course of the study period, SAPIEN valve use grew from â¼25% to 60%, in large part because of implants in patients with a native/patched RVOT. Acute success was achieved in 95% of patients (95.7% in homografts, 96.2% in BPVs, 94.2% in native RVOTs, and 95.4% in Contegra conduits). Major adverse events occurred in 2.4% of procedures, more commonly in patients with a homograft (2.9%) or native RVOT (3.4%) than a prior BPV (1.4%; P = 0.004). CONCLUSIONS: This study describes novel population data on the use and procedural outcomes of TPVR with balloon-expandable valves. Over time, there has been increasing use of TPVR to treat regurgitant native RVOT anatomy, with the SAPIEN valve more commonly used for this application.
Assuntos
Próteses Valvulares Cardíacas , Valva Pulmonar , Substituição da Valva Aórtica Transcateter , Adulto , Humanos , Criança , Adulto Jovem , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Resultado do Tratamento , Sistema de RegistrosRESUMO
The removal of balloon fragments from the pulmonary artery without damaging the pulmonary and tricuspid valves can be difficult. Four cases during transcatheter pulmonary valve replacement are described in which a novel retrieval system was used to facilitate safe removal. (Level of Difficulty: Advanced.).
RESUMO
Patients with repaired tetralogy of Fallot are at elevated risk for ventricular arrhythmia and sudden cardiac death. Over the past decade, the pathogenesis and natural history of ventricular tachycardia has become increasingly understood, and catheter ablation has emerged as an effective treatment modality. Concurrently, there has been great progress in the development of a versatile array of transcatheter valves that can be placed in the native right ventricular outflow tract for the treatment of long-standing pulmonary regurgitation. Although such valve platforms may eliminate the need for repeat cardiac operations, they may also impede catheter access to the myocardial substrates responsible for sustained macro-reentrant ventricular tachycardia. This manuscript provides the rationale and design of a recently devised multicenter study that will examine the clinical outcomes of a uniform, preemptive strategy to eliminate ventricular tachycardia substrates before transcatheter pulmonary valve implantation in patients with tetralogy of Fallot.
Assuntos
Ablação por Cateter , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Pulmonar , Valva Pulmonar , Taquicardia Ventricular , Tetralogia de Fallot , Humanos , Tetralogia de Fallot/complicações , Tetralogia de Fallot/cirurgia , Valva Pulmonar/cirurgia , Arritmias Cardíacas , Insuficiência da Valva Pulmonar/cirurgia , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversosRESUMO
INTRODUCTION: Fontan patients have variable exercise capacity. Contemporary understanding as to which factors predict high tolerance is limited. METHODS: Records from the Ahmanson/University of California, Los Angeles Adult Congenital Heart Disease Center were reviewed for adult Fontan patients who underwent CPET. Patients were considered "high performers" if their maximum oxygen uptake (VO2 max/kg)-predicted was greater than 80%. Cross-sectional clinical, hemodynamic, and liver biopsy data was gathered. High-performers were compared to control patients across these parameters via associations and regression. RESULTS: A total of 195 adult patients were included; 27 patients were considered "high performers". They had lower body mass indices (BMI, p < 0.001), mean Fontan pressures (p = 0.026), and cardiac outputs (p = 0.013). High performers also had higher activity levels (p < 0.001), serum albumin levels (p = 0.003), non-invasive and invasive systemic arterial oxygen saturations (p < 0.001 and p = 0.004), lower New York Heart Association (NYHA) heart failure class (p = 0.002), and were younger at Fontan completion (p = 0.011). High performers had less severe liver fibrosis (p = 0.015). Simple regression found Fontan pressure, non-invasive O2 saturation, albumin level, activity level, age at Fontan surgery, NYHA class, and BMI to predict significant changes in VO2 max/kg %-predicted. These associations persisted in multiple regression for non-invasive O2 saturation, NYHA class II, activity level, and BMI. CONCLUSIONS: Thin Fontan patients who exercise more had better exercise capacity, Fontan hemodynamic profiles, and less liver fibrosis.
Assuntos
Técnica de Fontan , Cardiopatias Congênitas , Humanos , Adulto , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/cirurgia , Consumo de Oxigênio , Tolerância ao Exercício , Estudos Transversais , Oxigênio , Cirrose Hepática , Teste de EsforçoRESUMO
BACKGROUND: The Harmony transcatheter pulmonary valve (TPV) is the first U.S. Food and Drug Administration-approved device for severe pulmonary regurgitation (PR) in the native or surgically repaired right ventricular outflow tract (RVOT). OBJECTIVES: One-year safety and effectiveness of the Harmony TPV were evaluated in patients from the Harmony Native Outflow Tract Early Feasibility Study, Harmony TPV Pivotal Study, and Continued Access Study, representing the largest cohort to date of Harmony TPV recipients. METHODS: Eligible patients had severe PR by echocardiography or PR fraction ≥ 30% by cardiac magnetic resonance imaging and clinical indications for pulmonary valve replacement. The primary analysis included 87 patients who received a commercially available TPV22 (n = 42) or TPV25 (n = 45) device; 19 patients who received an early device iteration prior to its discontinuation were evaluated separately. RESULTS: In the primary analysis, median patient age at treatment was 26 years (IQR: 18-37 years) in the TPV22 group and 29 years (IQR: 19-42 years) in the TPV25 group. At 1 year, there were no deaths; 98% of TPV22 and 91% of TPV25 patients were free from the composite of PR, stenosis, and reintervention (moderate or worse PR, mean RVOT gradient >40 mmHg, device-related RVOT reoperation, and catheter reintervention). Nonsustained ventricular tachycardia occurred in 16% of patients. Most patients had none/trace or mild PR (98% of TPV22 patients, 97% of TPV25 patients). Outcomes with the discontinued device are reported separately. CONCLUSIONS: The Harmony TPV device demonstrated favorable clinical and hemodynamic outcomes across studies and valve types through 1 year. Further follow-up will continue to assess long-term valve performance and durability.
Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar , Valva Pulmonar , Obstrução do Fluxo Ventricular Externo , Humanos , Cateterismo Cardíaco , Estudos Prospectivos , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/cirurgia , Resultado do Tratamento , Obstrução do Fluxo Ventricular Externo/etiologiaRESUMO
BACKGROUND: Recurrent laryngeal nerve injury leading to vocal cord paralysis is a known complication of cardiothoracic surgery. Its occurrence during interventional catheterisation procedures has been documented in case reports, but there have been no studies to determine an incidence. OBJECTIVE: To establish the incidence of left recurrent laryngeal nerve injury leading to vocal cord paralysis after left pulmonary artery stenting, patent ductus arteriosus device closure and the combination of the procedures either consecutively or simultaneously. METHODS: Members of the Congenital Cardiovascular Interventional Study Consortium were asked to perform a retrospective analysis to identify cases of recurrent laryngeal nerve injury after the aforementioned procedures. Twelve institutions participated in the analysis. They also contributed the total number of each procedure performed at their respective institutions for statistical purposes. RESULTS: Of the 1337 patients who underwent left pulmonary artery stent placement, six patients (0.45%) had confirmed vocal cord paralysis. 4001 patients underwent patent ductus arteriosus device closure, and two patients (0.05%) developed left vocal cord paralysis. Patients who underwent both left pulmonary artery stent placement and patent ductus arteriosus device closure had the highest incidence of vocal cord paralysis which occurred in 4 of the 26 patients (15.4%). Overall, 92% of affected patients in our study population had resolution of symptoms. CONCLUSION: Recurrent laryngeal nerve injury is a rare complication of left pulmonary artery stent placement or patent ductus arteriosus device closure. However, the incidence is highest in patients undergoing both procedures either consecutively or simultaneously. Additional research is necessary to determine contributing factors that might reduce the risk of recurrent laryngeal nerve injury.
Assuntos
Permeabilidade do Canal Arterial , Traumatismos do Nervo Laríngeo Recorrente , Paralisia das Pregas Vocais , Humanos , Traumatismos do Nervo Laríngeo Recorrente/etiologia , Traumatismos do Nervo Laríngeo Recorrente/complicações , Paralisia das Pregas Vocais/epidemiologia , Paralisia das Pregas Vocais/etiologia , Permeabilidade do Canal Arterial/epidemiologia , Permeabilidade do Canal Arterial/cirurgia , Permeabilidade do Canal Arterial/complicações , Incidência , Estudos Retrospectivos , Cateterismo/efeitos adversosRESUMO
BACKGROUND: Transcatheter pulmonary valve (TPV) replacement (TPVR) has become the standard therapy for postoperative pulmonary outflow tract dysfunction in patients with a prosthetic conduit/valve, but there is limited information about risk factors for death or reintervention after this procedure. OBJECTIVES: This study sought to evaluate mid- and long-term outcomes after TPVR in a large multicenter cohort. METHODS: International registry focused on time-related outcomes after TPVR. RESULTS: Investigators submitted data for 2,476 patients who underwent TPVR and were followed up for 8,475 patient-years. A total of 95 patients died after TPVR, most commonly from heart failure (n = 24). The cumulative incidence of death was 8.9% (95% CI: 6.9%-11.5%) 8 years after TPVR. On multivariable analysis, age at TPVR (HR: 1.04 per year; 95% CI: 1.03-1.06 per year; P < 0.001), a prosthetic valve in other positions (HR: 2.1; 95% CI: 1.2-3.7; P = 0.014), and an existing transvenous pacemaker/implantable cardioverter-defibrillator (HR: 2.1; 95% CI: 1.3-3.4; P = 0.004) were associated with death. A total of 258 patients underwent TPV reintervention. At 8 years, the cumulative incidence of any TPV reintervention was 25.1% (95% CI: 21.8%-28.5%) and of surgical TPV reintervention was 14.4% (95% CI: 11.9%-17.2%). Risk factors for surgical reintervention included age (0.95 per year [95% CI: 0.93-0.97 per year]; P < 0.001), prior endocarditis (2.5 [95% CI: 1.4-4.3]; P = 0.001), TPVR into a stented bioprosthetic valve (1.7 [95% CI: 1.2-2.5]; P = 0.007), and postimplant gradient (1.4 per 10 mm Hg [95% CI: 1.2-1.7 per 10 mm Hg]: P < 0.001). CONCLUSIONS: These findings support the conclusion that survival and freedom from reintervention or surgery after TPVR are generally comparable to outcomes of surgical conduit/valve replacement across a wide age range.
Assuntos
Implante de Prótese de Valva Cardíaca , Valva Pulmonar/cirurgia , Reoperação/estatística & dados numéricos , Adolescente , Adulto , Fatores Etários , Criança , Pré-Escolar , Desfibriladores Implantáveis , Endocardite/epidemiologia , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Lactente , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial , Sistema de Registros , Adulto JovemRESUMO
Zinc (Zn) and Zn alloys have been studied as potential materials for bioresorbable stents (BRSs) in the last decade due to their favorable biodegradability and biocompatibility. However, most Zn alloys lack the necessary combination of strength, ductility, fatigue resistance, corrosion rate (CR), and thermal stability needed for such applications. In this study, nanoparticles made of tungsten carbide (WC) were successfully incorporated into Zn alloyed with 0.5 wt % magnesium (Mg) and evaluated for their suitability for BRS applications. Specifically, the resulting Zn-0.5Mg-WC nanocomposite's microstructure, mechanical properties, in vitro CR, and thermal stability were evaluated. The Zn-0.5Mg-WC nanocomposite had excellent mechanical strength [ultimate tensile strength (UTS) > 250 MPa], elongation to failure (>30%), and a suitable in vitro CR (â¼0.02 mm/y) for this clinical application. Moreover, the Zn-0.5Mg-WC nanocomposite survived 10 million cycles of tensile loading (stress ratio, R = 0.053) when the maximum stress was 80% of the yield stress. Its ductility was also retained during a 90-day thermal stability study, indicating an excellent shelf life. Stent prototypes were fabricated using this composition and were successfully deployed during bench testing without fracture. These results show that the Zn-0.5Mg-WC nanocomposite is a promising material for BRS applications. In vivo studies are underway to validate both biocompatibility, stent function, and degradation.
Assuntos
Magnésio , Nanocompostos , Implantes Absorvíveis , Corrosão , Teste de Materiais , Stents/efeitos adversos , ZincoRESUMO
Transcatheter pulmonary valve replacement was first performed by Dr Philip Bonhoeffer, who implanted a Medtronic Melody valve in a human in 2000. Over the past 2 decades, there have been many advances in transcatheter pulmonary valve technology. This includes the use of the SAPIEN transcatheter heart valve in the pulmonary position, modifications and refinements to valve implantation procedures, and development of self-expanding valves and prestents to treat large diameter native or patched right ventricular outflow tracts. This article reviews the current transcatheter pulmonary valve technologies with a focus on valve design, screening process, implant procedure, and clinical outcomes.
Assuntos
Cateterismo Cardíaco/métodos , Seio Coronário/cirurgia , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Comunicação Interatrial/cirurgia , Impressão Tridimensional , Dispositivo para Oclusão Septal , Seio Coronário/diagnóstico por imagem , Comunicação Interatrial/diagnóstico , Humanos , Masculino , Pessoa de Meia-IdadeRESUMO
BACKGROUND: Endocarditis has emerged as one of the most impactful adverse events after transcatheter pulmonary valve replacement (TPVR), but there is limited information about risk factors for and outcomes of this complication. OBJECTIVES: The purpose of this study was to evaluate risk factors for and outcomes of endocarditis in a large multicenter cohort. METHODS: The authors established an international registry focused on characterizing endocarditis after TPVR, including the incidence, risk factors, characteristics, and outcomes. RESULTS: Investigators submitted data for 2,476 patients who underwent TPVR between July 2005 and March 2020 and were followed for 8,475 patient-years. In total, 182 patients were diagnosed with endocarditis a median of 2.7 years after TPVR, for a cumulative incidence of 9.5% (95% CI: 7.9%-11.1%) at 5 years and 16.9% (95% CI: 14.2%-19.8%) at 8 years (accounting for competing risks: death, heart transplant, and explant) and an annualized incidence of 2.2 per 100 patient-years. Staphylococcus aureus and Viridans group Streptococcus species together accounted for 56% of cases. Multivariable analysis confirmed that younger age, a previous history of endocarditis, and a higher residual gradient were risk factors for endocarditis, but transcatheter pulmonary valve type was not. Overall, right ventricular outflow tract (RVOT) reintervention was less often to treat endocarditis than for other reasons, but valve explant was more often caused by endocarditis. Endocarditis was severe in 44% of patients, and 12 patients (6.6%) died, nearly all of whom were infected with Staphylococcus aureus. CONCLUSIONS: The incidence of endocarditis in this multicenter registry was constant over time and consistent with prior smaller studies. The findings of this study, along with ongoing efforts to understand and mitigate risk, will be critical to improve the lifetime management of patients with heart disease involving the RVOT. Although endocarditis can be a serious adverse outcome, TPVR remains an important tool in the management of RVOT dysfunction.
Assuntos
Endocardite , Implante de Prótese de Valva Cardíaca , Valva Pulmonar/cirurgia , Reoperação , Adulto , Cateterismo Cardíaco/métodos , Endocardite/etiologia , Endocardite/microbiologia , Endocardite/mortalidade , Endocardite/cirurgia , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/estatística & dados numéricos , Humanos , Incidência , Cooperação Internacional , Masculino , Sistema de Registros/estatística & dados numéricos , Reoperação/métodos , Reoperação/estatística & dados numéricos , Staphylococcus aureus/isolamento & purificação , Obstrução do Fluxo Ventricular Externo/etiologia , Obstrução do Fluxo Ventricular Externo/cirurgia , Estreptococos Viridans/isolamento & purificaçãoRESUMO
Cor triatriatum sinister (CTS) is a rare congenital cardiac anomaly representing <0.1% of all congenital cardiac malformations. It is characterized by the presence of a left atrial (LA) membrane that leads to left ventricular inflow obstruction. Uncorrected, obstructed CTS may have significant sequelae such as pulmonary hypertension or arrhythmias. Transcatheter balloon decompression has been described as a successful alternative to surgical resection of the obstructing membrane. Our review of the literature revealed no reported cases utilizing radiofrequency (RF) energy to perforate the CTS membrane prior to balloon decompression. This manuscript describes two patients with CTS who were treated successfully with a transcatheter technique using RF energy to perforate the obstructing membrane prior to balloon angioplasty and decompression of the LA.
Assuntos
Coração Triatriado , Cardiopatias Congênitas , Coração Triatriado/complicações , Coração Triatriado/diagnóstico por imagem , Coração Triatriado/cirurgia , Descompressão , Ventrículos do Coração , Humanos , Resultado do TratamentoRESUMO
OBJECTIVES: A large-diameter, intravascular, self-expanding stent system capable of continued expansion during somatic and vascular growth was modeled with finite element analysis (FEA), manufactured and tested in an animal model. BACKGROUND: Children can quickly outgrow intravascular stents. If a stent could expand after implantation in arteries this would be ideal for use in pediatric patients. METHODS: Computer-aided design and FEA were used to design and manufacture large-diameter, self-expanding nitinol stents with both high and low chronic outward force (COF). Four distinct stents with similar designs but with variable lengths and strut thicknesses were manufactured. Fourteen of these stents were implanted in the abdominal aortas or iliac arteries of four juvenile swine. RESULTS: All animals survived without complication to their designated time points of harvest (90 or 180-days), and all stents expanded to greater diameters than the adjacent non-stented artery. Luminal diameter growth was 34-49% and 20-23% for stented and non-stented segments, respectively. Histologic examination revealed variable degrees of the internal elastic lamina and/or medial disruption with a mean injury score ranging from 0.70 ± 0.56 to 1.23 ± 0.21 and low COF stents implanted in smaller arteries having a larger injury score. Inflammatory responses and stenosis formation were minimal and ranged from 0.50 ± 0.71 to 3.00 ± 0.00 and 5.52 ± 1.05% to 14.68 ± 9.12%, respectively. The stent's COF did not correlate with vessel expansion or vascular injury. CONCLUSIONS: Self-expanding stents can mirror and even exceed somatic growth. Although longer-term testing is needed, it may be possible to custom tailor self-expanding stents to expand after arterial implantation in pediatric patients.
Assuntos
Ligas , Stents , Animais , Biologia , Criança , Constrição Patológica , Humanos , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/cirurgia , Suínos , Resultado do TratamentoRESUMO
Single ventricle hearts palliated with the Fontan operation present complications later in life as a result of increased venous pressures and abnormal ventricle function. Wave intensity analysis uses measurements of blood velocity and pressure to represent arterial hemodynamics as summations of energy waves. This methodology could potentially be a useful tool in assessment of Fontan patients. The clinical value of wave intensity parameters was utilized to evaluate the functional performance of the single ventricle in Fontan patients. A retrospective analysis of invasive hemodynamic data was retrospectively obtained from routine cardiac catheterization of patients with Fontan circulation (n = 20) and comparison to those with biventricular circulation (n = 10) who presented to the catheterization laboratory for closure of small patent ductus arteriosus (PDAs). Wave intensity analysis and wave energy flux was calculated using aortic pressure waveforms and echocardiography aortic Doppler measurements as previously described. Significant differences were seen in the peak forward compression wave (p = 0.013), early systolic energy flux (p = 0.005) and the systolic and diastolic ratio (p = 0.006) in Fontan patients versus controls. Within the Fontan group, there was a positive correlation (0.54, p = 0.02) between the wave speed and pulmonary vascular resistance. Early systolic energy flux was a potential individual indicator of a Fontan patients heart failure classification (AUC = 0.71). Wave intensity analysis could be a useful tool in screening Fontan patients and predicting clinical outcomes and Fontan failure. Future prospective analyses of Fontan hemodynamics and WIA are needed.
Assuntos
Pressão Arterial , Ecocardiografia Doppler/métodos , Técnica de Fontan/efeitos adversos , Coração Univentricular/cirurgia , Função Ventricular , Adolescente , Cateterismo Cardíaco/métodos , Criança , Pré-Escolar , Diástole , Permeabilidade do Canal Arterial/terapia , Feminino , Técnica de Fontan/métodos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/etiologia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Hemodinâmica , Humanos , Lactente , Masculino , Análise de Onda de Pulso/métodos , Estudos Retrospectivos , Coração Univentricular/diagnóstico por imagem , Coração Univentricular/fisiopatologia , Adulto JovemRESUMO
OBJECTIVES: To determine over-dilation potential of commercially available covered stents. BACKGROUND: Covered stents including the Atrium iCast, Gore VBX, and Lifestream stents (LS) can treat ruptures, dissections, and aneurysms in small vessels. Especially in growing patients, stents often require serial dilations beyond their implant or nominal diameters. Tolerance of serial dilations is clinically important information for interventionalists. METHODS: Serial dilations of 5-12 mm iCast, VBX, and LS covered stents were performed in 1-2 mm increments (up to 20 mm). With each dilation, foreshortening and recoil were measured, and stent strut and covering integrity were assessed. High-pressure balloons were used to expand the stents until they fractured or could not be further expanded. RESULTS: The 5-8 mm LS tolerated dilation to 14.5-16 mm. The 10-12 mm LS stents tolerated dilation to 18 mm and fractured on the 20 mm balloon. LS stents foreshortened 35%-45% on average after 8 mm of over-dilation and had 5%-10% recoil on <6 mm over-dilation. All iCast stents tolerated dilation to 12-13 mm and required fracture for dilation to >14 mm. ICast stents foreshortened 19%-29% at maximum dilation, with 3-6% recoil on <2 mm over-dilation, and < 3% thereafter. VBX stents over-dilated to 2.9-4.7 mm above nominal, foreshortening 40%-50% after 4-6 mm of over-dilation before collapsing into a ring. VBX stent recoil was <2.5% on all dilations. CONCLUSIONS: LS stents had the greatest over-dilation potential. VBX stents had the least recoil but tended to foreshorten significantly 3-4 mm above nominal. Regardless of nominal size, all iCast stents (including the 5 mm) tolerated dilation to a maximum of 12-13 mm.
Assuntos
Stents , Dilatação , Humanos , Desenho de Prótese , Resultado do TratamentoRESUMO
Transcatheter closure of large apical muscular ventricular septal defects (VSDs) can be performed via transfemoral or hybrid approach. A very large apical muscular VSD was closed via a hybrid approach. A strategy for deployment of a right ventricular stay suture was utilized to minimize the risk of device embolization without the use of bypass and without externalization of a portion of the device.
Assuntos
Comunicação Interventricular , Cateterismo Cardíaco/efeitos adversos , Comunicação Interventricular/diagnóstico por imagem , Comunicação Interventricular/cirurgia , Ventrículos do Coração , Humanos , Suturas , Resultado do TratamentoRESUMO
BACKGROUND: There are limited published data focused on outcomes of transcatheter pulmonary valve replacement (TPVR) with either a Sapien XT or Sapien 3 (S3) valve. OBJECTIVES: This study sought to report short-term outcomes in a large cohort of patients who underwent TPVR with either a Sapien XT or S3 valve. METHODS: Data were entered retrospectively into a multicenter registry for patients who underwent attempted TPVR with a Sapien XT or S3 valve. Patient-related, procedural, and short-term outcomes data were characterized overall and according to type of right ventricular outflow tract (RVOT) anatomy. RESULTS: Twenty-three centers enrolled a total of 774 patients: 397 (51%) with a native/patched RVOT; 183 (24%) with a conduit; and 194 (25%) with a bioprosthetic valve. The S3 was used in 78% of patients, and the XT was used in 22%, with most patients receiving a 29-mm (39%) or 26-mm (34%) valve. The implant was technically successful in 754 (97.4%) patients. Serious adverse events were reported in 67 patients (10%), with no difference between RVOT anatomy groups. Fourteen patients underwent urgent surgery. Nine patients had a second valve implanted. Among patients with available data, tricuspid valve injury was documented in 11 (1.7%), and 9 others (1.3%) had new moderate or severe regurgitation 2 grades higher than pre-implantation, for 20 (3.0%) total patients with tricuspid valve complications. Valve function at discharge was excellent in most patients, but 58 (8.5%) had moderate or greater pulmonary regurgitation or maximum Doppler gradients >40 mm Hg. During limited follow-up (n = 349; median: 12 months), 9 patients were diagnosed with endocarditis, and 17 additional patients underwent surgical valve replacement or valve-in-valve TPVR. CONCLUSIONS: Acute outcomes after TPVR with balloon-expandable valves were generally excellent in all types of RVOT. Additional data and longer follow-up will be necessary to gain insight into these issues.