Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Eur Spine J ; 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38584244

RESUMO

PURPOSE: The PDDD is a ratchet-based, unidirectional expandable rod to treat adolescent idiopathic scoliosis (AIS), primarily by correcting scoliotic deformity without full spinal fusion. We hypothesized that the device will be fully tolerated by the host and, if aseptic screw loosening occurs, it will be unrelated to wear particle formation. METHODS: This study comprised tissue samples from seven patients from a prospective study (NCT04296903) to assess the PDDD's safety and benefits, reoperated due to complications. Host response was assessed from histological slides (four levels/implant) in accordance with GLP and ISO10993-6:2016. The elementary chemical composition of wear particles present in tissue sections was quantified by energy dispersive X-ray spectroscopy (EDX). RESULTS: Host reaction was minor, characterized by low levels of diverse inflammatory cells, mild fibrosis, occasional small necrotic foci, neovascularization, hemorrhage, and, rarely, small bone fragments. Twenty-four of 28 tissue sections displayed varying degrees of wear particles (black discoloration), and most sections (17) were scored as 1 (< 25% of the sample). The discoloration observed corresponded to black-appearing, fine granular pigment. EDX analysis confirmed particles were composed of titanium, aluminum, and vanadium. Twenty-six of 28 samples were scored zero for necrosis and 2/28 were scored 1. Eleven samples were scored zero for fibrosis, 12 as 1, and five as 2. No aseptic screw loosening occurred. CONCLUSION: The PDDD induced minimal host reaction with little or no degeneration, inflammation or fibrosis. No changes present could be expected to promote device failure. The PDDD implant for treating AIS is well-tolerated and locally safe.

2.
Cancers (Basel) ; 13(19)2021 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-34638352

RESUMO

(1) Background: Proton minibeam radiation therapy (pMBRT) is a new radiotherapy technique using spatially modulated narrow proton beams. pMBRT results in a significantly reduced local tissue toxicity while maintaining or even increasing the tumor control efficacy as compared to conventional radiotherapy in small animal experiments. In all the experiments performed up to date in tumor bearing animals, the dose was delivered in one single fraction. This is the first assessment on the impact of a temporal fractionation scheme on the response of glioma-bearing animals to pMBRT. (2) Methods: glioma-bearing rats were irradiated with pMBRT using a crossfire geometry. The response of the irradiated animals in one and two fractions was compared. An additional group of animals was also treated with conventional broad beam irradiations. (3) Results: pMBRT delivered in two fractions at the biological equivalent dose corresponding to one fraction resulted in the highest median survival time, with 80% long-term survivors free of tumors. No increase in local toxicity was noted in this group with respect to the other pMBRT irradiated groups. Conventional broad beam irradiations resulted in the most severe local toxicity. (4) Conclusion: Temporal fractionation increases the therapeutic index in pMBRT and could ease the path towards clinical trials.

3.
Cancers (Basel) ; 13(6)2021 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-33802835

RESUMO

(1) Background: among all types of radiation, very heavy ions, such as Neon (Ne) or Argon (Ar), are the optimum candidates for hypoxic tumor treatments due to their reduced oxygen enhancement effect. However, their pioneering clinical use in the 1970s was halted due to severe side effects. The aim of this work was to provide a first proof that the combination of very heavy ions with minibeam radiation therapy leads to a minimization of toxicities and, thus, opening the door for a renewed use of heavy ions for therapy; (2) Methods: mouse legs were irradiated with either Ne MBRT or Ne broad beams at the same average dose. Skin toxicity was scored for a period of four weeks. Histopathology evaluations were carried out at the end of the study; (3) Results: a significant difference in toxicity was observed between the two irradiated groups. While severe da-mage, including necrosis, was observed in the broad beam group, only light to mild erythema was present in the MBRT group; (4) Conclusion: Ne MBRT is significantly better tolerated than conventional broad beam irradiations.

4.
Adv Healthc Mater ; 7(21): e1800338, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30221474

RESUMO

Ti-based bulk metallic glasses are under consideration for implants due to their high yield strength and biocompatibility. In this work, in situ synchrotron X-ray diffraction (XRD) is used to investigate the corrosion products formed from corrosion of Ti40 Zr10 Cu34 Pd14 Sn2 bulk metallic glass in artificial corrosion pits in physiological saline (NaCl). It is found that Pd nanoparticles form in the interior of the pits during electrochemical dissolution. At a low pit growth potential, the change in lattice parameter of the Pd nanoparticles is consistent with the formation of palladium hydride. In addition, a salt layer very close to the dissolving interface is found to contain CuCl, PdCl2 , ZrOCl2 ∙8H2 O, Cu, Cu2 O, and several unidentified phases. The formation of Pd nanoparticles (16 ± 10 nm at 0.7 V vs Ag/AgCl) containing small amounts of the other alloying elements is confirmed by transmission electron microscopy. The addition of albumin and/or H2 O2 does not significantly influence the nature of the corrosion products. When considering the biological compatibility of the alloy, the biological reactivity of the corrosion products identified should be explored.


Assuntos
Materiais Biocompatíveis/química , Titânio/química , Difração de Raios X/métodos , Ligas/química , Corrosão , Eletrólitos , Microscopia Eletrônica de Transmissão , Síncrotrons
5.
Materials (Basel) ; 11(2)2018 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-29415490

RESUMO

Ti40Zr10Cu36Pd14 Bulk Metallic Glass (BMG) appears very attractive for future biomedical applications thanks to its high glass forming ability, the absence of toxic elements such as Ni, Al or Be and its good mechanical properties. For the first time, a complete and exhaustive characterization of a unique batch of this glassy alloy was performed, together with ISO standard mechanical tests on machined implant-abutment assemblies. The results were compared to the benchmark Ti-6Al-4V ELI (Extra-Low-Interstitial) to assess its potential in dental implantology. The thermal stability, corrosion and sterilization resistance, cytocompatibility and mechanical properties were measured on samples with a simple geometry, but also on implant-abutment assemblies' prototypes. Results show that the glassy alloy exhibits a quite high thermal stability, with a temperature range of 38 °C between the glass transition and crystallization, a compressive strength of 2 GPa, a certain plastic deformation (0.7%), a hardness of 5.5 GPa and a toughness of 56 MPa.√m. Moreover, the alloy shows a relatively lower Young's modulus (96 GPa) than the Ti-6Al-4V alloy (110-115 GPa), which is beneficial to limit bone stress shielding. The BMG shows a satisfactory cytocompatibility, a high resistance to sterilization and a good corrosion resistance (corrosion potential of -0.07 V/SCE and corrosion current density of 6.0 nA/cm²), which may ensure its use as a biomaterial. Tests on dental implants reveal a load to failure 1.5-times higher than that of Ti-6Al-4V and a comparable fatigue limit. Moreover, implants could be machined and sandblasted by methods usually conducted for titanium implants, without significant degradation of their amorphous nature. All these properties place this metallic glass among a promising class of materials for mechanically-challenging applications such as dental implants.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA