Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Codas ; 33(5): e20200100, 2021.
Artigo em Português, Inglês | MEDLINE | ID: mdl-34231667

RESUMO

PURPOSE: To evaluate the accuracy of affordable instruments for hearing screening of adults and the elderly. METHODS: This study was carried out with users of a Hearing Health Service of the Unified Health System. All were screened with the MoBASA smartphone application, the Telehealth audiometer (TH) and the electronic version of the Hearing Handicap Inventory for the Elderly - screening version - eHHIE-S. The examiners were blinded to the results of the screening tests and pure tone audiometry (PTA). Hearing impairment was considered for those with a PTA quadritonal mean greater than 40 dB in the best ear. Sensitivity, specificity and positive and negative predictive values (PPV and NPV, respectively) were calculated. The Kappa index was used as an agreement indicator between the PTA and the screening results. RESULTS: The sample consisted of 80 individuals between 18 and 94 years old (55.18 ± 20.21). In the PTA test, 21 individuals (26.25%) had typical hearing and 59 (73.75%) hearing loss. In the hearing screening tests, sensitivity, specificity, PPV and NPV values greater than 75% were observed with the MoBASA as well as in terms of sensitivity and NPV of the TH and the eHHIE-S. The TH and the eHHIE-S specificity and PPV were less than 75%. The Kappa index indicated a substantial agreement (0.6) between the PTA and the MoBASA screening results. The TH and the eHHIE-S showed regular agreement (0.3). CONCLUSION: MoBASA proved to be an accurate method for hearing screening of adults and the elderly with disabling hearing loss.


OBJETIVO: Avaliar a acurácia de instrumentos de custo acessível para triagem auditiva de adultos e idosos. MÉTODO: Este estudo foi realizado com usuários de um Serviço de Saúde Auditiva do SUS. Todos foram submetidos a triagem com o aplicativo de smartphone MoBASA, o audiômetro Telessaúde (TS) e a versão eletrônica do Questionário de Handicap da Audição para Idosos (Hearing Handicap Inventory for the Elderly ­ screening version - eHHIE-S). Os examinadores foram cegos quanto aos resultados dos testes de triagem e para os dados de audiometria de tom puro (ATP). Foram considerados com deficiência auditiva aqueles com média quadritonal na ATP maiores que 40 dB na melhor orelha. Sensibilidade, especificidade e valores preditivos positivo (VPP) e negativo (VPN) foram calculados. O índice Kappa foi usado como um indicador de concordância entre ATP e os resultados da triagem. RESULTADOS: A amostra constou de 80 indivíduos entre 18 a 94 anos (55,18 ± 20,21). Na ATP, 21 indivíduos (26,25%) apresentaram audição normal e 59 (73,75%) perda auditiva incapacitante. Nos testes de triagem auditiva observou-se valores de sensibilidade, especificidade, VPP e VPN maiores do que 75% no MoBASA e na sensibilidade e VPN do TS e eHHIE-S. Já a especificidade e VPP do TS e eHHIE-S foram inferiores a 75%. O índice Kappa indicou concordância substancial (0,6) entre o ATP e os resultados do MoBASA. No TS e eHHIE-S foi constatada regular concordância (0,3). CONCLUSÃO: O MoBASA demonstrou ser um método acurado para triagem auditiva de adultos e idosos com perda auditiva incapacitante.


Assuntos
Surdez , Perda Auditiva , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Audiometria de Tons Puros , Audição , Perda Auditiva/diagnóstico , Humanos , Programas de Rastreamento , Pessoa de Meia-Idade , Adulto Jovem
2.
Am J Audiol ; 25(3S): 288-294, 2016 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-27768190

RESUMO

PURPOSE: The purpose of this research note is to describe the development and technical validation of the Mobile Based Assistive Listening System (MoBALS), a free-of-charge smartphone-based remote microphone application. METHOD: MoBALS Version 1.0 was developed for Android (Version 2.1 or higher) and was coded with Java using Eclipse Indigo with the Android Software Development Kit. A Wi-Fi router with background traffic and 2 affordable smartphones were used for debugging and technical validation comprising, among other things, multicasting capability, data packet loss, and battery consumption. RESULTS: MoBALS requires at least 2 smartphones connected to the same Wi-Fi router for signal transmission and reception. Subscriber identity module cards or Internet connections are not needed. MoBALS can be used alone or connected to a hearing aid or cochlear implant via direct audio input. Maximum data packet loss was 99.28%, and minimum battery life was 5 hr. Other relevant design specifications and their implementation are described. CONCLUSIONS: MoBALS performed as a remote microphone with enhanced accessibility features and avoids overhead expenses by using already-available and affordable technology. The further development and technical revalidation of MoBALS will be followed by clinical evaluation with persons with hearing impairment.


Assuntos
Auxiliares de Audição , Perda Auditiva/reabilitação , Smartphone , Humanos , Auxiliares Sensoriais , Software , Percepção da Fala , Tecnologia sem Fio
3.
Int. arch. otorhinolaryngol. (Impr.) ; 17(3): 257-264, July-Sept. 2013. ilus, tab
Artigo em Inglês | LILACS | ID: lil-680069

RESUMO

The implementation of hearing screening programs can be facilitated by reducing operating costs, including the cost of equipment. The Telessaúde (TS) audiometer is a low-cost, software-based, and easy-to-use piece of equipment for conducting audiometric screening. AIM: To evaluate the TS audiometer for conducting audiometric screening. METHODS: A prospective randomized study was performed. Sixty subjects, divided into those who did not have (group A, n = 30) and those who had otologic complaints (group B, n = 30), underwent audiometric screening with conventional and TS audiometers in a randomized order. Pure tones at 25 dB HL were presented at frequencies of 500, 1000, 2000, and 4000 Hz. A "fail" result was considered when the individual failed to respond to at least one of the stimuli. Pure-tone audiometry was also performed on all participants. The concordance of the results of screening with both audiometers was evaluated. The sensitivity, specificity, and positive and negative predictive values of screening with the TS audiometer were calculated. RESULTS: For group A, 100% of the ears tested passed the screening. For group B, "pass" results were obtained in 34.2% (TS) and 38.3% (conventional) of the ears tested. The agreement between procedures (TS vs. conventional) ranged from 93% to 98%. For group B, screening with the TS audiometer showed 95.5% sensitivity, 90.4% sensitivity, and positive and negative predictive values equal to 94.9% and 91.5%, respectively. CONCLUSIONS: The results of the TS audiometer were similar to those obtained with the conventional audiometer, indicating that the TS audiometer can be used for audiometric screening...


Assuntos
Adolescente , Adulto Jovem , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Audição , Testes Auditivos , Perda Auditiva/epidemiologia , Brasil
4.
Int Arch Otorhinolaryngol ; 17(3): 257-64, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27053951

RESUMO

INTRODUCTION: The implementation of hearing screening programs can be facilitated by reducing operating costs, including the cost of equipment. The Telessaúde (TS) audiometer is a low-cost, software-based, and easy-to-use piece of equipment for conducting audiometric screening. AIM: To evaluate the TS audiometer for conducting audiometric screening. METHODS: A prospective randomized study was performed. Sixty subjects, divided into those who did not have (group A, n = 30) and those who had otologic complaints (group B, n = 30), underwent audiometric screening with conventional and TS audiometers in a randomized order. Pure tones at 25 dB HL were presented at frequencies of 500, 1000, 2000, and 4000 Hz. A "fail" result was considered when the individual failed to respond to at least one of the stimuli. Pure-tone audiometry was also performed on all participants. The concordance of the results of screening with both audiometers was evaluated. The sensitivity, specificity, and positive and negative predictive values of screening with the TS audiometer were calculated. RESULTS: For group A, 100% of the ears tested passed the screening. For group B, "pass" results were obtained in 34.2% (TS) and 38.3% (conventional) of the ears tested. The agreement between procedures (TS vs. conventional) ranged from 93% to 98%. For group B, screening with the TS audiometer showed 95.5% sensitivity, 90.4% sensitivity, and positive and negative predictive values equal to 94.9% and 91.5%, respectively. CONCLUSIONS: The results of the TS audiometer were similar to those obtained with the conventional audiometer, indicating that the TS audiometer can be used for audiometric screening.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA