Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Heart Rhythm ; 18(3): 360-365, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33181323

RESUMO

BACKGROUND: Electrical cardioversion is the first-line rhythm control therapy for symptomatic persistent atrial fibrillation (AF). Contemporary use of biphasic shock waveforms and anterior-posterior positioning of defibrillation electrodes have improved cardioversion efficacy; however, it remains unsuccessful in >10% of patients. OBJECTIVE: The purpose of this study was to assess the efficacy of applying active compression on defibrillation electrodes during AF cardioversion. METHODS: We performed a bicenter randomized study including patients referred for persistent AF cardioversion. Elective external cardioversion was performed by a standardized step-up protocol with increasing biphasic shock energy (50-100-150-200 J). Patients were randomly assigned to standard anterior-posterior defibrillation or to defibrillation with active compression applied over the anterior electrode. If sinus rhythm was not achieved at 200 J, a single crossover shock (200 J) was applied. Defibrillation threshold, total delivered energy, number of shocks, and success rate were compared between groups. RESULTS: We included 100 patients, 50 in each group. In the active compression group, defibrillation threshold was lower (103.1 ± 49.9 J vs 130.4 ± 47.7 J; P = .008), as well as total delivered energy (203 ± 173.3 J vs 309 ± 213.5 J; P = .0076) and number of shocks (2.2 ± 1.1 vs 2.9 ± 1.2; P = .0033), and cardioversion was more often successful (48 of 50 patients [96%] vs 42 of 50 patients [84%]; P = .0455) than that in the standard anterior-posterior group. Crossover from the compression group to the standard group was not successful (0 of 2 patients), whereas crossover from the standard group to the compression group was successful in 50% of patients (4 of 8). CONCLUSION: Active compression applied to the anterior defibrillation electrode is more effective for persistent AF cardioversion than standard anterior-posterior cardioversion, with lower defibrillation threshold and higher success rate.


Assuntos
Fibrilação Atrial/terapia , Desfibriladores , Cardioversão Elétrica/métodos , Idoso , Fibrilação Atrial/fisiopatologia , Estudos Cross-Over , Feminino , Seguimentos , Humanos , Masculino , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA