Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 109
Filtrar
1.
Acta Diabetol ; 2024 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-38615127

RESUMO

AIM: Conflicting findings have been reported on whether in youths, the double diagnosis of type 1 diabetes (T1D) and celiac disease (CD) substantially impacts quality of life QoL, compared to subjects with T1D only. METHODS: In this study, 86 youths with double diagnosis and their parents were compared to 167 subjects with T1D only. QoL was assessed through the KINDL questionnaire. Anti-tissue transglutaminase antibodies and dietary interviews evaluated the degree of maintaining a gluten-free diet (GFD). RESULTS: We found that having CD in addition to T1D has little effect on overall QoL. However, analysis of the degree of maintaining GFD revealed significantly lower total QoL scores in groups with T1D + CD not strictly maintaining GFD compared to T1D only (p = 0.0014). The multivariable linear regression model confirmed the importance of maintaining GFD on QoL in subjects (p = 0.0066) and parents (p = 0.023). CONCLUSION: The coexistence of T1D and CD and the adoption of a GFD resulted in poor QoL levels, as in youth as in their parents, when difficulties implementing the GFD are present. Psychological support should consider the importance of maintaining GFD not only to prevent potential complications in the future but also to improve actual QoL in different subdomains.

2.
Diabetes Care ; 47(6): 1084-1091, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38626260

RESUMO

OBJECTIVE: To investigate glucose metrics and identify potential predictors of the achievement of glycemic outcomes in children and adolescents during their first 12 months of MiniMed 780G use. RESEARCH DESIGN AND METHODS: This multicenter, longitudinal, real-world study recruited 368 children and adolescents with type 1 diabetes (T1D) starting SmartGuard technology between June 2020 and June 2022. Ambulatory glucose profile data were collected during a 15-day run-in period (baseline), 2 weeks after automatic mode activation, and every 3 months. The influence of covariates on glycemic outcomes after 1 year of MiniMed 780G use was assessed. RESULTS: After 15 days of automatic mode use, all glucose metrics improved compared with baseline (P < 0.001), except for time below range (P = 0.113) and coefficient of variation (P = 0.330). After 1 year, time in range (TIR) remained significantly higher than at baseline (75.3% vs. 62.8%, P < 0.001). The mean glycated hemoglobin (HbA1c) over the study duration was lower than the previous year (6.9 ± 0.6% vs. 7.4 ± 0.9%, P < 0.001). Time spent in tight range (70-140 mg/dL) was 51.1%, and the glycemia risk index was 27.6. Higher TIR levels were associated with a reduced number of automatic correction boluses (P < 0.001), fewer SmartGuard exits (P = 0.021), and longer time in automatic mode (P = 0.030). Individuals with baseline HbA1c >8% showed more relevant improvement in TIR levels (from 54.3% to 72.3%). CONCLUSIONS: Our study highlights the sustained effectiveness of MiniMed 780G among youth with T1D. Findings suggest that even children and adolescents with low therapeutic engagement may benefit from SmartGuard technology.


Assuntos
Glicemia , Diabetes Mellitus Tipo 1 , Sistemas de Infusão de Insulina , Insulina , Humanos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/sangue , Adolescente , Criança , Masculino , Feminino , Glicemia/análise , Glicemia/metabolismo , Insulina/administração & dosagem , Insulina/uso terapêutico , Hipoglicemiantes/uso terapêutico , Hipoglicemiantes/administração & dosagem , Estudos Longitudinais , Automonitorização da Glicemia/métodos , Hemoglobinas Glicadas/metabolismo , Hemoglobinas Glicadas/análise
3.
Acta Diabetol ; 61(5): 635-642, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38381182

RESUMO

AIMS: In view of the imminent introduction of a novel category of disease-modifying treatments for type 1 diabetes (T1D) in European countries, it becomes imperative to understand the existing awareness and viewpoints of parents and caregivers of children and adolescents predisposed to T1D. This study aims to evaluate the perspectives of a cohort of parents and caregivers regarding using teplizumab to delay the onset of T1D in predisposed children and adolescents. METHODS: This single-center study used a survey-based approach. Parents or caregivers of children and adolescents with T1D having at least one additional child without T1D answered 15 questions assessing their awareness about teplizumab, their potential willingness to provide consent for its administration in case of eligibility, and their expectations regarding potential outcomes. RESULTS: Approximately half of the participants (52.6%) expressed readiness to consent to teplizumab administration for their child if the prescription criteria were met in the future. Only 6.3% of parents claimed detailed knowledge about this innovative medication. Notably, parents with prior experience of diabetic ketoacidosis (DKA) demonstrated a higher inclination to consent to teplizumab treatment (p = 0.018). CONCLUSIONS: Our findings underscore the necessity for comprehensive awareness campaigns spreading the current evidence concerning teplizumab in terms of both effectiveness and possible side effects. Additionally, our study reinforces the pivotal role of DKA prevention in successfully integrating disease-modifying treatments into clinical practice.


Assuntos
Anticorpos Monoclonais Humanizados , Cuidadores , Diabetes Mellitus Tipo 1 , Pais , Humanos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Adolescente , Criança , Masculino , Feminino , Pais/psicologia , Anticorpos Monoclonais Humanizados/uso terapêutico , Cuidadores/psicologia , Cuidadores/estatística & dados numéricos , Itália/epidemiologia , Adulto , Inquéritos e Questionários , Pré-Escolar , Conhecimentos, Atitudes e Prática em Saúde
4.
Acta Diabetol ; 61(5): 599-607, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38332378

RESUMO

AIM: In Italy, the ISPED CARD initiative was launched to measure and improve quality of care in children and adolescents with type 1 diabetes. METHODS: Process and outcome indicators and the related information derived from electronic medical records were identified. A network of pediatric diabetes centers was created on a voluntary basis. RESULTS: Overall, 20 centers provided data on 3284 patients aged < = 18 years. HbA1c was monitored ≥ 2/year in 81.2% of the cases. BMI was monitored ≥ 1/year in 99.0%, lipid profile in 45.3%, and blood pressure in 91.7%. Pubertal status, albuminuria, eye examination, and screening of celiac disease and thyroiditis were underreported. From 2017 to 2021, average HbA1c levels decreased from 7.8 ± 1.2 to 7.6 ± 1.3%, while patients with LDL cholesterol > 100 mg/dl increased from 18.9 to 36.7%. Prevalence of patients with elevated blood pressure and BMI/SDS values also increased. In 2021, 44.7% of patients were treated with the newest basal insulins, while use of regular human insulin had dropped to 7.7%. Use of insulin pump remained stable (37.9%). CONCLUSIONS: This report documents the feasibility of the ISPED CARD initiative and shows lights and shadows in the care provided. Improving care, increasing number of centers, and ameliorating data recording represent future challenges.


Assuntos
Diabetes Mellitus Tipo 1 , Melhoria de Qualidade , Sistema de Registros , Humanos , Criança , Adolescente , Masculino , Feminino , Sistema de Registros/estatística & dados numéricos , Diabetes Mellitus Tipo 1/terapia , Itália/epidemiologia , Hemoglobinas Glicadas/análise , Hemoglobinas Glicadas/metabolismo , Pré-Escolar , Qualidade da Assistência à Saúde/normas , Lactente
5.
Diabet Med ; 41(6): e15307, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38383984

RESUMO

AIMS: While continuous glucose monitoring (CGM) and associated technologies have positive effects on metabolic control in young people with type 1 diabetes (T1D), less is known about their impact on quality of life (QoL). Here, we quantified CGM satisfaction and QoL in young people with T1D and their parents/caregivers to establish (i) the relationship between QoL and CGM satisfaction and (ii) the impact of the treatment regimen on QoL. METHODS: This was a cross-sectional study of children and adolescents with T1D on different treatment regimens (multiple daily injections, sensor-augmented pumps and automated insulin delivery). QoL was assessed with the KINDL instrument, and CGM satisfaction with the CGM-SAT questionnaire was evaluated in both youths with T1D and their parents. RESULTS: Two hundred and ten consecutively enrolled youths with T1D completed the KINDL and CGM-SAT questionnaires. The mean total KINDL score was greater than neutral in both subjects with T1D (3.99 ± 0.47) and parents (4.06 ± 0.40), and lower overall CGM-SAT scores (i.e., higher satisfaction) were significantly associated with higher QoL in all six KINDL subscales (p < 0.05). There were no differences in KINDL scores according to delivery technology or when participants were grouped according to optimal and sub-optimal glucose control. CONCLUSIONS: Higher satisfaction with recent CGMs was associated with better QoL in all dimensions. QoL was independent of both the insulin delivery technology and glycaemic control. CGM must be further disseminated. Attention on perceived satisfaction with CGM should be incorporated with the clinical practice to improve the well-being of children and adolescents with T1D and their families.


Assuntos
Automonitorização da Glicemia , Diabetes Mellitus Tipo 1 , Hipoglicemiantes , Sistemas de Infusão de Insulina , Insulina , Satisfação do Paciente , Qualidade de Vida , Humanos , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/psicologia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Adolescente , Masculino , Feminino , Criança , Estudos Transversais , Insulina/uso terapêutico , Insulina/administração & dosagem , Hipoglicemiantes/uso terapêutico , Controle Glicêmico , Glicemia/metabolismo , Glicemia/análise , Inquéritos e Questionários , Pais/psicologia , Hemoglobinas Glicadas/metabolismo , Hemoglobinas Glicadas/análise , Monitoramento Contínuo da Glicose
6.
Children (Basel) ; 11(2)2024 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-38397323

RESUMO

The introduction of continuous glucose monitoring (CGM) systems in clinical practice has allowed a more detailed picture of the intra- and interdaily glycemic fluctuations of individuals with type 1 diabetes (T1D). However, CGM-measured glucose control indicators may be occasionally inaccurate. This study aims to assess the discrepancy between the glucose management indicator (GMI) and glycated hemoglobin (HbA1c) (ΔGMI-HbA1c) within a cohort of children and adolescents with T1D, exploring its correlation with other CGM metrics and blood count parameters. In this single-center, cross-sectional study, we gathered demographic and clinical data, including blood count parameters, HbA1c values, and CGM metrics, from 128 pediatric subjects with T1D (43% female; mean age, 13.4 ± 3.6 years). Our findings revealed higher levels of the coefficient of variation (CV) (p < 0.001) and time above range > 250 mg/dL (p = 0.033) among subjects with ΔGMI-HbA1c > 0.3%. No association was observed between blood count parameters and ΔGMI-HbA1c. In conclusion, despite the advancements and the widespread adoption of CGM systems, HbA1c remains an essential parameter for the assessment of glycemic control, especially in individuals with suboptimal metabolic control and extreme glycemic variability.

7.
Diabetes Technol Ther ; 26(3): 161-166, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37902743

RESUMO

Introduction: To evaluate time in tight range (TITR) 70-140 mg/dL (3.9-7.8 mmol/L), its correlation with standard continuous glucose monitoring (CGM) metrics and the clinical variables that possibly have a substantial impact on its value, in a large cohort of pediatric subjects using different treatment strategies. Materials and Methods: A total of 854 children and adolescents with type 1 diabetes were consecutively recruited in this real world, dual center, cross-sectional study. Participants were categorized into four treatment groups (multiple daily injections [MDI] + real-time CGM, MDI + intermittently scanned CGM, sensor augmented pump, and hybrid closed loop [HCL]). Demographical and clinical data, including CGM data, were collected and analyzed. Results: The overall study population exhibited an average TITR of 36.4% ± 12.8%. HCL users showed higher TITR levels compared to the other treatment groups (P < 0.001). A time in range (TIR) cut-off value of 71.9% identified subjects achieving a TITR ≥50% (area under curve [AUC] 0.98; 95% confidence interval 0.97-0.99, P < 0.001), and a strong positive correlation between these two metrics was observed (r = 0.95, P < 0.001). An increase in TIR of 1% was associated with 1.84 (R2 Nagelkerke = 0.35, P < 0.001) increased likelihood of achieving TITR ≥50%. Use of HCL systems (B = 7.78; P < 0.001), disease duration (B = -0.26, P = 0.006), coefficient of variation (B = -0.30, P = 0.004), and glycated hemoglobin (B = -8.82; P < 0.001) emerged as significant predictors of TITR levels. Conclusions: Our study highlights that most children and adolescents with type 1 diabetes present TITR levels below 50%, except those using HCL. Tailored interventions and strategies should be implemented to increase TITR.


Assuntos
Diabetes Mellitus Tipo 1 , Humanos , Criança , Adolescente , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/uso terapêutico , Glicemia , Controle Glicêmico , Automonitorização da Glicemia , Monitoramento Contínuo da Glicose , Estudos Transversais , Insulina/uso terapêutico
9.
Diabetes Ther ; 15(2): 343-365, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38038896

RESUMO

The MiniMed™ 780G is a second-generation automated insulin delivery system that implements a modified proportional-integral-derivative algorithm with some features of an MD-Logic artificial pancreas algorithm. The system may deliver automatic correction boluses up to every 5 min, and it allows the user to choose between three glucose target setpoints (100, 110 and 120 mg/dL). We aimed to review the current evidence on this device in children, adolescents, and young adults living with type 1 diabetes. We screened 783 papers, but only 31 manuscripts were included in this review. Data on metabolic outcomes show that this system is safe as regards severe hypoglycaemia and diabetic ketoacidosis. The glycated haemoglobin may drop to levels about 7%, with CGM reports showing a time in range of 75-80%. The time above range and the time below range are within the recommended target in most of the subjects. Few studies evaluated the psychological outcomes. This system seems to be more effective than the first-generation automated insulin delivery systems. The MiniMed™ 780G has been associated with an improvement in sleep quality in subjects living with diabetes and their caregivers, along with an improvement in treatment satisfaction. Psychological distress is as reduced as the glucose control is improved. We also discuss some case reports describing particular situations in clinical practice. Finally, we think that data show that this system is a further step towards the improvement of the treatment of diabetes as concerns both metabolic and psychological outcomes.

10.
Horm Res Paediatr ; 2023 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-38104553

RESUMO

INTRODUCTION: Reducing cardiovascular risk factors (CVRFs) exposure in children and youths with type 1 diabetes (T1D) is critical for cardiovascular diseases (CVD) prevention. Long-term exposure to hyperglycaemia, measured by HbA1c, had been recognized as the main factor affecting CVRFs profile. To date, the possible association between short-term glycaemic control and variability measured by continuous glucose monitoring (CGM) metrics and CVRFs has not been explored. The aim of this study was to test the hypothesis that CGM metrics independently contribute to CVRFs exposure in children and youths with T1D. METHOD: BMI, blood pressure (BP), lipid profile, and CGM data of 895 children and youths with T1D were analysed. Binary multivariable logistic regression analyses were performed to test independent associations between CVRFs (BMI percentile>85th, LDL-c>100 mg/dL, BP>90th percentile) and CGM metrics according to sex and adjusting for confounding factors. RESULTS: In both sexes, metrics of hypoglycaemia and glycaemic variability (coefficient of variation [%CV]) positively correlated with BMI percentile. LDL-c positively correlated with mean glucose and metrics of hyperglycaemia. A negative correlation was found between LDL-c and time in range (TIR). No significant correlations were found between CGM metrics and BP percentiles. In both sexes, TIR<70% was significantly associated with LDL-c>100 mg/dL (OR 3.2 in males, 2.1 in females). In females, CV>36% was significantly associated with overweight (OR 2.1). CONCLUSIONS: CGM metrics of glycaemic control and variability were significantly associated with the risk of overweight in females and high LDL-c in both sexes.

11.
J Diabetes Sci Technol ; : 19322968231206155, 2023 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-37846755

RESUMO

BACKGROUND: Advances in diabetes technological devices led to optimization of diabetes care; however, long-lasting skin exposure to devices may be accompanied by an increasing occurrence of cutaneous reactions. METHODS: We used an open-link web-based survey to evaluate diabetes-care providers' viewpoint on prevalence, management practices, and knowledge related to skin reactions with the use of diabetes technological devices. A post hoc analysis was applied to investigate differences in the level of awareness on this topic in relation to the experience in diabetes technology. RESULTS: One hundred twenty-five responses from 39 different countries were collected. Most respondents (69%) routinely examine patients' skin at each visit. All the preventive measures are not clear and, mainly, homogenously put into clinical practice. Contact dermatitis was the most frequently reported cutaneous complication due to diabetes devices, and its most common provocative causes are not yet fully known by diabetes-care providers. Almost half of the respondents (42%) had discussed the presence of harmful allergens contained in adhesives with device manufacturers. There is general agreement on the need to strengthen knowledge on dermatological complications. CONCLUSIONS: Although diabetes-care providers are quite aware of the chance to develop skin reactions in people with diabetes using technological devices, there are still some unmet needs. Large follow-up studies and further dissemination tools are awaited to address the gaps revealed by our survey.

12.
Diabetes Res Clin Pract ; 204: 110895, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37673191

RESUMO

AIMS: Continuous glucose monitoring (CGM) can improve glucometrics in children with type 1 diabetes (T1D), and its efficacy is positively related to glucose sensor use for at least 60% of the time. We therefore investigated the relationship between CGM satisfaction as assessed by a robust questionnaire and glucose control in pediatric T1D patients. METHODS: This was a cross-sectional study of children and adolescents with T1D using CGM. The CGM Satisfaction (CGM-SAT) questionnaire was administered to patients and demographic, clinical, and glucometrics data were recorded. RESULTS: Two hundred and ten consecutively enrolled patients attending 14 Italian pediatric diabetes clinics completed the CGM-SAT questionnaire. CGM-SAT scores were not associated with age, gender, annual HbA1c, % of time with an active sensor, time above range (TAR), time below range (TBR), and coefficient of variation (CV). However, CGM satisfaction was positively correlated with time in range (TIR, p < 0.05) and negatively correlated with glycemia risk index (GRI, p < 0.05). CONCLUSIONS: CGM seems to have a positive effect on glucose control in patients with T1D. CGM satisfaction is therefore an important patient-reported outcome to assess and it is associated with increased TIR and reduced GRI.


Assuntos
Diabetes Mellitus Tipo 1 , Adolescente , Humanos , Criança , Diabetes Mellitus Tipo 1/tratamento farmacológico , Glicemia , Automonitorização da Glicemia , Estudos Transversais , Inquéritos e Questionários , Hipoglicemiantes
13.
Ital J Pediatr ; 49(1): 108, 2023 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-37653524

RESUMO

BACKGROUND: Endocan is a soluble dermatan sulfate proteoglycan (50 kDa) secreted by endothelial cells and expressed by dermal, coronary, pulmonary and adipose tissue microvasculature. It plays an important role in the pathogenesis of vascular disorders, inflammatory state, endothelium dysfunction and neoangiogenesis. Aims of the study were to compare fasting serum endocan levels between children with obesity and healthy controls and to investigate the relationships between endocan, body mass index (BMI) and other indices of cardiometabolic risk. METHODS: This single-center, observational, retrospective study included 19 pediatric patients with obesity aged 11.94 ± 0.52 years and 19 lean matched controls. Each patient underwent clinical and auxological examination and laboratory investigations including routine organs function tests and lipid profile. Homeostasis model assessment of insulin resistance (HOMA-IR) was calculated. Fasting endocan serum levels were measured using an enzyme-linked immunosorbent assay (ELISA). RESULTS: Compared to healthy subjects, serum endocan levels were found to be significantly upraised in children with obesity. Endocan resulted significantly correlated with insulin levels (rho 0.47; p = 0.04); in addition, an association with HOMA-IR values with a trend toward the statistical significance (rho 0.43; p = 0.07) was found. No significant correlation with fasting blood glucose values and lipid serum levels was demonstrated. Although not statistically significant, a correlation between endocan and the presence and grading of liver steatosis on ultrasound (rho 0.51; p = 0.08 and rho 0.51; p = 0.08, respectively) was found. CONCLUSIONS: These findings confirm the association between endothelial damage and insulin resistance in children with obesity. Endocan could be used as a biomarker of early endothelial dysfunction in children with obesity and could be a valid predictor of future cardiovascular risk in adulthood.


Assuntos
Doenças Cardiovasculares , Resistência à Insulina , Humanos , Criança , Doenças Cardiovasculares/diagnóstico , Células Endoteliais , Estudos Retrospectivos , Fatores de Risco , Biomarcadores , Fatores de Risco de Doenças Cardíacas , Lipídeos
14.
J Diabetes Sci Technol ; : 19322968231185115, 2023 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-37431949

RESUMO

BACKGROUND: The aim of this single-center observational study was to assess the real-world performance of first- and second-generation automated insulin delivery (AID) systems in a cohort of children and adolescents with type 1 diabetes over a one-year follow-up. METHODS: Demographic, anamnestic, and clinical data of the study cohort were collected at the start of automatic mode. Data on continuous glucose monitoring metrics, system settings, insulin requirements, and anthropometric parameters at three different time points (start period, six months, 12 months) were retrospectively gathered and statistically analyzed. RESULTS: Fifty-four individuals (55.6% of females) aged 7 to 18 years switching to AID therapy were included in the analysis. Two weeks after starting automatic mode, subjects using advanced hybrid closed-loop (AHCL) showed a better response than hybrid closed-loop (HCL) users in terms of time in range (P = .016), time above range 180 to 250 mg/dl (P = .022), sensor mean glucose (P = .047), and glycemia risk index (P = .012). After 12 months, AHCL group maintained better mean sensor glucose (P = .021) and glucose management indicator (P = .027). Noteworthy, both HCL and AHCL users achieved the recommended clinical targets over the entire study period. The second-generation AID system registered longer time spent with automatic mode activated and fewer shifts to manual mode at every time point (P < .001). CONCLUSIONS: Both systems showed sustained and successful glycemic outcomes in the first year of use. However, AHCL users achieved tighter glycemic targets, without an increase of hypoglycemia risk. Improved usability of the device may also have contributed to optimal glycemic outcomes by ensuring better continuity of the automatic mode activation.

15.
Diabetes Technol Ther ; 25(7): 507-512, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37155332

RESUMO

Glycemia risk index (GRI) is a novel composite metric for the evaluation of the safety of glycemic management and control. The aim of this study was to evaluate GRI and its correlations with continuous glucose monitoring (CGM) metrics by analyzing real-life CGM data in 1067 children/adolescents with type 1 diabetes (T1D) using four different treatment strategies (intermittently scanned CGM [isCGM]-multiple daily injections [MDIs]; real-time CGM-MDIs; rtCGM-insulin pump; hybrid closed-loop [HCL] therapy). GRI was positively correlated with high blood glucose index, low blood glucose index, mean glycemia, its standard deviation, coefficient of variation, and HbA1c. The four treatment strategy groups showed significantly different GRI with the lowest value in the HCL group (30.8) and the highest in the isCGM-MDIs group (68.4). These findings support the use of GRI for the assessment of the glycemic risk and the safety of specific treatment in pediatric subjects with T1D.


Assuntos
Diabetes Mellitus Tipo 1 , Criança , Humanos , Adolescente , Diabetes Mellitus Tipo 1/tratamento farmacológico , Glicemia , Hipoglicemiantes/efeitos adversos , Estudos de Coortes , Automonitorização da Glicemia , Controle Glicêmico , Insulina
16.
Ital J Pediatr ; 49(1): 58, 2023 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-37210518

RESUMO

BACKGROUND: Diabetic ketoacidosis (DKA) is one of the most alarming concerns in the management of type 1 diabetes (T1D) in pediatric age. Prevalence of DKA at the onset of diabetes ranges from 30 to 40%. In selected cases of severe DKA, admission to pediatric intensive care unit (PICU) should be considered. METHODS: This study aims to assess the prevalence of severe DKA treated in PICU in our 5-year monocentric experience. Secondary outcome of the study was to describe the main demographical and clinical features of individuals who required admission to PICU. All clinical data were collected by retrospectively reviewing the electronic medical records of children and adolescents with diabetes hospitalized in our University Hospital from January 2017 to December 2022. RESULTS: During the study period, 103 children and adolescents were newly diagnosed with T1D. Among these, 51.5% presented clinical criteria for DKA and almost 10% needed to be treated in PICU. A higher rate of new T1D diagnoses was observed in 2021, as well as episodes of severe DKA being more frequent than in previous years. Due to severe clinical manifestations of DKA, 10 subjects (9.7%) with T1D onset needed to be treated in PICU. Of these, four children were younger than 5. The great majority came from a low household income and some of them had also immigrant background. The most common complication of DKA was acute kidney injury presented by four children. Other complications were cerebral edema, papilledema and acute esophageal necrosis. A 15-year-old girl had deep vein thrombosis (DVT) that evolved into multiple organ failure leading to death. CONCLUSIONS: Our findings demonstrated that severe DKA is still quite common in children and adolescents at T1D onset, especially in some areas such as Southern Italy. Public awareness campaigns should be increasingly promoted to facilitate the recognition of early symptoms of diabetes and to reduce morbidity and mortality related to DKA.


Assuntos
Diabetes Mellitus Tipo 1 , Cetoacidose Diabética , Feminino , Adolescente , Criança , Humanos , Cetoacidose Diabética/diagnóstico , Cetoacidose Diabética/epidemiologia , Cetoacidose Diabética/terapia , Diabetes Mellitus Tipo 1/complicações , Diabetes Mellitus Tipo 1/diagnóstico , Diabetes Mellitus Tipo 1/epidemiologia , Estudos Retrospectivos , Prevalência , Unidades de Terapia Intensiva Pediátrica
18.
Pathogens ; 12(3)2023 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-36986325

RESUMO

Autoimmune-Poly-Endocrinopathy-Candidiasis-Ectodermal Dystrophy (APECED), caused by mutations in the Autoimmune Regulator (AIRE) gene, is an autosomal recessive multi-organ autoimmunity syndrome usually defined by high serum titers of type I Interferon Autoantibodies (Type 1 IFN-Abs). These antibodies have recently been found in individuals in the general population who develop life-threatening Coronavirus Disease 2019 (COVID-19), but the significance of pre-existing Type 1 IFN-Abs in APECED patients with COVID-19 remains unclear. Previous reports of COVID-19 outcomes in APECED patients have been divergent, and protective roles have been proposed for female sex, age <26 years, and immunomodulatory medications including intravenous immunoglobulin (IVIg). We report the case of a 30-year-old male APECED patient who experienced a Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) infection with mild symptoms of fatigue and headache without respiratory distress and did not require hospitalization. He received a stress dose of hydrocortisone for adrenal insufficiency and continued on his baseline medications, including subcutaneous administration of Immunoglobulins (SCIgs) for chronic inflammatory demyelinating polyneuropathy (CIDP). Mild COVID-19 in a 30-year-old male patient with APECED and pre-existing Type 1 IFN-Abs was unexpected. Younger age and management of autoimmunity may have played a role.

19.
Expert Rev Clin Immunol ; 19(5): 489-497, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36888906

RESUMO

INTRODUCTION: The COVID-19 pandemic represents an unprecedented challenge for public health worldwide, not only for the very high number of cases and deaths but also due to a wide variety of indirect consequences. Among these, the possible relationship between SARS-CoV-2 infection and type 1 diabetes (T1D) in pediatric age has aroused notable interest in the scientific community. AREAS COVERED: This perspective article aims to focus on the epidemiological trend of T1D during the pandemic, the diabetogenic role of SARS-CoV-2, and the influence of preexisting T1D on COVID-19 outcomes. EXPERT OPINION: The incidence of T1D has considerably changed during the COVID-19 pandemic, but any direct role of SARS-CoV-2 is uncertain. It is more likely that SARS-CoV-2 infection acts as an accelerator of pancreatic ß-cell immunological destruction, which is activated by known viral triggers whose spread has been abnormal during these pandemic years. Another interesting aspect to consider is the role of immunization as a potential protective factor both for T1D development and the risk of severe outcomes in already diagnosed patients. Future studies are still required to address unmet needs, including the early use of antiviral drugs to reduce the risk of metabolic decompensation in children with T1D.


Assuntos
COVID-19 , Diabetes Mellitus Tipo 1 , Humanos , Criança , SARS-CoV-2/metabolismo , Pandemias , Peptidil Dipeptidase A/metabolismo
20.
Acta Diabetol ; 60(5): 673-679, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36808474

RESUMO

AIMS: Patient-reported outcomes (PROs) are increasingly important for assessing patient satisfaction with diabetes technologies. PROs must be assessed with validated questionnaires in clinical practice and research studies. Our aim was to translate and validate the Italian version of the continuous glucose monitoring (CGM) Satisfaction (CGM-SAT) scale questionnaire. METHODS: Questionnaire validation followed MAPI Research Trust guidelines and included forward translation, reconciliation, backward translation, and cognitive debriefing. RESULTS: The final version of the questionnaire was administered to 210 patients with type 1 diabetes (T1D) and 232 parents. The completion rate was excellent, with almost 100% of items answered. The overall Cronbach's coefficient was 0.71 and 0.85 for young people (patients) and parents indicating moderate and good internal consistency, respectively. Parent-young people agreement was 0.404 (95% confidence interval: 0.391-0.417), indicating moderate agreement between the two assessments. Factor analysis identified that factors assessing the "benefits" and "hassles" of CGM accounted for 33.9% and 12.9% of score variance in young people and 29.6% and 19.8% in parents, respectively. DISCUSSION: We present the successful Italian translation and validation of the CGM-SAT scale questionnaire, which will be useful for assessing satisfaction with Italian T1D patients using CGM systems.


Assuntos
Diabetes Mellitus Tipo 1 , Humanos , Adolescente , Diabetes Mellitus Tipo 1/psicologia , Automonitorização da Glicemia/psicologia , Glicemia , Reprodutibilidade dos Testes , Inquéritos e Questionários , Itália , Satisfação Pessoal
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA