Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
1.
JACC Cardiovasc Interv ; 17(8): 1007-1016, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38573257

RESUMO

BACKGROUND: Data on valve reintervention after transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR) are limited. OBJECTIVES: The authors compared the 5-year incidence of valve reintervention after self-expanding CoreValve/Evolut TAVR vs SAVR. METHODS: Pooled data from CoreValve and Evolut R/PRO (Medtronic) randomized trials and single-arm studies encompassed 5,925 TAVR (4,478 CoreValve and 1,447 Evolut R/PRO) and 1,832 SAVR patients. Reinterventions were categorized by indication, timing, and treatment. The cumulative incidence of reintervention was compared between TAVR vs SAVR, Evolut vs CoreValve, and Evolut vs SAVR. RESULTS: There were 99 reinterventions (80 TAVR and 19 SAVR). The cumulative incidence of reintervention through 5 years was higher with TAVR vs SAVR (2.2% vs 1.5%; P = 0.017), with differences observed early (≤1 year; adjusted subdistribution HR: 3.50; 95% CI: 1.53-8.02) but not from >1 to 5 years (adjusted subdistribution HR: 1.05; 95% CI: 0.48-2.28). The most common reason for reintervention was paravalvular regurgitation after TAVR and endocarditis after SAVR. Evolut had a significantly lower incidence of reintervention than CoreValve (0.9% vs 1.6%; P = 0.006) at 5 years with differences observed early (adjusted subdistribution HR: 0.30; 95% CI: 0.12-0.73) but not from >1 to 5 years (adjusted subdistribution HR: 0.61; 95% CI: 0.21-1.74). The 5-year incidence of reintervention was similar for Evolut vs SAVR (0.9% vs 1.5%; P = 0.41). CONCLUSIONS: A low incidence of reintervention was observed for CoreValve/Evolut R/PRO and SAVR through 5 years. Reintervention occurred most often at ≤1 year for TAVR and >1 year for SAVR. Most early reinterventions were with the first-generation CoreValve and managed percutaneously. Reinterventions were more common following CoreValve TAVR compared with Evolut TAVR or SAVR.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Complicações Pós-Operatórias , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Complicações Pós-Operatórias/cirurgia , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento , Incidência , Retratamento
2.
J Am Coll Cardiol ; 83(14): 1257-1272, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38471643

RESUMO

BACKGROUND: Left ventricular outflow tract (LVOT) obstruction is a source of morbidity in hypertrophic cardiomyopathy (HCM) and a life-threatening complication of transcatheter mitral valve replacement (TMVR) and transcatheter aortic valve replacement (TAVR). Available surgical and transcatheter approaches are limited by high surgical risk, unsuitable septal perforators, and heart block requiring permanent pacemakers. OBJECTIVES: The authors report the initial experience of a novel transcatheter electrosurgical procedure developed to mimic surgical myotomy. METHODS: We used septal scoring along midline endocardium (SESAME) to treat patients, on a compassionate basis, with symptomatic LVOT obstruction or to create space to facilitate TMVR or TAVR. RESULTS: In this single-center retrospective study between 2021 and 2023, 76 patients underwent SESAME. In total, 11 (14%) had classic HCM, and the remainder underwent SESAME to facilitate TMVR or TAVR. All had technically successful SESAME myocardial laceration. Measures to predict post-TMVR LVOT significantly improved (neo-LVOT 42 mm2 [Q1-Q3: 7-117 mm2] to 170 mm2 [Q1-Q3: 95-265 mm2]; P < 0.001; skirt-neo-LVOT 169 mm2 [Q1-Q3: 153-193 mm2] to 214 mm2 [Q1-Q3: 180-262 mm2]; P < 0.001). Among patients with HCM, SESAME significantly decreased invasive LVOT gradients (resting: 54 mm Hg [Q1-Q3: 40-70 mm Hg] to 29 mm Hg [Q1-Q3: 12-36 mm Hg]; P = 0.023; provoked 146 mm Hg [Q1-Q3: 100-180 mm Hg] to 85 mm Hg [Q1-Q3: 40-120 mm Hg]; P = 0.076). A total of 74 (97.4%) survived the procedure. Five experienced 3 of 76 (3.9%) iatrogenic ventricular septal defects that did not require repair and 3 of 76 (3.9%) ventricular free wall perforations. Neither occurred in patients treated for HCM. Permanent pacemakers were required in 4 of 76 (5.3%), including 2 after concomitant TAVR. Lacerations were stable and did not propagate after SESAME (remaining septum: 5.9 ± 3.3 mm to 6.1 ± 3.2 mm; P = 0.8). CONCLUSIONS: With further experience, SESAME may benefit patients requiring septal reduction therapy for obstructive hypertrophic cardiomyopathy as well as those with LVOT obstruction after heart valve replacement, and/or can help facilitate transcatheter valve implantation.


Assuntos
Cardiomiopatia Hipertrófica , Implante de Prótese de Valva Cardíaca , Miotomia , Obstrução da Via de Saída Ventricular Esquerda , Obstrução do Fluxo Ventricular Externo , Humanos , Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Estudos Retrospectivos , Cateterismo Cardíaco/métodos , Obstrução do Fluxo Ventricular Externo/etiologia , Obstrução do Fluxo Ventricular Externo/cirurgia , Resultado do Tratamento , Cardiomiopatia Hipertrófica/complicações , Miotomia/efeitos adversos
4.
J Cardiovasc Electrophysiol ; 34(11): 2225-2232, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37702135

RESUMO

INTRODUCTION: The need for pacemaker is a common complication after transcatheter aortic valve replacement (TAVR). We previously described the Emory Risk Score (ERS) to predict the need for new pacemaker implant (PPM) after TAVR. Metrics included in the score are a history of syncope, pre-existing RBBB, QRS duration ≥140 ms, and prosthesis oversizing ≥16%. To prospectively validate the previously described risk score. METHODS: We prospectively evaluated all patients without pre-existing pacemakers, ICD, or pre-existing indications for pacing undergoing TAVR with the Edwards SAPIEN 3 prosthesis at our institution from March 2019 to December 2020 (n = 661). Patients were scored prospectively; however, results were blinded from clinical decision-making. The primary endpoint was PPM at 30 days after TAVR. Performance of the ERS was evaluated using logistic regression, a calibration curve to prior performance, and receiver operating characteristic (ROC) analysis. RESULTS: A total of 48 patients (7.3%) had PPM after TAVR. A higher ERS predicted an increased likelihood of PPM (OR 2.61, 95% CI: 2.05-3.25 per point, p < 0.001). There was good correlation between observed and expected values on the calibration curve (slope = 1.04, calibration at large = 0.001). The area under the ROC curve was 0.81 (95% CI [0.74-0.88], p < 0.001). CONCLUSIONS: The ERS prospectively predicted the need for PPM in a serial, real-world cohort of patients undergoing TAVR with a balloon-expandable prosthesis, confirming findings previously described in retrospective cohorts. Notably, the prospective performance of the score was comparable with that of the initial cohorts. The risk score could serve as a framework for preprocedural risk stratification for PPM after TAVR.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Estudos Retrospectivos , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Fatores de Risco , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
6.
EuroIntervention ; 19(4): e330-e339, 2023 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-37067193

RESUMO

BACKGROUND: Transcatheter aortic valve implantation in an existing transcatheter valve (redo-TAVI) pins the index valve leaflets in the open position (neoskirt), which can cause coronary flow compromise and limit access. Whether anatomy may preclude redo-TAVI in self-expanding Evolut valves is unknown. AIMS: We aimed to evaluate the anatomical feasibility of redo-TAVI by simulating implantation of a balloon-expandable SAPIEN 3 (S3) within an Evolut or an Evolut within an Evolut. METHODS: A total of 204 post-TAVI computed tomography (CT) scans from the Evolut Low Risk CT substudy were analysed. Five redo-TAVI positions were evaluated: S3-in-Evolut inflow-to-inflow, S3 outflow at Evolut nodes 4, 5, and 6, and Evolut-in-Evolut inflow-to-inflow. Univariable modelling identified pre-TAVI clinical characteristics, CT anatomical parameters, and procedural variables associated with coronary flow compromise using the neoskirt height and post-TAVI aortic root dimensions. RESULTS: The risk of coronary flow compromise was lowest when the S3 outflow was at Evolut node 4 (20%) and highest when at Evolut node 6 (75%). The highest likelihood of preserving coronary accessibility occurred with the S3 outflow at Evolut node 4. Female sex and higher body mass index were associated with a higher risk of coronary flow compromise, as were a smaller annulus diameter, lower sinus of Valsalva height and width, shorter coronary height, smaller sinotubular junction diameter, and shallower Evolut implant depth. CONCLUSIONS: The feasibility of redo-TAVI after Evolut failure is multifactorial and relates to the native annular anatomy, as well as the implantation depth of the index and second bioprostheses. Placement of an S3 at a lower Evolut position may reduce the risk of coronary flow compromise while preserving coronary access. CLINICALTRIALS: gov: NCT02701283.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Feminino , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estudos de Viabilidade , Desenho de Prótese , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
7.
J Thorac Cardiovasc Surg ; 166(4): e130-e141, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37086238

RESUMO

BACKGROUND: Leaflet thrombosis after surgical aortic valve replacement (SAVR) and transcatheter aortic valve replacement (TAVR) may be caused by blood flow stagnation in the native and neosinus regions. To date, aortic leaflet laceration has been used to mitigate coronary obstruction following TAVR; however, its influence on the fluid mechanics of the native and neosinus regions is poorly understood. This in vitro study compared the flow velocities and flow patterns in the setting of SAVR vs TAVR with and without aortic leaflet lacerations. METHODS: Two valves, (23-mm Perimount and 26-mm SAPIEN 3; Edwards Lifesciences) were studied in a validated mock flow loop under physiologic conditions. Neosinus and native sinus fluid mechanics were quantified using particle image velocimetry in the left and noncoronary cusp, with an increasing number of aortic leaflets lacerated or removed. RESULTS: Across all conditions, SAVR had the highest average sinus and neosinus velocities, and this value was used as a reference to compare against the TAVR conditions. With an increasing number of leaflets lacerated or removed with TAVR, the average sinus and neosinus velocities increased from 25% to 70% of SAVR flow (100%). Diastolic velocities were substantially augmented by leaflet laceration. Also, the shorter frame of the SAVR led to higher flow velocities compared with the longer frame of the TAVR, even after complete leaflet removal. CONCLUSIONS: Leaflet laceration augmented TAVR native and neosinus flow fields, approaching that of SAVR. These findings may have potential clinical implications for the use of single or multiple leaflet lacerations to reduce leaflet thrombosis and thus potentially improve TAVR durability.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Lacerações , Trombose , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Lacerações/complicações , Lacerações/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Trombose/etiologia , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento
8.
JACC Cardiovasc Interv ; 16(4): 415-425, 2023 02 27.
Artigo em Inglês | MEDLINE | ID: mdl-36858660

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR)-related coronary artery obstruction prediction remains unsatisfactory despite high mortality and novel preventive therapies. OBJECTIVES: This study sought to develop a predictive model for TAVR-related coronary obstruction in native aortic stenosis. METHODS: Preprocedure computed tomography and fluoroscopy images of patients in whom TAVR caused coronary artery obstruction were collected. Central laboratories made measurements, which were compared with unobstructed patients from a single-center database. A multivariate model was developed and validated against a 1:1 propensity-matched subselection of the unobstructed cohort. RESULTS: Sixty patients with angiographically confirmed coronary obstruction and 1,381 without obstruction were included. In-hospital death was higher in the obstruction cohort (26.7% vs 0.7%; P < 0.001). Annular area and perimeter, coronary height, sinus width, and sinotubular junction height and width were all significantly smaller in the obstructed cohort. Obstruction was most common on the left side (78.3%) and at the level of the coronary artery ostium (92.1%). Coronary artery height and sinus width, but not annulus area, were significant risk factors for obstruction by logistic regression but performed poorly in predicting obstruction. The new multivariate model (coronary obstruction IF cusp height > coronary height, AND virtual valve-to-coronary distance ≤4 mm OR culprit leaflet calcium volume >600 mm3) performed well, with an area under the curve of 0.93 (sensitivity = 0.93, specificity = 0.84) for the left coronary artery and 0.94 (sensitivity = 0.92, specificity = 0.96) for the right. CONCLUSIONS: A novel computed tomography-based multivariate prediction model that can be implemented routinely in real-world practice predicted coronary artery obstruction from TAVR in native aortic stenosis.


Assuntos
Estenose da Valva Aórtica , Oclusão Coronária , Substituição da Valva Aórtica Transcateter , Humanos , Mortalidade Hospitalar , Resultado do Tratamento , Coração
9.
Cardiovasc Revasc Med ; 53S: S176-S179, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-35879191

RESUMO

A cardiogenic shock patient with a history of a surgical mitral valve replacement presented to the hospital with critical mitral stenosis with thickening of prosthetic valve leaflets and thrombus in left atrial appendage. We considered TMVR inside of the degenerated bioprosthetic valve. However, there were two concerns during TMVR based on multimodality imaging assessment: 1) LVOT obstruction due to the surgical bioprosthetic leaflet, 2) stroke due to left atrial appendage thrombus. We performed TMVR with LAMPOON (laceration of the anterior leaflet of the surgical valve to prevent left ventricular outflow tract obstruction) for the bioprosthesis using cerebral protection. While the LAMPOON procedure has developed to prevent LVOT obstruction by the native anterior mitral leaflet during transcatheter mitral valve-in-ring or valve-in-mitral annular calcification, this is the first case that illustrates its use for mitral valve-in-valve replacement.


Assuntos
Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Trombose , Obstrução do Fluxo Ventricular Externo , Humanos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Fatores de Risco , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Resultado do Tratamento
11.
JACC Cardiovasc Interv ; 15(15): 1543-1554, 2022 08 08.
Artigo em Inglês | MEDLINE | ID: mdl-35926921

RESUMO

BACKGROUND: As transcatheter aortic valve (TAV) replacement is increasingly used in patients with longer life expectancy, a sizable proportion will require redo TAV replacement (TAVR). The unique configuration of balloon-expandable TAV (bTAV) vs a self-expanding TAV (sTAV) potentially affects TAV-in-TAV outcome. OBJECTIVES: The purpose of this study was to better inform prosthesis selection, TAV-in-TAV outcomes were assessed according to the type of initial and subsequent TAV. METHODS: Patients from the Redo-TAVR registry were analyzed using propensity weighting according to their initial valve type (bTAV [n = 115] vs sTAV [n = 106]) and subsequent valve type (bTAV [n = 130] vs sTAV [n = 91]). RESULTS: Patients with failed bTAVs presented later (vs sTAV) (4.9 ± 2.1 years vs 3.7 ± 2.3 years; P < 0.001), with smaller effective orifice area (1.0 ± 0.7 cm2 vs 1.3 ± 0.8 cm2; P = 0.018) and less frequent dominant regurgitation (16.2% vs 47.3%; P < 0.001). Mortality at 30 days was 2.3% (TAV-in-bTAV) vs 0% (TAV-in-sTAV) (P = 0.499) and 1.7% (bTAV-in-TAV) vs 1.0% (sTAV-in-TAV) (P = 0.612); procedural safety was 72.6% (TAV-in-bTAV) vs 71.2% (TAV-in-sTAV) (P = 0.817) and 73.2% (bTAV-in-TAV) vs 76.5% (sTAV-in-TAV) (P = 0.590). Device success was similar according to initial valve type but higher with subsequent sTAV vs bTAV (77.2% vs 64.3%; P = 0.045), primarily because of lower residual gradients (10.3 mm Hg [8.9-11.7 mm Hg] vs 15.2 mm Hg [13.2-17.1 mm Hg]; P < 0.001). Residual regurgitation (moderate or greater) was similar after bTAV-in-TAV and sTAV-in-TAV (5.7%) and nominally higher after TAV-in-bTAV (9.1%) vs TAV-in-sTAV (4.4%) (P = 0.176). CONCLUSIONS: In selected patients, no association was observed between TAV type and redo TAVR safety or mortality, yet subsequent sTAV was associated with higher device success because of lower redo gradients. These findings are preliminary, and more data are needed to guide valve choice for redo TAVR.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Sistema de Registros , Fatores de Risco , Resultado do Tratamento
13.
JACC Cardiovasc Interv ; 15(12): 1249-1263, 2022 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-35738745

RESUMO

BACKGROUND: Transcatheter mitral valve repair is beneficial in patients with mitral regurgitation (MR), left ventricular dysfunction, and persistent symptoms despite maximally tolerated medical therapy. OBJECTIVES: The aim of this study was to evaluate the safety and feasibility of transcatheter mitral cerclage ventriculoplasty in patients with MR and either heart failure with reduced ejection fraction or preserved ejection fraction and in subjects with prior edge-to-edge repair but persistent or recurrent symptomatic MR. METHODS: The National Heart, Lung, and Blood Institute Division of Intramural Research Transcatheter Mitral Cerclage Ventriculoplasty Early Feasibility Study (NCT03929913) was an investigator-initiated prospective multicenter study. The primary endpoint was technical success measured at exit from the catheterization laboratory. Follow-up included heart failure quality-of-life assessments and serial imaging with echocardiography and cardiac computed tomography. RESULTS: Nineteen subjects consented and underwent cerclage, 63% with heart failure with reduced ejection fraction and 37% with heart failure with preserved ejection fraction, with ischemic cardiomyopathy in 26% and nonischemic cardiomyopathy in 74%. There were no procedural deaths, strokes, or transient ischemic attacks or other major cardiovascular adverse events. The primary endpoint was met in 17 subjects. Cerclage induced sustained reductions in mitral regurgitant volume (-41%) and effective orifice area (-33%) after a median of 337 days. Cerclage resulted in improvements in 6-minute walking distance (+78 m) and Kansas City Cardiomyopathy Questionnaire Overall Summary Score (+22 points) at 30 days that were maintained after a median of 265 days. New complete heart block developed in 6 of 17 subjects. Three deaths occurred on postprocedural days 79, 159, and 756, unrelated to cerclage. CONCLUSIONS: Transcatheter mitral cerclage ventriculoplasty resulted in significant and sustained improvements in mitral regurgitation and in heart failure quality-of-life assessments.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Disfunção Ventricular Esquerda , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/terapia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Estudos Prospectivos , Resultado do Tratamento
15.
JACC Cardiovasc Interv ; 15(9): 965-975, 2022 05 09.
Artigo em Inglês | MEDLINE | ID: mdl-35512920

RESUMO

OBJECTIVES: The aim of this study was to compare transcaval and transaxillary artery access for transcatheter aortic valve replacement (TAVR) at experienced medical centers in contemporary practice. BACKGROUND: There are no systematic comparisons of transcaval and transaxillary TAVR access routes. METHODS: Eight experienced centers contributed local data collected for the STS/ACC TVT Registry (Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry) between 2017 and 2020. Outcomes after transcaval and axillary/subclavian (transaxillary) access were adjusted for baseline imbalances using doubly robust (inverse propensity weighting plus regression) estimation and compared. RESULTS: Transcaval access was used in 238 procedures and transaxillary access in 106; for comparison, transfemoral access was used in 7,132 procedures. Risk profiles were higher among patients selected for nonfemoral access but similar among patients requiring transcaval and transaxillary access. Stroke and transient ischemic attack were 5-fold less common after transcaval than transaxillary access (2.5% vs 13.2%; OR: 0.20; 95% CI: 0.06-0.72; P = 0.014) compared with transfemoral access (1.7%). Major and life-threatening bleeding (Valve Academic Research Consortium 3 ≥ type 2) were comparable (10.0% vs 13.2%; OR: 0.66; 95% CI: 0.26-1.66; P = 0.38) compared with transfemoral access (3.5%), as was blood transfusion (19.3% vs 21.7%; OR: 1.07; 95% CI: 0.49-2.33; P = 0.87) compared with transfemoral access (7.1%). Vascular complications, intensive care unit and hospital length of stay, and survival were similar between transcaval and transaxillary access. More patients were discharged directly home and without stroke or transient ischemic attack after transcaval than transaxillary access (87.8% vs 62.3%; OR: 5.19; 95% CI: 2.45-11.0; P < 0.001) compared with transfemoral access (90.3%). CONCLUSIONS: Patients undergoing transcaval TAVR had lower rates of stroke and similar bleeding compared with transaxillary access in a contemporary experience from 8 US centers. Both approaches had more complications than transfemoral access. Transcaval TAVR access may offer an attractive option.


Assuntos
Estenose da Valva Aórtica , Ataque Isquêmico Transitório , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Sistema de Registros , Fatores de Risco , Resultado do Tratamento , Estados Unidos
16.
Am J Cardiol ; 172: 90-97, 2022 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-35387738

RESUMO

Scarce data exist on mitral valve (MV) infective endocarditis (IE) after transcatheter aortic valve implantation (TAVI). This multicenter study included a total of 579 patients with a diagnosis of definite IE after TAVI from the IE after TAVI International Registry and aimed to evaluate the incidence, characteristics, management, and outcomes of MV-IE after TAVI. A total of 86 patients (14.9%) had MV-IE. These patients were compared with 284 patients (49.1%) with involvement of the transcatheter heart valve (THV) only. Two factors were found to be associated with MV-IE: the use of self-expanding valves (adjusted odds ratio 2.49, 95% confidence interval [CI] 1.23 to 5.07, p = 0.012), and the presence of an aortic regurgitation ≥2 at discharge (adjusted odds ratio 3.33; 95% CI 1.43 to 7.73, p <0.01). There were no differences in IE timing and causative microorganisms between groups, but surgical management was significantly lower in patients with MV-IE (6.0%, vs 21.6% in patients with THV-IE, p = 0.001). All-cause mortality rates at 2-year follow-up were high and similar between patients with MV-IE (51.4%, 95% CI 39.8 to 64.1) and patients with THV-IE (51.5%, 95% CI 45.4 to 58.0) (log-rank p = 0.295). The factors independently associated with increased mortality risk in patients with MV-IE were the occurrence of heart failure (adjusted p <0.001) and septic shock (adjusted p <0.01) during the index hospitalization. One of 6 IE episodes after TAVI is localized on the MV. The implantation of a self-expanding THV and the presence of an aortic regurgitation ≥2 at discharge were associated with MV-IE. Patients with MV-IE were rarely operated on and had a poor prognosis at 2-year follow-up.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Endocardite , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/complicações , Insuficiência da Valva Aórtica/epidemiologia , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/cirurgia , Catéteres/efeitos adversos , Endocardite/epidemiologia , Endocardite/etiologia , Próteses Valvulares Cardíacas/efeitos adversos , Humanos , Valva Mitral/cirurgia , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
17.
J Am Coll Cardiol ; 79(8): 772-785, 2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-35210032

RESUMO

BACKGROUND: The optimal treatment of patients developing infective endocarditis (IE) after transcatheter aortic valve implantation (TAVI) is uncertain. OBJECTIVES: The goal of this study was to investigate the clinical characteristics and outcomes of patients with TAVI-IE treated with cardiac surgery and antibiotics (IE-CS) compared with patients treated with antibiotics alone (IE-AB). METHODS: Crude and inverse probability of treatment weighting analyses were applied for the treatment effect of cardiac surgery vs medical therapy on 1-year all-cause mortality in patients with definite TAVI-IE. The study used data from the Infectious Endocarditis after TAVI International Registry. RESULTS: Among 584 patients, 111 patients (19%) were treated with IE-CS and 473 patients (81%) with IE-AB. Compared with IE-AB, IE-CS was not associated with a lower in-hospital mortality (HRunadj: 0.85; 95% CI: 0.58-1.25) and 1-year all-cause mortality (HRunadj: 0.88; 95% CI: 0.64-1.22) in the crude cohort. After adjusting for selection and immortal time bias, IE-CS compared with IE-AB was also not associated with lower mortality rates for in-hospital mortality (HRadj: 0.92; 95% CI: 0.80-1.05) and 1-year all-cause mortality (HRadj: 0.95; 95% CI: 0.84-1.07). Results remained similar when patients with and without TAVI prosthesis involvement were analyzed separately. Predictors for in-hospital and 1-year all-cause mortality included logistic EuroSCORE I, Staphylococcus aureus, acute renal failure, persistent bacteremia, and septic shock. CONCLUSIONS: In this registry, the majority of patients with TAVI-IE were treated with antibiotics alone. Cardiac surgery was not associated with an improved all-cause in-hospital or 1-year mortality. The high mortality of patients with TAVI-IE was strongly linked to patients' characteristics, pathogen, and IE-related complications.


Assuntos
Endocardite Bacteriana/tratamento farmacológico , Endocardite Bacteriana/cirurgia , Infecções Relacionadas à Prótese/tratamento farmacológico , Infecções Relacionadas à Prótese/cirurgia , Infecções Estafilocócicas/tratamento farmacológico , Infecções Estafilocócicas/cirurgia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Antibacterianos/uso terapêutico , Procedimentos Cirúrgicos Cardíacos , Terapia Combinada , Endocardite Bacteriana/etiologia , Feminino , Humanos , Masculino , Infecções Relacionadas à Prótese/etiologia , Infecções Estafilocócicas/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos
18.
Cardiovasc Revasc Med ; 40S: 218-221, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34952823

RESUMO

Saphenous vein graft (SVG) aneurysms are rare but can be associated with significant morbidity and mortality. This case illustrates a percutaneous approach for the management of SVG aneurysm with a fistulous connection to the right atrium.


Assuntos
Aneurisma , Veia Safena , Aneurisma/diagnóstico por imagem , Aneurisma/etiologia , Aneurisma/cirurgia , Ponte de Artéria Coronária/efeitos adversos , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Humanos , Veia Safena/diagnóstico por imagem , Veia Safena/transplante
19.
Clin Infect Dis ; 75(4): 638-646, 2022 09 10.
Artigo em Inglês | MEDLINE | ID: mdl-34894124

RESUMO

BACKGROUND: Infective endocarditis (IE) following transcatheter aortic valve replacement (TAVR) has been associated with a dismal prognosis. However, scarce data exist on IE perivalvular extension (PEE) in such patients. METHODS: This multicenter study included 579 patients who had the diagnosis of definite IE at a median of 171 (53-421) days following TAVR. PEE was defined as the presence of an intracardiac abscess, pseudoaneurysm, or fistula. RESULTS: A total of 105 patients (18.1%) were diagnosed with PEE (perivalvular abscess, pseudoaneurysm, fistula, or a combination in 87, 7, 7, and 4 patients, respectively). A history of chronic kidney disease (adjusted odds ratio [ORadj], 2.08; 95% confidence interval [CI]: 1.27-3.41; P = .003) and IE secondary to coagulase-negative staphylococci (ORadj, 2.71; 95% CI: 1.57-4.69; P < .001) were associated with an increased risk of PEE. Surgery was performed at index IE episode in 34 patients (32.4%) with PEE (vs 15.2% in patients without PEE, P < .001). In-hospital and 2-year mortality rates among PEE-IE patients were 36.5% and 69.4%, respectively. Factors independently associated with an increased mortality were the occurrence of other complications (stroke post-TAVR, acute renal failure, septic shock) and the lack of surgery at index IE hospitalization (padj < 0.05 for all). CONCLUSIONS: PEE occurred in about one-fifth of IE post-TAVR patients, with the presence of coagulase-negative staphylococci and chronic kidney disease determining an increased risk. Patients with PEE-IE exhibited high early and late mortality rates, and surgery during IE hospitalization seemed to be associated with better outcomes.


Assuntos
Falso Aneurisma , Endocardite Bacteriana , Endocardite , Insuficiência Renal Crônica , Substituição da Valva Aórtica Transcateter , Abscesso , Falso Aneurisma/complicações , Falso Aneurisma/cirurgia , Coagulase , Endocardite/epidemiologia , Endocardite/etiologia , Endocardite/cirurgia , Endocardite Bacteriana/epidemiologia , Endocardite Bacteriana/etiologia , Endocardite Bacteriana/cirurgia , Humanos , Insuficiência Renal Crônica/complicações , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos
20.
Can J Cardiol ; 38(1): 102-112, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34688853

RESUMO

BACKGROUND: Staphylococcus aureus (SA) has been extensively studied as causative microorganism of surgical prosthetic-valve infective endocarditis (IE). However, scarce evidence exists on SA IE after transcatheter aortic valve replacement (TAVR). METHODS: Data were obtained from the Infectious Endocarditis After TAVR International Registry, including patients with definite IE after TAVR from 59 centres in 11 countries. Patients were divided into 2 groups according to microbiologic etiology: non-SA IE vs SA IE. RESULTS: SA IE was identified in 141 patients out of 573 (24.6%), methicillin-sensitive SA in most cases (115/141, 81.6%). Self-expanding valves were more common than balloon-expandable valves in patients presenting with early SA IE. Major bleeding and sepsis complicating TAVR, neurologic symptoms or systemic embolism at admission, and IE with cardiac device involvement (other than the TAVR prosthesis) were associated with SA IE (P < 0.05 for all). Among patients with IE after TAVR, the likelihood of SA IE increased from 19% in the absence of those risk factors to 84.6% if ≥ 3 risk factors were present. In-hospital (47.8% vs 26.9%; P < 0.001) and 2-year (71.5% vs 49.6%; P < 0.001) mortality rates were higher among patients with SA IE vs non-SA IE. Surgery at the time of index SA IE episode was associated with lower mortality at follow-up compared with medical therapy alone (adjusted hazard ratio 0.46, 95% CI 0.22-0.96; P = 0.038). CONCLUSIONS: SA IE represented approximately 25% of IE cases after TAVR and was associated with very high in-hospital and late mortality. The presence of some features determined a higher likelihood of SA IE and could help to orientate early antibiotic regimen selection. Surgery at index SA IE was associated with improved outcomes, and its role should be evaluated in future studies.


Assuntos
Endocardite Bacteriana/epidemiologia , Próteses Valvulares Cardíacas/efeitos adversos , Infecções Relacionadas à Prótese/epidemiologia , Sistema de Registros , Infecções Estafilocócicas/epidemiologia , Staphylococcus aureus/isolamento & purificação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Endocardite Bacteriana/microbiologia , Feminino , Seguimentos , Saúde Global , Próteses Valvulares Cardíacas/microbiologia , Mortalidade Hospitalar/tendências , Humanos , Incidência , Masculino , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/microbiologia , Estudos Retrospectivos , Fatores de Risco , Infecções Estafilocócicas/diagnóstico , Infecções Estafilocócicas/microbiologia , Taxa de Sobrevida/tendências , Substituição da Valva Aórtica Transcateter/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA