1.
Rev Sci Instrum ; 93(11): 113103, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36461454

RESUMO

In this study, we propose a hybrid coded-aperture and Compton camera based on cerium-doped Gd3Al2Ga3O12 (GAGG:Ce) scintillator arrays coupled with Multi-Pixel Photon Counter (MPPC) arrays. The sensitive detector of the gamma camera consists of a single GAGG:Ce crystal coupled with a single-chip MPPC unit module. An impedance bridge circuit and a 64-channel data acquisition system were employed to record the code-aperture events and Compton coincidence events. After the calibration of position and energy, the total energy resolution for 662 keV gamma-rays from 137Cs was 6.6%. The hybrid camera had the characteristics of mechanical collimation and electronic collimation at the same time. In the code aperture mode, the reconstructed images were obtained by direct deconvolution and maximum likelihood expectation maximization (MLEM) methods. In the Compton imaging mode, the energy-dependent method was applied to order the sequence of Compton scatter events. The simple back-projection algorithm and list-mode MLEM algorithm were adopted for image reconstruction. Practical performances demonstrated that the angular resolutions in two modes were measured as 5.2° and 11.4°, respectively. In addition, the hybrid camera had a desirable imaging capability in a wide energy range (32 keV-2.6 MeV) and a wide field of view (∼210° in the horizontal direction). As for the sensitivity, the camera had a commercially available sensitivity level of localizing a 137Cs point source, producing ∼0.026 µSv/h in 5 min. Furthermore, the function of distinction for different radiation sources was preliminarily realized.

2.
Rev Sci Instrum ; 92(1): 013106, 2021 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-33514237

RESUMO

A 50 × 50 × 10 mm3 monolithic gadolinium aluminum gallium garnet (Gd3Al2Ga3O12; GAGG):Ce crystal coupled to a 8 × 8 silicon photomultiplier (SiPM) array was developed; it showed very good system uniformity and a high energy resolution of 7.4% at 662 keV. By using a convolutional neural network-based positioning algorithm and a fan-beam calibration method, the detector achieved a position resolution of ∼1.4 mm and a depth of interaction resolution of ∼2 mm. Based on this high-performance monolithic detector, we developed a coded aperture gamma camera. A 1-mCi Cs-137 source centered at a 2-m distance from the mask could be reconstructed with a signal-to-noise ratio of 6.5 in 1 s. Furthermore, the imaging ability of a low-energy Am-241 source and a low-activity Cs-137 source when the background-to-signal ratio was approximately 1:1 and a double low-activity source (Cs-137 and Na-22) was demonstrated. It is shown that the monolithic-crystal-based coded aperture gamma camera can achieve high performance and has a large potential for further improvement.

3.
Opt Express ; 27(5): 7160-7173, 2019 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-30876285

RESUMO

In spectroscopy, the compositional analysis of the spectrum is important, such as extracting information about the species of spectral objects contributing to spectral data from an emission spectrum of photon energy. A quantitative spectral component analysis method based on Maximum Likelihood Estimation using Expectation Maximization (MLEM) is developed, which could quantitatively decompose out the components of the measured spectrum of low counts and surpass conventional techniques which belong to classification or regression. Abundant experimental and simulated spectra data on gamma-ray spectrum of radionuclides are presented to demonstrate and evaluate this method, while the ingredient radionuclides in the mixed spectrum are identified accurately with high precision. It will be a powerful and alternative method recommended for the circumstances needing fast and quantitative spectral analysis, including radionuclide identification (gamma-ray spectra), biomass or mineral composition (near-infrared spectra), laser-induced breakdown spectra and other spectroscopy scenarios.