Talanta ; 275: 126134, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38692044

RESUMO

Phosphoenolpyruvate (PEP) is an essential intermediate metabolite that is involved in various vital biochemical reactions. However, achieving the direct and accurate quantification of PEP in plasma or serum poses a significant challenge owing to its strong polarity and metal affinity. In this study, a sensitive method for the direct determination of PEP in plasma and serum based on ethylenediaminetetraacetic acid (EDTA)-facilitated hydrophilic interaction liquid chromatography-tandem mass spectrometry was developed. Superior chromatographic retention and peak shapes were achieved using a zwitterionic stationary-phase HILIC column with a metal-inert inner surface. Efficient dechelation of PEP-metal complexes in serum/plasma samples was achieved through the introduction of EDTA, resulting in a significant enhancement of the PEP signal. A PEP isotopically labelled standard was employed as a surrogate analyte for the determination of endogenous PEP, and validation assessments proved the sensitivity, selectivity, and reproducibility of this method. The method was applied to the comparative quantification of PEP in plasma and serum samples from mice and rats, as well as in HepG2 cells, HEK293T cells, and erythrocytes; the results confirmed its applicability in PEP-related biomedical research. The developed method can quantify PEP in diverse biological matrices, providing a feasible opportunity to investigate the role of PEP in relevant biomedical research.


Assuntos
Ácido Edético , Interações Hidrofóbicas e Hidrofílicas , Fosfoenolpiruvato , Espectrometria de Massas em Tandem , Espectrometria de Massas em Tandem/métodos , Animais , Humanos , Ácido Edético/química , Camundongos , Cromatografia Líquida/métodos , Ratos , Fosfoenolpiruvato/química , Fosfoenolpiruvato/sangue , Fosfoenolpiruvato/metabolismo , Células HEK293 , Células Hep G2 , Ratos Sprague-Dawley , Masculino
2.
Anal Biochem ; 685: 115388, 2024 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-37967783

RESUMO

The retrospective detection of organophosphorus nerve agents (OPNAs) exposure has been achieved by the off-site analysis of OPNA-human serum albumin (HSA) adducts using mass spectrometry-based detection approaches. However, few specific methods are accessible for on-site detection. To address this, a novel immunofluorescence microfluidic chip (IFMC) testing system combining europium chelated microparticle (EuCM) with self-driven microfluidic chip assay has been established to unambiguously determine soman (GD) and VX exposure within 20 min, respectively. The detection system was based on the principle of indirect competitive enzyme-linked immunosorbent assay. The specific monoclonal antibodies that respectively recognized the phosphonylated tyrosine 411 of GD-HSA and VX-HSA adducts were labeled by EuCM to capture corresponding adducts in the exposed samples. The phosphonylated peptides in the test line and goat-anti-rabbit antibody in the control line were utilized to bind the EuCM-labeled antibodies for signal exhibition. The developed IFMC chip could discriminatively detect exposed HSA adducts with high specificity, demonstrating a low limit of detection at exposure concentrations of 0.5 × 10-6 mol/L VX and 1.0 × 10-6 mol/L GD. The exposed serum samples can be qualitatively detected following an additional pretreatment procedure. This is a novel rapid detection system capable of discriminating GD and VX exposure, providing an alternative method for rapidly identifying OPNA exposure.


Assuntos
Soman , Animais , Humanos , Coelhos , Soman/metabolismo , Európio , Microfluídica , Estudos Retrospectivos , Albumina Sérica Humana , Imunofluorescência
3.
J Chromatogr A ; 1708: 464373, 2023 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-37717454

RESUMO

Ricin is a highly toxic protein toxin that poses a potential bioterrorism threat due to its potency and widespread availability. However, the accurate quantification of ricin through absolute mass spectrometry (MS) using a protein standard absolute quantification (PSAQ) strategy is not widely practiced. This limitation primarily arises from the presence of interchain disulfide bonds, which hinder the production of full-length isotope-labeled ricin as an internal standard (IS) in vitro. In this study, we have developed a novel approach for the absolute quantification of ricin in complex matrices using recombinant single-chain and full-length mutant ricin as the protein IS, instead of isotope-labeled ricin, in conjunction with ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). The amino acid sequence of the ricin mutant internal standard (RMIS) was designed by introducing site mutations in specific amino acids of trypsin/Glu-C enzymatic digestion marker peptides of ricin. To simplify protein expression, the A-chain and B-chain of RMIS were directly linked to replace the original interchain disulfide bonds. The RMISs were synthesized using an Escherichia coli expression system. An appropriate RMIS was selected as the protein IS based on consistent digestion efficiency, UHPLC-MS/MS behavior, antibody recognition function, lectin activity, and proper depurination activity with intact ricin. The RMIS was utilized to simultaneously quantify A- and B-chain marker peptides of ricin through UHPLC-MS/MS. This method was thoroughly validated using a milk matrix. By employing internal protein standards, this quantitative strategy overcomes the challenges posed by variations in extraction recoveries, matrix effects, and digestion efficiency encountered when working with different matrices. Consequently, calibration curves generated from milk matrix-spiked samples were utilized to accurately and precisely quantify ricin in river water and plasma samples. Moreover, the established method successfully detected intact ricin in samples obtained from the sixth Organization for the Prohibition of Chemical Weapons (OPCW) exercise on biotoxin analysis. This study presents a novel PSAQ strategy that enables the accurate quantification of ricin in complex matrices.


Assuntos
Ricina , Espectrometria de Massas em Tandem , Cromatografia Líquida de Alta Pressão , Sequência de Aminoácidos , Escherichia coli/genética , Dissulfetos
4.
J Chromatogr A ; 1697: 463990, 2023 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-37075496

RESUMO

Organophosphorus nerve agent (OPNA) adducts to butyrylcholinesterase (BChE) can be applied to confirm exposure in humans. A sensitive method for generic detection of G- and V-series OPNA adducts to BChE in plasma was developed by combining an improved procainamide-gel separation (PGS) and pepsin digestion protocol with ultra-high-pressure liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). Residual matrix interferences from prior PGS purification of OPNA-BChE adducts from plasma were found to be a critical cause of significantly reduced UHPLC-MS/MS detection sensitivity. In our developed on-column PGS approach, the matrix interference was successfully removed by adding an appropriate concentration of NaCl to the washing buffer, and it could capture ≥92.5% of the BChE in plasma. The lower pH value and the longer digestion time in all previous pepsin digestion methods were found to be a key accelerated aging factor of several adducts such as tabun (GA)-, cyclohexylsarin (GF)-, and soman (GD)-BChE nonapeptide adducts, making them difficult to detect. The aging event of several OPNA-BChE nonapeptide adducts was so successfully addressed that the formic acid level in enzymatic buffer and digestion time were lowered to 0.05% (pH 2.67) and 0.5 h, respectively, and the post-digestion reaction was immediately terminated. The improved condition parameters were optimal for pepsin digestion of all types of OPNA-BChE adducts into their individual unaged nonapeptide adducts with the highest yields, expanding the applicability of the method. The method had a nearly one-fold decrease in sample preparation time through the reduction of digestion time and removal of ultrafiltration procedure after digestion. The limit of identification (LOI) were determined respectively as 0.13 ng mL-1, 0.28 ng mL-1, 0.50 ng mL-1, 0.41 ng mL-1 and 0.91 ng mL-1 for VX-, sarin (GB)-, GA-, GF-, and GD-exposed human plasma, being low exposure value compared to previously documented approaches. The approach was utilized to fully characterize the adducted (aged and unaged) BChE levels of five OPNAs in a series of their individual exposed concentration (1.00-400 nM) of plasma sample, and successfully detect OPNA exposure from all unknown plasma samples from OPCW's second and third biomedical proficiency tests. The OPNA-BChE adducts, their aged adducts, and unadducted BChE from OPNA-exposed plasma can simultaneously be measured using the method. The study provides a recommended diagnostic tool for generic verification of any OPNA exposure with high confidence by detecting its corresponding BChE adduct.


Assuntos
Agentes Neurotóxicos , Humanos , Idoso , Agentes Neurotóxicos/análise , Butirilcolinesterase , Espectrometria de Massas em Tandem/métodos , Procainamida/análise , Pepsina A , Compostos Organofosforados , Cromatografia Líquida/métodos , Digestão
5.
J Chromatogr A ; 1671: 462990, 2022 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-35390735

RESUMO

The detection of Chemical Weapon Convention (CWC)-related amine compounds including the precursors or degradation products of V-type organophosphorus nerve agent, nitrogen mustard and 3-quinuclidinyl benzilate is an important aspect for verifying their intact chemical warfare agents. This work focuses on the development of a novel formulation for the simultaneous solvent extraction of eleven CWC-related amine compounds, from the four-type soil matrices including environmental standard soil, sand, clay, and loam. Extracts were well separated on the hydrophilic interaction liquid chromatography (HILIC) and then detected by MS/MS multiple reaction monitoring mode. The type and component of solvent mixtures were optimized to cover a wide range of polarity over all eleven amine compounds with high extraction efficiencies. Extraction parameters, such as the proportion of methanol, water and NH4OH, the times and the period of extraction, and volumes of extraction solution were optimized. The results indicated that a mixed solvent of methanol/water (44:53, v/v) in 3.0% NH4OH was the optimal formulation for extraction of all 11 analytes with high mean extraction recoveries (64.4-96.1%). Specificity and sensitivity were well improved by the good separation of 11 analytes from four-type soil matrices using these optimized HILIC parameters. This method was fully validated for each analyte in four soil matrices. The linear range of 11 analytes was 0.50/0.75-500 ng·g-1 with correlation coefficient (R2) ≥0.990, and intra/inter-day accuracies were 70.3-125% with relative standard deviation (RSD) ≤19.3%. Limit of detection (LOD) of 11 analytes ranged from 0.01 to 0.5 ng·g-1, which was far lower than those reported in previous studies. The built method accomplishes simultaneously quantitative and trace measurement of all eleven CWC-related amine compounds within a single solvent extraction and detection. It only takes a small amount of soil samples and possesses the highest sensitivity over all previous methods. This study provides an optional recommended operating procedure for determination of CWC-related amine compounds in four typical types of complex soils during chemical weapons verification.


Assuntos
Agentes Neurotóxicos , Espectrometria de Massas em Tandem , Aminas , Cromatografia Líquida de Alta Pressão , Cromatografia Líquida , Interações Hidrofóbicas e Hidrofílicas , Metanol , Compostos Organofosforados , Solo/química , Extração em Fase Sólida , Solventes , Água
6.
J Hazard Mater ; 424(Pt B): 127536, 2022 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-34879527

RESUMO

Atmospheric pressure plasma jet (APPJ) were used to decontaminate the surface's 2-Chloroethyl ethyl sulfide (2-CEES), a kind of sulfur mustard (HD) simulant. The power of the APPJ device didn't exceed 7.77 W. Helium APPJ was easier to generate plasma jet than argon APPJ. The treated nude mouse skin surface's temperature slowly reached 30.4 °C and no obvious lesions in the dermis and skin appendages after 15 min treatment. Compared with argon APPJ, the helium APPJ produced more ·OH and the maximum concentration of ·OH was 3.748 × 10-9 mol/L. Attributed to the low density and more ·OH content, the helium APPJ had a better decontamination effect. With a maximum voltage of 7 kV and a helium flow rate of 4 L/min, 2-CEES (4.53 mg/cm2) can be completely decontaminated in 2.5 min, and no gaseous 2-CEES was detected. The detection of the 2-Hydroxyethyl ethyl sulfide proved the role of ·OH in the reaction system. During the reaction, 2-Chloroethyl ethyl sulfoxide and 2-Chloroethyl ethyl sulfone were also detected. The plasma jet could reduce the toxicity by destroying the parent molecule (2-CEES) in a short time, but it took more time to eliminate the intermediate products. No relevant intermediate products were detected in the gaseous, ensured the safety of personnel operating in open spaces.


Assuntos
Gás de Mostarda , Animais , Pressão Atmosférica , Descontaminação , Camundongos , Gás de Mostarda/análogos & derivados , Gás de Mostarda/toxicidade , Pele
7.
Se Pu ; 39(3): 260-270, 2021 Mar.
Artigo em Chinês | MEDLINE | ID: mdl-34227307

RESUMO

Type Ⅱ ribosome-inactivating proteins (RIPs) are an important class of protein toxins that consist of A and B chains linked by an interchain disulfide bond. The B-chain with lectin-like activity is responsible for binding to the galactose-containing receptors on eukaryotic cell surfaces, which is essential for A-chain internalization by endocytosis. The A-chain has N-glycosidase activity that irreversibly depurinates a specific adenine from 28S ribosomal RNA (28S rRNA) and terminates protein synthesis. The synergistic effect of the A-B chain inactivates the ribosome, inhibits protein synthesis, and exhibits high cytotoxicity. Ricin and abrin that are expressed by the plants Ricinus communis and Abrus precatorius, respectively, are typical type Ⅱ RIPs. The toxicity of ricin and abrin are 385 times and 2885 times, respectively, more that of the nerve agent VX. Owing to their ease of preparation, wide availability, and potential use as a bioterrorism agent, type Ⅱ RIPs have garnered increasing attention in recent years. Ricin is listed as a prohibited substance under schedule 1A of the Chemical Weapons Convention (CWC). The occurrence of ricin-related bioterrorism incidents in recent years has promoted the development of accurate, sensitive, and rapid detection and identification technology for type Ⅱ RIPs. Significant progress has been made in the study of toxicity mechanisms and detection methods of type Ⅱ RIPs, which primarily involve qualitative and quantitative analysis methods including immunological assays, mass spectrometry analysis methods, and toxin activity detection methods based on depurination and cytotoxicity. Immunoassays generally involve the specific recognition of antigens and antibodies, which is based on oligonucleotide molecular recognition elements called aptamers. These methods are fast and highly sensitive, but for highly homologous proteins in complex samples, they provide false positive results. With the rapid development of biological mass spectrometry detection technology, techniques such as electrospray ionization (ESI) and matrix-assisted laser desorption ionization (MALDI) are widely used in the identification of proteins. These methods not only provide accurate information on molecular weight and structure of proteins, but also demonstrate accurate quantification. Enzyme digestion combined with mass spectrometry is the predominantly used detection method. Accurate identification of protein toxins can be achieved by fingerprint analysis of enzymatically digested peptides. For analysis of protein toxins in complex samples, abundant peptide markers are obtained using a multi-enzyme digestion strategy. Targeted mass spectrometry analysis of peptide markers is used to obtain accurate qualitative and quantitative information, which effectively improves the accuracy and sensitivity of the identification of type Ⅱ RIP toxins. Although immunoassay and mass spectrometry detection methods can provide accurate identification of type Ⅱ RIPs, they cannot determine whether the toxins will retain potency. The widely used detection methods for activity analysis of type Ⅱ RIPs include depurination assay based on N-glycosidase activity and cytotoxicity assay. Both the methods provide simple, rapid, and sensitive analysis of type Ⅱ RIP toxicity, and complement other detection methods. Owing to the importance of type Ⅱ RIP toxins, the Organization for the Prohibition of Chemical Weapons (OPCW) has proposed clear technical requirements for the identification and analysis of relevant samples. We herein reviewed the structural characteristics, mechanism of action, and the development and application of type Ⅱ RIP detection methods; nearly 70 studies on type Ⅱ RIP toxins and their detection methods have been cited. In addition to the technical requirements of OPCW for the unambiguous identification of biotoxins, the trend of future development of type Ⅱ RIP-based detection technology has been explored.


Assuntos
Abrina , Proteínas Inativadoras de Ribossomos/análise , Ricina , Abrina/análise , Proteínas de Plantas/análise , Ribossomos , Ricina/análise , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz
8.
Toxins (Basel) ; 13(5)2021 05 18.
Artigo em Inglês | MEDLINE | ID: mdl-34069935

RESUMO

The high toxic abrin from the plant Abrus precatorius is a type II ribosome-inactivating protein toxin with a human lethal dose of 0.1-1.0 µg/kg body weight. Due to its high toxicity and the potential misuse as a biothreat agent, it is of great importance to developing fast and reliable methods for the identification and quantification of abrin in complex matrices. Here, we report rapid and efficient acetonitrile (ACN)- and ultrasound-assisted on-bead trypsin digestion method combined with HPLC-MS/MS for the quantification of abrin isoforms in complex matrices. Specific peptides of abrin isoforms were generated by direct ACN-assisted trypsin digestion and analyzed by HPLC-HRMS. Combined with in silico digestion and BLASTp database search, fifteen marker peptides were selected for differential detection of abrin isoforms. The abrin in milk and plasma was enriched by immunomagnetic beads prepared by biotinylated anti-abrin polyclonal antibodies conjugated to streptavidin magnetic beads. The ultrasound-assisted on-bead trypsin digestion method was carried out under the condition of 10% ACN as denaturant solvent, the entire digestion time was further shortened from 90 min to 30 min. The four peptides of T3Aa,b,c,d, T12Aa, T15Ab, and T9Ac,d were chosen as quantification for total abrin, abrin-a, abrin-b, and abrin-c/d, respectively. The absolute quantification of abrin and its isoforms was accomplished by isotope dilution with labeled AQUA peptides and analyzed by HPLC-MS/MS (MRM). The developed method was fully validated in milk and plasma matrices with quantification limits in the range of 1.0-9.4 ng/mL for the isoforms of abrin. Furthermore, the developed approach was applied for the characterization of abrin isoforms from various fractions from gel filtration separation of the seeds, and measurement of abrin in the samples of biotoxin exercises organized by the Organization for the Prohibition of Chemical Weapons (OPCW). This study provided a recommended method for the differential identification of abrin isoforms, which are easily applied in international laboratories to improve the capabilities for the analysis of biotoxin samples.


Assuntos
Abrina/análise , Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas em Tandem/métodos , Abrina/química , Abrina/isolamento & purificação , Abrus/química , Animais , Cromatografia Líquida , Simulação por Computador , Leite , Isoformas de Proteínas , Coelhos , Toxinas Biológicas , Tripsina/metabolismo , Ultrassom
9.
Toxicol Lett ; 344: 46-57, 2021 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-33705862

RESUMO

Sulfur mustard (SM) is a blister chemical warfare agent with severe cytotoxicity and genotoxicity. It can extensively alkylate important macromolecules in organisms, such as proteins, DNA, and lipids, and produce a series of metabolites, among which the characteristic ones can be used as biomarkers. The exact toxicological mechanisms of SM remain unclear but mainly involve the DNA lesions induced by alkylation and oxidative stress caused by glutathione depletion. Various methods have been used to analyze DNA damage caused by SM. Among these methods, liquid chromatography-tandem mass spectrometry (LC-MS/MS) technology stands out and makes it possible to observe damage in view of biomarkers induced by SM. Sample preparation is critical for detection by LC-MS/MS and mainly includes DNA isolation, adduct hydrolysis, and adduct purification. Moreover, optimization of chromatographic conditions, selection of MS transitions, and quantitative strategies are also essential. SM-DNA adducts are generally considered to be N7-HETEG, O6-HETEG, N7-BisG, and N3-HETEA. This article proposes some other possibilities of SM-DNA adducts for the identification of SM genotoxicity.


Assuntos
Substâncias para a Guerra Química/toxicidade , Adutos de DNA , Gás de Mostarda/toxicidade , Animais , Biomarcadores/sangue , Humanos
10.
J Proteome Res ; 20(1): 369-380, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-33108200

RESUMO

Ricin is a type II ribosome-inactivating protein toxin consisting of A and B chains linked by one interchain disulfide bond. Because of its high toxicity depending on both chains together, confirming the presence of both A and B chains of intact ricin is required during the investigation of the illegal production and application. Here, we report a novel and sensitive acetonitrile (ACN)-assisted trypsin digestion method for unambiguous identification of intact ricin by simultaneous detection of its marker peptides from A and B chains. Marker peptides were generated with a simple procedure by direct cleaving the native ricin at 45 °C for 4 h using Promega modified sequencing grade trypsin under the assistance of 10% ACN, and then directly analyzed by ultrahigh performance liquid chromatography tandem mass spectrometry. The type of trypsin was found to be one critical factor for cleavage of intact ricin based on a significant difference in the yields of specific peptides generated while using various types of trypsin. A low content of ACN in enzymatic buffer significantly reduced the digestion time from overnight to 4 h. There was commonly a better MS response of marker peptides when using the developed ACN-assisted trypsin digestion method than methanol-assisted trypsin digestion within the same 4 h. Totally, seven specific peptides with high sensitivity and specificity including three in the A-chain (TA7, TA11, and TA10) and four in the B-chain (TB6, TB14-ss-TB16, TB20, and TB18) were obtained as good marker peptides for unambiguous identification of intact ricin. The lowest concentration of native ricin for unambiguous identification was 20 ng/mL, in which three marker peptides from both the A-chain and B-chain could be measured with a minimum of three ion transitions. Combined with affinity enrichment, the developed approach was successfully applied for the measurement of intact ricin from the complicated matrix samples of the second, third, and fourth biotoxin exercises organized by the Organisation for the Prohibition of Chemical Weapons (OPCW). This study has provided a recommended detection method combined with one novel ACN-assisted trypsin digestion with MS for forensic unambiguous confirmation of trace ricin intact with high confidence.


Assuntos
Ricina , Acetonitrilas , Cromatografia Líquida , Digestão , Peptídeos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Espectrometria de Massas em Tandem , Tripsina
11.
Anal Bioanal Chem ; 413(2): 585-597, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33184759

RESUMO

The toxic protein of ricin has drawn wide attention in recent years as a potential bioterrorism agent due to its high toxicity and wide availability. For the verification of the potential anti-terrorism activities, it is urgent for the quantification of ricin in food-related matrices. Here, a novel strategy of trypsin/Glu-C tandem digestion was introduced for quantitative detection of ricin marker peptides in several beverage matrices using isotope-labeled internal standard (IS)-mass spectrometry. The ricin in beverages was captured and enriched by biotinylated anti-ricin polyclonal antibodies conjugated to streptavidin magnetic beads. The purified ricin was cleaved using the developed trypsin/Glu-C tandem digestion method and then quantitatively detected by ultra-high-pressure liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) with isotope-labeled T7A and TG11B selected as IS. The use of trypsin/Glu-C digestion allows shorter peptides, which are more suitable for MS detection, to be obtained than the use of single trypsin digestion. Under the optimized tandem digestion condition, except for T7A in the A-chain, two resulting specific peptides of TG13A, TG28A from the A-chain and two of TG11B, TG33B from the B-chain were chosen as novel marker peptides with high MS response. The uniqueness of the selected marker peptides allows for unambiguous identification of ricin among its homologous proteins in a single run. The MS response of the four novel marker peptides is increased by more than 10 times compared with that of individual corresponding tryptic peptides. Both the marker peptides of A-chain T7A and B-chain TG11B were selected as quantitative peptides based on the highest MS response among the marker peptides from their individual chains. The limit of detection (LOD) of ricin is 0.1 ng/mL in PBS and 0.5 ng/mL in either milk or orange juice. The linear range of calibration curves for ricin were 0.5-300 ng/mL in PBS, 1.0-400 ng/mL in milk, and 1.0-250 ng/mL in orange juice. The method accuracy ranged between 82.6 and 101.8% for PBS, 88.9-105.2% for milk, and 95.3-118.7% for orange juice. The intra-day and inter-day precision had relative standard deviations (%RSD) of 0.3-9.4%, 0.7-8.9%, and 0.2-6.9% in the three matrices respectively. Furthermore, whether T7A or TG11B is used as a quantitative peptide, the quantitative results of ricin are consistent. This study provides not only a practical method for the absolute quantification of ricin in beverage matrices but also a new strategy for the investigation of illegal use of ricin in chemical weapon verification tasks such as OPCW biotoxin sample analysis exercises.


Assuntos
Bebidas/análise , Cromatografia Líquida de Alta Pressão/métodos , Ricina/análise , Espectrometria de Massas em Tandem/métodos , Tripsina/análise , Biotinilação , Calibragem , Marcação por Isótopo , Limite de Detecção , Magnetismo , Peptídeos/química , Controle de Qualidade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Solventes , Estreptavidina/análise
12.
Toxins (Basel) ; 11(7)2019 07 05.
Artigo em Inglês | MEDLINE | ID: mdl-31284465

RESUMO

Both ricin and R. communisagglutinin (RCA120), belonging to the type II ribosome-inactivating proteins (RIPs-Ⅱ), are derived from the seeds of the castor bean plant. They share very similar amino acid sequences, but ricin is much more toxic than RCA120. It is urgently necessary to distinguish ricin and RCA120 in response to public safety. Currently, mass spectrometric assays are well established for unambiguous identification of ricin by accurate analysis of differentiated amino acid residues after trypsin digestion. However, diagnostic peptides are relatively limited for unambiguous identification of trace ricin, especially in complex matrices. Here, we demonstrate a digestion strategy of multiple proteinases to produce novel peptide markers for unambiguous identification of ricin. Liquid chromatography-high resolution MS (LC-HRMS) was used to verify the resulting peptides, among which only the peptides with uniqueness and good MS response were selected as peptide markers. Seven novel peptide markers were obtained from tandem digestion of trypsin and endoproteinase Glu-C in PBS buffer. From the chymotrypsin digestion under reduction and non-reduction conditions, eight and seven novel peptides were selected respectively. Using pepsin under pH 1~2 and proteinase K digestion, six and five peptides were selected as novel peptide markers. In conclusion, the obtained novel peptides from the established digestion methods can be recommended for the unambiguous identification of ricin during the investigation of illegal use of the toxin.


Assuntos
Peptídeos/análise , Ricina/química , Sequência de Aminoácidos , Cromatografia Líquida , Quimotripsina/química , Endopeptidase K/química , Espectrometria de Massas , Pepsina A/química , Peptídeos/química , Solventes/química , Tripsina/química
13.
Anal Bioanal Chem ; 411(15): 3405-3415, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31011788

RESUMO

Sulfur mustard (HD) reacts with human serum albumin (HSA) at Cys34 and produces a long-term biomarker of HD exposure. Here, we present a novel, sensitive, and convenient method for quantification of HD exposure by detection of HD-HSA adducts using pronase digestion, benzyl chloroformate (Cbz-Cl) derivatization, and ultra-high-pressure liquid chromatography tandem mass spectrometry (UHPLC-MS/MS). The HSA in HD-exposed plasma in vitro was precipitated with acetone and digested (2 h, 50 °C) with pronase to form the alkylated dipeptide, S-hydroxyethylthioethyl-CysPro (HETE-CP). The HETE-CP adduct was derivatized with Cbz-Cl to generate N-carbobenzoxy HETE-CP (HETE-C(Cbz)P). The derivatized product was analyzed by UHPLC-MS/MS. HD surrogate, 2-chloroethyl ethyl sulfide (2-CEES), was introduced as a non-isotope internal standard (ISTD) instead of traditional d8-HD for quantification. The method was found to be linear between 1.00 and 200 ng/mL HD exposure (R2 > 0.998) with precision of ≤ 9.0% relative standard deviation (RSD) and accuracy ranged between 97.1 and 111%. The limit of detection (LOD) is 0.500 ng/mL (S/N~5), over 15 times lower than that of the previous method (7.95 ng/mL). Time-consuming affinity purification or solid phase extraction (SPE) is not needed in the experiment and the operation takes less than 5 h. This study provides a new strategy and useful tool for retrospective analysis of HD exposure by HETE-CP biomarker detection. Graphical abstract Flow diagram for quantification of sulfur mustard exposure by detection of HETE-CP dipeptide adduct after benzyl chloroformate derivatization using ultra-high-pressure liquid chromatography tandem mass spectrometry.


Assuntos
Substâncias para a Guerra Química/análise , Cromatografia Líquida de Alta Pressão/métodos , Gás de Mostarda/análise , Espectrometria de Massas em Tandem/métodos , Alquilação , Biomarcadores/análise , Biomarcadores/sangue , Precipitação Química , Dipeptídeos/análise , Formiatos/química , Humanos , Limite de Detecção , Pronase/química , Proteólise , Albumina Sérica Humana/análise , Extração em Fase Sólida/métodos
14.
J Chromatogr A ; 1492: 41-48, 2017 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-28284764

RESUMO

Four HD urinary metabolites including hydrolysis metabolite thiodiglycol (TDG), glutathione-derived metabolite 1,1'-sulfonylbis[2-S-(N-acetylcysteinyl)ethane] (SBSNAE), as well as the ß-lyase metabolites 1,1'-sulfonylbis[2-(methylsulfinyl)ethane] (SBMSE) and 1-methylsulfinyl-2-[2-(methylthio) ethylsulfonyl]ethane (MSMTESE) are considered as important biomarkers for short-term retrospective detection of HD exposure. In this study, a single method for simultaneous quantification of the four HD metabolites in urine samples was developed using ultra high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). The four urinary metabolites were simultaneously extracted from urinary samples using a solid phase extraction (SPE) method with high extraction recoveries for all four metabolites varied in the range of 71.1-103% followed by UHPLC-MS/MS analysis. The SPE is simple and high effective only requiring 0.1mL of urinary samples and 0.5h time consuming. The problem of previous co-elution of TDG and SBSNAE in UHPLC was well solved, and complete separation of TDG, SBSNAE, SBMSE and MSMTESE from SPE-processed urine matrix was obtained to increase specificity and sensitivity. A full method validation was performed for each analyte in urine matrix. The linear range of calibration curves for the four analytes were respectively from 0.50-500ngmL-1 for TDG and SBSNAE, 0.05-500ngmL-1 for SBMSE and MSMTESE with coefficient of determination value (R2) ≥0.990. The limit of detection was 0.25ngmL-1 for TDG and SBSNAE, 0.01ngmL-1 for SBMSE and MSMTESE spiked in normal urine. The intra/inter-day precision for each analyte at three QC levels had relative standard deviation (%RSD) of ≤10.3%, and the intra/inter-day accuracy ranged between 88.0-108%. This developed method allows for simultaneous and trace measurement of four HD urinary metabolites within one single determination with the lowest usage amount of urine samples over all previous methods This study provides a useful tool for early diagnosis and monitoring of HD poisoning for medical treatment with high confidence, avoiding the need for application of several analysis methods.


Assuntos
Substâncias para a Guerra Química/metabolismo , Gás de Mostarda/metabolismo , Acetatos/química , Biomarcadores/urina , Substâncias para a Guerra Química/análise , Substâncias para a Guerra Química/isolamento & purificação , Cromatografia Líquida de Alta Pressão , Humanos , Gás de Mostarda/análise , Gás de Mostarda/isolamento & purificação , Reprodutibilidade dos Testes , Extração em Fase Sólida , Compostos de Sulfidrila/isolamento & purificação , Compostos de Sulfidrila/urina , Espectrometria de Massas em Tandem
15.
J Chromatogr B Analyt Technol Biomed Life Sci ; 1036-1037: 57-65, 2016 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-27718463

RESUMO

This work describes a novel and sensitive non-isotope dilution method for simultaneous quantification of organophosphorus nerve agents (OPNAs) soman (GD) and VX adducts to butyrylcholinesterase (BChE), their aged methylphosphonic acid (MeP) adduct and unadducted BChE in plasma exposed to OPNA. OPNA-BChE adducts were isolated with an off-column procainamide-gel separation (PGS) from plasma, and then digested with pepsin into specific adducted FGES*AGAAS nonapeptide (NP) biomarkers. The resulting NPs were detected by UHPLC-MS/MS MRM. The off-column PGS method can capture over 90% of BChE, MeP-BChE, VX-BChE and GD-BChE from their respective plasma materials. One newly designed and easily synthesized phosphorylated BChE nonapeptide with one Gly-to-Ala mutation was successfully reported to serve as internal standard instead of traditional isotopically labeled BChE nonapeptide. The linear range of calibration curves were from 1.00-200ngmL-1 for VX-NP, 2.00-200ngmL-1 for GD-NP and MeP-NP (R2≥0.995), and 3.00-200ngmL-1 for BChE NP (R2≥0.990). The inter-day precision had relative standard deviation (%RSD) of <8.89%, and the accuracy ranged between 88.9-120%. The limit of detection was calculated to be 0.411, 0.750, 0.800 and 1.43ngmL-1 for VX-NP, GD-NP, MeP-NP and BChE NP, respectively. OPNA-exposed quality control plasma samples were characterized as part of method validation. Investigation of plasma samples unexposed to OPNA revealed no baseline values or interferences. Using the off-column PGS method combined with UHPLC-MS/MS, VX-NP and GD-NP adducts can be unambiguously detected with high confidence in 0.10ngmL-1 and 0.50ngmL-1 of exposed human plasma respectively, only requiring 0.1mL of plasma sample and taking about four hours without special sample preparation equipment. These improvements make it a simple, sensitive and robust PGS-UHPLC-MS/MS method, and this method will become an attractive alternative to immunomagnetic separation (IMS) method and a useful diagnostic tool for retrospective detection of OPNA exposure with high confidence. Furthermore, using the developed method, the adducted BChE levels from VX and GD-exposed (0.10-100ngmL-1) plasma samples were completely characterized, and the fact that VX being more active and specific to BChE than GD was re-confirmed.


Assuntos
Butirilcolinesterase/sangue , Substâncias para a Guerra Química/farmacocinética , Inibidores da Colinesterase/sangue , Compostos Organofosforados/sangue , Compostos Organotiofosforados/sangue , Soman/sangue , Espectrometria de Massas em Tandem/métodos , Butirilcolinesterase/isolamento & purificação , Inibidores da Colinesterase/isolamento & purificação , Cromatografia Líquida de Alta Pressão/instrumentação , Cromatografia Líquida de Alta Pressão/métodos , Desenho de Equipamento , Géis/química , Humanos , Limite de Detecção , Compostos Organofosforados/isolamento & purificação , Compostos Organotiofosforados/isolamento & purificação , Procainamida/química , Soman/isolamento & purificação , Espectrometria de Massas em Tandem/instrumentação
16.
Anal Bioanal Chem ; 407(23): 7037-46, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26164303

RESUMO

Sulfur mustard (HD) adduct to human serum albumin (ALB) at Cys-34 residue has become an important and long-term retrospective biomarker of HD exposure. Here, a novel, sensitive, and convenient approach for retrospective quantification of HD concentration exposed to plasma was established by detection of the HD-ALB adduct using ultra-high pressure liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) with a novel non-isotope internal standard (IS). The HD-ALB adduct was isolated from HD-exposed plasma with blue Sepharose. The adduct was digested with proteinase K to form sulfur-hydroxyethylthioethyl ([S-HETE])-Cys-Pro-Phe tripeptide biomarker. The tripeptide adduct could be directly analyzed by UHPLC-MS/MS without an additional solid phase extraction (SPE), which was considered as a critical procedure in previous methods. The easily available 2-chloroethyl ethylsulfide (2-CEES) as HD surrogate was first reported to be used as IS in place of traditional d8-HD for quantification of HD exposure. Furthermore, 2-CEES was also confirmed to be a good IS alternative for quantification of HD exposure by investigation of product ion spectra for their corresponding tripeptide adducts which exhibited identical MS/MS fragmentation behaviors. The method was found to be linear between 1.00 and 250 ng•mL(-1) HD exposure (R(2)>0.9989) with precision of <4.50% relative standard deviation (%RSD), accuracy range between 96.5% and 114%, and a calculated limit of detection (LOD) of 0.532 ng•mL(-1). The lowest reportable limit (LRL) is 1.00 ng•mL(-1), over seven times lower than that of the previous method. The entire method required only 0.1 mL of plasma sample and took under 7 h without special sample preparation equipment. It is proven to be a sensitive, simple, and rugged method, which is easily applied in international laboratories to improve the capabilities for the analysis of biomedical samples related to verification of the Chemical Weapon Convention (CWC).


Assuntos
Análise Química do Sangue/métodos , Cromatografia Líquida de Alta Pressão/métodos , Exposição Ambiental/análise , Gás de Mostarda/análise , Albumina Sérica/análise , Espectrometria de Massas em Tandem/métodos , Bioensaio , Substâncias para a Guerra Química , Humanos , Ligação Proteica , Mapeamento de Interação de Proteínas , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
17.
Xi Bao Yu Fen Zi Mian Yi Xue Za Zhi ; 30(10): 1095-8, 2014 Oct.
Artigo em Chinês | MEDLINE | ID: mdl-25270215

RESUMO

OBJECTIVE: To develop a high sensitive and specific method for the detection of abrin. METHODS: The abrin monoclonal antibody (mAb) 7D1 coated with Fe3O4 magnetic nanoparticles (MNPs) and abrin mAb labeled with horseradish peroxidase (HRP-mAb) were used to establish the immunocapturing method for abrin detection. The results were compared with the traditional double antibody sandwich ELISA. RESULTS: The detecting linear of immunocapture for abrin was 2.5-60 ng/mL, and the linear regression equation was y=0.012x-0.015 with the detection limit of 2.5 ng/mL. Ricin at different concentrations did not interfere the abrin detection results, which demonstrated that the method had a good specificity . This approach showed good reproducibility with relative standard deviation ranging from 5.18%-8.67%. It could be used for analyzing abrin-contaminated specimens such as water, beverage, and milk, etc. The results of comparison with the conventional double antibody sandwich ELISA indicated that the immunocapture have a broader linear scale, higher sensitivity, and a shorter detection time. CONCLUSION: The developed immunocapturing method can be used for detecting traces of abrin.


Assuntos
Abrina/análise , Anticorpos Monoclonais/química , Técnicas Imunológicas/métodos , Nanopartículas de Magnetita/química , Abrina/imunologia , Abrus/química , Anticorpos Monoclonais/imunologia , Ensaio de Imunoadsorção Enzimática/métodos , Reprodutibilidade dos Testes , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA