1.
Nat Commun ; 15(1): 4481, 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38802397

RESUMO

Retinal degeneration, a leading cause of irreversible low vision and blindness globally, can be partially addressed by retina prostheses which stimulate remaining neurons in the retina. However, existing electrode-based treatments are invasive, posing substantial risks to patients and healthcare providers. Here, we introduce a completely noninvasive ultrasonic retina prosthesis, featuring a customized ultrasound two-dimensional array which allows for simultaneous imaging and stimulation. With synchronous three-dimensional imaging guidance and auto-alignment technology, ultrasonic retina prosthesis can generate programmed ultrasound waves to dynamically and precisely form arbitrary wave patterns on the retina. Neuron responses in the brain's visual center mirrored these patterns, evidencing successful artificial vision creation, which was further corroborated in behavior experiments. Quantitative analysis of the spatial-temporal resolution and field of view demonstrated advanced performance of ultrasonic retina prosthesis and elucidated the biophysical mechanism of retinal stimulation. As a noninvasive blindness prosthesis, ultrasonic retina prosthesis could lead to a more effective, widely acceptable treatment for blind patients. Its real-time imaging-guided stimulation strategy with a single ultrasound array, could also benefit ultrasound neurostimulation in other diseases.


Assuntos
Cegueira , Retina , Próteses Visuais , Retina/diagnóstico por imagem , Retina/fisiologia , Animais , Cegueira/terapia , Cegueira/fisiopatologia , Degeneração Retiniana/terapia , Degeneração Retiniana/diagnóstico por imagem , Ondas Ultrassônicas , Humanos , Neurônios/fisiologia , Ultrassonografia/métodos , Visão Ocular/fisiologia
2.
Nat Commun ; 15(1): 4017, 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38740759

RESUMO

Ultrasound-driven bioelectronics could offer a wireless scheme with sustainable power supply; however, current ultrasound implantable systems present critical challenges in biocompatibility and harvesting performance related to lead/lead-free piezoelectric materials and devices. Here, we report a lead-free dual-frequency ultrasound implants for wireless, biphasic deep brain stimulation, which integrates two developed lead-free sandwich porous 1-3-type piezoelectric composite elements with enhanced harvesting performance in a flexible printed circuit board. The implant is ultrasonically powered through a portable external dual-frequency transducer and generates programmable biphasic stimulus pulses in clinically relevant frequencies. Furthermore, we demonstrate ultrasound-driven implants for long-term biosafety therapy in deep brain stimulation through an epileptic rodent model. With biocompatibility and improved electrical performance, the lead-free materials and devices presented here could provide a promising platform for developing implantable ultrasonic electronics in the future.


Assuntos
Estimulação Encefálica Profunda , Tecnologia sem Fio , Estimulação Encefálica Profunda/instrumentação , Estimulação Encefálica Profunda/métodos , Animais , Tecnologia sem Fio/instrumentação , Ratos , Eletrodos Implantados , Epilepsia/terapia , Masculino , Próteses e Implantes , Ratos Sprague-Dawley , Transdutores , Desenho de Equipamento , Ondas Ultrassônicas
3.
Sci Adv ; 10(22): eadn0260, 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38820150

RESUMO

Biodegradable piezoelectric devices hold great promise in on-demand transient bioelectronics. Existing piezoelectric biomaterials, however, remain obstacles to the development of such devices due to difficulties in large-scale crystal orientation alignment and weak piezoelectricity. Here, we present a strategy for the synthesis of optimally orientated, self-aligned piezoelectric γ-glycine/polyvinyl alcohol (γ-glycine/PVA) films via an ultrasound-assisted process, guided by density functional theory. The first-principles calculations reveal that the negative piezoelectric effect of γ-glycine originates from the stretching and compression of glycine molecules induced by hydrogen bonding interactions. The synthetic γ-glycine/PVA films exhibit a piezoelectricity of 10.4 picocoulombs per newton and an ultrahigh piezoelectric voltage coefficient of 324 × 10-3 volt meters per newton. The biofilms are further developed into flexible, bioresorbable, wireless piezo-ultrasound electrotherapy devices, which are demonstrated to shorten wound healing by ~40% and self-degrade in preclinical wound models. These encouraging results offer reliable approaches for engineering piezoelectric biofilms and developing transient bioelectronics.


Assuntos
Biofilmes , Álcool de Polivinil , Tecnologia sem Fio , Álcool de Polivinil/química , Animais , Glicina/química , Cicatrização , Materiais Biocompatíveis/química , Terapia por Estimulação Elétrica/instrumentação , Terapia por Estimulação Elétrica/métodos
4.
J Neurosci Methods ; 405: 110095, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38403001

RESUMO

BACKGROUND: The retinotopic map property of the superior colliculus (SC) is a reliable indicator of visual functional changes in rodents. Electrophysiological mapping of the SC using a single electrode has been employed for measuring visual function in rat and mouse disease models. Single electrode mapping is highly laborious requiring long-term exposure to the SC surface and prolonged anesthetic conditions that can adversely affect the mapping data. NEW METHOD: To avoid the above-mentioned issues, we fabricated a fifty-six (56) electrode multi-electrode array (MEA) for rapid and reliable visual functional mapping of the SC. Since SC is a dome-shaped structure, the array was made of electrodes with dissimilar tip lengths to enable simultaneous and uniform penetration of the SC. RESULTS: SC mapping using the new MEA was conducted in retinal degenerate (RD) Royal College of Surgeons (RCS) rats and rats with focal retinal damage induced by green diode laser. For SC mapping, the MEA was advanced into the SC surface and the visual activities were recorded during full-filed light stimulation of the eye. Based on the morphological examination, the MEA electrodes covered most of the exposed SC area and penetrated the SC surface at a relatively uniform depth. MEA mapping in RCS rats (n=9) demonstrated progressive development of a scotoma in the SC that corresponded to the degree of photoreceptor loss. MEA mapping in the laser damaged rats demonstrated the presence of a scotoma in the SC area that corresponded to the location of retinal laser injury. COMPARISON WITH EXISTING METHODS AND CONCLUSIONS: The use of MEA for SC mapping is advantageous over single electrode recording by enabling faster recordings and reducing anesthesia time. This study establishes the feasibility of the MEA technique for rapid and efficient SC mapping, particularly advantageous for evaluating therapeutic effects in retinal degenerate rat disease models.


Assuntos
Escotoma , Colículos Superiores , Humanos , Ratos , Animais , Camundongos , Colículos Superiores/fisiologia , Retina/fisiologia , Luz , Eletrodos
5.
Artigo em Inglês | MEDLINE | ID: mdl-37792653

RESUMO

An ultrasound concave 2-D ring array transducer was designed for applications in visual stimulation of the retina with a long-term goal to restore vision in individuals with intact neurons but suffering blindness due to retinopathies. The array was synthesized and has a frequency of 20 MHz (0.075-mm wavelengths in water), 18-mm focal length (the curvature of the concave array), 1004 elements (with a pitch of 4.0 wavelengths), and inner and outer diameters of 9 and 14 mm, respectively. Wave patterns produced with the array at the focal distance were simulated. Results show that the wave patterns obtained can achieve a full-width-at-half-maximum (FWHM) resolution of 0.147 mm that is very close to the FWHM diffraction limit (0.136 mm). In addition, a scaled experiment at a lower frequency of 2.5 MHz was performed. The result is very close to those obtained with the simulations.


Assuntos
Retina , Transdutores , Humanos , Desenho de Equipamento , Ultrassonografia/métodos , Imagens de Fantasmas , Retina/diagnóstico por imagem
6.
Nat Commun ; 14(1): 6477, 2023 10 14.
Artigo em Inglês | MEDLINE | ID: mdl-37838708

RESUMO

Bionic multifunctional structural materials that are lightweight, strong, and perceptible have shown great promise in sports, medicine, and aerospace applications. However, smart monitoring devices with integrated mechanical protection and piezoelectric induction are limited. Herein, we report a strategy to grow the recyclable and healable piezoelectric Rochelle salt crystals in 3D-printed cuttlebone-inspired structures to form a new composite for reinforcement smart monitoring devices. In addition to its remarkable mechanical and piezoelectric performance, the growth mechanisms, the recyclability, the sensitivity, and repairability of the 3D-printed Rochelle salt cuttlebone composite were studied. Furthermore, the versatility of composite has been explored and applied as smart sensor armor for football players and fall alarm knee pads, focusing on incorporated mechanical reinforcement and electrical self-sensing capabilities with data collection of the magnitude and distribution of impact forces, which offers new ideas for the design of next-generation smart monitoring electronics in sports, military, aerospace, and biomedical engineering.


Assuntos
Esportes , Dispositivos Eletrônicos Vestíveis , Eletricidade , Impressão Tridimensional
7.
Bioengineering (Basel) ; 10(5)2023 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-37237647

RESUMO

The optic nerve is the second cranial nerve (CN II) that connects and transmits visual information between the retina and the brain. Severe damage to the optic nerve often leads to distorted vision, vision loss, and even blindness. Such damage can be caused by various types of degenerative diseases, such as glaucoma and traumatic optic neuropathy, and result in an impaired visual pathway. To date, researchers have not found a viable therapeutic method to restore the impaired visual pathway; however, in this paper, a newly synthesized model is proposed to bypass the damaged portion of the visual pathway and set up a direct connection between a stimulated visual input and the visual cortex (VC) using Low-frequency Ring-transducer Ultrasound Stimulation (LRUS). In this study, by utilizing and integrating various advanced ultrasonic and neurological technologies, the following advantages are achieved by the proposed LRUS model: 1. This is a non-invasive procedure that uses enhanced sound field intensity to overcome the loss of ultrasound signal due to the blockage of the skull. 2. The simulated visual signal generated by LRUS in the visual-cortex-elicited neuronal response in the visual cortex is comparable to light stimulation of the retina. The result was confirmed by a combination of real-time electrophysiology and fiber photometry. 3. VC showed a faster response rate under LRUS than light stimulation through the retina. These results suggest a potential non-invasive therapeutic method for restoring vision in optic-nerve-impaired patients using ultrasound stimulation (US).

8.
Nat Commun ; 14(1): 2418, 2023 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-37105973

RESUMO

The performance of ultrasonic transducers is largely determined by the piezoelectric properties and geometries of their active elements. Due to the brittle nature of piezoceramics, existing processing tools for piezoelectric elements only achieve simple geometries, including flat disks, cylinders, cubes and rings. While advances in additive manufacturing give rise to free-form fabrication of piezoceramics, the resultant transducers suffer from high porosity, weak piezoelectric responses, and limited geometrical flexibility. We introduce optimized piezoceramic printing and processing strategies to produce highly responsive piezoelectric microtransducers that operate at ultrasonic frequencies. The 3D printed dense piezoelectric elements achieve high piezoelectric coefficients and complex architectures. The resulting piezoelectric charge constant, d33, and coupling factor, kt, of the 3D printed piezoceramic reach 583 pC/N and 0.57, approaching the properties of pristine ceramics. The integrated printing of transducer packaging materials and 3D printed piezoceramics with microarchitectures create opportunities for miniaturized piezoelectric ultrasound transducers capable of acoustic focusing and localized cavitation within millimeter-sized channels, leading to miniaturized ultrasonic devices that enable a wide range of biomedical applications.

9.
IEEE Trans Biomed Eng ; 70(1): 135-143, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35759590

RESUMO

OBJECTIVE: There is uncertainty about deep vein thrombosis standard treatment as thrombus stiffness alters each case. Here, we investigated thrombus' stiffness of different compositions and ages using shear wave elastography (SWE). We then studied the effectiveness of ultrasound-thrombolysis on different thrombus compositions. METHODS: Shear waves generated through mechanical shaker and traveled along thrombus of different hematocrit (HCT) levels, whereas 18-MHz ultrasound array used to detect wave propagation. Thrombus' stiffness was identified by the shear wave speed (SWS). In thrombolysis, a 3.2 MHz focused transducer was applied to different thrombus compositions using different powers. The thrombolysis rate was defined as the percentage of weight loss. RESULTS: The estimated average SWS of 20%, 40%, and 60% HCT thrombus were 0.75 m/s, 0.44 m/s, and 0.32 m/s, respectively. For Thrombolysis, the percentage weight loss at 8 MPa Negative pressure for the same HCT groups were 23.1%, 35.29%, and 39.66% respectively. CONCLUSION: SWS is inversely related to HCT level and positively related to thrombus age. High HCT thrombus had higher weight loss compared to low HCT. However, the difference between 20% and 40% HCT was more significant than between 40% and 60% HCT in both studies. Our results suggest that thrombus with higher SWS require more power to achieve the same thrombolysis rate as thrombus with lower SWS. SIGNIFICANCE: Characterizing thrombus elastic property undergoing thrombolysis enables evaluation of ultrasound efficacy for fractionating thrombus and reveals the appropriate ultrasound parameters selection to achieve a certain thrombolysis rate in the case of a specific thrombus stiffness.


Assuntos
Técnicas de Imagem por Elasticidade , Trombose , Humanos , Técnicas de Imagem por Elasticidade/métodos , Ultrassonografia/métodos , Elasticidade , Trombose/diagnóstico por imagem , Trombose/tratamento farmacológico , Terapia Trombolítica
10.
Artigo em Inglês | MEDLINE | ID: mdl-36343006

RESUMO

Ultrasound neuromodulation is an emerging technology. A significant amount of effort has been devoted to investigating the feasibility of noninvasive ultrasound retinal stimulation. Recent studies have shown that ultrasound can activate neurons in healthy and degenerated retinas. Specifically, high-frequency ultrasound can evoke localized neuron responses and generate patterns in visual circuits. In this review, we recapitulate pilot studies on ultrasound retinal stimulation, compare it with other neuromodulation technologies, and discuss its advantages and limitations. An overview of the opportunities and challenges to develop a noninvasive retinal prosthesis using high-frequency ultrasound is also provided.


Assuntos
Retina , Próteses Visuais , Retina/diagnóstico por imagem , Retina/fisiologia , Ultrassonografia
11.
Photoacoustics ; 28: 100417, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36299642

RESUMO

Combining focused optical excitation and high-frequency ultrasound detection, optical-resolution photoacoustic microscopy (OR-PAM) can provide micrometer-level spatial resolution with millimeter-level penetration depth and has been employed in a variety of biomedical applications. However, it remains a challenge for OR-PAM to achieve a high imaging speed and a large field of view at the same time. In this work, we report a new approach to implement high-speed wide-field OR-PAM, using a cylindrically-focused transparent ultrasound transducer (CFT-UT). The CFT-UT is made of transparent lithium niobate coated with indium-tin-oxide as electrodes. A transparent cylindrical lens is attached to the transducer surface to provide an acoustic focal line with a length of 9 mm. The excitation light can pass directly through the CFT-UT from the above and thus enables a reflection imaging mode. High-speed imaging is achieved by fast optical scanning of the focused excitation light along the CFT-UT focal line. With the confocal alignment of the optical excitation and acoustic detection, a relatively high detection sensitivity is maintained over the entire scanning range. The CFT-UT-based OR-PAM system has achieved a cross-sectional frame rate of 500 Hz over the scanning range of 9 mm. We have characterized the system's performance on phantoms and demonstrated its application on small animal models in vivo. We expect the new CFT-UT-based OR-PAM will find matched biomedical applications that need high imaging speed over a large field of view.

12.
Artigo em Inglês | MEDLINE | ID: mdl-36315528

RESUMO

High element density and strict constraints of the element's size have significantly limited the design and fabrication of 2-D ultrasonic arrays, especially fully sampled 2-D arrays. Recently, 3-D printing technology has been one of the most rapidly developing fields. Along with the great progress of 3-D printing technology, complex and detailed 3-D structures have become readily available with a short iteration cycle, which allows us to reduce the complexity of routing and helps to ameliorate assembly problems in 2-D ultrasound array fabrication. In this work, we designed and fabricated 2-D ultrasound arrays for an array of applications with a pitch-shifting interposer, which allowed us to fit different array designs with the same circuit design and significantly reduce the requirements in routing and connection for 2-D array fabrication at frequencies from 4 to 10 MHz. Results demonstrated that this design would make 2-D arrays more available and affordable.


Assuntos
Transdutores , Ultrassom , Desenho de Equipamento , Ultrassonografia/métodos
13.
Micromachines (Basel) ; 13(9)2022 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-36144157

RESUMO

Argus II retinal prosthesis is the US Food and Drug Administration (FDA) approved medical device intended to restore sight to a patient's blind secondary to retinal degeneration (i.e., retinitis pigmentosa). However, Argus II and most reported retinal prostheses require invasive surgery to implant electrodes in the eye. Recent studies have shown that focused ultrasound can be developed into a non-invasive retinal prosthesis technology. Ultrasound energy focused on retinal neurons can trigger the activities of retinal neurons with high spatial-temporal resolution. This paper introduces a novel design and simulation of a ring array transducer that could be used as non-invasive ultrasonic retinal stimulation. The array transducer is designed in the shape of a racing ring with a hemisphere surface that mimics a contact lens to acoustically couple with the eye via the tear film and directs the ultrasound to avoid the high acoustic absorption from the crystalline lens. We will describe the design methods and simulation of the two-dimensional pattern stimulation. Finally, compared with other existing retinal prostheses, we show that the ultrasound ring array is practical and safe and could be potentially used as a non-invasive retinal prosthesis.

14.
Nat Commun ; 13(1): 3853, 2022 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-35788594

RESUMO

Electronic visual prostheses, or biomimetic eyes, have shown the feasibility of restoring functional vision in the blind through electrical pulses to initiate neural responses artificially. However, existing visual prostheses predominantly use wired connections or electromagnetic waves for powering and data telemetry, which raises safety concerns or couples inefficiently to miniaturized implant units. Here, we present a flexible ultrasound-induced retinal stimulating piezo-array that can offer an alternative wireless artificial retinal prosthesis approach for evoking visual percepts in blind individuals. The device integrates a two-dimensional piezo-array with 32-pixel stimulating electrodes in a flexible printed circuit board. Each piezo-element can be ultrasonically and individually activated, thus, spatially reconfigurable electronic patterns can be dynamically applied via programmable ultrasound beamlines. As a proof of concept, we demonstrate the ultrasound-induced pattern reconstruction in ex vivo murine retinal tissue, showing the potential of this approach to restore functional, life-enhancing vision in people living with blindness.


Assuntos
Próteses Visuais , Animais , Biomimética , Cegueira/terapia , Humanos , Camundongos , Retina/diagnóstico por imagem , Retina/fisiologia , Retina/cirurgia , Visão Ocular
15.
Mater Horiz ; 9(8): 2180-2190, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35686946

RESUMO

Implantable medical electronics (IMEs) are now becoming increasingly prevalent for diagnostic and therapeutic purposes. Despite extensive efforts, a primary challenge for IMEs is reliable wireless power and communication to provide well-controlled, therapeutically relevant effects. Ultrasonic energy transfer and communication (UETC) employing traveling ultrasound waves to transmit energy has emerged as a promising wireless strategy for IMEs. Nevertheless, conventional UETC systems are rigid, bulky, and based on toxic lead-based piezoelectric materials, raising efficiency and safety concerns. Here, we present a novel transcutaneous UETC system based on a two-dimensional flexible lead-free piezoelectric array (f-LFPA) that hybridizes high-performance (piezoelectric coefficient d33 ≈ 503 pC N-1) (K,Na)NbO3-based eco-friendly piezo-units with soft structural components. The newly developed lead-free piezo-unit exhibits submicron ferroelectric domains and superior energy harvesting figures of merit (d33g33 ≈ 20 000 × 10-15 m2 N-1), resulting in the prepared f-LFPA demonstrating a high output voltage of 22.4 V, a power density of 0.145 W cm-2, and a signal-to-noise ratio of more than 30 dB within the FDA safety limits, while maintaining the flexibility for wide-angle receiving. Further ex vivo experiment demonstrates the adequate power supply capabilities of the f-LFPA and its possible application in future implantable eco-friendly bioelectronics for diagnostics, therapy, and real-time monitoring.


Assuntos
Fontes de Energia Elétrica , Ultrassom , Transferência de Energia , Próteses e Implantes
16.
Neurobiol Dis ; 170: 105756, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35584727

RESUMO

BACKGROUND: Few treatments exist for the cognitive symptoms of schizophrenia. Pharmacological agents resulting in glutamate N-methyl-d-aspartate (NMDA) receptor hypofunction, such as MK-801, mimic many of these symptoms and disrupt neural activity. Recent evidence suggests that deep brain stimulation (DBS) of the medial septal nucleus (MSN) can modulate medial prefrontal cortex (mPFC) and hippocampal activity and improve spatial memory. OBJECTIVE: Here, we examine the effects of acute MK-801 administration on oscillatory activity within the septohippocampal circuit and behavior. We also evaluate the potential for MSN stimulation to improve cognitive behavioral measures following MK-801 administration. METHODS: 59 Sprague Dawley male rats received either acute intraperitoneal (IP) saline vehicle injections or MK-801 (0.1 mg/kg). Theta (5-12 Hz), low gamma (30-50 Hz) and high frequency oscillatory (HFO) power were analyzed in the mPFC, MSN, thalamus and hippocampus. Rats underwent MSN theta (7.7 Hz), gamma (100 Hz) or no stimulation during behavioral tasks (Novel object recognition (NOR), elevated plus maze, Barnes maze (BM)). RESULTS: Injection of MK-801 resulted in frequency-specific changes in oscillatory activity, decreasing theta while increasing HFO power. Theta, but not gamma, stimulation enhanced the anxiolytic effects of MK-801 on the elevated plus maze. While MK-801 treated rats exhibited spatial memory deficits on the Barnes maze, those that also received MSN theta, but not gamma, stimulation found the escape hole sooner. CONCLUSIONS: These findings demonstrate that acute MK-801 administration leads to altered neural activity in the septohippocampal circuit and impaired spatial memory. Further, these findings suggest that MSN theta-frequency stimulation improves specific spatial memory deficits and may be a possible treatment for cognitive impairments caused by NMDA hypofunction.


Assuntos
Estimulação Encefálica Profunda , Núcleos Septais , Animais , Estimulação Encefálica Profunda/métodos , Maleato de Dizocilpina/farmacologia , Hipocampo , Masculino , Transtornos da Memória/induzido quimicamente , Transtornos da Memória/terapia , N-Metilaspartato/farmacologia , Ratos , Ratos Sprague-Dawley , Memória Espacial
17.
Artigo em Inglês | MEDLINE | ID: mdl-35468061

RESUMO

Ultrasound single-beam acoustic tweezer system has attracted increasing attention in the field of biomechanics. Cell biomechanics play a pivotal role in leukemia cell functions. To better understand and compare the cell mechanics of the leukemia cells, herein, we fabricated an acoustic tweezer system in-house connected with a 50-MHz high-frequency cylinder ultrasound transducer. Selected leukemia cells (Jurkat, K562, and MV-411 cells) were cultured, trapped, and manipulated by high-frequency ultrasound single beam, which was transmitted from the ultrasound transducer without contacting any cells. The relative deformability of each leukemia cell was measured, characterized, and compared, and the leukemia cell (Jurkat cell) gaining the highest deformability was highlighted. Our results demonstrate that the high-frequency ultrasound single beam can be utilized to manipulate and characterize leukemia cells, which can be applied to study potential mechanisms in the immune system and cell biomechanics in other cell types.


Assuntos
Acústica , Leucemia , Humanos , Leucemia/diagnóstico por imagem , Ultrassonografia/métodos
18.
Research (Wash D C) ; 2022: 9840574, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35169712

RESUMO

Flame-retardant and thermal management structures have attracted great attention due to the requirement of high-temperature exposure in industrial, aerospace, and thermal power fields, but the development of protective fire-retardant structures with complex shapes to fit arbitrary surfaces is still challenging. Herein, we reported a rotation-blade casting-assisted 3D printing process to fabricate nacre-inspired structures with exceptional mechanical and flame-retardant properties, and the related fundamental mechanisms are studied. 3-(Trimethoxysilyl)propyl methacrylate (TMSPMA) modified boron nitride nanoplatelets (BNs) were aligned by rotation-blade casting during the 3D printing process to build the "brick and mortar" architecture. The 3D printed structures are more lightweight, while having higher fracture toughness than the natural nacre, which is attributed to the crack deflection, aligned BN (a-BNs) bridging, and pull-outs reinforced structures by the covalent bonding between TMSPMA grafted a-BNs and polymer matrix. Thermal conductivity is enhanced by 25.5 times compared with pure polymer and 5.8 times of anisotropy due to the interconnection of a-BNs. 3D printed heat-exchange structures with vertically aligned BNs in complex shapes were demonstrated for efficient thermal control of high-power light-emitting diodes. 3D printed helmet and armor with a-BNs show exceptional mechanical and fire-retardant properties, demonstrating integrated mechanical and thermal protection.

19.
BME Front ; 2022: 9829316, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-37850175

RESUMO

Objective. Retinal degeneration involving progressive deterioration and loss of function of photoreceptors is a major cause of permanent vision loss worldwide. Strategies to treat these incurable conditions incorporate retinal prostheses via electrically stimulating surviving retinal neurons with implanted devices in the eye, optogenetic therapy, and sonogenetic therapy. Existing challenges of these strategies include invasive manner, complex implantation surgeries, and risky gene therapy. Methods and Results. Here, we show that direct ultrasound stimulation on the retina can evoke neuron activities from the visual centers including the superior colliculus and the primary visual cortex (V1), in either normal-sighted or retinal degenerated blind rats in vivo. The neuron activities induced by the customized spherically focused 3.1 MHz ultrasound transducer have shown both good spatial resolution of 250 µm and temporal resolution of 5 Hz in the rat visual centers. An additional customized 4.4 MHz helical transducer was further implemented to generate a static stimulation pattern of letter forms. Conclusion. Our findings demonstrate that ultrasound stimulation of the retina in vivo is a safe and effective approach with high spatiotemporal resolution, indicating a promising future of ultrasound stimulation as a novel and noninvasive visual prosthesis for translational applications in blind patients.

20.
Exp Biol Med (Maywood) ; 247(6): 519-526, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34648358

RESUMO

Current treatments for meibomian gland dysfunction have several limitations, creating a necessity for other advanced treatment options. The purpose of this study is to determine the effectiveness of focused ultrasound stimulation for the treatment of dry eye disease caused by meibomian gland dysfunction. An in vivo study of nine Dutch Belted rabbits was conducted with focused ultrasound stimulation of the meibomian glands. A customized line-focused ultrasonic transducer was designed for treatment. Fluorescein imaging, Schirmer's test, and Lipiview II ocular interferometer were used to quantify outcomes from three aspects: safety, tear production, and lipid layer thickness. Both tear secretion and lipid layer thickness improved following ultrasound treatment. Five to 10 min after the ultrasound treatment, the mean values of lipid layer thickness increased from 55.33 ± 11.15 nm to 95.67 ± 22.77 nm (p < 0.05), while the mean values measured with the Schirmer's test increased from 2.0 ± 2.3 to 7.2 ± 4.3 (p < 0.05). Positive effects lasted more than three weeks. Adverse events such as redness, swelling, and mild burn, occurred in two rabbits in preliminary experiments when the eyelids sustained a temperature higher than 42°C. No serious adverse events were found. The results suggest that ultrasound stimulation of meibomian glands can improve both tear production and lipid secretion. Ultimately, ultrasound stimulation has the potential to be an option for the treatment of evaporative dry eye disease caused by meibomian gland dysfunction.


Assuntos
Síndromes do Olho Seco , Disfunção da Glândula Tarsal , Animais , Síndromes do Olho Seco/terapia , Lipídeos , Glândulas Tarsais , Coelhos , Lágrimas/fisiologia