Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Br J Radiol ; 94(1124): 20210061, 2021 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-34106779

RESUMO

Hepatic venous pressure gradient (HVPG) is the gold-standard for measurement of portal hypertension, a common cause for life-threatening conditions such as variceal bleeding and hepatic encephalopathy. HVPG also plays a crucial role in risk stratification, treatment selection and assessment of treatment response. Thus recognition of common pitfalls and unusual hepatic venous conditions is crucial. This article aims to provide a radiographical and clinical guide to HVPG with representative clinical cases.


Assuntos
Hipertensão Portal/diagnóstico por imagem , Hipertensão Portal/fisiopatologia , Pressão na Veia Porta , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
4.
Ultrasound ; 25(4): 213-221, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29163657

RESUMO

OBJECTIVE: Liver cirrhosis has been a rising complication of chronic liver disease in Singapore. Ultrasound has been widely accepted as a non-invasive imaging modality for the evaluation of hepatic haemodynamics. This study aims to correlate the Doppler ultrasound values with the progression of liver cirrhosis to allow further understanding and possible prediction of clinical events for timely intervention. METHODS: Study sample of 56 eligible patients with liver cirrhosis was divided according to their Child-Pugh clinical score into Child's A (n = 29 patients), B (n = 19 patients) and C (n = 8 patients). The maximum portal vein velocity, maximum hepatic vein velocity, maximum hepatic artery velocity and hepatic artery resistive index were assessed by Doppler ultrasound. RESULTS: The incidence of ascites increases with the severity of cirrhosis. Flattening of the hepatic vein waveforms was dependant on degree of liver cirrhosis. Maximum hepatic vein velocity was higher in cirrhotic patients (where p = 0.05). Maximum portal vein velocity was found to be lower in cirrhosis (where p < 0.001) and mean maximum portal vein velocity decreases as severity of cirrhosis worsens. Hepatic artery resistive index was significantly higher in cirrhosis (where p < 0.001). Significant association was found between maximum hepatic vein velocity and maximum hepatic artery velocity and significant negative correlation was observed with the maximum portal vein velocity and hepatic artery resistive index. CONCLUSION: The study demonstrated that these parameters can supplement the evaluation of liver cirrhosis and will be able to distinguish the different grades of liver cirrhosis using Doppler ultrasound.

6.
Ann Acad Med Singap ; 46(2): 64-71, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28263343

RESUMO

INTRODUCTION: An arteriovenous fistula (AVF) is the preferred method for haemodialysis in patients with end-stage renal failure. Previous studies have shown value in attempting percutaneous transluminal angioplasty (PTA) to salvage AVFs that fail to mature, but they are relatively small in size and mainly reported in Western populations. We reviewed our data of PTA in non-maturing AVFs to establish whether this technique is translatable to our local multiethnic population. MATERIALS AND METHODS: We retrospectively reviewed the medical records and procedural images of 105 patients who had PTA for non-maturing AVFs performed at our department from January 2008 to January 2011. Technical success was defined as ≤30% residual stenosis after angioplasty. Clinical success was defined as at least 1 successful haemodialysis session within 4 weeks after PTA. RESULTS: All 105 patients underwent angioplasty for at least 1 haemodynamically significant stenosis. Six (5.7%) had additional embolisation of accessory veins. Technical success was achieved in 95.2% of cases. The clinical success rate was 76.2%. Primary patency rates at 3, 6 and 12 months were 83%, 45% and 28%, respectively. Secondary patency rates at 3, 6 and 12 months were 90%, 79% and 70%, respectively. The minor complication rate was 18.1%. No major complications were encountered. An average of 1.7 interventions per access-year was required to maintain AVF patency. Patients with a preoperative vein size >2.0 mm and age <55 years were more likely to achieve clinical success, although not statistically significant. CONCLUSION: PTA is a viable option to help salvage non-maturing AVFs in a multiethnic Asian population.


Assuntos
Angioplastia/métodos , Derivação Arteriovenosa Cirúrgica , Constrição Patológica/terapia , Falência Renal Crônica/terapia , Embolização Terapêutica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Diálise Renal , Reoperação , Estudos Retrospectivos , Singapura , Veias
7.
EJNMMI Res ; 3(1): 57, 2013 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-23885971

RESUMO

BACKGROUND: Coincidence imaging of low-abundance yttrium-90 (90Y) internal pair production by positron emission tomography with integrated computed tomography (PET/CT) achieves high-resolution imaging of post-radioembolization microsphere biodistribution. Part 2 analyzes tumor and non-target tissue dose-response by 90Y PET quantification and evaluates the accuracy of tumor 99mTc macroaggregated albumin (MAA) single-photon emission computed tomography with integrated CT (SPECT/CT) predictive dosimetry. METHODS: Retrospective dose quantification of 90Y resin microspheres was performed on the same 23-patient data set in part 1. Phantom studies were performed to assure quantitative accuracy of our time-of-flight lutetium-yttrium-oxyorthosilicate system. Dose-responses were analyzed using 90Y dose-volume histograms (DVHs) by PET voxel dosimetry or mean absorbed doses by Medical Internal Radiation Dose macrodosimetry, correlated to follow-up imaging or clinical findings. Intended tumor mean doses by predictive dosimetry were compared to doses by 90Y PET. RESULTS: Phantom studies demonstrated near-perfect detector linearity and high tumor quantitative accuracy. For hepatocellular carcinomas, complete responses were generally achieved at D70 > 100 Gy (D70, minimum dose to 70% tumor volume), whereas incomplete responses were generally at D70 < 100 Gy; smaller tumors (<80 cm3) achieved D70 > 100 Gy more easily than larger tumors. There was complete response in a cholangiocarcinoma at D70 90 Gy and partial response in an adrenal gastrointestinal stromal tumor metastasis at D70 53 Gy. In two patients, a mean dose of 18 Gy to the stomach was asymptomatic, 49 Gy caused gastritis, 65 Gy caused ulceration, and 53 Gy caused duodenitis. In one patient, a bilateral kidney mean dose of 9 Gy (V20 8%) did not cause clinically relevant nephrotoxicity. Under near-ideal dosimetric conditions, there was excellent correlation between intended tumor mean doses by predictive dosimetry and those by 90Y PET, with a low median relative error of +3.8% (95% confidence interval, -1.2% to +13.2%). CONCLUSIONS: Tumor and non-target tissue absorbed dose quantification by 90Y PET is accurate and yields radiobiologically meaningful dose-response information to guide adjuvant or mitigative action. Tumor 99mTc MAA SPECT/CT predictive dosimetry is feasible. 90Y DVHs may guide future techniques in predictive dosimetry.

8.
EJNMMI Res ; 3(1): 56, 2013 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-23883566

RESUMO

BACKGROUND: Yttrium-90 (90Y) positron emission tomography with integrated computed tomography (PET/CT) represents a technological leap from 90Y bremsstrahlung single-photon emission computed tomography with integrated computed tomography (SPECT/CT) by coincidence imaging of low abundance internal pair production. Encouraged by favorable early experiences, we implemented post-radioembolization 90Y PET/CT as an adjunct to 90Y bremsstrahlung SPECT/CT in diagnostic reporting. METHODS: This is a retrospective review of all paired 90Y PET/CT and 90Y bremsstrahlung SPECT/CT scans over a 1-year period. We compared image resolution, ability to confirm technical success, detection of non-target activity, and providing conclusive information about 90Y activity within targeted tumor vascular thrombosis. 90Y resin microspheres were used. 90Y PET/CT was performed on a conventional time-of-flight lutetium-yttrium-oxyorthosilicate scanner with minor modifications to acquisition and reconstruction parameters. Specific findings on 90Y PET/CT were corroborated by 90Y bremsstrahlung SPECT/CT, 99mTc macroaggregated albumin SPECT/CT, follow-up diagnostic imaging or review of clinical records. RESULTS: Diagnostic reporting recommendations were developed from our collective experience across 44 paired scans. Emphasis on the continuity of care improved overall diagnostic accuracy and reporting confidence of the operator. With proper technique, the presence of background noise did not pose a problem for diagnostic reporting. A counter-intuitive but effective technique of detecting non-target activity is proposed, based on the pattern of activity and its relation to underlying anatomy, instead of its visual intensity. In a sub-analysis of 23 patients with a median follow-up of 5.4 months, 90Y PET/CT consistently outperformed 90Y bremsstrahlung SPECT/CT in all aspects of qualitative analysis, including assessment for non-target activity and tumor vascular thrombosis. Parts of viscera closely adjacent to the liver remain challenging for non-target activity detection, compounded by a tendency for mis-registration. CONCLUSIONS: Adherence to proper diagnostic reporting technique and emphasis on continuity of care are vital to the clinical utility of post-radioembolization 90Y PET/CT. 90Y PET/CT is superior to 90Y bremsstrahlung SPECT/CT for the assessment of target and non-target activity.

9.
Ann Acad Med Singap ; 40(7): 308-14, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21870021

RESUMO

INTRODUCTION: Cone beam computed tomography (CBCT) is a relatively new technological innovation that utilises fl at-panel detector technology to obtain CT-like images. The key strength of a CBCT system is that cross-sectional imaging can be obtained using the angiographic fl at panel unit without having to move the patient, allowing the radiologist to obtain soft tissue imaging during the procedure. This allows treatment planning, guidance, and assessment of outcome to be performed in one interventional suite. MATERIALS AND METHODS: From December 2008 to June 2009, 24 CBCT scans were performed during vascular interventional procedures on our department's newly installed multi-axis fl at panel angiographic unit. RESULTS: Ten cases were performed for hepatic trans-arterial chemoembolisation, 9 cases for hepatic arterial Yttrium-90 infusion, while 5 cases were for other indications. CBCT was found to be useful in 20 of the 24 cases. CONCLUSION: Our early experience showed that CBCT was useful in impacting decisions during selected vascular interventional procedures. As CBCT technology improves, we can foresee wider applications of this technology.


Assuntos
Angiografia , Tomografia Computadorizada de Feixe Cônico/normas , Radiologia Intervencionista/métodos , Idoso , Embolização Terapêutica , Feminino , Humanos , Masculino , Auditoria Médica , Pessoa de Meia-Idade , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA