Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
1.
Kidney Int ; 103(6): 1180-1192, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36868377

RESUMO

The ASCEND-NHQ trial evaluated the effects of daprodustat on hemoglobin and the Medical Outcomes Study 36-item Short Form Survey (SF-36) Vitality score (fatigue) in a multicenter, randomized, double-blind, placebo-controlled trial. Adults with chronic kidney disease (CKD) stages 3-5, hemoglobin 8.5-10.0 g/dl, transferrin saturation 15% or more, and ferritin 50 ng/ml or more without recent erythropoiesis-stimulating agent use were randomized (1:1) to oral daprodustat or placebo to achieve and maintain target hemoglobin of 11-12 g/dl over 28 weeks. The primary endpoint was the mean change in hemoglobin between baseline and the evaluation period (Weeks 24-28). Principal secondary endpoints were proportion of participants with a 1 g/dl or more increase in hemoglobin and mean change in the Vitality score between baseline and Week 28. Outcome superiority was tested (1-sided alpha level of 0.025). Overall, 614 participants with non-dialysis-dependent CKD were randomized. The adjusted mean change in hemoglobin from baseline to the evaluation period was greater with daprodustat (1.58 vs 0.19 g/dl). The adjusted mean treatment difference (AMD) was significant at 1.40 g/dl (95% confidence interval 1.23, 1.56). A significantly greater proportion of participants receiving daprodustat showed a 1 g/dl or greater increase in hemoglobin from baseline (77% vs 18%). The mean SF-36 Vitality score increased by 7.3 and 1.9 points with daprodustat and placebo, respectively; a clinically and statistically significant 5.4 point Week 28 AMD increase. Adverse event rates were similar (69% vs 71%); relative risk 0.98, (95% confidence interval 0.88, 1.09). Thus, in participants with CKD stages 3-5, daprodustat resulted in a significant increase in hemoglobin and improvement in fatigue without an increase in the overall frequency of adverse events.


Assuntos
Hematínicos , Insuficiência Renal Crônica , Adulto , Humanos , Qualidade de Vida , Hemoglobinas/análise , Barbitúricos/efeitos adversos , Hematínicos/efeitos adversos , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/tratamento farmacológico
2.
J Stroke Cerebrovasc Dis ; 32(2): 106891, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36473399

RESUMO

OBJECTIVES: We aimed to summarize the known risk of vasculopathy (stroke, myocardial infarction [MI], and transient ischemic attack [TIA]) after herpes zoster (HZ) and the impact of antiviral treatment and vaccination against HZ on the risk of vasculopathy. MATERIALS AND METHODS: A narrative literature review was conducted in PubMed to identify evidence published in the past 15 years that was relevant to the scope of this article. RESULTS: Ten studies reported that HZ was associated with an increased risk of stroke and one UK study reported no association. Four studies reported that HZ was associated with an increased risk of MI, and four reported that HZ was associated with an increased risk of TIA. Two studies reported that antiviral treatment was associated with a reduced risk of stroke and an additional two studies reported no association between antiviral treatment and the risk of stroke. In addition, two studies reported that vaccination against HZ using the live zoster vaccine (ZVL) was associated with a reduced risk of stroke, and an additional two studies reported that the risk of stroke or MI after HZ was similar between ZVL vaccinated and unvaccinated individuals. CONCLUSIONS: HZ is associated with an increased risk of stroke, MI, or TIA (strongest association is between HZ and stroke). Further studies are needed to determine whether antiviral treatment or ZVL vaccination influence the risk of HZ-associated vasculopathy. In addition, the effect of the recombinant zoster vaccine on the risk of HZ-associated vasculopathy should be studied.


Assuntos
Vacina contra Herpes Zoster , Herpes Zoster , Ataque Isquêmico Transitório , Infarto do Miocárdio , Acidente Vascular Cerebral , Humanos , Vacina contra Herpes Zoster/efeitos adversos , Ataque Isquêmico Transitório/diagnóstico , Ataque Isquêmico Transitório/epidemiologia , Ataque Isquêmico Transitório/etiologia , Herpes Zoster/complicações , Herpes Zoster/epidemiologia , Herpes Zoster/prevenção & controle , Herpesvirus Humano 3 , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Vacinação/efeitos adversos , Infarto do Miocárdio/induzido quimicamente , Antivirais/efeitos adversos
3.
Clin Pharmacol Drug Dev ; 11(5): 562-575, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35355447

RESUMO

Daprodustat is a hypoxia-inducible factor-prolyl hydroxylase inhibitor in development for treatment of anemia of chronic kidney disease. We evaluated the role of hepatic impairment on daprodustat pharmacokinetics, pharmacodynamics, and tolerability. Participants with mild (Child-Pugh Class A, score 5-6) and moderate (Child-Pugh Class B, score 7-9) hepatic impairment and matched healthy controls were administered single 6-mg doses of daprodustat. Exposure parameters were determined for daprodustat and its six metabolites. Comparisons resulted in 1.5- and 2.0-fold higher daprodustat Cmax and area under the curve (AUC) exposures in participants with mild and moderate hepatic impairment, respectively, versus controls; Cmax in mild hepatic impairment was comparable to controls. Similarly, aligned with parent drug, unbound daprodustat Cmax and AUC exposures increased 1.6- to 2.3-fold in hepatic-impaired participants versus controls, and metabolite exposures were 1.2- to 2.0-fold higher in participants with hepatic impairment. Erythropoeitin (EPO) baseline-corrected AUC exposures were between 0.3-fold lower and 2.2-fold higher in matched controls versus hepatic-impaired participants. No serious or study drug-related adverse events were reported. Daprodustat exposure was increased in participants with moderate and mild hepatic impairment compared with matched controls; however, no meaningful differences in EPO were observed and no new safety concerns were identified (ClinicalTrials.gov: NCT03223337).


Assuntos
Hepatopatias , Inibidores de Prolil-Hidrolase , Barbitúricos , Feminino , Glicina/efeitos adversos , Glicina/análogos & derivados , Glicina/farmacocinética , Humanos , Hepatopatias/metabolismo , Masculino , Inibidores de Prolil-Hidrolase/efeitos adversos , Inibidores de Prolil-Hidrolase/farmacocinética
4.
Clin Pharmacol Drug Dev ; 10(12): 1419-1431, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34713596

RESUMO

Daprodustat, an oral hypoxia-inducible factor prolyl hydroxylase inhibitor, is being investigated for treatment of anemia in chronic kidney disease. This phase 1, nonrandomized, 2-period, crossover study in 6 healthy men characterized the absorption, distribution, and excretion of daprodustat when administered as oral and intravenous (IV) doses of unlabeled and radiolabeled daprodustat ([14 C]-GSK1278863). Tolerability and pharmacokinetic properties of daprodustat, and its 6 metabolites in the systemic circulation, were also evaluated. The mean recovery of radiolabeled daprodustat was ≈95% by day 5, with the majority in feces and minor renal elimination, indicating that daprodustat and metabolites are primarily eliminated via hepatobiliary and fecal routes. Approximately 40% of total circulating radioactivity in plasma following both IV and oral administration was daprodustat; thus, 60% was attributed to metabolites. It was estimated that ≈80% of daprodustat was absorbed across the gastrointestinal tract, and ≈18% cleared by hepatic extraction. Pharmacokinetics were essentially dose proportional, with moderate (≈66%) oral tablet bioavailability. Following IV administration, daprodustat plasma clearance (19.3 L/h) and volume of distribution (14.6 L) were low, suggesting low tissue distribution outside systemic circulation with likely low penetration into tissues. Daprodustat was generally well tolerated, with no deaths or serious or significant adverse events reported.


Assuntos
Barbitúricos , Glicina , Disponibilidade Biológica , Estudos Cross-Over , Glicina/análogos & derivados , Humanos , Masculino
5.
Circ Genom Precis Med ; 13(4): e002804, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32605384

RESUMO

BACKGROUND: Left ventricular ejection fraction (EF) is an indicator of cardiac function, usually assessed in individuals with heart failure and other cardiac conditions. Although family studies indicate that EF has an important genetic component with heritability estimates up to 0.61, to date only 6 EF-associated loci have been reported. METHODS: Here, we conducted a genome-wide association study (GWAS) of EF in 26 638 adults from the Genetic Epidemiology Research on Adult Health and Aging and the UK Biobank cohorts. RESULTS: A meta-analysis combining results from Genetic Epidemiology Research on Adult Health and Aging and UK Biobank identified a novel locus: TMEM40 on chromosome 3p25 (rs11719526; ß=0.47 and P=3.10×10-8) that replicated in Biobank Japan and confirmed recent findings implicating the BAG3 locus on chromosome 10q26 in EF variation, with the strongest association observed for rs17617337 (ß=-0.83 and P=8.24×10-17). Although the minor allele frequencies of TMEM40 rs11719526 were generally common (between 0.13 and 0.44) in different ethnic groups, BAG3 rs17617337 was rare (minor allele frequencies<0.05) in Asian and African ancestry populations. These associations were slightly attenuated, after considering antecedent cardiac conditions (ie, heart failure/cardiomyopathy, hypertension, myocardial infarction, atrial fibrillation, valvular disease, and revascularization procedures). This suggests that the effects of the lead variants at TMEM40 or BAG3 on EF are largely independent of these conditions. CONCLUSIONS: In this large and multiethnic study, we identified 2 loci, TMEM40 and BAG3, associated with EF at a genome-wide significance level. Identifying and understanding the genetic determinants of EF is important to better understand the pathophysiology of this strong correlate of cardiac outcomes and to help target the development of future therapies.


Assuntos
Estudo de Associação Genômica Ampla , Função Ventricular Esquerda/genética , Proteínas Adaptadoras de Transdução de Sinal/genética , Idoso , Proteínas Reguladoras de Apoptose/genética , Povo Asiático/genética , População Negra/genética , Feminino , Frequência do Gene , Loci Gênicos , Variação Genética , Insuficiência Cardíaca/genética , Humanos , Masculino , Proteínas de Membrana/genética , Pessoa de Meia-Idade , Característica Quantitativa Herdável , População Branca/genética
6.
BMJ Open Qual ; 7(3): e000074, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30057949

RESUMO

BACKGROUND: The use of the WHO safe surgery checklist has been shown to reduce morbidity and mortality from surgical procedures. However, whether a WHO-style safe procedure checklist can improve safety in the cardiac catheterisation laboratory (CCL) has not previously been investigated. OBJECTIVES: The authors sought to design and implement a safe procedure checklist suitable for all CCL procedures, and to assess its impact over the course of 1 year. METHODS: In the first 3 months, weekly PDSA cycles (Plan-Do-Study-Act) were used to optimise the design of the checklist through testing and staff feedback, and team briefing sessions were introduced before each procedure list. The impact of the checklist and team briefs was assessed by analysing in-house procedural data subsequently submitted to national audit databases. Staff and patient questionnaires were performed throughout the year. RESULTS: Introduction of the checklist was associated with a significant reduction of 3 min in average turnaround time (95% CI 25 s to 6 min, p=0.027). Similarly, an initial reduction in patient radiation exposure was recorded (dose area product reduction of 641.5 cGy/cm2; 95% CI 255.9 to 1027.1, p=0.002). The rate of reported complications from all procedures fell significantly from 2.0% in 2012/2013 (95% CI 1.6% to 2.4%) to 0.8% in 2013/2014 (95% CI 0.6% to 1.1%, p≤0.001). Staff climate questionnaires showed that technicians and radiographers gave more positive responses at the end of the study period compared with the beginning (p=0.001). CONCLUSIONS: The use of a team brief and WHO-derived safe procedure checklist in the CCL was associated with decreased radiation exposure, fewer procedural complications, faster turnarounds and improved staff experience.

7.
Innovations (Phila) ; 11(3): 174-8, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27537190

RESUMO

OBJECTIVE: A small number of transcatheter mitral valve implants (TMVIs) have been reported using devices designed to treat secondary mitral regurgitation (MR). However, MR has many etiologies, and patients have a broad spectrum of annular size, geometry, and lesions. There are a number of technical challenges for TMVI including left ventricular outflow tract obstruction and paravalvular MR. Thirty days' outcome of first-in-man implants with a novel TMVI device is reported. METHODS: The Tendyne TMVI system consists of a porcine pericardial valve in a tethered nitinol frame. An apical tether fixed to an epicardial pad stabilizes the device. The device is fully repositionable and retrievable even after complete deployment. Preoperative assessment was performed with 3-dimensional (3D) transesophageal echocardiogram and multislice computed tomography to define annular dimensions, geometry, and guide surgical access. Three patients were deemed not to be candidates for conventional surgery or for treatment with any Conformitè Européenne-marked device by Heart Team Evaluation. They were a 68-year-old woman with prior coronary artery bypass grafts and severe functional MR; a 75-year-old man with prior coronary bypass grafts, significant renal dysfunction, and severe degenerative MR; and a frail 86-year-old man with severe degenerative MR. Each had a TMVI via a transapical approach through a left minithoracotomy. Apical tether tension was adjusted to optimize device position. RESULTS: Implantation was guided by 2D and 3D transesophageal echocardiogram. The apical pad facilitated LV apical closure. There were no procedural complications. No patient had hemodynamically significant residual MR or left ventricular outflow tract obstruction, and there was no significant mitral gradient. All patients were discharged to their own home (the third on the fifth postoperative day), all with significant improvement in their symptoms. All were alive and well 30 days after implant. Two patients with existing conduction abnormalities had cardiac resynchronisation therapy after the procedure, and one patient had para valvular leak (PVL) with evidence of hemolysis at 30 days, which reduced in severity with conservative treatment. CONCLUSIONS: The first-in-man experience with the Tendyne TMVI system is promising. Valve stabilization by an apical tether is a novel way to address some of the challenges of TMVI. The unique Tendyne design features may offer potential for its use across a wide range of mitral valve pathologies.


Assuntos
Insuficiência da Valva Mitral/cirurgia , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Desenho de Prótese , Índice de Gravidade de Doença , Resultado do Tratamento
8.
Artigo em Inglês | MEDLINE | ID: mdl-27418610

RESUMO

BACKGROUND: Cardiovascular magnetic resonance (CMR) can provide important structural information in patients undergoing transcatheter aortic valve implantation. Although CMR is considered the standard of reference for measuring ventricular volumes and mass, the relationship between CMR findings of right ventricular (RV) function and outcomes after transcatheter aortic valve implantation has not previously been reported. METHODS AND RESULTS: A total of 190 patients underwent 1.5 Tesla CMR before transcatheter aortic valve implantation. Steady-state free precession sequences were used for aortic valve planimetry and to assess ventricular volumes and mass. Semiautomated image analysis was performed by 2 specialist reviewers blinded to patient treatment. Patient follow-up was obtained from the Office of National Statistics mortality database. The median age was 81.0 (interquartile range, 74.9-85.5) years; 50.0% were women. Impaired RV function (RV ejection fraction ≤50%) was present in 45 (23.7%) patients. Patients with RV dysfunction had poorer left ventricular ejection fractions (42% versus 69%), higher indexed left ventricular end-systolic volumes (96 versus 40 mL), and greater indexed left ventricular mass (101 versus 85 g/m(2); P<0.01 for all) than those with normal RV function. Median follow-up was 850 days; 21 of 45 (46.7%) patients with RV dysfunction died, compared with 43 of 145 (29.7%) patients with normal RV function (P=0.035). After adjustment for significant baseline variables, both RV ejection fraction ≤50% (hazard ratio, 2.12; P=0.017) and indexed aortic valve area (hazard ratio, 4.16; P=0.025) were independently associated with survival. CONCLUSIONS: RV function, measured on preprocedural CMR, is an independent predictor of mortality after transcatheter aortic valve implantation. CMR assessment of RV function may be important in the risk stratification of patients undergoing transcatheter aortic valve implantation.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter , Disfunção Ventricular Direita/epidemiologia , Função Ventricular Direita , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Ecocardiografia , Feminino , Humanos , Estimativa de Kaplan-Meier , Londres/epidemiologia , Imageamento por Ressonância Magnética , Masculino , Valor Preditivo dos Testes , Prevalência , Modelos de Riscos Proporcionais , Fatores de Risco , Índice de Gravidade de Doença , Volume Sistólico , Sístole , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/mortalidade , Disfunção Ventricular Direita/fisiopatologia
9.
Eur J Heart Fail ; 18(6): 703-12, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26990920

RESUMO

AIM: Heart failure with preserved ejection fraction (HFpEF) is associated with increased sympathetic nervous system (SNS) tone. Attenuating the SNS with renal denervation (RDT) might be helpful and there are no data currently in humans with HFpEF. METHODS AND RESULTS: In this single-centre, randomized, open-controlled study we included 25 patients with HFpEF [preserved left ventricular (LV) ejection fraction, left atrial (LA) dilatation or LV hypertrophy and raised B-type natriuretic peptide (BNP) or echocardiographic assessment of filling pressures]. Patients were randomized (2:1) to RDT with the Symplicity™ catheter or continuing medical therapy. The primary success criterion was not met in that there were no differences between groups at 12 months for Minnesota Living with Heart Failure Questionnaire score, peak oxygen uptake (VO2 ) on exercise, BNP, E/e', LA volume index or LV mass index. A greater proportion of patients improved at 3 months in the RDT group with respect to VO2 peak (56% vs. 13%, P = 0.025) and E/e' (31% vs. 13%, P = 0.04). Change in estimated glomerular filtration rate was comparable between groups. Two patients required plain balloon angioplasty during the RDT procedure to treat renal artery wall oedema. CONCLUSION: This study was terminated early because of difficulties in recruitment and was underpowered to detect whether RD improved the endpoints of quality of life, exercise function, biomarkers, and left heart remodelling. The procedure was safe in patients with HFpEF, although two patients did require intraprocedure renal artery dilatation.


Assuntos
Denervação , Insuficiência Cardíaca/cirurgia , Artéria Renal/inervação , Simpatectomia , Idoso , Idoso de 80 Anos ou mais , Ecocardiografia , Tolerância ao Exercício , Feminino , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/patologia , Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Humanos , Hipertrofia Ventricular Esquerda/diagnóstico por imagem , Hipertrofia Ventricular Esquerda/etiologia , Masculino , Peptídeo Natriurético Encefálico/sangue , Tamanho do Órgão , Consumo de Oxigênio , Volume Sistólico
10.
Clin Res Cardiol ; 105(6): 544-52, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26802018

RESUMO

BACKGROUND: Renal denervation (RDN) may lower blood pressure (BP); however, it is unclear whether medication changes may be confounding results. Furthermore, limited data exist on pattern of ambulatory blood pressure (ABP) response-particularly in those prescribed aldosterone antagonists at the time of RDN. METHODS: We examined all patients treated with RDN for treatment-resistant hypertension in 18 UK centres. RESULTS: Results from 253 patients treated with five technologies are shown. Pre-procedural mean office BP (OBP) was 185/102 mmHg (SD 26/19; n = 253) and mean daytime ABP was 170/98 mmHg (SD 22/16; n = 186). Median number of antihypertensive drugs was 5.0: 96 % ACEi/ARB; 86 % thiazide/loop diuretic and 55 % aldosterone antagonist. OBP, available in 90 % at 11 months follow-up, was 163/93 mmHg (reduction of 22/9 mmHg). ABP, available in 70 % at 8.5 months follow-up, was 158/91 mmHg (fall of 12/7 mmHg). Mean drug changes post RDN were: 0.36 drugs added, 0.91 withdrawn. Dose changes appeared neutral. Quartile analysis by starting ABP showed mean reductions in systolic ABP after RDN of: 0.4; 6.5; 14.5 and 22.1 mmHg, respectively (p < 0.001 for trend). Use of aldosterone antagonist did not predict response (p > 0.2). CONCLUSION: In 253 patients treated with RDN, office BP fell by 22/9 mmHg. Ambulatory BP fell by 12/7 mmHg, though little response was seen in the lowermost quartile of starting blood pressure. Fall in BP was not explained by medication changes and aldosterone antagonist use did not affect response.


Assuntos
Pressão Sanguínea , Hipertensão/cirurgia , Rim/irrigação sanguínea , Artéria Renal/inervação , Simpatectomia/métodos , Sistema Nervoso Simpático/cirurgia , Idoso , Anti-Hipertensivos/uso terapêutico , Pressão Sanguínea/efeitos dos fármacos , Monitorização Ambulatorial da Pressão Arterial , Resistência a Medicamentos , Quimioterapia Combinada , Feminino , Humanos , Hipertensão/diagnóstico , Hipertensão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Antagonistas de Receptores de Mineralocorticoides , Visita a Consultório Médico , Sistema de Registros , Estudos Retrospectivos , Simpatectomia/efeitos adversos , Sistema Nervoso Simpático/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Reino Unido
11.
Int J Cardiovasc Imaging ; 32(2): 347-354, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26420491

RESUMO

Assessment of the left atrial appendage (LAA) for thrombus and anatomy is important prior to atrial fibrillation (AF) ablation and LAA exclusion. The use of cardiovascular CT (CCT) to detect LAA thrombus has been limited by the high incidence of pseudothrombus on single-pass studies. We evaluated the diagnostic accuracy of a two-phase protocol incorporating a limited low-dose delayed contrast-enhanced examination of the LAA, compared with a single-pass study for LAA morphological assessment, and transesophageal echocardiography (TEE) for the exclusion of thrombus. Consecutive patients (n = 122) undergoing left atrial interventions for AF were assessed. All had a two-phase CCT protocol (first-past scan plus a limited, 60-s delayed scan of the LAA) and TEE. Sensitivity, specificity, diagnostic accuracy, positive (PPV) and negative predictive values (NPV) were calculated for the detection of true thrombus on first-pass and delayed scans, using TEE as the gold standard. Overall, 20/122 (16.4 %) patients had filling defects on the first-pass study. All affected the full delineation of the LAA morphology; 17/20 (85 %) were confirmed as pseudo-filling defects. Three (15 %) were seen on late-pass and confirmed as true thrombi on TEE; a significant improvement in diagnostic performance relative to a single-pass scan (McNemar Chi-square 17, p < 0.001). The sensitivity, specificity, diagnostic accuracy, PPV and NPV was 100, 85.7, 86.1, 15.0 and 100 % respectively for first-pass scans, and 100 % for all parameters for the delayed scans. The median (range) additional radiation dose for the delayed scan was 0.4 (0.2-0.6) mSv. A low-dose delayed scan significantly improves the identification of true LAA anatomy and thrombus in patients undergoing LA intervention.


Assuntos
Apêndice Atrial/anatomia & histologia , Apêndice Atrial/diagnóstico por imagem , Trombose Coronária/diagnóstico por imagem , Cuidados Pré-Operatórios/métodos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
12.
Eur Radiol ; 26(5): 1493-502, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26253256

RESUMO

OBJECTIVES: We validate a novel CT coronary angiography (CCTA) coronary calcium scoring system. METHODS: Calcium was quantified on CCTA images using a new patient-specific attenuation threshold: mean + 2SD of intra-coronary contrast density (HU). Using 335 patient data sets a conversion factor (CF) for predicting CACS from CCTA scores (CCTAS) was derived and validated in a separate cohort (n = 168). Bland-Altman analysis and weighted kappa for MESA centiles and Agatston risk groupings were calculated. RESULTS: Multivariable linear regression yielded a CF: CACS = (1.185 × CCTAS) + (0.002 × CCTAS × attenuation threshold). When applied to CCTA data sets there was excellent correlation (r = 0.95; p < 0.0001) and agreement (mean difference -10.4 [95% limits of agreement -258.9 to 238.1]) with traditional calcium scores. Agreement was better for calcium scores below 500; however, MESA percentile agreement was better for high risk patients. Risk stratification was excellent (Agatston groups k = 0.88 and MESA centiles k = 0.91). Eliminating the dedicated CACS scan decreased patient radiation exposure by approximately one-third. CONCLUSION: CCTA calcium scores can accurately predict CACS using a simple, individualized, semiautomated approach reducing acquisition time and radiation exposure when evaluating patients for CAD. This method is not affected by the ROI location, imaging protocol, or tube voltage strengthening its clinical applicability. KEY POINTS: • Coronary calcium scores can be reliably determined on contrast-enhanced cardiac CT • This score can accurately risk stratify patients • Elimination of a dedicated calcium scan reduces patient radiation by a third.


Assuntos
Doença das Coronárias/diagnóstico por imagem , Calcificação Vascular/diagnóstico por imagem , Idoso , Angiografia Coronária/métodos , Vasos Coronários/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Humanos , Masculino , Tomografia Computadorizada Multidetectores/métodos , Variações Dependentes do Observador , Doses de Radiação , Reprodutibilidade dos Testes
13.
Int J Cardiovasc Imaging ; 31(7): 1435-46, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26068211

RESUMO

Transcatheter aortic valve implantation (TAVI) is an effective treatment option for patients with severe degenerative aortic valve stenosis who are high risk for conventional surgery. Computed tomography (CT) performed prior to TAVI can detect pathologies that could influence outcomes following the procedure, however the incidence, cost, and clinical impact of incidental findings has not previously been investigated. 279 patients underwent CT; 188 subsequently had TAVI and 91 were declined. Incidental findings were classified as clinically significant (requiring treatment), indeterminate (requiring further assessment), or clinically insignificant. The primary outcome measure was all-cause mortality up to 3 years. Costs incurred by additional investigations resultant to incidental findings were estimated using the UK Department of Health Payment Tariff. Incidental findings were common in both the TAVI and medical therapy cohorts (54.8 vs. 70.3%; P = 0.014). Subsequently, 45 extra investigations were recommended for the TAVI cohort, at an overall average cost of £32.69 per TAVI patient. In a univariate model, survival was significantly associated with the presence of a clinically significant or indeterminate finding (HR 1.61; P = 0.021). However, on multivariate analysis outcomes after TAVI were not influenced by any category of incidental finding. Incidental findings are common on CT scans performed prior to TAVI. However, the total cost involved in investigating these findings is low, and incidental findings do not independently identify patients with poorer outcomes after TAVI. The discovery of an incidental finding on CT should not necessarily influence or delay the decision to perform TAVI.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Cateterismo Cardíaco/métodos , Angiografia Coronária/economia , Custos de Cuidados de Saúde , Implante de Prótese de Valva Cardíaca/métodos , Achados Incidentais , Tomografia Computadorizada por Raios X/economia , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/economia , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/terapia , Causas de Morte , Distribuição de Qui-Quadrado , Angiografia Coronária/métodos , Feminino , Humanos , Estimativa de Kaplan-Meier , Londres , Masculino , Modelos Econômicos , Análise Multivariada , Valor Preditivo dos Testes , Modelos de Riscos Proporcionais , Fatores de Risco , Fatores de Tempo
16.
J Invasive Cardiol ; 27(1): E1-4, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25589704

RESUMO

The development of a large hematoma impairing visualization of the distal true lumen is a recognized complication of antegrade recanalization of chronic total occlusions, often forcing the operator to abort the procedure or switch to a retrograde approach. We describe a novel technique utilizing an over-the-wire balloon inflated in the proximal occluded vessel to block inflow and allow aspiration of the blood from the subintimal space. This decompressed the true lumen, restored distal visualization, and allowed successful reentry using a dedicated technology. Utilization of this novel technique may rescue antegrade recanalization attempts complicated by large subintimal hematomas.


Assuntos
Angioplastia Coronária com Balão/efeitos adversos , Oclusão Coronária/cirurgia , Descompressão Cirúrgica , Hematoma , Hemostasia Cirúrgica , Complicações Intraoperatórias/cirurgia , Complicações Pós-Operatórias/cirurgia , Idoso , Angioplastia Coronária com Balão/métodos , Ponte de Artéria Coronária/efeitos adversos , Oclusão Coronária/diagnóstico , Oclusão Coronária/etiologia , Oclusão Coronária/fisiopatologia , Descompressão Cirúrgica/instrumentação , Descompressão Cirúrgica/métodos , Hematoma/etiologia , Hematoma/cirurgia , Hemostasia Cirúrgica/instrumentação , Hemostasia Cirúrgica/métodos , Humanos , Masculino , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/fisiopatologia , Resultado do Tratamento
17.
EuroIntervention ; 11(3): 325-35, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24930135

RESUMO

AIMS: Challenging coronary anatomies including chronic total occlusions (CTO), extreme vessel tortuosity, diseased bypass grafts, and anomalous coronary arteries pose difficulties in coronary interventions. The GuideLiner is a monorail catheter originally developed to facilitate delivery of stents to target lesions in tortuous vessels. We conducted a study on the feasibility and safety of utilising this catheter in a wider array of complex coronary interventions. METHODS AND RESULTS: Consecutive patients undergoing coronary or peripheral interventions where a GuideLiner was used were recruited into this study. Patient demographics, lesion and vessel characteristics, procedural details and outcomes were prospectively entered into our database and analysed. From September 2009 to October 2011, 54 consecutive patients underwent coronary intervention in our institution using a GuideLiner; 21 out of 54 coronary applications were motivated by the need to increase support to cross CTOs, predominantly of the RCA. Anomalous or angulated take-off of the treatment vessels (31%), previously deployed proximal stents (15%), heavy proximal calcification (9%) and tortuosity (7%) accounted for the remaining reasons. One patient had successful renal denervation with the aid of a GuideLiner catheter. Procedural success was 98% in our series with no device-related periprocedural complications such as ostial dissection or myocardial necrosis. CONCLUSIONS: The use of a GuideLiner facilitates the approach to complex coronary interventions including chronic total occlusion and saphenous vein graft intervention by providing greater back-up support and easier engagement of coronary ostia.


Assuntos
Angioplastia Coronária com Balão , Cateteres Cardíacos , Doença da Artéria Coronariana/cirurgia , Idoso , Idoso de 80 Anos ou mais , Angioplastia Coronária com Balão/métodos , Cateterismo Cardíaco/métodos , Angiografia Coronária/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Stents , Resultado do Tratamento
18.
JACC Cardiovasc Interv ; 7(7): 741-50, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25060016

RESUMO

OBJECTIVES: The aim of this study was to compare the acute performance of the PLLA ABSORB bioresorbable vascular scaffold (BVS) (Abbott Vascular, Santa Clara, California) with second-generation metal drug-eluting stents (DES) in complex coronary artery lesions. BACKGROUND: Thick polymer-based BVS have different mechanical properties than thin second-generation DES. Data on the acute performance of BVS are limited to simple coronary lesions treated in trials with strict inclusion criteria. METHODS: Fifty complex coronary lesions (all type American College of Cardiology/American Heart Association B2-C) treated with a BVS undergoing a final optical coherence tomography (OCT) examination were compared with an equal number of matched lesions treated with second-generation DES. The following stent performance indexes were assessed with OCT: mean and minimal area, residual area stenosis (RAS), incomplete strut apposition (ISA), tissue prolapse, eccentricity index, symmetry index, strut fracture, and edge dissection. RESULTS: One hundred lesions from 73 patients were analyzed. A higher balloon diameter/reference vessel diameter ratio was used for predilation in the BVS group (p < 0.01). Most of the BVS and DES were post-dilated with short noncompliant (NC) balloons of similar diameter. OCT showed in the BVS group a higher tissue prolapse area (p = 0.08) and greater incidence of ISA at the proximal edge (p = 0.04) with no difference in the overall ISA. The RAS was 20.2% in the BVS group and 21.7% in the DES group (p = 0.32). There was no difference in the eccentricity index. The minimal and mean lumen areas were similar in the 2 groups. Two cases of strut fractures occurred after the BVS, whereas none was observed in the DES. CONCLUSIONS: Based on OCT, the BVS showed similar post-procedure area stenosis, minimal lumen area, and eccentricity index as second-generation DES. The different approach for lesion preparation and routine use of OCT guidance during BVS expansion may have contributed to these results.


Assuntos
Implantes Absorvíveis , Angioplastia Coronária com Balão/instrumentação , Doença da Artéria Coronariana/terapia , Vasos Coronários/patologia , Stents Farmacológicos , Metais , Stents , Tomografia de Coerência Óptica , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Estudos de Casos e Controles , Angiografia Coronária , Doença da Artéria Coronariana/patologia , Vasos Coronários/diagnóstico por imagem , Feminino , Humanos , Itália , Ácido Láctico , Londres , Masculino , Pessoa de Meia-Idade , Poliésteres , Polímeros , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Falha de Prótese , Fatores de Tempo , Resultado do Tratamento
19.
Glob Cardiol Sci Pract ; 2014(1): 78-87, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25054123

RESUMO

The introduction of transcatheter aortic valve implantation (TAVI) has resulted in a paradigm shift in the treatment of patients with severe aortic stenosis. Data from the recent U.S CoreValve Trial suggest, for the first time, that TAVI is associated with a significantly higher rate of survival at one year compared to surgical aortic valve replacement (SAVR) in the treatment of high-risk patients affected by severe aortic stenosis. The present review discusses this study and the current evidence about TAVI, for the treatment of severe aortic stenosis, from major trials and real world registries.

20.
J Cardiovasc Med (Hagerstown) ; 15(7): 543-53, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24922045

RESUMO

Optical coherence tomography (OCT) is a light-based technology that provides very high spatial resolution images. OCT has been initially employed as a research tool to investigate plaque morphology and stent strut coverage. The introduction of frequency domain OCT allowing fast image acquisition during a prolonged contrast injection via the guiding catheter has made OCT applicable for guidance of coronary interventions. In this manuscript, the various applications of OCT are reviewed, from assessment of plaque vulnerability and severity to characteristics of unstable lesions and thrombus burden to stent optimization and evaluation of late results.


Assuntos
Ponte de Artéria Coronária , Doença da Artéria Coronariana/diagnóstico , Vasos Coronários/patologia , Placa Aterosclerótica/diagnóstico , Tomografia de Coerência Óptica/métodos , Cateterismo Cardíaco , Doença da Artéria Coronariana/cirurgia , Vasos Coronários/diagnóstico por imagem , Humanos , Período Intraoperatório , Placa Aterosclerótica/cirurgia , Reprodutibilidade dos Testes , Ultrassonografia de Intervenção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA