1.
J Chromatogr A ; 1628: 461449, 2020 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-32822988

RESUMO

This paper reported a new method for the determination of the water distribution in sludge. It was based on a multiple headspace extraction (MHE) procedure to step-wise remove the water vapor from a closed vial containing a sludge sample, followed by a gas chromatographic measurement (GC). By plotting the GC signal of water vapor vs. the headspace extraction number, three different trend lines from the profile can be observed. From which two transition points can be determined and thus the stages for the free water, capillary water, and adsorption water release can be divided. Based on the sum of GC peak areas ate each stage, the content of these water types in the sludge can be calculated through a method calibration. The results showed that the MHE-GC method has a better measurement repeatability (RSD < 18.6%) and sensitivity (limit of quantitation = 0.028%) than the thermal drying method (used as a reference method). There was also a good agreement between the MHE-GC and the reference method on the free water and capillary water analysis. Moreover, the results on the adsorption water and bound water testing by the present method is more justifiable than the reference method.


Assuntos
Cromatografia Gasosa/métodos , Esgotos/análise , Água/análise , Calibragem , Dessecação , Pressão , Reprodutibilidade dos Testes , Temperatura , Fatores de Tempo