Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Turk J Chem ; 45(4): 1133-1145, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34707439

RESUMO

A series of Zr(SO4)2/SiO2 solid acid catalysts with different Zr(SO4)2 loadings were prepared by water-soluble-impregnation method at room temperature. Then, the prepared catalysts were characterized by Fourier transform infrared spectroscopy, transmission electron microscopy and energy-dispersive X-ray spectrum, X-ray diffraction, adsorption/desorption of N2, and temperature-programmed desorption of NH3. The results showed that the active component Zr(SO4)2 was successfully adhered to the mesoporous SiO2, and the acid amount of Zr(SO4)2/SiO2 increased with the increasing of the Zr(SO4)2 loadings. Finally, the wheat stalk was used as raw material and depolymerized over Zr(SO4)2/SiO2 to produce ethyl levulinate (EL). The reaction mixture was separated and purified by filtration and vacuum distillation. The kinetic characteristics and the reaction pathway were also studied. A comparative study showed that 20 wt.% Zr(SO4)2/SiO2 exhibited higher catalytic activity. When reaction temperature, time, catalyst dosage and Zr(SO4)2 loadings were 190 °C, 50 min, 20 wt.% and 30 wt.%, the EL yield reached a maximum of 17.14%. The relative content of EL exceeded 90% after three steps of distillation.

2.
J Virol Methods ; 276: 113793, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31794781

RESUMO

Dengue fever is a highly endemic arthropod-borne viral disease in the tropical and sub-tropical countries and is rapidly becoming a global threaten. Diagnosis has been conducted by either traditional serological methods or molecular biological techniques. However, these methods are either labor-intensive, time-consuming or with multiple steps, which are not suitable for high throughput detection of large quantity of samples. In the current study, a novel, rapid, no-wash one-step amplified luminescent proximity homogenous assay-linked immunosorbent assay (AlphaLISA) was developed and optimized for the diagnosis of dengue fever through the detection of dengue virus non-structural protein 1 (NS1). The linear range of the assay was determined to be 60,000 pg/mL to 200 pg/mL, with a lower detection limit of 127.45 pg/mL for NS1 protein. The precision of the assay was 8.24 % and 4.93 % for the high and low concentration. Clinical evaluation indicated that the sensitivity and specificity of the assay was 91.49 % and 81.54 %, respectively. This novel, rapid, no-wash one-step AlphaLISA assay is convenient and sensitive, which could be a good alternative for the screening of dengue fever in a high throughput format.


Assuntos
Vírus da Dengue/química , Dengue/diagnóstico , Imunoensaio/métodos , Proteínas não Estruturais Virais/análise , Humanos , Limite de Detecção , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Space Med Med Eng (Beijing) ; 16 Suppl: 494-9, 2003.
Artigo em Chinês | MEDLINE | ID: mdl-14989304

RESUMO

OBJECTIVE: To examine and evaluate the vestibular function of Chinese astronaut candidates in order to select the astronauts with good vestibular function. METHOD: Fifty-nine male candidates, the fighter plane pilots, participated in the Caloric tests, and 38 pilots among all the candidates experienced the parallel swing and Coriolis acceleration stimuli in tests. The parameters, such as vestibule-autonomic nervous reflex symptoms, electrogastrography (EGG), electronystagmography (ENG), ECG, blood pressure, postural equilibrium ability were employed to evaluate the vestibular function. RESULT: Caloric tests indicated that there were function symmetry on both sides of semicircular canals, as well as normality of visual-vestibular and vestibulo-ocular reflexes in all the candidates. The parallel swing and Coriolis acceleration stimulus demonstrated that there were differences of vestibular functions in 38 pilots. Incidence of I category (stability type) of vestibular function exceeded 52.6%, and II category (relatively stable type) approached 42.1% as well III category (relatively susceptible type) was reported to be 5.3%. CONCLUSION: Vestibular function of astronaut candidates could be evaluated comprehensively and objectively in the present tests. The Chinese astronauts can be chosen from the candidates with stable type or relatively stable type up to standard vestibular function.


Assuntos
Astronautas , Enjoo devido ao Movimento , Seleção de Pessoal , Voo Espacial , Vestíbulo do Labirinto/fisiologia , Pressão Sanguínea/fisiologia , Testes Calóricos , China , Força Coriolis , Eletrofisiologia , Motilidade Gastrointestinal/fisiologia , Humanos , Masculino , Nistagmo Optocinético/fisiologia , Ausência de Peso
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA