Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Neuroeng Rehabil ; 14(1): 122, 2017 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-29183339

RESUMO

BACKGROUND: Hemiplegic shoulder pain is a frequent complication after stroke, leading to limited use of the affected arm. Neuromuscular electrical stimulation (NMES) and transcutaneous electrical nerve stimulation (TENS) are two widely used interventions to reduce pain, but the comparative efficacy of these two modalities remains uncertain. The purpose of this research was to compare the immediate and retained effects of EMG-triggered NMES and TENS, both in combination with bilateral arm training, on hemiplegic shoulder pain and arm function of stroke patients. METHODS: A single-blind, randomized controlled trial was conducted at two medical centers. Thirty-eight patients (25 males and 13 females, 60.75 ± 10.84 years old, post stroke duration 32.68 ± 53.07 months) who had experienced a stroke more than 3 months ago at the time of recruitment and hemiplegic shoulder pain were randomized to EMG-triggered NMES or TENS. Both groups received electrical stimulation followed by bilateral arm training 3 times a week for 4 weeks. The primary outcome measures included a vertical Numerical Rating Scale supplemented with a Faces Rating Scale, and the short form of the Brief Pain Inventory. The secondary outcome measures were the upper-limb subscale of the Fugl-Meyer Assessment, and pain-free passive shoulder range of motion. All outcomes were measured pretreatment, post-treatment, and at 1-month after post-treatment. Two-way mixed repeated measures ANOVAs were used to examine treatment effects. RESULTS: Compared to TENS with bilateral arm training, the EMG-triggered NMES with bilateral arm training was associated with lower pain intensity during active and passive shoulder movement (P =0.007, P =0.008), lower worst pain intensity (P = 0.003), and greater pain-free passive shoulder abduction (P =0.001) and internal rotation (P =0.004) at follow-up. Both groups improved in pain at rest (P =0.02), pain interference with daily activities, the Fugl-Meyer Assessment, and pain-free passive shoulder flexion and external rotation post-treatment (P < 0.001) and maintained the improvement at follow-up (P < 0.001), except for resting pain (P =0.08). CONCLUSIONS: EMG-triggered NMES with bilateral arm training exhibited greater immediate and retained effects than TENS with bilateral arm training with respect to pain and shoulder impairment for chronic and subacute stroke patients with hemiplegic shoulder pain. TRIAL REGISTRATION: NCT01913509 .


Assuntos
Terapia por Estimulação Elétrica/métodos , Dor de Ombro/etiologia , Dor de Ombro/terapia , Reabilitação do Acidente Vascular Cerebral/métodos , Acidente Vascular Cerebral/complicações , Idoso , Eletromiografia , Feminino , Hemiplegia/etiologia , Hemiplegia/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Método Simples-Cego , Resultado do Tratamento
2.
Health Qual Life Outcomes ; 13: 91, 2015 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-26122080

RESUMO

BACKGROUND: Poststroke fatigue is a persistent and distressing symptom among stroke survivors. In this study, we investigated the reliability and validity of a vertical numerical rating scale supplemented with a faces rating scale (NRS-FRS) in measuring poststroke fatigue. METHODS: The fatigue intensity of 106 individuals with stroke was measured twice, 1 week apart, using a vertical NRS-FRS to measure test-retest reliability. The intraclass correlation coefficient, a relative reliability index, was calculated to examine the degree of consistency and agreement between the two test occasions. Absolute reliability indices, including the standard error of measurement, minimal detectable change, and Bland-Altman limits of agreement, were used to quantify measurement errors and determine systematic biases of the two test occasions. We also administered the vertical NRS concurrently as a comparator measure for assessing fatigue in 50 consecutive patients with stroke who were recruited later in the study period. The Spearman rank correlation coefficient (ρ) was used to examine the concurrent validity of the NRS-FRS. Discriminant validity was assessed by means of receiver operating characteristic curves, sensitivity, and specificity. RESULTS: The intraclass correlation coefficient was 0.95 for the NRS-FRS. The standard error of measurement and the minimal detectable change at the 95 % confidence interval of the NRS-FRS were 0.50 and 1.39, respectively. The Bland-Altman analyses showed no significant systematic bias between the repeated measurements. A narrow range of the limits of agreement was shown on the Bland-Altman plot, indicating the NRS-FRS had high stability and low variation between the two test occasions. The correlations between the NRS-FRS and NRS were good at test (ρ = 0.85) and retest (ρ = 0.84). Compared with the NRS cutoff value of ≥1, sensitivity with the NRS-FRS at test and retest was 94 and 92 % and specificity was 79 and 90 %, respectively. CONCLUSIONS: This study provides further evidence of the reliability and validity of the NRS-FRS in measuring fatigue intensity in patients with stroke. The NRS-FRS had high sensitivity and specificity. The NRS-FRS may be a reliable and valid measure for clinicians and researchers to assess fatigue and determine whether a real change has occurred in groups and at the individual level of patients with stroke.


Assuntos
Expressão Facial , Fadiga/diagnóstico , Qualidade de Vida/psicologia , Acidente Vascular Cerebral/psicologia , Inquéritos e Questionários/normas , Adulto , Idoso , Viés , Fadiga/psicologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Medição da Dor/métodos , Psicometria , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Acidente Vascular Cerebral/complicações
3.
J Phys Ther Sci ; 27(2): 421-5, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25729182

RESUMO

[Purpose] The purpose of this study was to investigate the effects of a forced-use training program on gait, mobility and quality of life of post-acute stroke patients. [Subjects] Twenty-one individuals with unilateral stroke participated in this study. All participants had suffered from first-ever stroke with time since onset of at least 3 months. [Methods] A single-blinded, non-equivalent, pre-post controlled design with 1-month follow-up was adopted. Participants received either a forced-use or a conventional physical therapy program for 2 weeks. The main outcomes assessed were preferred and fastest walking velocities, spatial and temporal symmetry indexes of gait, the timed up and go test, the Rivermead Mobility Index, and the Stroke-Specific Quality of Life Scale (Taiwan version). [Results] Forced-use training induced greater improvements in gait and mobility than conventional physical therapy. In addition, compared to pre-training, patients in the conventional physical therapy group walked faster but more asymmetrically after training. However, neither program effectively improved in-hospital quality of life. [Conclusion] The forced-use approach can be successfully applied to the lower extremities of stroke patients to improve mobility, walking speeds and symmetry of gait.

4.
Disabil Rehabil ; 26(18): 1105-9, 2004 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-15371036

RESUMO

PURPOSE: This study describes an eyeglass-type infrared-based communication board for the nonspeaking with quadriplegia. METHOD: This system is composed of four major components: a headset, an infrared transmitting module, an infrared receiving/signal-processing module, and a main controller, the Intel-8951 microprocessor. This design concept was based on the use of an infrared remote module fastened to the eyeglasses which could allow the convenient control of the input motion on the keys of a communication board, which are all modified with infrared receiving/signal-processing modules. For system evaluation, 12 subjects (all men, 21-45 years old, six normal subjects as the control group and six nonspeaking with quadriplegia as the experimental group) were recruited. RESULTS: The average accuracy of the control group and the experimental group were 93.1 +/- 4.3% and 89.7 +/- 5.5%, respectively. The average time cost of the control group and the experimental group were 78.3 +/- 8.7 s and 89.9 +/- 10.2 s, respectively. An independent t-test revealed that the differences in the average accuracy and the average time cost of the control group and the experimental group were not significant (p>0.05). CONCLUSIONS: The increase of opportunity to communicate using the infrared-based communication board would help people with multiple disabilities to socialize actively.


Assuntos
Auxiliares de Comunicação para Pessoas com Deficiência , Pessoas com Deficiência/reabilitação , Raios Infravermelhos , Quadriplegia/reabilitação , Adulto , Estudos de Casos e Controles , Desenho de Equipamento , Óculos , Humanos , Masculino , Microcomputadores , Pessoa de Meia-Idade , Processamento de Sinais Assistido por Computador , Estudos de Tempo e Movimento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA