Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Emerg Infect Dis ; 30(3): 530-538, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38407144

RESUMO

Persons living in long-term care facilities (LTCFs) were disproportionately affected by COVID-19. We used wastewater surveillance to detect SARS-CoV-2 infection in this setting by collecting and testing 24-hour composite wastewater samples 2-4 times weekly at 6 LTCFs in Kentucky, USA, during March 2021-February 2022. The LTCFs routinely tested staff and symptomatic and exposed residents for SARS-CoV-2 using rapid antigen tests. Of 780 wastewater samples analyzed, 22% (n = 173) had detectable SARS-CoV-2 RNA. The LTCFs reported 161 positive (of 16,905) SARS-CoV-2 clinical tests. The wastewater SARS-CoV-2 signal showed variable correlation with clinical test data; we observed the strongest correlations in the LTCFs with the most positive clinical tests (n = 45 and n = 58). Wastewater surveillance was 48% sensitive and 80% specific in identifying SARS-CoV-2 infections found on clinical testing, which was limited by frequency, coverage, and rapid antigen test performance.


Assuntos
COVID-19 , Águas Residuárias , Humanos , Kentucky/epidemiologia , Vigilância Epidemiológica Baseada em Águas Residuárias , Assistência de Longa Duração , RNA Viral , COVID-19/diagnóstico , COVID-19/epidemiologia , SARS-CoV-2
2.
JMIR Public Health Surveill ; 9: e44657, 2023 08 29.
Artigo em Inglês | MEDLINE | ID: mdl-37643001

RESUMO

BACKGROUND: Wastewater surveillance provided early indication of COVID-19 in US municipalities. Residents of long-term care facilities (LTCFs) experienced disproportionate morbidity and mortality early in the COVID-19 pandemic. We implemented LTCF building-level wastewater surveillance for SARS-CoV-2 at 6 facilities in Kentucky to provide early warning of SARS-CoV-2 in populations considered vulnerable. OBJECTIVE: This study aims to evaluate the performance of wastewater surveillance for SARS-CoV-2 at LTCFs in Kentucky. METHODS: We conducted a mixed methods evaluation of wastewater surveillance following Centers for Disease Control and Prevention (CDC) guidelines for evaluating public health surveillance systems. Evaluation steps in the CDC guidelines were engaging stakeholders, describing the surveillance system, focusing the evaluation design, gathering credible evidence, and generating conclusions and recommendations. We purposively recruited stakeholders for semistructured interviews and undertook thematic content analysis of interview data. We integrated wastewater, clinical testing, and process data to characterize or calculate 7 surveillance system performance attributes (simplicity, flexibility, data quality, sensitivity and positive predictive value [PPV], timeliness, representativeness, and stability). RESULTS: We conducted 8 stakeholder interviews. The surveillance system collected wastewater samples (N=811) 2 to 4 times weekly at 6 LTCFs in Kentucky from March 2021 to February 2022. Synthesis of credible evidence indicated variable surveillance performance. Regarding simplicity, surveillance implementation required moderate human resource and technical capacity. Regarding flexibility, the system efficiently adjusted surveillance frequency and demonstrated the ability to detect additional pathogens of interest. Regarding data quality, software identified errors in wastewater sample metadata entry (110/3120, 3.53% of fields), technicians identified polymerase chain reaction data issues (140/7734, 1.81% of reactions), and staff entered all data corrections into a log. Regarding sensitivity and PPV, using routine LTCF SARS-CoV-2 clinical testing results as the gold standard, a wastewater SARS-CoV-2 signal of >0 RNA copies/mL was 30.6% (95% CI 24.4%-36.8%) sensitive and 79.7% (95% CI 76.4%-82.9%) specific for a positive clinical test at the LTCF. The PPV of the wastewater signal was 34.8% (95% CI 27.9%-41.7%) at >0 RNA copies/mL and increased to 75% (95% CI 60%-90%) at >250 copies/mL. Regarding timeliness, stakeholders received surveillance data 24 to 72 hours after sample collection, with delayed reporting because of the lack of weekend laboratory staff. Regarding representativeness, stakeholders identified challenges delineating the population contributing to LTCF wastewater because of visitors, unknown staff toileting habits, and the use of adult briefs by some residents preventing their waste from entering the sewer system. Regarding stability, the reoccurring cost to conduct 1 day of wastewater surveillance at 1 facility was approximately US $144.50, which included transportation, labor, and materials expenses. CONCLUSIONS: The LTCF wastewater surveillance system demonstrated mixed performance per CDC criteria. Stakeholders found surveillance feasible and expressed optimism regarding its potential while also recognizing challenges in interpreting and acting on surveillance data.


Assuntos
COVID-19 , Águas Residuárias , Estados Unidos , Adulto , Humanos , SARS-CoV-2 , Assistência de Longa Duração , Pandemias/prevenção & controle , Vigilância Epidemiológica Baseada em Águas Residuárias , COVID-19/epidemiologia
3.
Sci Total Environ ; 878: 162992, 2023 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-36948314

RESUMO

Wastewater-based Epidemiology (WBE) has contributed to surveillance of SARS-CoV-2 in communities across the world. Both symptomatic and asymptomatic patients with COVID-19 can shed the virus through the gastrointestinal tract, enabling the quantification of the virus in stool and ultimately in wastewater (WW). Unfortunately, instability of SARS-CoV-2 RNA in wastewater limits the utility of WBE programs, particularly in remote/rural regions where reliable cold storage and/or rapid shipping may be unavailable. This study examined whether rapid SARS-CoV-2 RNA extraction on the day of sample collection could minimize degradation. Importantly, the extraction technology used in these experiments, termed exclusion-based sample preparation (ESP), is lightweight, portable, and electricity-free, making it suitable for implementation in remote settings. We demonstrated that immediate RNA extraction followed by ambient storage significantly increased the RNA half-life compared to raw wastewater samples stored at both 4 °C or ambient temperature. Given that RNA degradation negatively impacts both the sensitivity and precision of WBE measurements, efforts must be made to mitigate degradation in order to maximize the potential impact of WBE on public health.


Assuntos
COVID-19 , Humanos , RNA Viral , SARS-CoV-2/genética , Águas Residuárias , Eletricidade
4.
ACS ES T Water ; 2(11): 1984-1991, 2022 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-37552725

RESUMO

Over the course of the COVID-19 pandemic, wastewater surveillance has become a useful tool for describing SARS-CoV-2 prevalence in populations of varying size, from individual facilities (e.g., university residence halls, nursing homes, prisons) to entire municipalities. Wastewater analysis for SARS-CoV-2 RNA requires specialized equipment, expensive consumables, and expert staff, limiting its feasibility and scalability. Further, the extremely labile nature of viral RNA complicates sample transportation, especially in regions with limited access to reliable cold chains. Here, we present a new method for wastewater analysis, termed exclusion-based sample preparation (ESP), that substantially simplifies workflow (at least 70% decrease in time; 40% decrease in consumable usage compared with traditional techniques) by targeting the labor-intensive processing steps of RNA purification and concentration. To optimize and validate this method, we analyzed wastewater samples from residence halls at the University of Kentucky, of which 34% (44/129) contained detectible SARS-CoV-2 RNA. Although concurrent clinical testing was not comprehensive, student infections were identified in the 7 days following a positive wastewater detection in 68% of samples. This pilot study among university residence halls validated the performance and utility of the ESP method, laying the foundation for future studies in regions of the world where wastewater testing is not currently feasible.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA