Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38662427

RESUMO

Objective: A subgroup analysis of the Hypoglycemia Awareness Restoration Programme for people with type 1 diabetes and problematic hypoglycemia persisting despite optimized care (HARPdoc) trial was conducted to explore the impact of Blood Glucose Awareness Training (BGAT, a hypoglycemia awareness training program) and the HARPdoc (a psychoeducation addressing unhelpful hypoglycemia beliefs) in reducing severe hypoglycemia (SH) in individuals using advanced diabetes technologies (ADTs). Methods: Data from trial participants who utilized ADTs, including continuous glucose monitors or automated insulin delivery systems, were extracted. Generalized linear mixed-effects models with Poisson distribution or linear mixed-effects models were used to evaluate SH incidence, and Gold questionnaire, Attitudes to Awareness of Hypoglycemia (A2A), Problem Areas in Diabetes (PAID), Hospital Anxiety and Depress Scale (HADS)-anxiety, and HADS-depression scores as measures of hypoglycemia awareness, unhelpful hypoglycemia beliefs, diabetes distress, and anxiety and depression symptoms, respectively. Results: In the 45 participants using ADTs, the BGAT and HARPdoc interventions both reduced SH incidence by more than 50% (P < 0.0001) and yielded improvements in hypoglycemia awareness (P < 0.05). HARPdoc outperformed BGAT in reducing SH at month 24 (P = 0.01). HARPdoc also mitigated unhelpful hypoglycemia beliefs (P < 0.0001), diabetes distress (P < 0.05), and anxiety symptoms (P < 0.05); BGAT demonstrated no significant impacts in these respects. Neither HARPdoc nor BGAT had significant effects on depression symptoms. Conclusion: Psychoeducation (BGAT and HARPdoc) was effective in reducing SH in people using ADTs. HARPdoc may also provide greater long-term SH reduction and improves psychological well-being in this patient group.

2.
J Diabetes Sci Technol ; 18(3): 562-569, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38563491

RESUMO

BACKGROUND: We evaluated the feasibility of real-time continuous glucose monitoring (CGM) for titrating continuous intravenous insulin infusion (CII) to manage hyperglycemia in postoperative individuals in the cardiovascular intensive care unit and assessed their accuracy, nursing acceptance, and postoperative individual satisfaction. METHODS: Dexcom G6 CGM devices were applied to 59 postsurgical patients with hyperglycemia receiving CII. A hybrid approach combining CGM with periodic point-of-care blood glucose (POC-BG) tests with two phases (initial-ongoing) of validation was used to determine CGM accuracy. Mean and median absolute relative differences and Clarke Error Grid were plotted to evaluate the CGM accuracy. Surveys of nurses and patients on the use of CGMs experience were conducted and results were analyzed. RESULTS: In this cohort (mean age 64, 32% female, 32% with diabetes) with 864 paired POC-BG and CGM values analyzed, mean and median absolute relative difference between POC-BG and CGM values were 13.2% and 9.8%, respectively. 99.7% of paired CGM and POC-BG were in Zones A and B of the Clarke Error Grid. Responses from nurses reported CGMs being very or quite convenient (n = 28; 93%) and it was favored over POC-BG testing (n = 28; 93%). Majority of patients (n = 42; 93%) reported their care process using CGM as being good or very good. CONCLUSION: This pilot study demonstrates the feasibility, accuracy, and nursing convenience of adopting CGM via a hybrid approach for insulin titration in postoperative settings. These findings provide robust rationale for larger confirmatory studies to evaluate the benefit of CGM in postoperative care to improve workflow, enhance health outcomes, and cost-effectiveness.


Assuntos
Monitoramento Contínuo da Glicose , Diabetes Mellitus , Hipoglicemiantes , Sistemas de Infusão de Insulina , Insulina , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Glicemia/análise , Glicemia/efeitos dos fármacos , Diabetes Mellitus/sangue , Diabetes Mellitus/tratamento farmacológico , Estudos de Viabilidade , Hiperglicemia/sangue , Hiperglicemia/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , Infusões Intravenosas , Insulina/administração & dosagem , Unidades de Terapia Intensiva
3.
Diabetes Res Clin Pract ; 209: 111596, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38428746

RESUMO

AIMS: To evaluate relationships of hypoglycemia awareness, hypoglycemia beliefs, and continuous glucose monitoring (CGM) glycemic profiles with anxiety and depression symptoms in adults with type 1 diabetes (T1D) who use CGM. METHODS: A cross-sectional survey and data collections were completed with 196 T1D adults who used CGM (59% also used automated insulin delivery devices (AIDs)). We assessed hypoglycemia awareness (Gold instrument), hypoglycemia beliefs (Attitudes to Awareness of Hypoglycemia instrument), CGM glycemic profiles, demographics, and anxiety and depression symptoms (Hospital Anxiety and Depression Scale). Analysis included simple and multiple linear regression analyses. RESULTS: Lower hypoglycemia awareness, weaker "hypoglycemia concerns minimized" beliefs, stronger "hyperglycemia avoidance prioritized" beliefs were independently associated with higher anxiety symptoms (P < 0.05), with similar trends in both subgroups using and not using AIDs. Lower hypoglycemia awareness were independently associated with greater depression symptoms (P < 0.05). In participants not using AIDs, more time in hypoglycemia was related to less anxiety and depression symptoms (P < 0.05). Being female and younger were independently associated with higher anxiety symptoms, while being younger was also independently associated with greater depression symptoms (P < 0.05). CONCLUSION: Our findings revealed relationships of impaired hypoglycemia awareness, hypoglycemia beliefs, CGM-detected hypoglycemia with anxiety and depression symptoms in T1D adults who use CGMs.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Adulto , Humanos , Feminino , Masculino , Diabetes Mellitus Tipo 1/complicações , Glicemia , Automonitorização da Glicemia , Monitoramento Contínuo da Glicose , Estudos Transversais , Depressão/diagnóstico , Depressão/epidemiologia , Depressão/etiologia , Hipoglicemia/etiologia , Hipoglicemia/complicações , Ansiedade/diagnóstico , Ansiedade/epidemiologia , Ansiedade/etiologia , Hipoglicemiantes/efeitos adversos , Insulina/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA