Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
2.
J Am Heart Assoc ; 13(4): e032963, 2024 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-38348804

RESUMO

BACKGROUND: Acute ischemic stroke complicates 2% to 3% of transcatheter aortic valve replacements (TAVRs). This study aimed to identify the aortic anatomic correlates in patients after TAVR stroke. METHODS AND RESULTS: This is a single-center, retrospective study of patients who underwent TAVR at the Mayo Clinic between 2012 and 2022. The aortic arch morphology was determined via a manual review of the pre-TAVR computed tomography images. An "a priori" approach was used to select the covariates for the following: (1) the logistic regression model assessing the association between a bovine arch and periprocedural stroke (defined as stroke within 7 days after TAVR); and (2) the Cox proportional hazards regression model assessing the association between a bovine arch and long-term stroke after TAVR. A total of 2775 patients were included (59.6% men; 97.8% White race; mean±SD age, 79.3±8.4 years), of whom 495 (17.8%) had a bovine arch morphology. Fifty-seven patients (1.7%) experienced a periprocedural stroke. The incidence of acute stroke was significantly higher among patients with a bovine arch compared with those with a nonbovine arch (3.6% versus 1.7%; P=0.01). After adjustment, a bovine arch was independently associated with increased periprocedural strokes (adjusted odds ratio, 2.16 [95% CI, 1.22-3.83]). At a median follow-up of 2.7 years, the overall incidence of post-TAVR stroke was 6.0% and was significantly higher in patients with a bovine arch even after adjusting for potential confounders (10.5% versus 5.0%; adjusted hazard ratio, 2.11 [95% CI, 1.51-2.93]; P<0.001). CONCLUSIONS: A bovine arch anatomy is associated with a significantly higher risk of periprocedural and long-term stroke after TAVR.


Assuntos
Estenose da Valva Aórtica , AVC Isquêmico , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Masculino , Humanos , Idoso , Idoso de 80 Anos ou mais , Feminino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/cirurgia , Estudos Retrospectivos , AVC Isquêmico/cirurgia , Resultado do Tratamento , Fatores de Risco , Acidente Vascular Cerebral/etiologia
3.
Heart Rhythm ; 2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38365125

RESUMO

BACKGROUND: The hemodynamic effects of transcatheter left atrial appendage occlusion (LAAO) remain unclear. OBJECTIVE: We sought to assess the effect of LAAO on invasive hemodynamics and their correlation with clinical outcomes. METHODS: We recorded mean left atrial pressure (mLAP) before and after device deployment. We assessed the prevalence and predictors of mLAP increase after deployment, the association between significant mLAP increase after deployment and 45-day peridevice leak (PDL), and the association between mLAP increase and heart failure (HF) hospitalization. A significant mLAP increase was defined as one equal to or greater than the mean percentage increase in mLAP after deployment (≥28%). RESULTS: We included 302 patients (36.4% female; mean age, 75.8 ± 9.5 years). After deployment, mLAP increased in 48% of patients, 38% of whom experienced significant mLAP increase. Independent predictors of mLAP increase were baseline mLAP ≤14 mm Hg, nonparoxysmal atrial fibrillation, and age per 5 years (odds ratios: 3.66 [95% CI, 2.21-6.05], 1.81 [95% CI, 1.08-3.02], and 0.85 [95% CI, 0.73-0.99], respectively). Significant mLAP increase was an independent predictor of 45-day PDL (odds ratio, 2.55; 95% CI, 1.04-6.26). There was no association between mLAP increase and HF hospitalization. CONCLUSION: After deployment, mLAP acutely rises in 48% of patients, although this is not associated with increased HF hospitalizations. PDL is more likely to develop at 45 days in patients with significant increase in mLAP after deployment, although most leaks were small (<5 mm). These findings suggest that mLAP increase after deployment is not associated with major safety concerns. Additional studies are warranted to explore the long-term hemodynamic effects of LAAO.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA