Resultados 1 - 15 de 15
Filtrar
2.
Infect Control Hosp Epidemiol ; 43(6): 764-769, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-33966671

RESUMO

OBJECTIVE: To assess the potential for contamination of personnel, patients, and the environment during use of contaminated N95 respirators and to compare the effectiveness of interventions to reduce contamination. DESIGN: Simulation study of patient care interactions using N95 respirators contaminated with a higher and lower inocula of the benign virus bacteriophage MS2. METHODS: In total, 12 healthcare personnel performed 3 standardized examinations of mannequins including (1) control with suboptimal respirator handling technique, (2) improved technique with glove change after each N95 contact, and (3) control with 1-minute ultraviolet-C light (UV-C) treatment prior to donning. The order of the examinations was randomized within each subject. The frequencies of contamination were compared among groups. Observations and simulations with fluorescent lotion were used to assess routes of transfer leading to contamination. RESULTS: With suboptimal respirator handling technique, bacteriophage MS2 was frequently transferred to the participants, mannequin, and environmental surfaces and fomites. Improved technique resulted in significantly reduced transfer of MS2 in the higher inoculum simulations (P < .01), whereas UV-C treatment reduced transfer in both the higher- and lower-inoculum simulations (P < .01). Observations and simulations with fluorescent lotion demonstrated multiple potential routes of transfer to participants, mannequin, and surfaces, including both direct contact with the contaminated respirator and indirect contact via contaminated gloves. CONCLUSION: Reuse of contaminated N95 respirators can result in contamination of personnel and the environment even when correct technique is used. Decontamination technologies, such as UV-C, could reduce the risk for transmission.


Assuntos
COVID-19 , Respiradores N95 , Descontaminação/métodos , Reutilização de Equipamento , Fômites , Humanos , Levivirus , SARS-CoV-2
4.
Pathog Immun ; 6(1): 104-115, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34136729

RESUMO

BACKGROUND: Ultraviolet-C (UV-C) light devices are effective in reducing contamination on N95 filtering facepiece respirators. However, limited information is available on whether UV-C devices meet the Food and Drug Administration's (FDA) microbiological requirements for Emergency Use Authorization (EUA) for respirator bioburden reduction. METHODS: We tested the ability of 2 UV-C light boxes to achieve the 3-log10 microorganism reductions required for EUA for reuse by single users. Whole 3M 1860 or Moldex 1513 respirators were inoculated on the exterior facepiece, interior facepiece, and internal fibers with bacteriophage MS2 and/or 4 strains of bacteria and treated with UV-C cycles of 1 or 20 minutes. Colorimetric indicators were used to assess penetration of UV-C through the respirators. RESULTS: For 1 UV-C box, a 20-minute treatment achieved the required bioburden reduction for Moldex 1513 but not 3M 1860 respirators. For the second UV-C box, a 1-minute treatment achieved the required bioburden reduction in 4 bacterial strains for the Moldex 1513 respirator. Colorimetric indicators demonstrated penetration of UV-C through all layers of the Moldex 1513 respirator but not the 3M 1860 respirator. CONCLUSIONS: Our findings demonstrate that UV-C box technologies can achieve bioburden reductions required by the FDA for EUA for single users but highlight the potential for variable efficacy for different types of respirators.

6.
Infect Control Hosp Epidemiol ; 42(2): 215-217, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32782056

RESUMO

On coronavirus disease 2019 (COVID-19) wards, severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) nucleic acid was frequently detected on high-touch surfaces, floors, and socks inside patient rooms. Contamination of floors and shoes was common outside patient rooms on the COVID-19 wards but decreased after improvements in floor cleaning and disinfection were implemented.


Assuntos
COVID-19/transmissão , Poluição Ambiental/análise , Unidades de Terapia Intensiva , Quartos de Pacientes , SARS-CoV-2/isolamento & purificação , COVID-19/virologia , Vestuário , Desinfecção/métodos , Contaminação de Equipamentos , Hospitais de Veteranos , Humanos , Ohio , Reação em Cadeia da Polimerase em Tempo Real
7.
Infect Control Hosp Epidemiol ; 42(4): 425-430, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33040741

RESUMO

BACKGROUND: There is controversy regarding whether the addition of cover gowns offers a substantial benefit over gloves alone in reducing personnel contamination and preventing pathogen transmission. DESIGN: Simulated patient care interactions. OBJECTIVE: To evaluate the efficacy of different types of barrier precautions and to identify routes of transmission. METHODS: In randomly ordered sequence, 30 personnel each performed 3 standardized examinations of mannequins contaminated with pathogen surrogate markers (cauliflower mosaic virus DNA, bacteriophage MS2, nontoxigenic Clostridioides difficile spores, and fluorescent tracer) while wearing no barriers, gloves, or gloves plus gowns followed by examination of a noncontaminated mannequin. We compared the frequency and routes of transfer of the surrogate markers to the second mannequin or the environment. RESULTS: For a composite of all surrogate markers, transfer by hands occurred at significantly lower rates in the gloves-alone group (OR, 0.02; P < .001) and the gloves-plus-gown group (OR, 0.06; P = .002). Transfer by stethoscope diaphragms was common in all groups and was reduced by wiping the stethoscope between simulations (OR, 0.06; P < .001). Compared to the no-barriers group, wearing a cover gown and gloves resulted in reduced contamination of clothing (OR, 0.15; P < .001), but wearing gloves alone did not. CONCLUSIONS: Wearing gloves alone or gloves plus gowns reduces hand transfer of pathogens but may not address transfer by devices such as stethoscopes. Cover gowns reduce the risk of contaminating the clothing of personnel.


Assuntos
Infecção Hospitalar , Estetoscópios , Infecção Hospitalar/prevenção & controle , Atenção à Saúde , Luvas Protetoras , Humanos , Transferência de Pacientes , Roupa de Proteção
8.
Infect Control Hosp Epidemiol ; 42(6): 678-687, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33040749

RESUMO

BACKGROUND: Critical shortages of personal protective equipment, especially N95 respirators, during the coronavirus disease 2019 (COVID-19) pandemic continues to be a source of concern. Novel methods of N95 filtering face-piece respirator decontamination that can be scaled-up for in-hospital use can help address this concern and keep healthcare workers (HCWs) safe. METHODS: A multidisciplinary pragmatic study was conducted to evaluate the use of an ultrasonic room high-level disinfection system (HLDS) that generates aerosolized peracetic acid (PAA) and hydrogen peroxide for decontamination of large numbers of N95 respirators. A cycle duration that consistently achieved disinfection of N95 respirators (defined as ≥6 log10 reductions in bacteriophage MS2 and Geobacillus stearothermophilus spores inoculated onto respirators) was identified. The treated masks were assessed for changes to their hydrophobicity, material structure, strap elasticity, and filtration efficiency. PAA and hydrogen peroxide off-gassing from treated masks were also assessed. RESULTS: The PAA room HLDS was effective for disinfection of bacteriophage MS2 and G. stearothermophilus spores on respirators in a 2,447 cubic-foot (69.6 cubic-meter) room with an aerosol deployment time of 16 minutes and a dwell time of 32 minutes. The total cycle time was 1 hour and 16 minutes. After 5 treatment cycles, no adverse effects were detected on filtration efficiency, structural integrity, or strap elasticity. There was no detectable off-gassing of PAA and hydrogen peroxide from the treated masks at 20 and 60 minutes after the disinfection cycle, respectively. CONCLUSION: The PAA room disinfection system provides a rapidly scalable solution for in-hospital decontamination of large numbers of N95 respirators during the COVID-19 pandemic.


Assuntos
COVID-19/prevenção & controle , Descontaminação/métodos , Desinfetantes/uso terapêutico , Contaminação de Equipamentos/prevenção & controle , Respiradores N95/virologia , Ácido Peracético/uso terapêutico , SARS-CoV-2 , Aerossóis , Infecção Hospitalar/prevenção & controle , Infecção Hospitalar/virologia , Desinfetantes/administração & dosagem , Geobacillus stearothermophilus , Humanos , Peróxido de Hidrogênio/administração & dosagem , Peróxido de Hidrogênio/uso terapêutico , Levivirus , Respiradores N95/efeitos adversos , Respiradores N95/microbiologia , Ácido Peracético/administração & dosagem
9.
Am J Infect Control ; 49(4): 424-429, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33186675

RESUMO

BACKGROUND: Filtering facepiece respirators (FFR) are critical for protecting essential personnel and limiting the spread of disease. Due to the current COVID-19 pandemic, FFR supplies are dwindling in many health systems, necessitating re-use of potentially contaminated FFR. Multiple decontamination solutions have been developed to meet this pressing need, including systems designed for bulk decontamination of FFR using vaporous hydrogen peroxide or ultraviolet-C (UV-C) radiation. However, the large scale on which these devices operate may not be logistically practical for small or rural health care settings or for ad hoc use at points-of-care. METHODS: Here, we present the Synchronous UV Decontamination System, a novel device for rapidly deployable, point-of-care decontamination using UV-C germicidal irradiation. We designed a compact, easy-to-use device capable of delivering over 2 J cm2 of UV-C radiation in one minute. RESULTS: We experimentally tested Synchronous UV Decontamination System' microbicidal capacity and found that it eliminates near all virus from the surface of tested FFRs, with less efficacy against pathogens embedded in the inner layers of the masks. CONCLUSIONS: This short decontamination time should enable care-providers to incorporate decontamination of FFR into a normal donning and doffing routine following patient encounters.


Assuntos
COVID-19/prevenção & controle , Descontaminação/instrumentação , Sistemas Automatizados de Assistência Junto ao Leito , Dispositivos de Proteção Respiratória/virologia , SARS-CoV-2 , Raios Ultravioleta , COVID-19/virologia , Descontaminação/métodos , Reutilização de Equipamento , Humanos
10.
Am J Infect Control ; 48(8): 951-954, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32522608

RESUMO

In the setting of the coronavirus disease 2019 pandemic, efficient methods are needed to decontaminate shared portable devices and large open areas such as waiting rooms. We found that wheelchairs, portable equipment, and waiting room chairs were frequently contaminated with potential pathogens. After minimal manual precleaning of areas with visible soiling, application of a dilute sodium hypochlorite disinfectant using an electrostatic sprayer provided rapid and effective decontamination and eliminated the benign virus bacteriophage MS2 from inoculated surfaces.


Assuntos
Infecções por Coronavirus/prevenção & controle , Infecção Hospitalar/prevenção & controle , Descontaminação/métodos , Desinfecção/métodos , Contaminação de Equipamentos/prevenção & controle , Pandemias/prevenção & controle , Pneumonia Viral/prevenção & controle , Betacoronavirus/patogenicidade , COVID-19 , Infecção Hospitalar/virologia , Desinfetantes/administração & dosagem , Humanos , SARS-CoV-2
11.
Pathog Immun ; 5(1): 133-142, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32582873

RESUMO

BACKGROUND: Contaminated surfaces are a potential source for spread of respiratory viruses including SARS-CoV-2. Ultraviolet-C (UV-C) light is effective against RNA and DNA viruses and could be useful for decontamination of high-touch fomites that are shared by multiple users. METHODS: A modification of the American Society for Testing and Materials standard quantitative carrier disk test method (ASTM E-2197-11) was used to examine the effectiveness of UV-C light for rapid decontamination of plastic airport security bins inoculated at 3 sites with methicillin-resistant Staphylococcus aureus (MRSA) and bacteriophages MS2, PhiX174, and Phi6, an enveloped RNA virus used as a surrogate for coronaviruses. Reductions of 3 log10 on inoculated plastic bins were considered effective for decontamination. RESULTS: UV-C light administered as 10-, 20-, or 30-second cycles in proximity to a plastic bin reduced contamination on each of the test sites, including vertical and horizontal surfaces. The 30-second cycle met criteria for decontamination of all 3 test sites for all the test organisms except bacteriophage MS2 which was reduced by greater than 2 log10 PFU at each site. CONCLUSIONS: UV-C light is an attractive technology for rapid decontamination of airport security bins. Further work is needed to evaluate the utility of UV-C light in real-world settings and to develop methods to provide automated movement of bins through a UV-C decontamination process.

12.
Pathog Immun ; 5(1): 52-67, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32363254

RESUMO

BACKGROUND: Shortages of personal protective equipment (PPE) including N95 respirators are an urgent concern in the setting of the global COVID-19 pandemic. Decontamination of PPE could be useful to maintain adequate supplies, but there is uncertainty regarding the efficacy of decontamination technologies. METHODS: A modification of the American Society for Testing and Materials standard quantitative carrier disk test method (ASTM E-2197-11) was used to examine the effectiveness of 3 methods, including ultraviolet-C (UV-C) light, a high-level disinfection cabinet that generates aerosolized peracetic acid and hydrogen peroxide, and dry heat at 70°C for 30 minutes. We assessed the decontamination of 3 commercial N95 respirators inoculated with methicillin-resistant Staphylococcus aureus (MRSA) and bacteriophages MS2 and Phi6; the latter is an enveloped RNA virus used as a surrogate for coronaviruses. Three and 6 log10 reductions on respirators were considered effective for decontamination and disinfection, respectively. RESULTS: UV-C administered as a 1-minute cycle in a UV-C box or a 30-minute cycle by a room decontamination device reduced contamination but did not meet criteria for decontamination of the viruses from all sites on the N95s. The high-level disinfection cabinet was effective for decontamination of the N95s and achieved disinfection with an extended 31-minute cycle. Dry heat at 70°C for 30 minutes was not effective for decontamination of the bacteriophages. CONCLUSIONS: UV-C could be useful to reduce contamination on N95 respirators. However, the UV-C technologies studied did not meet pre-established criteria for decontamination under the test conditions used. The high-level disinfection cabinet was more effective and met criteria for disinfection with an extended cycle.

14.
Infect Control Hosp Epidemiol ; 41(8): 962-964, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32456719

RESUMO

For patients with methicillin-resistant Staphylococcus aureus (MRSA) colonization, a traditional fist-bump greeting did not significantly reduce MRSA transfer in comparison to a handshake. However, transfer was reduced with a modified fist bump that minimized the surface area of contact and when hand hygiene was performed before the handshake.


Assuntos
Higiene das Mãos , Staphylococcus aureus Resistente à Meticilina , Infecções Estafilocócicas , Humanos , Infecções Estafilocócicas/prevenção & controle
SELEÇÃO DE REFERÊNCIAS