Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
Pacing Clin Electrophysiol ; 44(10): 1724-1732, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34449092

RESUMO

BACKGROUND: Atrial fibrillation (AF) prevalence increases with age. Aging affects the substrate properties of the left atrium (LA) and the outcomes of catheter ablation for treating AF. We investigated the AF trigger distribution and catheter ablation outcomes in patients of different ages with AF. METHODS: 1585 patients with AF (1181 paroxysmal and 404 non- paroxysmal AF) who had undergone catheter ablation were enrolled. The patients were divided into young (20-40 year-old, n = 175), middle-aged (41-64 year-old, n = 1134), and old (≥ 65 year-old, n = 276) groups. Electrophysiological characteristics and AF trigger sites were recorded. RESULT: The incidence of AF with only non-pulmonary vein (non-PV) foci was higher in the young group than in the other groups (8.6% vs. 3.6% vs. 3.3%, p < 0.01). Non-PV foci were more commonly located in the superior vena cava (SVC) in the young group than in the other groups (13.1% vs. 7.8% vs. 6.5%, p = 0.03). The left atrium (LA) mean voltage was higher and the incidence of very late recurrence after AF ablation was lower in the young group than in the other groups. However, the final AF recurrence rate after multiple procedures and complication rates were similar among all the groups at a mean follow-up of 5.6 years. CONCLUSION: The young patients with AF had a higher incidence of only non-PV foci, mostly located in SVC, than the middle-aged and old patients. Our study highlights the importance of identifying the non-PV foci in catheter ablation of young patients with AF.


Assuntos
Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Adulto , Fatores Etários , Idoso , Técnicas Eletrofisiológicas Cardíacas , Feminino , Átrios do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva
2.
J Cardiovasc Transl Res ; 14(2): 348-354, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-32557157

RESUMO

This study aimed to investigate the electromechanical function detected by acoustic cardiography before and after radiofrequency ablation therapy (RFA) in paroxysmal AF (PAF) patients with preserved left ventricular ejection fraction (LVEF). Seventy-five symptomatic PAF patients and 69 patients without arrhythmia were enrolled. Thirty-seven PAF patients received RFA therapy. Acoustic cardiographic exam was performed to check S3 and S4 heart sound, electromechanical activation time (EMAT), LV systolic time percentage (LVST), and systolic dysfunction index (SDI) in all participants. Furthermore, 37 PAF patients also received follow-up acoustic cardiography postRFA. PAF had impaired electromechanical systolic function compared with health participants (%EMAT 14.69 ± 3.62 vs. 10.84 ± 2.62; %LVST 40.83 ± 5.14 vs. 36.70 ± 3.87; SDI 4.75 ± 1.61 vs. 3.26 ± 0.96 all p < 0.001). RFA can improve electromechanical systolic function. Improvement below 13.1% could predict the recurrent AF postcatheter ablation. Higher degree of improved electromechanical systolic function postRFA contribute to lower recurrence of AF. Graphical Abstract Receiver operating characteristic (ROC) curve analysis for % change of systolic dysfunction index (SDI) postRFA in the detection of recurrent AF.


Assuntos
Acústica , Potenciais de Ação , Fibrilação Atrial/diagnóstico , Auscultação Cardíaca , Função Ventricular Esquerda , Remodelação Ventricular , Adulto , Idoso , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Estudos de Casos e Controles , Ablação por Cateter/efeitos adversos , Eletrocardiografia , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Recidiva , Medição de Risco , Fatores de Risco , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento
3.
J Cardiovasc Electrophysiol ; 31(6): 1436-1447, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32227530

RESUMO

INTRODUCTION: Accurate identification of slow conducting regions in patients with scar-related atrial tachycardia (AT) is difficult using conventional electrogram annotation for cardiac electroanatomic mapping (EAM). Estimating delays between neighboring mapping sites is a potential option for activation map computation. We describe our initial experience with CARTO 3 Coherent Mapping (Biosense Webster Inc,) in the ablation of complex ATs. METHODS: Twenty patients (58 ± 10 y/o, 15 males) with complex ATs were included. We created three-dimensional EAMs using CARTO 3 system with CONFIDENSE and a high-resolution mapping catheter (Biosense Webster Inc). Local activation time and coherent maps were used to aid in the identification of conduction isthmus (CI) and focal origin sites. System-defined slow or nonconducting zones and CI, defined by concealed entrainment (postpacing interval < 20 ms), CV < 0.3 m/s and local fractionated electrograms were evaluated. RESULTS: Twenty-six complex ATs were mapped (mean: 1.3 ± 0.7 maps/pt; 4 focal, 22 isthmus-dependent). Coherent mapping was better in identifying CI/breakout sites where ablation terminated the tachycardia (96.2% vs 69.2%; P = .010) and identified significantly more CI (mean/chamber 2.0 ± 1.1 vs 1.0 ± 0.7; P < .001) with narrower width (19.8 ± 10.5 vs 43.0 ± 23.9 mm; P < .001) than conventional mapping. Ablation at origin and CI sites was successful in 25 (96.2%) with long-term recurrence in 25%. CONCLUSIONS: Coherent mapping with conduction velocity vectors derived from adjacent mapping sites significantly improved the identification of CI sites in scar-related ATs with isthmus-dependent re-entry better than conventional mapping. It may be used in conjunction with conventional mapping strategies to facilitate recognition of slow conduction areas and critical sites that are important targets of ablation.


Assuntos
Potenciais de Ação , Cicatriz/complicações , Técnicas Eletrofisiológicas Cardíacas , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca , Taquicardia Supraventricular/diagnóstico , Idoso , Algoritmos , Ablação por Cateter , Cicatriz/diagnóstico , Feminino , Sistema de Condução Cardíaco/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Projetos Piloto , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador , Taquicardia Supraventricular/etiologia , Taquicardia Supraventricular/fisiopatologia , Taquicardia Supraventricular/cirurgia , Fatores de Tempo , Resultado do Tratamento
4.
Circ J ; 83(7): 1449-1455, 2019 06 25.
Artigo em Inglês | MEDLINE | ID: mdl-31118363

RESUMO

BACKGROUND: Telomere length is a biologic aging marker. This study investigated leukocyte telomere length (LTL) as a new biomarker to predict recurrence after paroxysmal atrial fibrillation (PAF) ablation.Methods and Results:A total of 131 participants (26 healthy individuals and 105 symptomatic PAF patients) were enrolled. PAF patients (54.1±10.8 years) who received catheter ablation therapy were divided into 2 groups: recurrent AF (n=25) and no recurrent AF after catheter ablation (n=80). Peripheral blood mononuclear cells were collected from all subjects to measure LTL. Under 50 years old, LTL in healthy individuals (n=17) was longer than in PAF patients (n=31; 7.34±0.58 kbp vs. 6.44±0.91 kbp, P=0.01). In PAF patients, LTL was positively correlated with left atrial bipolar voltage (R=0.497, P<0.001), and negatively correlated with biatrial scar area (R=-0.570, P<0.001) and left atrial diameter (R=-0.214, P=0.028). LTL was shorter in the patients with recurrent AF than in those without recurrent AF after catheter ablation (5.68±0.82 kbp vs. 6.66±0.71 kbp; P<0.001). On receiver operating characteristic curve analysis, LTL cut-off <6.14 kbp had a specificity of 0.68 and sensitivity of 0.79 to predict recurrent AF after catheter ablation. CONCLUSIONS: Young PAF patients (≤50 years) had shorter LTL. Shorter LTL was associated with a degenerative atrial substrate and recurrence after catheter ablation in younger PAF patients.


Assuntos
Fibrilação Atrial/metabolismo , Fibrilação Atrial/terapia , Remodelamento Atrial , Leucócitos/metabolismo , Ablação por Radiofrequência , Homeostase do Telômero , Adulto , Fatores Etários , Fibrilação Atrial/patologia , Feminino , Humanos , Leucócitos/patologia , Masculino , Pessoa de Meia-Idade
5.
Pacing Clin Electrophysiol ; 42(6): 637-645, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30900751

RESUMO

BACKGROUND: Premature ventricular contractions (PVCs) induced by subtle cardiac dysfunction are missed by echocardiography. We evaluated acoustic cardiography for detection of early electromechanical dysfunction in patients with idiopathic PVCs and normal left ventricular ejection fraction (LVEF), and investigated the impact of radiofrequency ablation (RFA) in reversing this adverse effect. METHODS: Eighty-six patients with PVCs and 33 normal controls having normal LVEF were studied. Fifty PVC patients were in the ablation group and 36 in the nonablation group. %Electromechanical activation time (%EMAT), %left ventricular systolic time (%LVST), third (S3) and fourth heart sound (S4), and systolic dysfunction index (SDI) during sinus rhythm (SR) were measured by acoustic cardiography (Audicor, Inovise Medical, Inc., Beaverton, OR, USA) pre- and postablation. In 28 patients, acoustic parameters were compared during SR without PVCs, and SR with single PVC, ≥ 2 PVCs, or ventricular tachycardia over 10-second Audicor recording in a single patient at different times. Twenty-four-hour acoustic cardiographic and acoustic cardiographic Holter recording were used to assess the impact of PVC burden on electromechanical function in 41 patients. RESULTS: %EMAT, S3, S4, and SDI showed significant worsening in the PVC versus control group. %EMAT and SDI were worsened with increasing PVC number in a 10-second strip. %EMAT showed significant linear increment with increasing PVC burden. There was a significant improvement in %EMAT, %LVST, S3, S4, and SDI postablation in patients with PVCs. CONCLUSION: Acoustic cardiography can detect PVC-induced minor electromechanical dysfunction in patients with normal LVEF. RFA can reverse this adverse effect.


Assuntos
Complexos Ventriculares Prematuros/fisiopatologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Ablação por Cateter , Diagnóstico Precoce , Eletrocardiografia Ambulatorial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complexos Ventriculares Prematuros/cirurgia
6.
J Arrhythm ; 34(4): 336-346, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30167004

RESUMO

Nonischemic cardiomyopathies (NICMs) are composed of variable disease entities, including primary and secondary cardiomyopathies. Determining the etiology of NICM provides pivotal roles of not only the understanding of the individual pathogenesis, but also the clinical management, such as risk stratification, pharmacological treatment, and intervention therapies. Despite the diverse causes of NICM, these cases mostly require clinical attention owing to progressive myocardial injury, resulting in ventricular dysfunction and heart failure. The interaction between the diseased ventricular substrates and systemic/neurophysiological factors contributes to the cornerstones responsible for ventricular arrhythmogenesis and sudden cardiac death (SCD). Prevention of SCD and diminishing ventricular tachyarrhythmias are the important mainstays for the management of NICM patients. Given the understanding of the abnormal ventricular substrates and advancement of navigation systems, radiofrequency catheter ablation (RFCA) has become an adjunctive or alternative strategy for NICM patients who experience drug-refractory ventricular tachycardias (VTs). Successful ablation can frequently be achieved at the expense of an epicardial intervention. A recent study has proven the survival benefits for NICM patients who are free from recurrent VTs after a successful RFCA, regardless of the New York Heart Association (NYHA) functional class status or left ventricular ejection fraction. Additionally, recent evidence has highlighted the better delineation of a diseased myocardium through the incorporation of cardiovascular magnetic resonance imaging (CMRI) and 3D mapping systems, which can facilitate the identification of critical ventricular arrhythmogenic substrates in NICM patients.

7.
J Interv Card Electrophysiol ; 53(2): 175-185, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29948583

RESUMO

PURPOSE: In spite of several proposed predictors for premature ventricular complex (PVC)-induced cardiomyopathy (PVC-CMP), the specific ECG features of idiopathic right ventricular outflow tract (RVOT) PVC-CMP remain unknown. METHODS: A total of 130 patients (49 males, mean age 44 years) with symptomatic and drug-refractory idiopathic RVOT PVCs undergoing radiofrequency catheter ablation (RFCA) were enrolled. The patients were categorized into two groups, including those with and without RVOT PVC-CMP (left ventricular ejection fraction (LVEF) < 50%, n = 25 and LVEF ≥ 50%, n = 105, respectively). The 12-lead PVC morphologies were assessed. RESULTS: Patients with RVOT PVC-CMP had a lower LVEF (42 ± 5% vs. 60 ± 7%, P < 0.01) and higher PVC burden (24 ± 14% vs. 15 ± 11%, P = 0.02) when compared to patients without RVOT PVC-CMP. The PVC features in those with PVC-CMP displayed a significantly wider QRS duration (143 ± 14 ms vs. 132 ± 17 ms, P < 0.01) and higher peak deflection index (PDI; 0.60 ± 0.07 vs. 0.55 ± 0.08, P < 0.01). A multivariate analysis demonstrated that the QRS duration (odds ratio (OR) 1.130, 95% confidence interval (CI) 1.020-1.253, P = 0.02) and PDI (OR 1.240, 95% CI 1.004-1.532, P = 0.04) were independently associated with RVOT PVC-CMP. Based on the receiver-operating characteristic analysis, a QRS duration > 139 ms and PDI > 0.57 could predict RVOT PVC-CMP (area under the curve (AUC) 0.710 and AUC 0.690, respectively). The elimination and suppression of PVCs by RFCA resulted in the recovery of the LVEF in RVOT PVC-CMP. CONCLUSIONS: The ECG parameters, including a wider QRS duration and higher PDI, could predict the development of RVOT PVC-CMP, which could be effectively treated by RFCA.


Assuntos
Mapeamento Potencial de Superfície Corporal/métodos , Cardiomiopatias/cirurgia , Ablação por Cateter/métodos , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem , Obstrução do Fluxo Ventricular Externo/cirurgia , Complexos Ventriculares Prematuros/cirurgia , Adulto , Área Sob a Curva , Cardiomiopatias/diagnóstico por imagem , Estudos de Coortes , Eletrocardiografia/métodos , Feminino , Seguimentos , Humanos , Masculino , Valor Preditivo dos Testes , Curva ROC , Estudos Retrospectivos , Medição de Risco , Fatores de Tempo , Resultado do Tratamento , Complexos Ventriculares Prematuros/diagnóstico por imagem
8.
J Interv Card Electrophysiol ; 52(2): 225-236, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29572717

RESUMO

PURPOSE: There are few reports describing ventricular arrhythmias (VAs) from the crux and the corresponding endocardial site, i.e., the basal inferior segment of the interventricular septum (IVS). We aimed to investigate a distinct clinical group of VAs arising from the endocardium at this area in patients with structural heart diseases (SHD). METHODS: We included 17 patients with SHD and clinically documented VAs. Thirteen patients underwent endocardial mapping only. Three patients underwent both epicardial and endocardial approaches and one had only epicardial mapping. Eighteen VAs were identified, 14 focal and 4 reentrant VAs, confirmed by entrainment. RESULTS: There were 2 VAs from the crux, 5 VAs from the corresponding endocardial site in the right ventricle (RV), and 11 from the site in the left ventricle (LV). Compared with the VAs from RV endocardium, VAs from LV endocardium had a higher R wave in V3 than V2 (V2R/V3R ratio, 1.83 ± 0.84 vs. 0.86 ± 0.38, P = 0.008) and a higher V3 transition ratio percentage (2.16 ± 2.07 vs. 0.58 ± 0.62, P = 0.008). Combining all 16 patients with endocardial mapping, there were also lower bipolar voltages (1.21 ± 1.05 vs. 3.10 ± 2.65 mv, P < 0.0001), lower unipolar voltages (4.05 ± 1.92 vs. 5.75 ± 2.90 mv, P < 0.0001), and longer local electrocardiogram (EGM) lateness (157.6 ± 47.9 vs.140.3 ± 52.5 ms, P = 0.0001) in the dominant chambers. CONCLUSIONS: In VAs from the crux and the corresponding endocardial site, the complete ECG V2R/V3R ratio and V3 transition ratio percentage could differentiate the VAs from the RV or LV endocardium. The lower unipolar, bipolar voltage mapping, and longer EGM lateness are helpful to identify the abnormal substrate in the endocardium in these patients.


Assuntos
Ablação por Cateter/métodos , Mapeamento Epicárdico/métodos , Septos Cardíacos/diagnóstico por imagem , Taquicardia Ventricular/terapia , Adulto , Idoso , Mapeamento Potencial de Superfície Corporal/métodos , Eletrofisiologia Cardíaca , Ablação por Cateter/mortalidade , Estudos de Coortes , Eletrocardiografia/métodos , Cardiopatias/diagnóstico por imagem , Cardiopatias/mortalidade , Cardiopatias/terapia , Septos Cardíacos/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Medição de Risco , Taxa de Sobrevida , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/mortalidade , Taiwan , Resultado do Tratamento
9.
J Cardiovasc Electrophysiol ; 29(1): 127-137, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28988456

RESUMO

INTRODUCTION: Various ECG algorithms have been proposed to identify the origin of idiopathic outflow tract (OT)-ventricular arrhythmia (VA). However, electrocardiographic features of failed and recurrent right ventricular outflow tract (RVOT) ablation of idiopathic OT-VAs have not been clearly elucidated. METHODS AND RESULTS: A total of 264 consecutive patients (mean age: 44.0 ± 13.0 years, 96 male) undergoing RVOT ablation for OT-VAs with a transition ≥V3 , including 241 patients (91.6%) with initially successful procedures and 23 patients (8.4%) with failed ablation. Detailed clinical characteristics and ECG features were analyzed and compared between the two groups. VAs with failed RVOT ablation had larger peak deflection index (PDI), longer V2 R wave duration (V2 Rd), smaller V2 S wave amplitude, higher R/S ratio in V2 , higher V3 R wave amplitude, and larger V2 transition ratio than those with successful ablation. Multivariate analysis demonstrated that PDI, V2 Rd, V2 transition ratio, and pacemapping score acquired during mapping independently predicted failed ablation (P  =  0.01, P  =  0.01, P  =  0.01, and P < 0.001, respectively). In 31 recurrent cases (12.8%) after initially successful ablation, multivariate Cox regression analysis showed that only the earliest activation time acquired during mapping predicted the recurrences after successful ablation (P  =  0.001). The recurrent cases displayed different ECG features comparing with those with failed ablation. CONCLUSION: The electrocardiographic features of failed RVOT ablation of idiopathic OT-VAs with a transition ≥V3 were characterized by PDI, V2 Rd, V2 transition ratio, and pacemapping score acquired during mapping, unlike the recurrent RVOT ablation.


Assuntos
Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/cirurgia , Ablação por Cateter/efeitos adversos , Eletrocardiografia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia , Potenciais de Ação , Adulto , Bloqueio de Ramo/fisiopatologia , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Recidiva , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo , Falha de Tratamento , Complexos Ventriculares Prematuros/fisiopatologia
10.
Europace ; 20(3): 501-511, 2018 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-28082418

RESUMO

Aims: Whether the distribution of scar in arrhythmogenic right ventricular cardiomyopathy (ARVC) plays a role in predicting different types of ventricular arrhythmias is unknown. This study aimed to investigate the prognostic value of scar distribution in patients with ARVC. Methods and results: We studied 80 consecutive ARVC patients (46 men, mean age 47 ± 15 years) who underwent an electrophysiological study with ablation. Thirty-four patients receive both endocardial and epicardial mapping. Abnormal endocardial substrates and epicardial substrates were characterized. Three groups were defined according to the epicardial and endocardial scar gradient (<10%: transmural, 10-20%: intermediate, >20%: horizontal, as groups 1, 2, and 3, respectively). Sinus rhythm electrograms underwent a Hilbert-Huang spectral analysis and were displayed as 3D Simultaneous Amplitude Frequency Electrogram Transformation (SAFE-T) maps, which represented the arrhythmogenic potentials. The baseline characteristics were similar between the three groups. Group 3 patients had a higher incidence of fatal ventricular arrhythmias requiring defibrillation and cardiac arrest during the initial presentation despite having fewer premature ventricular complexes. A larger area of arrhythmogenic potentials in the epicardium was observed in patients with horizontal scar. The epicardial-endocardial scar gradient was independently associated with the occurrence of fatal ventricular arrhythmias after a multivariate adjustment. The total, ventricular tachycardia, and VF recurrent rates were higher in Group 3 during 38 ± 21 months of follow-up. Conclusion: For ARVC, the epicardial substrate that extended in the horizontal plane rather than transmurally provided the arrhythmogenic substrate for a fatal ventricular arrhythmia circuit.


Assuntos
Displasia Arritmogênica Ventricular Direita/complicações , Endocárdio/fisiopatologia , Pericárdio/fisiopatologia , Fibrilação Ventricular/etiologia , Potenciais de Ação , Adulto , Displasia Arritmogênica Ventricular Direita/diagnóstico por imagem , Displasia Arritmogênica Ventricular Direita/fisiopatologia , Ablação por Cateter , Morte Súbita Cardíaca/etiologia , Eletrocardiografia Ambulatorial , Técnicas Eletrofisiológicas Cardíacas , Endocárdio/diagnóstico por imagem , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Pericárdio/diagnóstico por imagem , Recidiva , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/fisiopatologia , Fibrilação Ventricular/cirurgia
11.
Int J Cardiol ; 241: 205-211, 2017 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-28456483

RESUMO

BACKGROUND: There are limited literatures regarding the non-pulmonary vein (NPV) triggers in long-standing persistent atrial fibrillation (LSPAF). The goal of the present study was to investigate the characteristics and long-term outcome of catheter ablation among these patients. METHODS: The study included 776 patients (age 53.59±11.38years-old, 556 males) who received catheter ablation for drug-refractory atrial fibrillation (AF). We divided these patients into 3 groups. Group 1 consisted of 579 patients with paroxysmal AF (PAF), group 2 consisted of 103 patients with persistent AF (PerAF) and group 3 consisted of 94 patients with long-standing persistent AF (LSPAF). The average follow-up duration was 28.53±23.21months. RESULTS: The clinical endpoint was the recurrence of atrial tachyarrhythmia. Among these 3 groups, higher percentages of male (93.6%, P<0.001), NPV triggers (44.7%, P<0.001), longer AF duration (6.65±6.72years, P=0.029), larger left atrium diameter (44.44±6.79mm, P<0.001), and longer procedure time (181.94±70.02min, P<0.001) were noted in LSPAF. After the first catheter ablation, the recurrence rate of AF was highest in LSPAF (Log Rank, P<0.001). Larger left atrium diameters (LAD) (P=0.006; HR: 1.063; CI: 1.018-1.111) and NPV triggers (P=0.035; HR: 1.707; 1.037-2.809) independently predicted AF recurrence in LSPAF. CONCLUSIONS: Compared with PAF and PerAF, LSPAF had a higher incidence of NPV triggers and worse long-term outcome after catheter ablation. NPV triggers and LAD independently predicted AF recurrence after catheter ablation in LSPAF.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/tendências , Veias Pulmonares/cirurgia , Adulto , Idoso , Fibrilação Atrial/fisiopatologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Resultado do Tratamento
12.
Pacing Clin Electrophysiol ; 40(7): 754-761, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28436566

RESUMO

BACKGROUNDS: Substrate property is related to the genesis and maintenance of atrial fibrillation (AF). The aim of the study was to investigate the impact of substrate property on the electrocardiogram (ECG) in patients with AF originating from the superior vena cava (SVC). METHODS AND RESULTS: Seventy-six patients with AF originating from SVC who underwent catheter ablation were included from 2004 to 2013. Of these patients, 16 had a presentation of atrial flutter (AFL)-pattern ECG during AF (group 1), and 60 patients did not (group 2). There was no significant difference in clinical characteristics between the groups. The percentage of low voltage zone (LVZ) in SVC below the level of pulmonary artery in group 1 was significantly larger than that in group 2. The polarities of the flutter wave in 12-lead ECG were compared with another 26 subjects with reverse typical AFL. The ECG morphology was characterized by negative or biphasic P waves in lead V1 in most of the patients in group 1 (62.5%), which was analogous to that in reverse typical AFL. The negative polarity of flutter waves in aVL might distinguish SVC AF with an AFL-pattern from reverse typical AFL. CONCLUSION: The ECG characteristics of AF originating from SVC can mimic atypical AFL. LVZ in the SVC may be associated with the presentation of AFL-pattern ECG.


Assuntos
Fibrilação Atrial/fisiopatologia , Flutter Atrial/fisiopatologia , Eletrocardiografia , Veia Cava Superior/fisiopatologia , Fibrilação Atrial/cirurgia , Flutter Atrial/cirurgia , Ablação por Cateter , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Artéria Pulmonar/fisiopatologia , Ondas de Rádio
13.
Medicine (Baltimore) ; 96(15): e6516, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28403080

RESUMO

Diurnal variations in ventricular tachyarrhythmias (VAs) have been demonstrated in idiopathic arrhythmogenic heart disease. The electrophysiological characteristics of diurnal variations in idiopathic right ventricular outflow tract (RVOT) VA have not previously been elucidated. Sixty-two consecutive patients undergoing catheter ablation for idiopathic RVOT VA (mean age: 42.8 ±â€Š12.3 years, 35 females) were enrolled. The diurnal variation type (group 1, n = 36) was defined as those patients who had most ventricular premature contractions (VPCs) during the night hours by preprocedure Holter recordings. Group 2 (n = 26) was defined as those patients who did not have significant VPC variations. The baseline characteristics and electrophysiological properties were collected and analyzed, and the rates of recurrence after catheter ablation were compared between the 2 groups. In this study, heart rate variability analysis demonstrated lower low frequency/high frequency ratios in group 1 than in group 2 (3.95 ±â€Š3.08 vs 6.26 ±â€Š5.33; P = 0.042). There were no significant differences in baseline characteristics, echocardiography and electrophysiological characteristics between the 2 groups. During a mean follow-up period of 13.5 ±â€Š11.0 months, a total of 16 patients had VA recurrences, including 13 patients from group 1 and 3 patients from group 2 (36.1% vs 12.5%, P = 0.039). This study demonstrated the effect of the autonomic nervous system in idiopathic RVOT VAs and that the diurnal variation type leads to a higher recurrence rate after catheter ablation.


Assuntos
Ablação por Cateter , Taquicardia Ventricular/fisiopatologia , Função Ventricular Direita , Complexos Ventriculares Prematuros/fisiopatologia , Adulto , Sistema Nervoso Autônomo/fisiopatologia , Ritmo Circadiano , Ecocardiografia , Eletrocardiografia , Feminino , Seguimentos , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Recidiva , Taquicardia Ventricular/cirurgia , Resultado do Tratamento , Complexos Ventriculares Prematuros/cirurgia
14.
PLoS One ; 12(3): e0173189, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28282453

RESUMO

INTRODUCTION: The signal characteristics of intracardiac bipolar electrograms at the origin of idiopathic RVOT-VT during sinus rhythm remain unclear. OBJECTIVE: The study sought to develop a novel real-time/online technique, simultaneous amplitude frequency electrogram transformation (SAFE-T), to quantify and localize the diseased ventricular substrate in idiopathic RVOT-VT. METHODS: We retrospectively investigated the intracardiac bipolar recordings in 70 consecutive patients (26% male, mean age 42±12 years) who underwent successful radiofrequency catheter ablation of idiopathic RVOT-VT. We quantified the extent of the frequency fraction of ventricular potentials during sinus rhythm or ventricular pacing using a novel formula, the product of instantaneous amplitude and frequency, and showed that in a 3D geometry as an online SAFE-T map. RESULTS: The characteristics of the HHT spectra of electrograms derived from VT origins demonstrated high frequency components (>70 Hz), which were independent of the rhythm. The density of the abnormal potentials at the VT origins were higher (VT origins, 7.5±2.3 sites/cm2 vs. surrounding myocardium, 1.5±1.3 sites/cm2, p<0.001), and were significantly decreased after ablation (0.7±0.6 sites/cm2, p<0.001). A small region of abnormal potentials were observed in the VT origins (mean area of 1.5±0.8 cm2). The SAFE-T maps predicted the VT origins with 92% sensitivity, 78% specificity with optimal cut-off value of >3.0 Hz·mV. CONCLUSION: The online SAFE-T map was feasible for quantifying the diseased ventricular substrate, irrespective of the rhythm of activation, and can be used to identify the optimal ablation targets for idiopathic RVOT-VT. We found a limited region of abnormal potentials where the RVOT-VT origins were successfully ablated.


Assuntos
Ventrículos do Coração/fisiopatologia , Taquicardia Ventricular/fisiopatologia , Adulto , Área Sob a Curva , Ablação por Cateter , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Curva ROC , Estudos Retrospectivos , Processamento de Sinais Assistido por Computador , Taquicardia Ventricular/metabolismo , Taquicardia Ventricular/terapia
15.
Medicine (Baltimore) ; 96(1): e5476, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28072689

RESUMO

The long-term clinical impact of premature ventricular complexes (PVCs) on mortality and morbidity has not been fully studied. This study aimed to investigate the association between the burden of PVCs and adverse clinical outcome.A total of 5778 subjects, who were pacemaker-free and ventricular tachycardia-free at baseline, received 24-hour electrocardiography monitoring between January 1, 2002 and December 31, 2004. Clinical event data were retrieved from the Bureau of National Health Insurance of Taiwan. Multivariate Cox hazards regression models and propensity-score matching were applied to assess the association between PVCs and adverse clinical outcome.Average follow-up time was 10[REPLACEMENT CHARACTER]±â€Š1 year. In all, 1403 subjects expired, 1301 subjects were hospitalized in the cardiovascular (CV) ward, 3384 were hospitalized for any reason, and 631 subjects developed new-onset heart failure (HF). The optimal cut-off PVC frequency (12 beats per day) was obtained through receiver operator characteristic curves, with a sensitivity of 58.4% and specificity of 59.8%. Upon multivariate analysis, a PVC frequency >12 beats per day was an independent predictor for all mortality (hazard ratio [HR]: 1.429, 95% confidence interval [CI]: 1.284-1.590), CV hospitalization (HR: 1.127, 95% CI: 1.008-1.260), all-cause hospitalization (HR 1.094, 95% CI: 1.021-1.173), and new-onset HF (HR: 1.411, 95% CI: 1.203-1.655). Subjects with a PVC frequency >12 beats per day had an increased risk of cardiac death attributable to HF and sudden cardiac death. The incidence rates for mortality and HF were significantly increased in cases of raised PVC frequency. Propensity-score matching analysis also echoed the main findings.Increased PVC burden was associated with a higher incidence of all-cause mortality, CV hospitalization, all-cause hospitalization, and new-onset HF which was independent of other clinical risk factors.


Assuntos
Efeitos Psicossociais da Doença , Insuficiência Cardíaca , Hospitalização/estatística & dados numéricos , Complexos Ventriculares Prematuros , Adulto , Idoso , Eletrocardiografia Ambulatorial/métodos , Feminino , Seguimentos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/epidemiologia , Humanos , Estimativa de Kaplan-Meier , Efeitos Adversos de Longa Duração/diagnóstico , Efeitos Adversos de Longa Duração/epidemiologia , Efeitos Adversos de Longa Duração/etiologia , Masculino , Pessoa de Meia-Idade , Curva ROC , Fatores de Risco , Taiwan/epidemiologia , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/mortalidade , Complexos Ventriculares Prematuros/terapia
16.
J Cardiovasc Electrophysiol ; 28(1): 23-30, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27779351

RESUMO

INTRODUCTION: Although rare, some paroxysmal atrial fibrillations (AF) still progress despite radiofrequency (RF) ablation. In the study, we evaluated the long-term efficacy of RF ablation and the predictors of AF progression. METHODS: A total of 589 paroxysmal AF patients (404 men and 185 women; aged 54 ± 12 years) who received 3-dimensional mapping and ablation were enrolled. Their clinical parameters and electrophysiological characteristics were collected. They were divided into Group 1 (N = 13, with AF progression) and Group 2 (N = 576, no AF progression). AF progression was defined as recurrence of persistent AF. RESULTS: Group 1 patients had larger left atrial (LA) diameter, larger left ventricle (LV) end-systolic and end-diastolic diameters, poorer LV systolic function, and more amiodarone use at baseline. After 1.2 ± 0.5 procedures, 123 (21%) patients experienced recurrence during 56 ± 29 months' follow-up. In the multivariate analysis, LA diameter (P = 0.018, HR = 1.12, 95% CI = 1.02-1.24) and LV end-systolic diameter (P = 0.005, HR = 1.10, 95% CI = 1.03-1.17) independently predicted AF progression. LA diameter >43 mm and LV end-systolic diameter >31 mm were the best cut-off values for predicting AF progression by ROC analysis. AF progression rate achieved 19% if they had both larger LA diameter (>43 mm) and LV end-systolic diameter (>31 mm). CONCLUSION: RF ablation prevents the progression of paroxysmal AF effectively, except in patients with increased LA diameter and LV end-systolic diameter on echocardiogram, suggesting more aggressive rhythm control therapies should be considered in these patients.


Assuntos
Fibrilação Atrial/cirurgia , Função do Átrio Esquerdo , Ablação por Cateter/efeitos adversos , Átrios do Coração/cirurgia , Ventrículos do Coração/fisiopatologia , Volume Sistólico , Função Ventricular Esquerda , Adulto , Idoso , Área Sob a Curva , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Distribuição de Qui-Quadrado , Progressão da Doença , Ecocardiografia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Valor Preditivo dos Testes , Modelos de Riscos Proporcionais , Curva ROC , Recidiva , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
17.
Int J Cardiol ; 227: 650-655, 2017 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-27838125

RESUMO

BACKGROUND: Aortic dilatation was frequently observed in patients with atrial fibrillation (AF) and non-pulmonary vein (PV) triggers are important for mapping and ablation of AF. We hypothesized that the aortic encroachment area over left atrium (LA) could contribute to the local substrate characteristics. METHODS: We studied 32 consecutive patients of AF (age=57.34±8.07, male=30), including 26 paroxysmal and 6 persistent AFs. Anatomic relationship between LA and aorta, and electrophysiological characteristics of the encroachment areas were investigated. IRB approval was taken. RESULTS: The LA bipolar voltage (mean 0.49±0.26mV) was lower at aortic encroached area compared to global LA (mean 1.52±0.48mV) and it was statistically significant (p<0.001). There was a linear correlation between the voltages of LA and distance from the aorta to the aortic encroachment area of LA (p<0.001, R=0.616). Non-PV triggers were observed in 34.37% (n=11) of total patients. The initiation of AF in aortic encroached area was seen in 45.45% (n=5) of non-PV trigger and 15.62% of total patients. All the patients were followed up for 6months and 4 (14.81%) out of 27 patients without trigger at aortic encroached site of LA and 1 (20%) out of 5 patients with trigger at aortic encroached site of LA had recurrence of AF. CONCLUSION: The aorta contributed to low voltages on its encroachment area over the anterior wall of LA. Non-pulmonary vein triggers originating from the aortic encroachment area were found in 15.62% of total patients. Careful evaluation of the anatomical relationship between LA and aorta is important during AF ablation for a better long term outcome.


Assuntos
Aorta/diagnóstico por imagem , Fibrilação Atrial/diagnóstico por imagem , Átrios do Coração/diagnóstico por imagem , Veias Pulmonares , Idoso , Aorta/fisiopatologia , Fibrilação Atrial/etiologia , Fibrilação Atrial/fisiopatologia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Seguimentos , Átrios do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X
18.
PLoS One ; 11(8): e0160181, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27548469

RESUMO

BACKGROUND: The impact of non-sustained ventricular tachycardia (NSVT) on the risk of thromboembolic event and clinical outcomes in patients without structural heart disease remains undetermined. This study aimed to evaluate the association between NSVT and clinical outcomes. METHODS: The study population of 5903 patients was culled from the "Registry of 24-hour ECG monitoring at Taipei Veterans General Hospital" (REMOTE database) between January 1, 2002 and December 31, 2004. Of that total, we enrolled 3767 patients without sustained ventricular tachycardia, structural heart disease, and permanent pacemaker. For purposes of this study, NSVT was defined as 3 or more consecutive beats arising below the atrioventricular node with an RR interval of <600 ms (>100 beats/min) and lasting < 30 seconds. RESULT: There were 776 deaths, 2042 hospitalizations for any reason, 638 cardiovascular (CV)-related hospitalizations, 350 ischemic strokes, 409 transient ischemic accident (TIA), 368 new-onset heart failure (HF), and 260 new-onset atrial fibrillation (AF) with a mean follow-up duration of 10 ± 1 years. In multivariate analysis, the presence of NSVT was independently associated with death (hazard ratio [HR]: 1.362, 95% confidence interval [CI]: 1.071-1.731), CV hospitalization (HR: 1.527, 95% CI: 1.171-1.992), ischemic stroke (HR: 1.436, 95% CI: 1.014-2.032), TIA (HR 1.483, 95% CI: 1.069-2.057), and new-onset HF (HR: 1.716, 95% CI: 1.243-2.368). There was no significant association between the presence of NSVT and all-cause hospitalization or new-onset AF. CONCLUSION: In patients without structural heart disease, presence of NSVT on 24-hour monitoring was independently associated with death, CV hospitalization, ischemic stroke, TIA, and new onset heart failure.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Insuficiência Cardíaca/diagnóstico por imagem , Isquemia Miocárdica/diagnóstico por imagem , Sistema de Registros , Acidente Vascular Cerebral/diagnóstico por imagem , Taquicardia Ventricular/diagnóstico por imagem , Tromboembolia/diagnóstico por imagem , Idoso , Fibrilação Atrial/etiologia , Fibrilação Atrial/mortalidade , Fibrilação Atrial/fisiopatologia , Eletrocardiografia , Feminino , Seguimentos , Coração , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Hospitalização , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Isquemia Miocárdica/etiologia , Isquemia Miocárdica/mortalidade , Isquemia Miocárdica/fisiopatologia , Marca-Passo Artificial , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/mortalidade , Acidente Vascular Cerebral/fisiopatologia , Taquicardia Ventricular/complicações , Taquicardia Ventricular/mortalidade , Taquicardia Ventricular/fisiopatologia , Taiwan , Tromboembolia/etiologia , Tromboembolia/mortalidade , Tromboembolia/fisiopatologia
19.
Heart Rhythm ; 13(7): 1431-40, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27324561

RESUMO

BACKGROUND: Ventricular arrhythmia originating from the papillary muscle (VA-PM) is characterized by multiple exits and morphologic alternations. The conventional ablation strategy relies on activation mapping, but the results might be suboptimal. OBJECTIVE: The purpose of this study was to propose a novel pacemapping strategy aimed at multiple exits using high-output software as a complementary approach to the conventional strategy. METHODS: A consecutive 13 patients with VA-PM were enrolled in this study. Novel pacemapping based on an automatic matching algorithm and integrated electroanatomic mapping was used to quantify the morphology variation in these patients and to identify the potential exits of VA-PM. Complementary ablation targeting at the best matching site of each morphology was performed. RESULTS: Twelve of 13 patients (92%) experienced morphologic alternation, and a total of 34 morphologies were detected (2.6 ± 1.0 per patient). A total of 23 (68%) morphologies were detected as spontaneous pleomorphic ventricular premature complexes (VPCs) before procedure, and 4 morphologies (12%) were induced under isoproterenol infusion. Another 7 of 34 morphologies (21%) could be found only after radiofrequency ablation attempts. Exits with a high pacemapping correlation index for corresponding morphology would be mapped, so preferential exits could be identified. Mean interexit distance was 15.1 ± 5.9 mm. Acute success rate was 100%. During mean follow-up of 12.2 ± 6.9 months, only 1 case recurred with ventricular tachycardia. Although 3 cases recurred with different VPC morphologies, the VPC burden decreased from 16.3% ± 8.8% to 2.6% ± 1.7%. CONCLUSION: This novel pacemapping strategy could effectively eliminate multiple exits as a complementary approach to the conventional strategy.


Assuntos
Mapeamento Potencial de Superfície Corporal , Ablação por Cateter/métodos , Ecocardiografia Tridimensional/métodos , Taquicardia Ventricular , Adulto , Mapeamento Potencial de Superfície Corporal/instrumentação , Mapeamento Potencial de Superfície Corporal/métodos , Processamento Eletrônico de Dados/métodos , Feminino , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Músculos Papilares/fisiopatologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/prevenção & controle
20.
Europace ; 18(8): 1259-64, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26612879

RESUMO

AIMS: The detailed electrophysiological characteristics of patients with both atrioventricular nodal re-entrant tachycardia (AVNRT) and atrial flutter (AFL) have not been clarified. This study investigated the related electrophysiological differences in a large series of patients undergoing radiofrequency catheter ablation of AVNRT. METHODS AND RESULTS: A total of 1063 clinically documented AVNRT patients underwent catheter ablation were enrolled. Before the slow pathway (SP) ablation, 61 patients (5.7%) had inducible sustained cavotricuspid isthmus (CTI)-dependent AFL (Group 1), and the others (94.3%) without inducible sustained CTI-dependent AFL were defined as Group 2. The electrophysiological characteristics of these two groups and effect of the SP ablation on the inducibility of AFL were assessed. In Group 1, 36 patients (59%) had inducible/sustained AFL after the ablation of AVNRT and required a CTI ablation. The Group 1 patients had more AVNRT with continuous atrioventricular (AV) node function curves (P < 0.001, odds ratio = 7.55 [3.70-16.7], multivariate regression), and a younger age (P = 0.02, odds ratio = 1.02 [1.003-1.03], multivariate regression) than Group 2. The other characteristics were comparable between the two groups. The long-term follow-up (64.9 ± 34.9 months) revealed that the recurrence of AFL/atrial fibrillation was similar between the two groups (P > 0.05). CONCLUSION: Atrioventricular nodal re-entrant tachycardia patients with concomitant CTI-dependent AFL had more continuous AV node function curves. Forty-one per cent of these patients had non-inducible AFL after the SP ablation, indicating a slow conduction isthmus in the triangle of Koch area.


Assuntos
Flutter Atrial/cirurgia , Nó Atrioventricular/fisiopatologia , Ablação por Cateter , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Valva Tricúspide/fisiopatologia , Adulto , Idoso , Eletrocardiografia , Fenômenos Eletrofisiológicos , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Recidiva , Análise de Regressão
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA