Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Ecotoxicology ; 30(4): 705-710, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33761023

RESUMO

Among the new contaminants relevant for environment, one of the most significant roles is played by pharmaceuticals like antibiotic products for either human or veterinary use. Their presence could cause serious damage to bacteria and microfauna, like nematodes. Within the widely investigated nematodes, very little is known about the interaction between antibiotics and entomopathogenic nematodes (EPN). EPNs have been used for biological control of crops, due to their ability to penetrate arthropod pests and kill their hosts thanks to a complex symbiotic mechanism with specific gram-negative bacteria. Tetracycline is an antibiotic used in human and veterinary medicine, both for therapeutic purposes and for the growth of livestock. Since its action against gram-negative bacteria is documented, we verified in this study the survival, growth and pathogenicity of two species of EPNs, Steinernema vulcanicum and S. feltiae. All tests were performed with tetracycline in 1% ethanol solution and up to 300 mg/L. Apparently, this incubation did not harm the vitality of EPNs. Both S. vulcanicum as S. feltiae recovered their vitality and entomopathogenic ability after 48 h. Moreover, the latter EPN species did not grow nor reproduce in the hemolymph of the Greater Wax Moth, Galleria mellonella, and their endosymbionts did not grow on MacConkey Agar. Our results suggest that the first EPN species has always retained all its abilities and that endosymbionts have acquired resistance to tetracycline, while experiments with the second EPN species provided some contrasting results in time that will require further investigations.


Assuntos
Mariposas , Rabditídios , Animais , Antibacterianos/toxicidade , Bactérias , Humanos , Tetraciclinas
2.
Int J Dent ; 2018: 2514243, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30410540

RESUMO

INTRODUCTION: A radiological evaluation is essential in endodontics, for diagnostic purposes, planning and execution of the treatment, and evaluation of the success of therapy. The periapical radiography is nowadays the main radiographic investigations used but presents some limits as 3D anatomic alteration, geometric compression, and possible anatomical structures overlapping that can obscure the area of interest. CBCT (cone beam computed tomography) in endodontics allows a detailed assessment of the teeth and surrounding alveolar anatomy for endodontic diagnosis, treatment planning, and follow-up. OBJECTIVE: The purpose of this study was to evaluate the accuracy of CBCT in comparison with conventional intraoral radiographs used in endodontic procedures. MATERIALS AND METHODS: Statistical analysis was performed on 101 patients with previous endodontic treatments with the relative radiographic documentation (preoperative, postoperative, and follow-up intraoral X-ray) that had underwent at CBCT screening for surgical reasons. The CBCT scans were evaluated independently by two operators and compared with the corresponding periapical images. RESULTS: Our analysis shows that the two radiological investigations statistically agree in 100% of cases in the group of patients without any endodontic sign. In the group of patients with an endodontic pathology, detected with CBCT, endodontic under extended treatments (30.6%), MB2 canals in nontreated maxillary molars (20.7%), second canals in nontreated mandibular incisors (9%), root fractures (2.7%), and root resorption (2.7%) were not always visible in intraoral X-ray. Otherwise, positivity in the intraoral X-ray was always confirmed in CBCT. A radiolucent area was detected in CBCT exam in 46%, while the intraoral X-ray exam was positive only in 18%. CONCLUSIONS: Our study shows that some important radiological signs acquired using CBCT are not always visible in periapical X-ray. Furthermore, CBCT is considered as a II level exam and could be used to solve diagnostic questions, essential to a proper management of the endodontic problems.

3.
Eur J Neurol ; 25(3): 556-e33, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29266547

RESUMO

BACKGROUND AND PURPOSE: Forced vital capacity (FVC) <80% is one of the key indications for starting non-invasive ventilation (NIV) in amyotrophic lateral sclerosis (ALS). It was hypothesized that a very early start of NIV could lengthen the free interval before death compared to later-start NIV; as a secondary outcome, the survival rate of patients on NIV without tracheotomy was also evaluated. METHODS: This retrospective study was conducted on 194 ALS patients, divided into a later group (LG) with FVC <80% at NIV prescription (n = 129) and a very early group (VEG) with FVC ≥80% at NIV prescription (n = 65). Clinical and respiratory functional data and time free to death between groups over a 3-year follow-up were compared. RESULT: At 36 months from diagnosis, mortality was 35% for the VEG versus 52.7% for the LG (P = 0.022). Kaplan-Meier survival curves adjusted for tracheotomy showed a lower probability of death (P = 0.001) for the VEG as a whole (P = 0.001) and for the non-bulbar (NB) subgroup (P = 0.007). Very early NIV was protective of survival for all patients [hazard ratio (HR) 0.45; 95% confidence interval (CI) 0.28-0.74; P = 0.001] and for the NB subgroup (HR 0.43; 95% CI 0.23-0.79; P = 0.007), whilst a tracheotomy was protective for all patients (HR 0.27; 95% CI 0.15-0.50; P = 0.000) and both NB (HR 0.26; 95% CI 0.12-0.56; P = 0.001) and bulbar subgroups (HR 0.29; 95% CI 0.11-0.77; P = 0.013). Survival in VEG patients on NIV without tracheotomy was three times that for the LG (43.1% vs. 14.7%). CONCLUSION: Very early NIV prescription prolongs the free time from diagnosis to death in NB ALS patients whilst tracheotomy reduces the mortality risk in all patients.


Assuntos
Esclerose Lateral Amiotrófica/mortalidade , Esclerose Lateral Amiotrófica/terapia , Ventilação não Invasiva/estatística & dados numéricos , Avaliação de Resultados em Cuidados de Saúde , Traqueostomia/estatística & dados numéricos , Idoso , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Ventilação não Invasiva/métodos , Insuficiência Respiratória/mortalidade , Estudos Retrospectivos , Fatores de Tempo , Traqueostomia/métodos
4.
Int Endod J ; 50(2): 194-201, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26786274

RESUMO

AIM: To investigate the influence of interrupted rotation on cyclic fatigue of two nickel-titanium rotary instruments. METHODOLOGY: Cyclic fatigue of 300 new ProTaper Next size X1; X2 and Mtwo size 10, .04 taper; size 15, .05 taper; size 20, .06 taper and size 25, .06 taper instruments was tested in continuous or interrupted rotation. Fifty files of the same brand and size were randomly assigned to five groups (n = 10). Group 1 instruments were tested in continuous rotation; groups 2 and 3 in paused rotation for 1 s every 10 or 20 s, respectively; groups 4 and 5 in interrupted rotation for 5 s every 10 or 20 s, respectively. Cyclic fatigue was expressed in time to fracture (TtF) in an artificial canal with 60° angle and 5 mm radius of curvature. The fracture surface was examined with a scanning electron microscope (SEM). Data were evaluated by two-way analysis of variance. RESULTS: Cyclic fatigue of groups 2 and 4 of ProTaper Next X2 and Mtwo size 25, .06 taper was significantly lower than that of group 1 of the same instruments (P < 0.01). ProTaper Next X2 had significantly reduced cyclic fatigue in groups 3 and 5 (P < 0.05). No differences were found by interrupting the rotation for 1 or 5 s in all instruments (P > 0.05). Fatigue of other instruments was not affected by interrupted rotation (P > 0.05). CONCLUSIONS: Interrupted rotation reduced cyclic fatigue resistance of ProTaper Next X2 and Mtwo size 25, .06 taper, especially when a higher number of interruptions was performed.


Assuntos
Instrumentos Odontológicos/normas , Níquel , Titânio , Rotação
5.
Open Dent J ; 10: 242-50, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27386010

RESUMO

BACKGROUND: Auxiliary power sources (LED and laser) are used in in-office teeth bleaching techniques to accelerate the redox reaction of the whitening gel to increase ease of use, to improve comfort and safety, and to decrease the procedure time. OBJECTIVE: The aim this study is to evaluate the efficiency of the teeth whitening procedures performed with hydrogen peroxide and carbamide peroxide, LED or Laser activated. METHOD: 18 patients, affected by exogenous dyschromia, were treated with a bleaching agent composed by 35% hydrogen peroxide and 10% carbamide peroxide. They were divided into two groups: in the first group the bleaching agent was activated by a LED lamp; in the second group it was activated by a Laser diode lamp. Both groups were subjected to 3 bleaching cycle of 15' each. The chromatic evaluations were performed before and after one week from the treatment, using a chromatic scale and a spectrophotometer. The mean value of pre, post bleaching and follow-up were analyzed using a T-test, with results statistically significant for P<0,05. RESULTS: Results showed that the variations in brightness, chroma and hue are significantly influenced by the interaction between the whitening agent and the original colour of the teeth. Laser-activation has marginally improved the bleaching effectiveness. All patients treated with laser activation complained an increase in dental sensitivity. CONCLUSION: The use of laser-activating systems did not improve the efficacy of bleaching.

6.
Indian J Dent Res ; 23(6): 763-9, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23649060

RESUMO

PURPOSE: The aim of this study is to investigate the presence and the extent of a possible marginal gap after the interposition of a flowable composite between the composite restoration and the dental structures (enamel and cementum). This technique is also used to eliminate the infiltration in a zone of the cavity preparation that is frequently at a risk of secondary decay. MATERIALS AND METHODS: Fifteen human premolars extracted for orthodontic reasons were used for the study. A cavity with mesial and distal margin in enamel and cementum was realized in every tooth. The cavities were then restored with an adhesive system (ScotchBond 3MÔ) and composite (Filtek Supreme 3MÔ); and, a fine layer of flowable composite was applied in the distal margin of each cavity. Scanning electron microscopy (SEM) in secondary electron imaging (S.E.I.) modality was used for the study and identifying the marginal gaps in the composite restorations. Data was investigated on the mesial and distal margin of each cavity at the restoration-enamel interface, and at the restoration-cementum interface. The interfaces were divided in four groups: Group A (enamel/composite); Group B (enamel/flow/composite); Group C (cementum/composite); and, Group D (cementum/flow/composite). RESULTS: By the comparison of the gap's average width found in each group, it is evidenced that the average width of the gap increases when the interface moves from the coronal to the radicular end (Group A 0,1 ± 0,4 µm Vs Group C 12,3 ± 11,6 µm; Group B 0,2 ± 0,8 µm Vs Group D 2,8 ± 6,6 µm). Correlating the measurements of the marginal gap's average width among the Group A and Group B, no significant variations were obtained; and instead, on comparing Group C with Group D, the gap's average width decreases. CONCLUSION: The interposition of a low elastic modulus composite between the adhesive layer and the composite resin allows an improvement of the cementum-restoration interface by the means of a lower shrinkage stress during polymerization.


Assuntos
Resinas Compostas/química , Preparo da Cavidade Dentária/métodos , Cemento Dentário/ultraestrutura , Esmalte Dentário/ultraestrutura , Adaptação Marginal Dentária , Restauração Dentária Permanente/métodos , Módulo de Elasticidade , Humanos , Teste de Materiais , Microscopia Eletrônica de Varredura , Nanocompostos/química , Polimerização , Cimentos de Resina/química , Propriedades de Superfície , Viscosidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA