Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 56
Filtrar
1.
Otolaryngol Head Neck Surg ; 171(4): 1133-1139, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38686601

RESUMO

OBJECTIVE: To investigate the impact of sound exposure, with the resultant windows vibration on perilymphatic concentrations following intratympanic (IT) dexamethasone and gentamicin in an animal model. STUDY DESIGN: Animal model blinded study. SETTING: Animal facility of a tertiary medical center. METHODS: Bilateral IT dexamethasone or gentamicin was applied to 15 tested rats. Following injections, each rat was exposed for 3 minutes to free field 30 dB sound pressure level (SPL), 512 vHz noise, with 1 external auditory canal plugged (contralateral control). Following noise exposure, perilymph was obtained from both ears. Drug concentrations were measured using ultrahigh-performance liquid chromatography-mass spectrometer. RESULTS: For dexamethasone, the average (±SD) perilymphatic steroidal concentration was 0.417 µg/mL (±0.549) in the control ears versus 0.487 µg/mL (±0.636) in the sound-exposed ears (P = .008). The average (±SD) gentamicin perilymphatic concentration was 8.628 µg/mL (±2.549) in the sound-exposed ears, compared to 4.930 µg/mL (±0.668) in the contralateral control (nonsound exposed) ears. Sound exposure promoted steroidal and gentamicin diffusion to the inner ear by an averaged (±SD) factor of 1.431 and 1.730 (±0.291 and 0.339), respectively. CONCLUSION: Low-intensity noise (30 dB SPL) was found to enhance dexamethasone phosphate and gentamicin diffusion to the inner ear (by an averaged factor of ∼1.4 and 1.7, respectively) in a murine model.


Assuntos
Dexametasona , Gentamicinas , Injeção Intratimpânica , Animais , Gentamicinas/administração & dosagem , Gentamicinas/farmacocinética , Dexametasona/administração & dosagem , Dexametasona/farmacocinética , Ratos , Perilinfa , Ratos Sprague-Dawley , Orelha Interna/efeitos dos fármacos , Ruído , Antibacterianos/administração & dosagem , Antibacterianos/farmacocinética , Masculino , Glucocorticoides/administração & dosagem , Glucocorticoides/farmacocinética
2.
Front Surg ; 11: 1271248, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38444902

RESUMO

Objective: To report a novel technique in Balloon Dilation of Eustachian Tube (BDET) using an endovascular balloon (EVB), in a prospective cohort. The results are compared with reported outcomes using standard balloons. Methods: Demographic information and clinical parameters were collected prospectively fora series of patients with obstructive eustachian tube dysfunction (OETD). Balloon dilation Eustachian tuboplasty was performed under local anesthesia in a tertiary referral center, using the EVB. Systematic literature review was used for comparison, using Medline via "PubMed", "Embase", and "Web of Science". Results: Eight OETD candidates (12 ears) were enrolled; 5 males and 3 females. Average age was 48 (range -23 to 63) years. The most common presenting symptom was aural fullness (9/12), followed by ear pressure (7/12), hearing loss (5/12) and tinnitus (4/12). Otoscopically, tympanic membrane retraction was evident in 10/12 ears, the majority of which was class II-Sade classification. Pre-operative tympanogram was type B and C in 7 and 5 ears, respectively. All BDETs were performed without complications. Post-operative tympanometry was A in 8/12 ears. Post-operatively, Eustachian Tube Dysfunction Questionnaire-7 results reduced to within normal limits (average score ≤3) in 11/12 ears (p = 0.0014). The systematic literature review included 6 papers (193 patients, 262 ETs) with comparable results, most also with little adverse effects. Conclusion: BDET using an EVB is a safe and effective option for OETD. It is well tolerated under local anesthesia in properly selected individuals. The reduced procedural cost may be an important factor in certain healthcare jurisdictions.

3.
Oper Neurosurg (Hagerstown) ; 26(1): 78-85, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37747333

RESUMO

BACKGROUND AND OBJECTIVES: Virtual reality (VR) surgical rehearsal is an educational tool that exists in a safe environment. Validation is necessary to establish the educational value of this platform. The middle cranial fossa (MCF) is ideal for simulation because trainees have limited exposure to this approach and it has considerable complication risk. Our objectives were to assess the face, content, and construct validities of an MCF VR simulation, as well as the change in performance across serial simulations. METHODS: Using high-resolution volumetric data sets of human cadavers, the authors generated a high-fidelity visual and haptic rendering of the MCF approach using CardinalSim software. Trainees from Neurosurgery and Otolaryngology-Head and Neck Surgery at two Canadian academic centers performed MCF dissections on this VR platform. Randomization was used to assess the effect of enhanced VR interaction. Likert scales were used to assess the face and content validities. Performance metrics and pre- and postsimulation test scores were evaluated. Construct validity was evaluated by examining the effect of the training level on simulation performance. RESULTS: Twenty trainees were enrolled. Face and content validities were achieved in all domains. Construct validity, however, was not demonstrated. Postsimulation test scores were significantly higher than presimulation test scores ( P < .001 ). Trainees demonstrated statistically significant improvement in the time to complete dissections ( P < .001 ), internal auditory canal skeletonization ( P < .001 ), completeness of the anterior petrosectomy ( P < .001 ), and reduced number of injuries to critical structures ( P = .001 ). CONCLUSION: This MCF VR simulation created using CardinalSim demonstrated face and content validities. Construct validity was not established because no trainee included in the study had previous MCF approach experience, which further emphasizes the importance of simulation. When used as a formative educational adjunct in both Neurosurgery and Otolaryngology-Head and Neck Surgery, this simulation has the potential to enhance understanding of the complex anatomic relationships of critical neurovascular structures.


Assuntos
Neurocirurgia , Realidade Virtual , Humanos , Fossa Craniana Média/cirurgia , Canadá , Simulação por Computador , Neurocirurgia/educação
4.
J Otolaryngol Head Neck Surg ; 52(1): 73, 2023 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-37941039

RESUMO

BACKGROUND: Within otologic surgery, a paucity of well-controlled studies assessing the use of systemic antibiotic to reduce surgical site infections exists. Moreover, discrepancies in wound classification of procedures challenge consensus in antimicrobial prescribing patterns. We sought to compare surgeons from two different health systems to examine how surgeons' prescribing habits compared to practice guidelines for numerous otologic procedures. METHODS: An online questionnaire was distributed to 33 Canadian and 32 Austrian surgeons who regularly perform otologic surgery. Current systemic antibiotic prescribing habits for cochlear implantation, cholesteatoma surgery, stapes surgery, and tympanoplasty ± ossiculoplasty were collected. RESULTS: Eighteen of 33 (54.5%) Canadian surgeons provided responses, while 18 of 32 (56.3%) of Austrian surgeons answered. Clear consistency with clinical practice guidelines exists for pre-operative antibiotics use in cochlear implant surgery and infected cholesteatoma surgery. However, for stapes surgery and tympanoplasty ± ossiculoplasty, consensus is lacking for both pre- and post-operative antibiotic prescribing habits. Notable differences between the two countries include post-operative antibiotics for cochlear implant surgery (Austria: 36.4%, Canada: 71.4%) and uninfected cholesteatoma surgery (Austria: 33.3%, Canada: 77.8%). Across all procedures, both induction and post-operative antibiotic administration was not significantly associated with surgeon seniority when stratified by five-year increments. CONCLUSION: The lack of consensus among each country's otologic surgeons underscores the uncertainty in wound classification and thus, adherence to clinical practice guidelines.


Assuntos
Colesteatoma , Procedimentos Cirúrgicos Otológicos , Humanos , Antibacterianos/uso terapêutico , Canadá , Timpanoplastia
5.
Sci Rep ; 13(1): 7182, 2023 05 03.
Artigo em Inglês | MEDLINE | ID: mdl-37137995

RESUMO

Exact placement of bone conduction implants requires avoidance of critical structures. Existing guidance technologies for intraoperative placement have lacked widespread adoption given accessibility challenges and significant cognitive loading. The purpose of this study is to examine the application of augmented reality (AR) guided surgery on accuracy, duration, and ease on bone conduction implantation. Five surgeons surgically implanted two different types of conduction implants on cadaveric specimens with and without AR projection. Pre- and postoperative computer tomography scans were superimposed to calculate centre-to-centre distances and angular accuracies. Wilcoxon signed-rank testing was used to compare centre-to-centre (C-C) and angular accuracies between the control and experimental arms. Additionally, projection accuracy was derived from the distance between the bony fiducials and the projected fiducials using image guidance coordinates. Both operative time (4.3 ± 1.2 min. vs. 6.6 ± 3.5 min., p = 0.030) and centre-to-centre distances surgery (1.9 ± 1.6 mm vs. 9.0 ± 5.3 mm, p < 0.001) were significantly less in augmented reality guided surgery. The difference in angular accuracy, however, was not significantly different. The overall average distance between the bony fiducial markings and the AR projected fiducials was 1.7 ± 0.6 mm. With direct intraoperative reference, AR-guided surgery enhances bone conduction implant placement while reduces operative time when compared to conventional surgical planning.


Assuntos
Realidade Aumentada , Cirurgia Assistida por Computador , Humanos , Cirurgia Assistida por Computador/métodos , Condução Óssea , Imageamento Tridimensional/métodos , Marcadores Fiduciais
6.
Otol Neurotol ; 44(5): e287-e294, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-36962009

RESUMO

OBJECTIVE: To (i) demonstrate the utility of geographically weighted Poisson regression (GWPR) in describing geographical patterns of adult cochlear implant (CI) incidence in relation to sociodemographic factors in a publicly funded healthcare system, and (ii) compare Poisson regression and GWPR to fit the aforementioned relationship. STUDY DESIGN: Retrospective study of provincial CI Program database. SETTING: Academic hospital. PATIENTS: Adults 18 years or older who received a CI from 2020 to 2021. INTERVENTIONS: Cochlear implant. MAIN OUTCOME MEASURES: CI incidence based on income level, education attainment, age at implantation, and distance from center, and spatial autocorrelation across census metropolitan areas. RESULTS: Adult CI incidence varied spatially across Ontario (Moran's I = 0.04, p < 0.05). Poisson regression demonstrated positive associations between implantation and lower income level (coefficient = 0.0284, p < 0.05) and younger age (coefficient = 0.1075, p < 0.01), and a negative association with distance to CI center (coefficient = -0.0060, p < 0.01). Spatial autocorrelation was significant in Poisson model (Moran's I = 0.13, p < 0.05). GWPR accounted for spatial differences (Moran's I = 0.24, p < 0.690), and similar associations to Poisson were observed. GWPR further identified clusters of implantation in South Central census metropolitan areas with higher education attainment. CONCLUSIONS: Adult CI incidence demonstrated a nonstationary relationship between implantation and the studied sociodemographic factors. GWPR performed better than Poisson regression in accounting for these local spatial variations. These results support the development of targeted interventions to improve access and utilization to CIs in a publicly funded healthcare system.


Assuntos
Implante Coclear , Implantes Cocleares , Humanos , Adulto , Estudos Retrospectivos , Fatores Sociodemográficos , Regressão Espacial
7.
J Otolaryngol Head Neck Surg ; 52(1): 20, 2023 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-36855202

RESUMO

BACKGROUND: Obstructive eustachian tube dysfunction is a common pathology, generally accepted as the underlying cause for chronic ear diseases. Eustachian tube dilation has shown promising results in randomized controlled trials, but is a costly procedure. The aim of the current study was to assess the feasibility of transnasal balloon dilatation of the eustachian tube with an endovascular balloon in the context of ease of use, maneuverability, and safety. METHODS: Clinical pilot study carried out at a university tertiary care facility. In total, twelve patients, were included over a period of 6 months. All patients underwent tympanoplasty or tympanomastoidectomy surgeries. Eustachian tube dilation was carried out transnasal using an endovascular balloon. A computed tomography was carried out after surgery to assess for any potential damages and compared to preoperative imaging studies. Postoperative endoscopy was performed intraoperatively and at follow up to assess for any potential damages. RESULTS: All eustachian tube dilations were carried out successfully. No severe adverse events were noted during the procedure, in the postoperative period, or on imaging studies. Minor adverse events such as mild intraoperative bleeding was managed in a routine fashion. CONCLUSIONS: Balloon dilation of the eustachian tube with the endovascular balloon was feasible and safe in all cases. It is likely a more cost-effective alternative to commercially available balloons with similar designs and specifications. Trial registration The study was registered at clinicaltrials.gov; NCT04809753, initial release February 24th, 2021.


Assuntos
Tuba Auditiva , Humanos , Dilatação , Tuba Auditiva/diagnóstico por imagem , Tuba Auditiva/cirurgia , Estudos de Viabilidade , Projetos Piloto , Ventilação da Orelha Média
8.
Front Hum Neurosci ; 16: 1043499, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36419642

RESUMO

There is a weak relationship between clinical and self-reported speech perception outcomes in cochlear implant (CI) listeners. Such poor correspondence may be due to differences in clinical and "real-world" listening environments and stimuli. Speech in the real world is often accompanied by visual cues, background environmental noise, and is generally in a conversational context, all factors that could affect listening demand. Thus, our objectives were to determine if brain responses to naturalistic speech could index speech perception and listening demand in CI users. Accordingly, we recorded high-density electroencephalogram (EEG) while CI users listened/watched a naturalistic stimulus (i.e., the television show, "The Office"). We used continuous EEG to quantify "speech neural tracking" (i.e., TRFs, temporal response functions) to the show's soundtrack and 8-12 Hz (alpha) brain rhythms commonly related to listening effort. Background noise at three different signal-to-noise ratios (SNRs), +5, +10, and +15 dB were presented to vary the difficulty of following the television show, mimicking a natural noisy environment. The task also included an audio-only (no video) condition. After each condition, participants subjectively rated listening demand and the degree of words and conversations they felt they understood. Fifteen CI users reported progressively higher degrees of listening demand and less words and conversation with increasing background noise. Listening demand and conversation understanding in the audio-only condition was comparable to that of the highest noise condition (+5 dB). Increasing background noise affected speech neural tracking at a group level, in addition to eliciting strong individual differences. Mixed effect modeling showed that listening demand and conversation understanding were correlated to early cortical speech tracking, such that high demand and low conversation understanding occurred with lower amplitude TRFs. In the high noise condition, greater listening demand was negatively correlated to parietal alpha power, where higher demand was related to lower alpha power. No significant correlations were observed between TRF/alpha and clinical speech perception scores. These results are similar to previous findings showing little relationship between clinical speech perception and quality-of-life in CI users. However, physiological responses to complex natural speech may provide an objective measure of aspects of quality-of-life measures like self-perceived listening demand.

9.
Oper Neurosurg (Hagerstown) ; 23(6): 505-513, 2022 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-36227206

RESUMO

BACKGROUND: Virtual reality simulation has gained prominence as a valuable surgical rehearsal and education tool in neurosurgery. Approaches to the internal auditory canal, cerebellopontine angle, and ventral brainstem region using the middle cranial fossa are not well explored by simulation. OBJECTIVE: We hope to contribute to this paucity in simulation tools devoted to the lateral skull base, specifically the middle cranial fossa approach. METHODS: Eight high-resolution microcomputed tomography scans of human cadavers were used as volumetric data sets to construct a high-fidelity visual and haptic rendering of the middle cranial fossa using CardinalSim software. Critical neurovascular structures related to this region of the skull base were segmented and incorporated into the modules. RESULTS: The virtual models illustrate the 3-dimensional anatomic relationships of neurovascular structures in the middle cranial fossa and allow a realistic interactive drilling environment. This is facilitated by the ability to render bone opaque or transparent to reveal the proximity to critical anatomy allowing for practice of the virtual dissection in a graduated fashion. CONCLUSION: We have developed a virtual library of middle cranial fossa approach models, which integrate relevant neurovascular structures with aims to improve surgical training and education. A ready extension is the potential for patient-specific application and pathology.


Assuntos
Fossa Craniana Média , Realidade Virtual , Humanos , Fossa Craniana Média/cirurgia , Fossa Craniana Média/anatomia & histologia , Microtomografia por Raio-X , Osso Petroso/cirurgia , Simulação por Computador
10.
Curr Opin Otolaryngol Head Neck Surg ; 30(5): 321-325, 2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-36004790

RESUMO

PURPOSE OF REVIEW: The purpose of this review is to offer a concise summary of current knowledge regarding hidden hearing loss (HHL) and to describe the variety of mechanisms that contribute to its development. We will also discuss the various diagnostic tools that are available as well as future directions. RECENT FINDINGS: Hidden hearing loss often also called cochlear synaptopathy affects afferent synapses of the inner hair cells. This description is in contrast to traditional models of hearing loss, which predominantly affects auditory hair cells. In HHL, the synapses of nerve fibres with a slow spontaneous firing rate, which are crucial for locating sound in background noise, are severely impaired. In addition, recent research suggests that HHL may also be related to cochlear nerve demyelination. Noise exposure causes loss of myelin sheath thickness. Auditory brainstem response, envelope-following response and middle-ear muscle reflex are promising diagnostic tests, but they have yet to be validated in humans. SUMMARY: Establishing diagnostic tools for cochlear synaptopathy in humans is important to better understand this patient population, predict the long-term outcomes and allow patients to take the necessary protective precautions.


Assuntos
Surdez , Perda Auditiva Provocada por Ruído , Perda Auditiva , Limiar Auditivo , Cóclea , Potenciais Evocados Auditivos do Tronco Encefálico , Humanos , Ruído
11.
Laryngoscope ; 132(1): 204-211, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34495556

RESUMO

OBJECTIVES: The aim of this study was to prospectively assess pain and associated analgesic consumption after otological surgery comparing two prescription patterns. STUDY DESIGN: A prospective nonrandomized consecutive cohort study. METHODS: 125 adult patients undergoing ambulatory otologic surgery-cochlear implantation and endaural middle ear surgery, were assigned (according to surgeon's preference) and prospectively studied in two arms: 1) acetaminophen 500 mg + ibuprofen 400 mg; 2) acetaminophen 500 mg + codeine 30 mg. Pain levels, medication dose, disposal patterns of opioids, and suspected side effects were evaluated. RESULTS: All patients reported mild to moderate pain. There was a statistically significant reduction of pain from day to day, which was on average 0.26 lower than the day before. Sufficient pain control could be achieved with both drug regimens with no significant difference in pain levels. Only 50% of patients who were prescribed opioids used them. Additionally, the median tablet intake was 3 tablets while 10 to 20 tablets were prescribed. The majority of patients (97%) did not dispose of these drugs safely. CONCLUSION: Adequate analgesia was achieved in both arms of this study. Pain control following otologic surgery with a combination of acetaminophen and nonsteroidal anti-inflammatory drugs is recommended unless contraindications or chronic opioid use are present. If opioids such as codeine (30 mg) are prescribed, the amount should be reduced as low as possible, such as five tablets, based on our studied population. LEVEL OF EVIDENCE: 3 Laryngoscope, 132:204-211, 2022.


Assuntos
Analgésicos/uso terapêutico , Procedimentos Cirúrgicos Otológicos/efeitos adversos , Manejo da Dor/métodos , Dor Pós-Operatória/tratamento farmacológico , Acetaminofen/administração & dosagem , Acetaminofen/uso terapêutico , Adulto , Idoso , Analgésicos/administração & dosagem , Implante Coclear/efeitos adversos , Codeína/administração & dosagem , Codeína/uso terapêutico , Orelha Média/cirurgia , Feminino , Humanos , Ibuprofeno/administração & dosagem , Ibuprofeno/uso terapêutico , Masculino , Pessoa de Meia-Idade , Medição da Dor , Estudos Prospectivos
12.
Otol Neurotol ; 43(2): 256-262, 2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-34739430

RESUMO

BACKGROUND: Balloon dilation of the eustachian tube is a new therapeutic option for eustachian tube dysfunction. One of the limiting factors of wider adoption of this technique in many parts of the world is the high cost of the devices, in spite of regulatory approval of safety. OBJECTIVE: Evaluate the performance and usability of standard less-expensive endovascular balloons for eustachian tube dilation in comparison to an approved device in a preclinical study. STUDY DESIGN: Comparative cadaver feasibility study. SETTING: University tertiary care facility. METHODS: Ten eustachian tube dilations were performed with an approved eustachian tube dilation device. Ten other procedures were carried out with an endovascular balloon of similar dimensions. Cone beam computerized tomography was performed to evaluate the extent of dilation and possible damages. The lumen and mucosal lining were inspected endoscopically post-dilation. Volume measurements were compared before and after the procedure in both groups using contrast enhancement. RESULTS: All 20 eustachian tube dilations were carried out successfully. No tissue damages could be identified on cone-beam computerized tomography or via endoscopic examination. There was a statistically significant difference of eustachian tube volumes between pre- and post-dilations, with no statistically significant difference between the devices. CONCLUSION: Eustachian tube dilation with a less costly endovascular balloon achieved similar results to an approved eustachian tube dilation device. No damages or any other safety concerns were identified in a cadaver study.


Assuntos
Otopatias , Tuba Auditiva , Cadáver , Dilatação/métodos , Otopatias/cirurgia , Tuba Auditiva/cirurgia , Estudos de Viabilidade , Humanos
13.
Otol Neurotol ; 42(10): e1464-e1469, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34353979

RESUMO

OBJECTIVE: The Glasgow Benefit Inventory (GBI) is a health-related quality of life instrument used to detect changes in health status following otolaryngologic interventions. Despite its use in cochlear implant literature, assessment of utility, reliability, and validity of GBI in an adult cochlear implants (CI) patient population has yet to be performed. STUDY DESIGN: Retrospective case series. SETTING: Academic, tertiary referral center. PATIENTS: Postlingually deafened, adult CI patients with at least 1 year of device use. INTERVENTIONS: Five hundred fifty-two patients were administered GBI questionnaires at least 1 year following CI activation during follow-up visits. MAIN OUTCOME MEASURES: GBI total and subscale scoring were compared to either the Hearing Handicap Inventory for Adults or Hearing Handicap Inventory for the Elderly. Moreover, a factor analysis and Cronbach's alpha were performed to determine GBI validity and internal reliability, respectively. RESULTS: The average overall GBI score was 38.6 ±â€Š21.7. This was weakly correlated to the reduction in Hearing Handicap Inventory for Adults/Hearing Handicap Inventory for the Elderly (τb = 0.282, p < 0.05). High factor loading with minimal cross-loading was noted on a three-factor solution, which emulated the original GBI development. Internal reliability was acceptable for the general benefit (α = 0.913) and social support subclasses (α = 0.706), whereas physical health's was low (α = 0.643). CONCLUSIONS: Although GBI possesses adequate convergent and discriminant validity with acceptable reliability, its routine use to capture CI-specific health-related changes should not supersede validated CI-specific QoL instruments.


Assuntos
Implante Coclear , Implantes Cocleares , Adulto , Idoso , Humanos , Qualidade de Vida , Reprodutibilidade dos Testes , Estudos Retrospectivos , Inquéritos e Questionários , Resultado do Tratamento
14.
J Otolaryngol Head Neck Surg ; 50(1): 38, 2021 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-34158125

RESUMO

BACKGROUND: The opioid epidemic is a significant public health crisis challenging the lives of North Americans. Interestingly, this problem does not exist to the same extent in Europe. Surgeons play a significant role in prescribing opioids, especially in the context of post-operative pain management. The aim of this study was to compare the post-surgical prescribing patterns of otologists comparing Canada and Austria. METHODS: An online questionnaire was sent to 33 Canadian and 32 Austrian surgeons, who perform otologic surgery on a regular basis. Surgeons were asked to answer some questions about their background as well as typical prescribing patterns for postoperative pain medication for different ear surgeries (cochlear implant, stapedotomy, tympanoplasty). In addition, surgeons were asked about the typical use of local anesthetics for pain control at the end of a procedure. Otologists gave an estimate how confident they were that their therapy and prescriptions provide sufficient pain control to their patients. RESULTS: Analysis of the returned questionnaires showed that opioids are more commonly prescribed in Canada than in Austria. Nonsteroidal anti-inflammatory drugs are used for postoperative pain more regularly after ear surgery in Austria, as opposed to Canada. Some of the prescribed drugs by European otologists are not available in North America. The use of local anesthetics at the end of surgery is not common in Austria. Surgeons´ confidence that the prescribed pain medication was sufficient to control postoperative symptoms was higher in the group not prescribing opioids than in the group that did routinely prescribe opioids. CONCLUSION: Prescribing patterns differ substantially between the two evaluated countries. This data suggests an opportunity to reduce opioid prescriptions after otologic surgeries. Studies to evaluate pain after these operations as well as efficacy of analgesics following ear surgery are an important next step.


Assuntos
Analgésicos Opioides/efeitos adversos , Prescrições de Medicamentos/estatística & dados numéricos , Epidemia de Opioides/estatística & dados numéricos , Procedimentos Cirúrgicos Otológicos/métodos , Dor Pós-Operatória/prevenção & controle , Adulto , Áustria/epidemiologia , Canadá/epidemiologia , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Dor Pós-Operatória/epidemiologia
15.
Otol Neurotol ; 41(2): 196-201, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31834209

RESUMO

OBJECTIVE: Explore patient characteristics associated with tinnitus improvement after cochlear implantation. STUDY DESIGN: Retrospective cohort. SETTING: Tertiary referral. PATIENTS: Adults with bilateral severe-to-profound hearing loss and tinnitus. INTERVENTIONS: Unilateral cochlear implantation. RESULTS: From 1996 to 2018, 358 patients endorsed pre-implant tinnitus and had ascertainable tinnitus status at 1-year. Clinically significant improvement in Tinnitus Handicap Inventory (THI) (reduction by at least 7-points) was observed in 262 (73.2%) patients, of whom 155 (59.2%) reported complete resolution. Of the 24 characteristics explored, four were identified as independent predictors of improved tinnitus in logistic regression models. In a multivariable model including identified independent predictors, each 10-percentage point increase in baseline hearing in noise test was associated with an 14% reduction in odds of tinnitus resolution or clinically significant improvement (odds ratio [OR] 0.86, 95% confidence limits [CL] 0.77, 0.96) and preoperative use of a hearing aid in the contralateral ear was associated with a 72% reduction (OR 0.28; 95% CL 0.11, 0.73). Each 10-point increase in baseline Hearing Handicap Inventory for Adults (HHI) score was associated with a 28% increase in odds of tinnitus improvement (OR 1.28; 95% CL 1.07, 1.54). Higher baseline burden of tinnitus was associated with higher odds of tinnitus improvement (OR 1.21 per 10-point THI increase, 95% CL 1.04, 1.40). CONCLUSIONS: Worse residual hearing and higher baseline hearing and tinnitus handicap are associated with higher odds of tinnitus improvement. Expectations of patients seeking reduced tinnitus burden following cochlear implantation should be managed by counselling regarding odds of tinnitus improvement compared to those with similar residual hearing and tinnitus burden.


Assuntos
Implante Coclear , Implantes Cocleares , Zumbido , Adulto , Audição , Humanos , Estudos Retrospectivos , Zumbido/cirurgia , Resultado do Tratamento
16.
Otol Neurotol ; 40(5): 595-601, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31083080

RESUMO

OBJECTIVE: Determine association of advancements in speech processor technology with improvements in speech recognition outcomes. STUDY DESIGN: Retrospective cohort. SETTING: Tertiary referral center. PATIENTS: Adult unilateral cochlear implant (CI) recipients. INTERVENTION: Increasing novelty of speech processor defined by year of market availability. MAIN OUTCOME MEASURES: Consonant-Nucleus-Consonant (CNC) and Hearing in Noise Test (HINT) in quiet. RESULTS: From 1991 to 2016, 1,111 CNC scores and 1,121 HINT scores were collected from 351 patients who had complete data. Mean post-implantation CNC score was 53.8% and increased with more recent era of implantation (p < 0.001, analysis of variance [ANOVA]). Median HINT score was 87.0% and did not significantly vary with implantation era (p = 0.06, ANOVA). Multivariable generalized linear models were fitted to estimate the effect of speech processor novelty on CNC and HINT scores, each accounting for clustering of scores within patients and characteristics known to influence speech recognition outcomes. Each 5-year increment in speech processor novelty was independently associated with an increase in CNC score by 2.85% (95% confidence limits [CL] 0.26, 5.44%) and was not associated with change in HINT scores (p = 0.30). CONCLUSION: Newer speech processors are associated with improved CNC scores independent of the year of device implantation and expanding candidacy criteria. The lack of association with HINT scores can be attributed to a ceiling effect, suggesting that HINT in quiet may not be an informative test of speech recognition in the modern CI recipient. The implications of these findings with respect to appropriate interval of speech processor upgrades are discussed.


Assuntos
Audiologia/instrumentação , Implantes Cocleares , Percepção da Fala , Adulto , Análise de Variância , Audiologia/tendências , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ruído , Estudos Retrospectivos
17.
Otol Neurotol ; 40(2): e82-e88, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30570612

RESUMO

OBJECTIVE: Assess speech outcomes in unilateral cochlear implant (CI) recipients after addition of a wireless contralateral routing of signals (CROS) microphone. STUDY DESIGN: Prospective cohort study. SETTING: Ambulatory. PATIENTS: Sixteen adult unilateral CI users with nonserviceable hearing on the contralateral side were recruited. Those with AzBio sentence scores of 40 to 80% or Hearing in Noise Test - Quiet (HINT-Q) scores of 60 to 90% with a CI alone were eligible participants. INTERVENTION: Speech testing was carried out with the CROS on and off. MAIN OUTCOME MEASURE: Speech recognition. RESULTS: In the consonant-nucleus-consonant test presented in quiet from the front, word scores were 64.4 (CI) and 63.8% (CI + CROS) (p = 0.72), and phoneme scores were 80.2 (CI) and 80.8% (CI + CROS) (p = 0.65). In AzBio sentence testing in quiet, with the signals projected from the contralateral, front, or ipsilateral to the CI, speech perception with the CI alone was 60.8, 75.9, and 79.1%. With the addition of the CROS microphone, using the same speaker arrangement, speech perception was 69.8 (p < 0.05), 71.8 (p = 0.05), and 71.8 (p < 0.05). In AzBio sentence testing in noise, speech perception with the CI alone was 18.6, 45.3, and 56.3% when signals were projected from contralateral, front, and ipsilateral sides to the CI. The addition of the CROS microphone led to speech perception of 45.3 (p < 0.05), 45.3 (p = 0.86), and 51.4% (p = 0.27) in the same paradigm. CONCLUSIONS: Addition of a wireless CROS microphone to a unilateral CI recipient can improve users' perception of speech in both quiet and noise if speech signals come from the deaf ear, mitigating the head shadow effect.


Assuntos
Implante Coclear , Implantes Cocleares , Audição , Percepção da Fala , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ruído , Estudos Prospectivos
18.
J Otolaryngol Head Neck Surg ; 46(1): 62, 2017 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-29166946

RESUMO

BACKGROUND: With an increasing proportion of the population living in cities, mass transportation has been rapidly expanding to facilitate the demand, yet there is a concern that mass transit has the potential to result in excessive exposure to noise, and subsequently noise-induced hearing loss. METHODS: Noise dosimetry was used to measure time-integrated noise levels in a representative sample of the Toronto Mass Transit system (subway, streetcar, and buses) both aboard moving transit vehicles and on boarding platforms from April - August 2016. 210 measurements were conducted with multiple measurements approximating 2 min on platforms, 4 min within a vehicle in motion, and 10 min while in a car, on a bike or on foot. Descriptive statistics for each type of transportation, and measurement location (platform vs. vehicle) was computed, with measurement locations compared using 1-way analysis of variance. RESULTS: On average, there are 1.69 million riders per day, who are serviced by 69 subway stations, and 154 streetcar or subway routes. Average noise level was greater in the subway and bus than in the streetcar (79.8 +/- 4.0 dBA, 78.1 +/- 4.9 dBA, vs 71.5 +/-1.8 dBA, p < 0.0001). Furthermore, average noise measured on subway platforms were higher than within vehicles (80.9 +/- 3.9 dBA vs 76.8 +/- 2.6 dBA, p < 0.0001). Peak noise exposures on subway, bus and streetcar routes had an average of 109.8 +/- 4.9 dBA and range of 90.4-123.4 dBA, 112.3 +/- 6.0 dBA and 89.4-128.1 dBA, and 108.6 +/- 8.1 dBA and 103.5-125.2 dBA respectively. Peak noise exposures exceeded 115 dBA on 19.9%, 85.0%, and 20.0% of measurements in the subway, bus and streetcar respectively. CONCLUSIONS: Although the mean average noise levels on the Toronto transit system are within the recommended level of safe noise exposure, cumulative intermittent bursts of impulse noise (peak noise exposures) particularly on bus routes have the potential to place individuals at risk for noise induced hearing loss.


Assuntos
Exposição Ambiental/efeitos adversos , Ruído dos Transportes/efeitos adversos , Ruído dos Transportes/estatística & dados numéricos , Meios de Transporte/métodos , Saúde da População Urbana , Canadá , Feminino , Humanos , Masculino , Avaliação das Necessidades , Projetos Piloto , Fatores de Risco , Inquéritos e Questionários , População Urbana
20.
Otol Neurotol ; 38(8): e237-e239, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28806332

RESUMO

: The rising incidence of dementia locally and worldwide has now reached a critical level. The associated costs associated with these individuals will ultimately be untenable to most societies. Furthermore there is a paucity of highly effective treatments. However, the recent discovery of the association of hearing loss and dementia may open many potential opportunities. Although we still are acquiring knowledge on the pathophysiology of this association, clinicians are hopeful that our current highly effective treatments of hearing loss may ultimately be shown to have a positive effect on those with dementia.


Assuntos
Demência/complicações , Perda Auditiva/epidemiologia , Perda Auditiva/etiologia , Custos e Análise de Custo , Surdez/epidemiologia , Surdez/etiologia , Humanos , Incidência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA