Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Mikrochim Acta ; 191(7): 400, 2024 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-38879615

RESUMO

Ultrathin molecularly imprinted polymer (MIP) films were deposited on the surfaces of ZnO nanorods (ZNRs) and nanosheets (ZNSs) by electropolymerization to afford extended-gate field-effect transistor sensors for detecting phenytoin (PHT) in plasma. Molecular imprinting efficiency was optimized by controlling the contents of functional monomers and the template in the precursor solution. PHT sensing was performed in plasma solutions with various concentrations by monitoring the drain current as a function of drain voltage under an applied gate voltage of 1.5 V. The reliability and reproducibility of the fabricated sensors were evaluated through a solution treatment process for complete PHT removal and PHT adsorption-removal cycling, while selectivity was examined by analyzing responses to chemicals with structures analogous to that of PHT. Compared with the ZNS/extracted-MIP sensor and sensors with non-imprinted polymer (NIP) films, the ZNR/extracted-MIP sensor showed superior responses to PHT-containing plasma due to selective PHT adsorption, achieving an imprinting factor of 4.23, detection limit of 12.9 ng/mL, quantitation limit of 53.0 ng/mL, and selectivity coefficients of 3-4 (against tramadol) and ~ 5 (against diphenhydramine). Therefore, we believe that the MIP-based ZNR sensing platform is promising for the practical detection of PHT and other drugs and evaluation of their proper dosages.


Assuntos
Anticonvulsivantes , Limite de Detecção , Polímeros Molecularmente Impressos , Fenitoína , Transistores Eletrônicos , Óxido de Zinco , Anticonvulsivantes/sangue , Anticonvulsivantes/análise , Polímeros Molecularmente Impressos/química , Óxido de Zinco/química , Fenitoína/sangue , Fenitoína/análise , Fenitoína/química , Humanos , Impressão Molecular , Nanotubos/química , Adsorção , Reprodutibilidade dos Testes , Polímeros/química
2.
Mikrochim Acta ; 190(7): 265, 2023 06 19.
Artigo em Inglês | MEDLINE | ID: mdl-37336828

RESUMO

Novel detection method has been developed to explore changes in mechanical bending angles on a bilayer of polyethylene terephthalate (PET) and molecularly imprinted polymer (MIP). For an ovalbumin (OVA)-imprinted hydrogel layer, functional monomers were employed to achieve sufficient binding effect in the polymer matrix. The OVA amount added in the MIP precursor solution and the dimensions of OVA-imprinted hydrogel (MIH) strips were controlled to maximize the change in bending angles as an OVA sensing response within a valid detection range. The sensing behaviors were determined by monitoring the difference in the bending angles via protein adsorption based on the swelling-induced deformation of the OVA-extracted hydrogel (E-MIH) strip. The equilibrium adsorption capacity of the E-MIH strip was calculated via the Bradford protein assay. The detection limit, quantification limit, and imprinting factor were calculated. To compare the selectivity coefficients, the adsorption behaviors of three proteins were investigated. Finally, the reusability of the E-MIH strip was explored via repeated adsorption and extraction. Based on the results, the E-MIH strips demonstrated a promising protein sensing platform monitoring mechanical bending angles affected by swelling deformation.


Assuntos
Hidrogéis , Proteínas , Ovalbumina , Polímeros , Polímeros Molecularmente Impressos
3.
ACS Sens ; 8(6): 2298-2308, 2023 06 23.
Artigo em Inglês | MEDLINE | ID: mdl-37261931

RESUMO

In this study, a chalcone-branched polyimide (CB-PI) was synthesized by the Steglich esterification reaction for selective recognition of the toxic peptide melittin (MEL). MEL was immobilized on a nanopatterned poly(dimethylsiloxane) (PDMS) mold using a conventional surface modification technique to increase binding sites. A stripe-nanopatterned thin CB-PI film was formed on a quartz crystal (QC) substrate by simultaneously performing microcontact printing and ultraviolet (UV) light dimerization using a MEL-immobilized mold. The surface morphology changes and dimensions of the molecularly imprinted polymer (MIP) films with stripe nanopatterns (S-MIP) were analyzed using scanning electron microscopy (SEM) and atomic force microscopy (AFM). The sensing signals (Δf and Qe) of the S-MIP sensor were investigated upon adsorption in a 100-µL dilute plasma solution containing 30 µg/mL MEL, and its reproducibility, reuse, stability, and durability were investigated. The S-MIP sensor showed high sensitivity (5.49 mL/mg) and coefficient of determination (R2 = 0.999), and the detection limit (LOD) and the quantification limit (LOQ) were determined as 0.3 and 1.1 µg/mL, respectively. In addition, the selectivity coefficients (k*) calculated from the selectivity tests were 2.7-5.7, 2.1-4.3, and 2.8-4.6 for bovine serum albumin (BSA), immunoglobulin G (IgG), and apamin (APA), respectively. Our results indicate that the nanopatterned MIP sensors based on CB-PI demonstrate great potential as a sensing tool for the quantitative analysis of biomolecules.


Assuntos
Chalconas , Impressão Molecular , Impressão Molecular/métodos , Meliteno , Técnicas de Microbalança de Cristal de Quartzo/métodos , Reprodutibilidade dos Testes , Polímeros/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA