Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38757909

RESUMO

INTRODUCTION: Left bundle branch area (LBBA) pacing (LBBAP) has been proposed as an alternative therapy option in patients indicated for cardiac pacing to treat bradycardia or heart failure. The aim of the study was to evaluate the safety and effectiveness of LBBAP in patients implanted with a Tendril 2088 stylet-driven lead. METHODS: The international retrospective data collection registry included 11 sites from 5 countries globally. Patients with attempted implants of the Tendril lead in the LBBA were followed for at least 6 months post the implant attempt. The primary safety and efficacy endpoints were freedom from LBBAP lead-related serious adverse events and the composite of LBBA capture threshold of ≤2.0 V and R-wave amplitudes ≥5 mV (or ≥value at implant), respectively. RESULTS: Of 221 patients with attempted implants of the Tendril 2088 lead in the LBBA, 91.4% (202/221) had successful implants for LBBAP. Regardless of the LBBAP implant success, all patients were followed for at least 6 months (8.7 ± 7.3 months). Baseline characteristics: 44% female, 84% ≥65 years old, 34% coronary artery disease, and 86% of primary indications for pacemaker implant. Both primary safety and effectiveness endpoints were met (freedom from LBBAP lead-related serious adverse device effects of 99.5% and electrical performance composite success rate of 93%). The capture thresholds in LBBAP at implant and 6 months were 0.8 ± 0.3 V@0.4 ± 0.1 ms and 0.8 ± 0.3 V@0.4 ± 0.1 ms. The rate of patients with capture threshold rise ≥1 V was 1.5% through 6 months. The R-wave amplitudes in LBBAP at implant and 6 months were 9.3 ± 3.2 mV and 10.6 ± 3.0 mV. CONCLUSIONS: This large multicenter study demonstrates that the stylet-driven Tendril™ STS 2088 lead is safe and effective for LBBAP with high success and low complication rates.

2.
Expert Opin Drug Metab Toxicol ; 16(9): 837-851, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32729743

RESUMO

INTRODUCTION: Statins have been established as the standard of care for dyslipidemia and preventing cardiovascular diseases while posing few safety concerns. However, misconceptions about statin intolerance lead to their underuse, indicating a need to improve the understanding of the safety of this treatment. AREAS COVERED: We searched PubMed and reviewed literatures related to statin intolerance published between February 2015 and February 2020. Important large-scale or landmark studies published before 2015 were also cited as key evidence. EXPERT OPINION: Optimal lowering of low-density lipoprotein cholesterol with statins substantially reduces the risk of cardiovascular events. Muscle adverse events (AEs) were the most frequently reported AEs by statin users in clinical practice, but they usually occurred at a similar rate with statins and placebo in randomized controlled trials and had a spurious causal relationship with statin treatment. We proposed a rigorous definition for identifying true statin intolerance and present the criteria for defining different forms of muscle AEs and an algorithm for their management. True statin intolerance is uncommon, and every effort should be made to exclude false statin intolerance and ensure optimal use of statins. For the management of statin intolerance, statin-based approaches should be prioritized over non-statin approaches.


Assuntos
Dislipidemias/tratamento farmacológico , Inibidores de Hidroximetilglutaril-CoA Redutases/administração & dosagem , Doenças Musculares/induzido quimicamente , Algoritmos , Doenças Cardiovasculares/etiologia , Doenças Cardiovasculares/prevenção & controle , LDL-Colesterol/sangue , Dislipidemias/complicações , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/efeitos adversos , Doenças Musculares/diagnóstico
3.
Singapore Med J ; 58(7): 408-410, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28740998

RESUMO

Therapeutic temperature management (TTM) was strongly recommended by the 2015 International Liaison Committee on Resuscitation as a component of post-resuscitation care. It has been known to be effective in improving the survival rate and neurologic functional outcome of patients after cardiac arrest. In an effort to increase local adoption of TTM as a standard of post-resuscitation care, this paper discusses and makes recommendations on the treatment for local providers.


Assuntos
Parada Cardíaca/terapia , Hipertermia Induzida , Adulto , Temperatura Corporal , Reanimação Cardiopulmonar , Parada Cardíaca/fisiopatologia , Humanos , Hipertermia Induzida/efeitos adversos , Hipertermia Induzida/métodos
4.
Singapore Med J ; 56(10): 580-5, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26512151

RESUMO

Transvenous implantable cardioverter defibrillators are a type of implantable cardiac device. They are effective at reducing total and arrhythmic mortality in patients at risk of sudden cardiac death. Subcutaneous implantable cardioverter defibrillators (S-ICDs) are a new alternative that avoids the disadvantages of transvenous lead placement. In this case series, we report on the initial feasibility and safety of S-ICD implantation in Singapore.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/estatística & dados numéricos , Adulto , Eletrofisiologia , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Segurança do Paciente , Implantação de Prótese , Singapura , Taquicardia Ventricular , Fibrilação Ventricular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA