RESUMO
INTRODUCTION: Right phrenic nerve palsy (PNP) is a typical complication of cryoballoon ablation of the right-sided pulmonary veins (PVs). Phrenic nerve function can be monitored by palpating the abdomen during phrenic nerve pacing from the superior vena cava (SVC pacing) or by fluoroscopy of spontaneous breathing. We sought to compare the sensitivity of these 2 techniques during cryoballoon ablation for detection of PNP. METHODS AND RESULTS: A total of 133 patients undergoing cryoballoon ablation were monitored with both SVC pacing and fluoroscopy of spontaneous breathing during ablation of the right superior PV. PNP occurred in 27/133 patients (20.0%). Most patients (89%) had spontaneous recovery of phrenic nerve function at the end of the procedure or on the following day. Three patients were discharged with persistent PNP. All PNP were detected first by fluoroscopic observation of diaphragm movement during spontaneous breathing, while diaphragm could still be stimulated by SVC pacing. In patients with no recovery until discharge, PNP occurred at a significantly earlier time (86 ± 34 seconds vs. 296 ± 159 seconds, P < 0.001). No recovery occurred in 2/4 patients who were ablated with a 23 mm cryoballoon as opposed to 1/23 patients with a 28 mm cryoballoon (P = 0.049). CONCLUSION: Fluoroscopic assessment of diaphragm movement during spontaneous breathing is more sensitive for detection PNP as compared to SVC pacing. PNP as assessed by fluoroscopy is frequent (20.0%) and carries a high rate of recovery (89%) until discharge. Early onset of PNP and use of 23 mm cryoballoon are associated with PNP persisting beyond hospital discharge.
Assuntos
Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Diafragma/inervação , Monitorização Intraoperatória/métodos , Paralisia/diagnóstico , Traumatismos dos Nervos Periféricos/diagnóstico , Nervo Frênico/lesões , Veias Pulmonares/cirurgia , Respiração , Adulto , Idoso , Pontos de Referência Anatômicos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Estimulação Elétrica , Feminino , Fluoroscopia , Humanos , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Palpação , Paralisia/diagnóstico por imagem , Paralisia/etiologia , Paralisia/fisiopatologia , Alta do Paciente , Traumatismos dos Nervos Periféricos/diagnóstico por imagem , Traumatismos dos Nervos Periféricos/etiologia , Traumatismos dos Nervos Periféricos/fisiopatologia , Nervo Frênico/fisiopatologia , Nervo Frênico/cirurgia , Valor Preditivo dos Testes , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/fisiopatologia , Recuperação de Função Fisiológica , Fatores de Risco , Fatores de Tempo , Resultado do TratamentoRESUMO
PURPOSE: Identification of reliable risk factors for recurrence of atrial fibrillation (AF) after pulmonary vein isolation (PVI) has important implications. Left atrial (LA) pressure is a largely observator-independent parameter that can easily be determined after transseptal puncture. The purpose of this study was to investigate the predictive value of LA pressure for AF recurrence after PVI. METHODS: Two hundred five consecutive patients with paroxysmal or persistent AF scheduled for first PVI were included. Baseline clinical data were collected. During PVI, LA pressure was determined invasively after transseptal puncture. PVI was performed with radiofrequency or cryoenergy, and patients were followed for 25 ± 7 months. RESULTS: One hundred five (51 %) patients had AF recurrence. Patients with persistent AF prior to ablation had significantly more recurrences than patients with paroxysmal AF (70.1 vs. 42.0 %, p < 0.001). Mean LA pressure was significantly higher in patients with recurrence of AF (13.4 ± 7.1 vs. 11.0 ± 5.2 mmHg, p = 0.007), as was mean LA volume index (40.1 ± 18.5 vs. 33.0 ± 11.2 mL/m(2), p < 0.001). In the multivariate analysis, mean LA pressure was predictive in patients with normal or mildly enlarged LA, while AF type was not predictive. For each 1-mmHg increase in LA pressure, the risk of AF recurrence increased by 11 % in this subgroup. In patients with moderately or severely enlarged LA, AF type was predictive whereas LA pressure was not. CONCLUSION: LA pressure, AF type, and LA volume index are independent predictors for recurrence of AF after PVI. LA pressure may be helpful especially in patients with small atria, where AF type is not predictive.
Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Pressão Atrial , Determinação da Pressão Arterial/estatística & dados numéricos , Sistema de Condução Cardíaco/cirurgia , Veias Pulmonares/cirurgia , Fibrilação Atrial/epidemiologia , Determinação da Pressão Arterial/métodos , Feminino , Alemanha/epidemiologia , Átrios do Coração , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Recidiva , Reprodutibilidade dos Testes , Medição de Risco , Fatores de Risco , Sensibilidade e Especificidade , Resultado do TratamentoRESUMO
BACKGROUND: Little is known about the prevalence of upper extremity vein obstruction or anomalies in patients before first implantation of implantable cardioverter defibrillator (ICD). It remains unclear in which patients contrast venography is warranted before implantation procedure. METHODS: Results of clinical data and contrast venography of 302 consecutive patients scheduled for first ICD implantation were analyzed. RESULTS: Prevalence of upper vein obstruction was 6.6% (20/302 patients) in a typical patient population undergoing first ICD implantation. Age, left ventricular ejection fraction, underlying heart disease, prior open-heart surgery, or cardiopulmonary resuscitation were not predictors of obstruction. Patients with previous cardiac pacemaker implantation had a higher rate of obstruction, though this was not statistically significant (20% vs 15.7%, P = 0.54). Persistent left vena cava was found in 0.7%. CONCLUSION: There is no clinical parameter sufficient enough to predict upper extremity venous obstruction. Contrast venography may be considered in patients with previous pacemaker placement but should not be a routine diagnostic tool in unselected patients prior to first ICD-implantation procedure.
Assuntos
Desfibriladores Implantáveis/estatística & dados numéricos , Falha de Prótese , Implantação de Prótese/estatística & dados numéricos , Extremidade Superior/irrigação sanguínea , Insuficiência Venosa/epidemiologia , Feminino , Alemanha/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Medição de Risco , Fatores de RiscoRESUMO
AIMS: We compared a newly developed irrigated gold tip electrode ablation catheter and a gold tip 4 and 8 mm catheter with the corresponding platinum-iridium (Pt) tip catheters in an in vitro setting. METHODS AND RESULTS: In a flow chamber simulating physiological flow conditions, radiofrequency catheter ablation was performed on tissue samples of porcine endomyocardium and liver. Lesion depth, energy and temperature delivery, and popping frequency were determined. Two hundred and fifty-three ablations were conducted. Four and eight millimetre, gold tip electrode catheters produced significantly deeper lesions compared with the Pt tip electrode (liver 4 mm: 4.67 +/- 1.7 vs. 2.9 +/- 1.0 mm, P < 0.0001; endomyocardium 4 mm: 3.88 +/- 1.1 vs. 2.81 +/- 0.7 mm, P < 0.001; liver 8 mm: 3.98 +/- 1.0 vs. 2.03 +/- 1.1 mm, P < 0.001; endomyocardium 8 mm: 4.00 +/- 0.9 vs. 3.39 +/- 0.8 mm, P < 0.001) and correlated with the amount of energy delivery. Popping frequency was significantly higher in gold tip electrodes. In irrigated tip electrodes, there was no difference in the lesion depth comparing gold with Pt (liver: 5.18 +/- 0.7 vs. 5.01 +/- 0.7 mm, P = ns; endomyocardium: 4.89 +/- 0.7 vs. 4.78 +/- 0.8 mm, P = ns). There was a trend towards less popping in the gold tip electrode. CONCLUSION: Both 4 and 8 mm not-irrigated gold tip catheters produced deeper lesions than the corresponding Pt tip catheter. In irrigated tip catheters, gold and Pt tip material did not show differences in the lesion depth.
Assuntos
Ablação por Cateter/instrumentação , Ablação por Cateter/métodos , Ouro , Irídio , Platina , Animais , Procedimentos Cirúrgicos Cardíacos/instrumentação , Procedimentos Cirúrgicos Cardíacos/métodos , Eletrodos , Técnicas In Vitro , Fígado/cirurgia , Modelos Animais , SuínosRESUMO
Catheter ablation has emerged as an excellent treatment option for atrial fibrillation. In appropriate patients, particularly those with paroxysmal atrial fibrillation in the absence of structural heart disease, catheter-based pulmonary vein isolation can eliminate or dramatically reduce the arrhythmia burden. However, with currently available tools, the procedure is complex and labor intensive. Simpler ablation procedures may emerge as newer ablation systems are developed.