Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
Trauma Surg Acute Care Open ; 9(1): e001197, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38510532

RESUMO

Background: With the increasing prevalence of electric scooters, a concomitant increase in the number of specific injuries, emergency department (ED) admissions and hospital admissions have been reported. Objectives: Analyze patient flow changes in the ED with a focus on e-scooter-related injuries through a case series and a comparison with the contemporary literature. Data sources: A systematic literature review was performed on Medline/PubMed and Embase using terms related to the topic.Data collected from two-wheeled vehicle trauma patients at our Italian ED from May 1 to October 31, 2021, were analyzed for the case series. Study eligibility criteria: Studies were included if they evaluated populations with an e-scooter-related injury referred to the ED with precise localization and nature of the injury reported. Participants and interventions: Data collected from the literature studies and from our case series included overall ED patient numbers, patient demographics, injury mechanism, location of the injury, discharge diagnosis, and performance of surgery. Study appraisal and synthesis methods: All studies were checked in order to establish the coherence with the purposes of this review. Data from the contemporary literature and from this case series were compared. Results: During a 6-month period, 280 patients had e-scooter injuries, resulting in 292 traumas, including 123 fractures, primarily in the elbow. Surgical intervention was necessary for 28 patients. The review included nine papers, highlighting that injuries to the upper and lower extremities and head were frequent in e-scooter-related incidents. The upper extremities were the most common fracture location. Limitations: The study is a retrospective, single-center study without a comparison group, focusing exclusively on orthopedic injuries. Conclusions or implications of key findings: The prevalence of electric scooters, which offer an affordable and eco-friendly mode of transport, is steadily increasing. It is important to focus on injury risk mitigation through effective public health policies, thereby lowering costs to society.

2.
Arthrosc Sports Med Rehabil ; 6(2): 100865, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38328531

RESUMO

Purpose: To assess and quantify the improvement in visualization of humeral insertion of the medial collateral ligament (MCL) using a 70° scope compared with a 30° scope during elbow arthroscopy. Methods: Twenty patients undergoing elbow arthroscopy for different pathologic conditions were enrolled in this single-center study. Visualization of the medial gutter of the elbow was evaluated by using both the 70° and the 30°scope. During the procedure, a needle was inserted at 45° with respect to the axis of the forearm, directed toward the intra-articular humeral emergence of the MCL. Four areas were established: the body (Z1), the lanceolate part (Z2), the tip of the needle (Z3), and the medial portion of the trochlea (Z4). The visible areas during arthroscopy using 2 different scopes were collected. Results: The 70° scope allowed the detection of the first 3 areas in all patients (Z1, Z2, and Z3) and the visualization of the last area (Z4) in 19 patients (95%). On the other hand, the 30° scope allowed the detection of Z1 in 85% of patients, Z2 in 60% of patients, and Z3 in only 5% of patients. The medial portion of the trochlea was never visualized with the 30° scope. These findings were statistically significant. Conclusions: The 70° scope improves visualization of the medial elbow compartment during elbow arthroscopy compared to the 30° scope, enhancing the extent of joint visualization and potentially permitting the detection of otherwise missed injuries in the difficult-to-reach areas of the joint. Level of Evidence: Level II, diagnostic, prospective, cohort study.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38295935

RESUMO

INTRODUCTION: Elbow dislocation is frequently associated with bony and osteochondral postero-lateral capitellar lesions that are often under-reported. We aim to examine the radiological signs of postero-lateral lesions on Computer Tomography (CT) . METHODS: A retrospective analysis of CT scans was performed. Patients were classified into 4 groups: 1) simple elbow dislocation, 2) elbow dislocation with a fracture of the coronoid tip, 3) elbow dislocation with coronoid tip fracture and a radial head fracture inferior or equal to the anterior third, 4) terrible triad defined as elbow dislocation with concomitant coronoid and a radial head fracture with a more important involvement. Patients with a more complex fracture pattern were excluded. The presence of POstero Lateral Engagement of Soft Tissue And the Radial head (POLESTAR) patterns was analyzed and subclassified as impaction type or fragmentation type. RESULTS: 51 CT scans met the inclusion criteria. POLESTAR lesions were identified in 48 cases (94%): 46% impaction type and 54% fragmentation type POLESTAR. Analyzing patients from grade 1 to 4, impaction type POLESTAR was found respectively from 40% to 57%, while fragmentation type was present from 60% to 43%. CONCLUSIONS: This study shows a high incidence of POLESTAR lesions (94%) that can be present as impaction type or fragmentation type. Based on our preliminary results, impaction type is more common in Grades 3 and 4, while fragmentation type is more frequent in grades 1 or 2.

4.
J Exp Orthop ; 10(1): 25, 2023 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-36918478

RESUMO

PURPOSE: Traumatic elbow dislocation is the second most frequent joint dislocation, even though the elbow is a congruent and stable joint. Individual variability in anatomical congruence of the elbow and how it relates to simple or complex instability has rarely been studied in the literature; we hypothesized that a greater articular coverage by the humeral trochlea would be more likely to result in complex dislocation. The aim of this study is to analyze trochlear morphology in simple (SED) and complex elbow dislocation (CED), to assess whether the degree of humeroulnar joint congruence influences the incidence of coronoid fractures in elbow dislocation. The secondary goal is to evaluate the association between trochlear morphology and coronoid fracture pattern. METHODS: All the elbow CT scans of the hospital server were retrospectively analyzed. 62 patients were enrolled and so divided in 2 groups: SED and CED with isolated coronoid fracture. Patients who were skeletally immature, presented with other concomitant elbow fractures, or who previously underwent elbow surgery were excluded. The CT scans were performed after closed reduction and prior to further treatment. Coronoid fracture pattern was classified on CT scan according to Regan-Morrey and O'Driscoll classifications; "grade 0" was assigned to SED. Trochlear coverage was measured and expressed as three angles (anterior, posterior, and distal) and their width/depth ratios. Measurements were taken by four different readers and the assessment was repeated after 15 days. RESULTS: No statistically significant difference was found between humeral trochlear morphology of SED and CED patients. There was no association between morphometric measurements and coronoid fracture pattern. The results are strengthened by a good intra- and inter-reader reproducibility of the CT analysis protocol. CONCLUSIONS: Our study is the first to evaluate the impact of trochlear morphology on elbow instability. Considering the results, other variables may have a greater impact on coronoid bone damage, such as trauma energy or ligamentous hyperlaxity: in particular, we believe that the capsuloligamentous structures of the elbow might contribute in a preponderant way to articular stability. The CT analysis protocol gave excellent results: reproducible, accurate and easy to perform. LEVEL OF EVIDENCE: III.

5.
Indian J Orthop ; 56(8): 1403-1409, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35928660

RESUMO

Background: The anterior tibial translation (ATT) in case of Anterior Cruciate Ligament (ACL) tear can lead to dynamic alterations of the extensor apparatus biomechanics. The aim of this study is to evaluate the dynamic effect of isolated ACL deficiency on patellar height. The hypothesis is that the ATT of ACL-insufficient knees dynamically reduces patellar height. Methods: Skeletally mature patients who underwent ACL reconstruction using hamstring graft between January and December 2018 were included in this study. The Posterior Tibial Slope (PTS), Caton-Deschamps (CDI), modified Insall-Salvati (MISI), and Blackburne-Peel (BPI) indices were calculated in standard lateral and TELOS X-rays. The mean of the measurements calculated between two observers was used to compare these parameters. Results: 95 patients (M: 57; F: 38; 95 knees) were included in the study with a mean age of 31.8 years (16-56 years old). Significant patellar height reduction (CDI: 0.11 [- 0.32; 0.31]; MISI: 0.09 [- 0.66; 0.30]) was reported in TELOS compared with standard lateral knee radiography (p < 0.001). 20.0% of the study knees reported an abnormal CDI and 84.2% (16/19 knees) of them reduced this index to within normal limits in TELOS. 20.0% of the knees with mild patella alta reduced CDI in TELOS but always remained above 1.2. Conclusions: The abnormal ATT in case of ACL-deficient knees results in a lowering effect of the patella in TELOS X-rays. In patients with ACL tear and anterior pain the reconstructive ligament surgery should be performed to avoid also chronic anterior knee pain. Level of evidence: Basic Science Study (Case Series). Clinical relevance: The decrease in patellar height in stress-X-rays compared with standard lateral knee radiography in ACL deficient knees, should be considered as a possible contributing cause of anterior pain in these patients.

6.
Arch Orthop Trauma Surg ; 142(5): 813-821, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-33484309

RESUMO

INTRODUCTION: Preventing nerve injury is critical in elbow surgery. Distal extension of medial approaches, required for coronoid fracture fixation and graft-replacement, may endanger the median nerve. This study aims to describe an easily identifiable and reproducible anatomical landmark to localize the median nerve distal to the joint line and to delineate how its relative position changes with elbow flexion and forearm rotation. MATERIALS AND METHODS: The median nerve and the ulnar insertion of the brachialis muscle were identified in eleven fresh-frozen cadaveric specimens after dissection over an extended medial approach. The elbow was brought first in full extension and then in 90° flexion, and the shortest distance between the two structures was measured while rotating the forearm in full pronation, neutral position and full supination. RESULTS: The distance between the median nerve and the brachialis insertion was highest with the elbow flexed and the forearm in neutral position. All distances measured in flexion were larger than those in extension, and all distances measured from the most proximal point of the brachialis insertion were larger than those from the most distal point. Distances in pronation and in supination were smaller than to those in neutral forearm position. CONCLUSIONS: The ulnar insertion of the brachialis is a reliable landmark to localize and protect the median nerve at the level of the coronoid base. Elbow flexion and neutral forearm position increase significantly the safety margins between the two structures; this information suggests some modifications to the previously described medial elbow approaches. LEVEL OF EVIDENCE: Basic Science Study.


Assuntos
Articulação do Cotovelo , Cotovelo , Cadáver , Cotovelo/fisiologia , Articulação do Cotovelo/fisiologia , Articulação do Cotovelo/cirurgia , Antebraço/fisiologia , Antebraço/cirurgia , Humanos , Nervo Mediano , Músculo Esquelético , Ulna
7.
Knee Surg Sports Traumatol Arthrosc ; 29(12): 4067-4074, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34455451

RESUMO

PURPOSE: The lateral elbow musculature conveys a dynamic valgus moment to the elbow, increasing joint stability. Muscular or tendinous lesions to the anterior half of the common extensor origin (CEO) may provoke a deficiency in the elbow dynamic stabilizers, regardless of their traumatic, degenerative, or iatrogenic aetiology. Furthermore, a role for the radial band of the lateral collateral ligament (R-LCL) has been postulated in the aetiology of lateral elbow pain. This study aimed to evaluate the effects of sequential lateral releases with dynamic ultrasound, evaluating its capability to detect lesions of the CEO and of the R-LCL. METHODS: Ultrasound investigation of the lateral compartment of the elbow was performed on nine cadaveric specimens with a 10 MHz linear probe in basal conditions, after the release of the anterior half of the CEO and after complete R-LCL release. The lateral joint line widening (λ) was the primary outcome parameter, measured as the linear distance between the humeral and radial articular surfaces. RESULTS: The release of the anterior half of the CEO significantly increased λ by 200% compared to the starting position (p = 0.0008) and the previously loaded position (p = 0.0015). Conversely, further release of the R-LCL caused only a marginal, non-significant increase in λ. CONCLUSIONS: Ultrasound evaluation can detect changes related to tendon tears or muscular avulsions of the CEO and can depict lateral elbow compartmental patholaxity by assessing articular space widening while scanning under dynamic stress. However, it cannot reliably define if the R-LCL is injured. Iatrogenic damage to the CEO should be carefully avoided, since it causes a massive increase in compartmental laxity.


Assuntos
Ligamentos Colaterais , Articulação do Cotovelo , Instabilidade Articular , Ligamentos Laterais do Tornozelo , Cadáver , Ligamentos Colaterais/diagnóstico por imagem , Cotovelo , Articulação do Cotovelo/diagnóstico por imagem , Humanos , Instabilidade Articular/diagnóstico por imagem , Instabilidade Articular/etiologia , Rádio (Anatomia) , Amplitude de Movimento Articular
8.
Indian J Orthop ; 55(Suppl 2): 336-346, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34306546

RESUMO

INTRODUCTION: Elbow bony stability relies primarily on the high anatomic congruency between the humeral trochlea and the ulnar greater sigmoid notch. No practical tools are available to distinguish different morphotypes of the proximal ulna and herewith predict elbow stability. The aim of this study was to assess inter-observer reproducibility, evaluate diagnostic performance and determine responsiveness to change after simulated coronoid process fracture for three novel elbow radiographic indexes. METHODS: Ten fresh-frozen cadaver specimens of upper limbs from human donors were available for this study. Three primary indexes were defined, as well as two derived angles: Trochlear Depth Index (TDI); Posterior Coverage Index (PCI); Anterior Coverage Index (ACI); radiographic coverage angle (RCA); olecranon-diaphisary angle (ODA). Each index was first measured on standardized lateral radiographs and subsequently by direct measurement after open dissection. Finally, a type II coronoid fracture (Regan and Morrey classification) was created on each specimen and both radiographic and open measurements were repeated. All measurements were conducted by two orthopaedic surgeons and two dedicated musculoskeletal radiologists. RESULTS: All three indexes showed good or moderate inter-observer reliability and moderate accuracy and precision when compared to the gold standard (open measurement). A significant change between the radiographic TDI and ACI before and after simulated coronoid fracture was observed [TDI: decrease from 0.45 ± 0.03 to 0.39 ± 0.08 (p = 0.035); ACI: decrease from 1.90 ± 0.17 to 1.58 ± 0.21 (p = 0.001)]. As expected, no significant changes were documented for the PCI. Based on these data, a predictive model was generated, able to identify coronoid fractures with a sensitivity of 80% and a specificity of 100%. CONCLUSION: New, simple and easily reproducible radiological indexes to describe the congruency of the greater sigmoid notch have been proposed. TDI and ACI change significantly after a simulated coronoid fracture, indicating a good responsiveness of these parameters to a pathological condition. Furthermore, combining TDI and ACI in a regression model equation allowed to identify simulated fractures with high sensitivity and specificity. The newly proposed indexes are, therefore, promising tools to improve diagnostic accuracy of coronoid fractures and show potential to enhance perioperative diagnostic also in cases of elbow instability and stiffness. LEVEL OF EVIDENCE: Basic science study. CLINICAL RELEVANCE: The newly proposed indexes are promising tools to improve diagnostic accuracy of coronoid fractures as well as to enhance perioperative diagnostic for elbow instability and stiffness.

9.
Indian J Orthop ; 55(Suppl 2): 347-358, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34306547

RESUMO

INTRODUCTION: The coronoid process plays a key-role in preserving elbow stability. Currently, there are no radiographic indexes conceived to assess the intrinsic elbow stability and the joint congruency. The aim of this study is to present new radiological parameters, which will help assess the intrinsic stability of the ulnohumeral joint and to define normal values of these indexes in a normal, healthy population. METHODS: Four independent observers (two orthopaedic surgeons and two radiologists) selected lateral view X-rays of subjects with no history of upper limb disease or surgery. The following radiographic indexes were defined: trochlear depth index (TDI); anterior coverage index (ACI); posterior coverage index (PCI); olecranon-coronoid angle (OCA); radiographic coverage angle (RCA). Inter-observer and intra-observer reproducibility were assessed for each index. RESULTS: 126 subjects were included. Standardized lateral elbow radiographs (62 left and 64 right elbows) were obtained and analysed. The mean TDI was 0.46 ± 0.06 (0.3-1.6), the mean ACI was 2.0 ± 0.2 (1.6-3.1) and the mean PCI was 1.3 ± 0.1 (1.0-1.9). The mean RCA was 179.6 ± 8.3° (normalized RCA: 49.9 ± 2.3%) and the mean OCA was 24.6 ± 3.7°. The indexes had a high-grade of inter-observer and intra-observer reliability for each of the four observers. Significantly higher values were found for males for TDI, ACI, PCI and RCA. CONCLUSION: The novel radiological parameters described are simple, reliable and easily reproducible. These features make them a promising tool for radiographic evaluation both for orthopaedic surgeons and for radiologists in the emergency department setting or during outpatient services. LEVEL OF EVIDENCE: Basic Science Study (Case Series). CLINICAL RELEVANCE: The novel radiological parameters described are reliable, easily reproducible and become handy for orthopaedic surgeons as well as radiologists in daily clinical practice.

10.
Indian J Orthop ; 55(Suppl 1): 182-188, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-34113427

RESUMO

INTRODUCTION: The use of elbow arthroscopy is becoming increasingly common in orthopaedic practice; nevertheless, it is still considered a difficult procedure with a long learning curve. The aim of the study is to evaluate the role of a new elbow Sawbone-Based Arthroscopy Module (e-SBAM) in the training of elbow surgeons. METHODS: Fourteen surgeons were classified as "Expert" (n: 7; more than 10 years of experience in arthroscopic surgery) and "Not-expert" surgeons (n: 7; less than 10 years of experience). During a dedicated arthroscopic session, using the Sawbones Elbow model (Sawbones Europe AB®), all participants were asked to perform an arthroscopic round and to touch three specific landmarks. An independent observer measured the time that each participant needed to perform this task (Performance 1). The same measurement was repeated after two weeks of eSBAM training (Performance 2). RESULTS: "Not-expert" surgeons needed significantly more time (41 s; range 26-120) than "Expert" ones (13 s; range 8-36) to complete Performance 1. One "Not-expert" surgeon did not complete Performance 1 and needed more than 120 s for Performance 2. The whole study group required a median of 5 s less to complete Performance 2. A tendency towards an improvement was observed in the group of the non-experienced surgeons as compared with the experienced ones. CONCLUSIONS: The simulation training can be advantageous in the learning curve of young elbow surgeons and helpful for experienced surgeons. E-SBAM can be used as an effective tool for the current stepwise arthroscopic elbow training programs with the aim of improving arthroscopic elbow skills. LEVEL OF EVIDENCE: Basic Science Study.

11.
Am J Sports Med ; 49(9): 2332-2340, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-34115528

RESUMO

BACKGROUND: An elongation of the radial lateral collateral complex (R-LCL) can provoke symptomatic minor instability of the lateral elbow leading to lateral elbow pain. Biomechanical models investigating the effects of elongation and partial or complete lesions of the R-LCL on lateral elbow stability are lacking. PURPOSE: To evaluate how partial and complete R-LCL release affects radiocapitellar joint stability in a setting of controlled varus load and progressive soft tissue release. STUDY DESIGN: Controlled laboratory study. METHODS: Ten fresh-frozen cadaveric specimens were obtained and mounted on a custom-made support to control elbow flexion and extension and to allow for controlled varus loading. Stress tests were performed on all intact specimens under gravity load alone, a 0.5-kg load applied to the hand, and a 1-kg load applied to the hand. After load application, anteroposterior radiographs were obtained. The following release sequence was applied to all specimens: release of the anterior half of the common extensor origin, pie crusting of the R-LCL, and R-LCL release. After each release, stress tests and radiographs were performed. The varus joint angulation of the elbow (α) was measured by 2 examiners as the main outcome parameter. RESULTS: Significant changes in α from the initial condition occurred after each release, and a significant effect of varus load on α was documented for all release steps. A significant effect of the releases on α could be documented for all identical varus load conditions. A linear regression model was generated to describe the effect of varus load on α. CONCLUSION: Varus loads simulating everyday activities produce changes in the varus joint angulation of the elbow already in the intact specimen, which are linearly dependent on the applied moment and persist after release of the lateral stabilizing structures. With progressive load, a pie crusting of the R-LCL is the minimal procedure able to provoke a significant change in the varus joint angulation, and a complete R-LCL release produces additional increase in the varus joint angulation in all testing conditions. CLINICAL RELEVANCE: These findings confirm the role of the R-LCL as static lateral stabilizer, supporting a pathological model based on its insufficiency and culminating with a symptomatic minor instability of the lateral elbow.


Assuntos
Ligamentos Colaterais , Articulação do Cotovelo , Instabilidade Articular , Ligamentos Laterais do Tornozelo , Fenômenos Biomecânicos , Cadáver , Ligamentos Colaterais/diagnóstico por imagem , Cotovelo , Articulação do Cotovelo/diagnóstico por imagem , Humanos , Amplitude de Movimento Articular
12.
Arch Orthop Trauma Surg ; 141(4): 675-681, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33417023

RESUMO

INTRODUCTION: Greater trochanter (GT) fractures affect 0.6-29% of patients after direct anterior approach (DAA) total hip arthroplasty (THA). Given the growing popularity of this approach, this study aimed to assess the evolution of the GT fractures during the learning curve, their risk factors and their consequences. MATERIALS AND METHODS: 537 total hip arthroplasties were retrospectively included from May 2013 to December 2017 in a single academic centre. Patient characteristics, perioperative management, clinical consequences and postoperative radiographs were analysed. RESULTS: GT fractures represented 2.4% (n = 13) of the THA, and there was not a decrease with experience. The GT fracture patients did not require any additional support during the surgery, and full weight bearing was always allowed without any restriction. This complication only happened in females, with the risk significantly increased in those > 70 years old (OR = 4.9). There was no specific consequence during the follow-up, mean HHS score was 98.5 and all of the patients were satisfied or very satisfied postoperatively. CONCLUSION: Older osteoporotic women are known to be at risk for GT fracture during DAA THA. Those results reinforce the argument in favour of proper patient selection in DAA to lower the complications since it does not improve with surgeon's experience. LEVEL OF EVIDENCE: Retrospective, consecutive case series; Level IV.


Assuntos
Artroplastia de Quadril , Fraturas do Fêmur/cirurgia , Fêmur/cirurgia , Idoso , Competência Clínica , Feminino , Humanos , Curva de Aprendizado , Masculino , Estudos Retrospectivos , Fatores de Risco
13.
Med Glas (Zenica) ; 18(1): 287-292, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-33269583

RESUMO

Aim The septic non-union is a common compliance in bone healing due to bone infection. Bone resection, associated with Ilizarov osteo-distraction technique, is commonly used in these cases. The aim of this study was to analyse clinical and radiological results of teriparatide in combination with the Ilizarov technique and to compare this treatment with the standard treatment. Methods Forty adult patients underwent surgery because of type C of the Association for the Study and Application of Methods of Ilizarov (ASAMI) classification non-union were enrolled. The patients were divided in two groups: those treated with Ilizarov technique (Norm group) and those treated with Ilizarov technique combined with teriparatide injection (Teri group). Surgical duration, complication rate, bone healing status, clinical and functional outcomes were assessed according to the A.S.A.M.I. classification in the mean follow-up of 12 months. The subjective quality of life was assessed by the Short Form Survey (SF)-12. Results Teri group showed less time wearing Ilizarov's frame (p <0.05) than the Norm group and a statistical significance in the inter-rater reliability Cohen's k (p>0.05) respect to Norm according the score between the bone healing and clinical outcome results. There was no statistically significant difference between the two groups in other parameters that were assessed. Conclusion A benefit of teriparatide was found as adjuvant in the treatment of septic non-union.


Assuntos
Técnica de Ilizarov , Fraturas da Tíbia , Adulto , Humanos , Qualidade de Vida , Reprodutibilidade dos Testes , Estudos Retrospectivos , Teriparatida/uso terapêutico , Resultado do Tratamento
14.
Indian J Orthop ; 54(Suppl 2): 292-296, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33194104

RESUMO

INTRODUCTION: The strength of forearm in pronation and supination (P/S) is an important clinical assessment during pre-operative examination as well as in post-operative evaluation. Many clinical trials concerning the measurement of forearm P/S strength were performed using a dynamometer fixed on the wall. The aim of this study was to bring out a simple and reliable technique for the measurement of P/S strength using a dynamometer manually supported and stabilized by an examiner. We hypothesized that there are no differences in evaluation of elbow P/S strength using the dynamometer fixed or the dynamometer stabilized by an operator in healthy people. METHODS: The study was performed on a cross-sectional cohort of 100 healthy subjects without any history of injuries or previous surgery of the upper limbs. Isometric forearm P/S strengths were measured on the dominant and non-dominant forearms, using the dynamometer fixed on a table, and using the same dynamometer kept by an operator. The measurements were repeated in triplicate at 45°, 90° and 120° of elbow flexion in both upper limbs for all patients. RESULTS: A total of 100 subjects (50 females, 50 males) were included in the study group. The mean age was 46.5 years (range 25-52 years). Female and male subjects showed no significant differences concerning the mean age (F/M ratio 0.50/0.50). The mean body mass index of all participants was 24.34 ± 3.66 kg/m2.No significant statistics difference was reported between the P/S strength measured using the two detection methods in our study group (45°, 90° and 120° of elbow flexion and both upper limbs). CONCLUSION: The manually stabilized technique is a valid and reliable technique to assess the P/S strength of the forearm. This is a simple and effective method that may be reproduced in our daily clinical practice as well as in sportive practice.

15.
J Orthop Surg Res ; 15(1): 476, 2020 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-33066797

RESUMO

BACKGROUND: Juvenile hip osteoarthritis is often the end result of congenital conditions or acquired hip ailments occurred during the paediatric age. This study evaluated the middle term results of total hip arthroplasty for end-stage juvenile hip osteoarthritis. MATERIALS AND METHODS: This is a retrospective analysis of prospectively collected data on a cohort of 10 consecutive patients (12 hips), aged between 14 and 20 at operation, who underwent cementless total hip arthroplasty for end-stage juvenile secondary hip osteoarthritis in two orthopaedic tertiary referral centres between 2009 and 2018. RESULTS: Juvenile hip osteoarthritis occurred as a consequence of developmental dysplasia of the hip, Legg-Calvé-Perthes disease, femoral head necrosis or slipped capital femoral epiphysis. All patients showed a significant improvement in Harris Hip Score (p < 0.01) at 3.3 years average follow-up (range 0.7-10.1 years). CONCLUSION: The management of juvenile hip osteoarthritis following developmental dysplasia of the hip, Legg-Calvé-Perthes disease, femoral head necrosis or slipped capital femoral epiphysis is still challenging. Careful preoperative planning is essential to achieve good outcomes and improve the Harris Hip Score in these young patients. Total hip arthroplasty is a suitable option for end-stage secondary juvenile hip osteoarthritis, when proximal femoral osteotomies and conservative treatments fail to improve patients' symptoms and quality of life. LEVEL OF EVIDENCE: IV.


Assuntos
Artroplastia de Quadril/métodos , Osteoartrite do Quadril/cirurgia , Adolescente , Adulto , Fatores Etários , Feminino , Necrose da Cabeça do Fêmur/complicações , Seguimentos , Luxação do Quadril/complicações , Humanos , Doença de Legg-Calve-Perthes/complicações , Masculino , Osteoartrite do Quadril/etiologia , Estudos Retrospectivos , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
16.
SICOT J ; 6: 35, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32880573

RESUMO

INTRODUCTION: Distal Femoral Osteotomy (DFO) is a common procedure for correcting lower limb valgus deformity and lateral compartment overload. Low 20-year survivorship rate was reported with a consequent need for total knee arthroplasty (TKA). This study aims to review literature and to analyse the influence of a previous distal femoral osteotomy on outcomes of patients undergoing TKA. METHODS: A systematic literature review was performed in PubMed/Medline and Embase in May 2020. Papers were selected based on the following criteria: patient with a previous distal femoral osteotomy; total knee replacement; Pre- and Postoperative outcomes; surgical outcomes: clinical scores, range of motion, radiographic evaluation and revisions for any cause; case series, retrospective studies, observational studies, open-label studies, randomized clinical trials; systematic reviews and meta-analyses were included to extract primitive studies. RESULTS: 306 articles were found, of which five papers were considered eligible for this review. In every study included, postoperative clinical outcomes (Knee Society Score or Hospital for Special Surgery score) statistically improved from the preoperative. Complications were not uncommon; implant survivorship at the available follow-up seems to be similar to primary TKA, although being too short to draw any conclusions. CONCLUSIONS: Limited and highly heterogeneous evidence is currently available on the influence of DFO on outcomes after TKA. Knee replacement improves clinical middle-term outcomes in patients with previous distal femoral osteotomy. In this complex surgery, the use of technical tips and tricks could help surgeons to obtain an accurate knee balancing and better long-term results.

17.
Indian J Orthop ; 54(5): 539-547, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32843951

RESUMO

BACKGROUND: Correct sizing is challenging in radial head replacement and no consensus exists on the implant's optimal height and width to avoid elbow stiffness and instability. Studies exists, suggesting how to appropriately choose the implant size, but the manner by which the fracture pattern influences the surgeons' operative choices was not investigated. METHODS: The radial heads of four fresh-frozen cadaveric specimens were excised, measured, and fractured to simulate four patterns: three fragments (A); four fragments (B); comminuted (C); comminuted with bone loss (D). Nine examiners were asked to indicate first the maximum diameter of the radial heads with the help of dedicated sizing dishes and then the appropriate implant size with trial implants. Accuracy and precision were determined. A coefficient of variation was calculated and agreement was evaluated with the Bland-Altman method. RESULTS: Accuracy and precision of radial head diameter estimation with dedicated sizing dish were 96.73% and 93.64%, (best pattern, D; worst, C). Accuracy and precision of radial head diameter estimation with trial implants were 99.71% and 90.66% (best pattern, A; worst, D). Frequent modifications occurred between the initial radial head size proposal based on the sizing dish and the radial head size chosen after use of the trial implants (47.2%). CONCLUSIONS: Diameter estimation of radial heads with dedicated sizing dishes may be underestimated in comminuted fractures; when bone loss is present, this may lead to an overestimation, especially when using trial implants. Care is essential to determine the optimal size of the implant and to avoid overlenghtening and oversizing, which can be responsible for implant failure. LEVEL OF EVIDENCE: Basic Science Study. CLINICAL RELEVANCE: Knowledge of the manner by which the fracture pattern influences radial head replacement size estimation can help preventing overlenghtening and oversizing during this procedure.

20.
Int Orthop ; 44(9): 1669-1676, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32393990

RESUMO

PURPOSE: Cup positioning is important for optimum hip stability, avoiding component impingement and decreasing both bearing surface wear and revision rate. Transitioning from posterior approach in a lateral position to direct anterior approach (DAA) in a supine presents unique challenges for surgeons. The aim of this study was to examine the learning curve when using standard instrumentation that was not specific to DAA. METHODS: A consecutive retrospective series of 537 total hip arthroplasty by DAA from May 2013 to December 2017. Cup positioning was analysed on radiographs and classified whether inside or outside two safe zones (inclination 30-50° and anteversion 10-30°). The demographic data (age, BMI, gender, neck shaft angle (NSA)), surgeon's dominant side and experience were assessed as risk factors. RESULTS: Eighty per cent of cups (n = 426) were in the combined safe zones. Eighty-eight per cent (n = 470) were in appropriate anteversion and 87% (n = 463) abduction. Two factors that were significant were identified: Cups of left hips operated by right-handed surgeons were more anteverted (OR = 4.06) and more vertical (OR = 2.23); females had a higher anteversion of the cup (OR = 2.42). Obesity, age and NSA were not risk factors for cup malposition. There was a spike of cups too horizontal at the beginning of the experience (OR = 3.86), and no learning curve was observed in the other orientations. CONCLUSION: With our DAA technique using standard instrumentation, there were no risk factors linked to the patient identified for cup malposition. DAA-specific instrumentation is not required to achieve optimum positioning of the cup. Surgeon has to be aware of an excess of abduction at the beginning of his experience and an excess of anteversion and adduction when performing THA on the opposite side of his dominant hand.


Assuntos
Artroplastia de Quadril , Hepatite C Crônica , Prótese de Quadril , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Artroplastia de Quadril/efeitos adversos , Feminino , Prótese de Quadril/efeitos adversos , Humanos , Curva de Aprendizado , Estudos Retrospectivos , Fatores de Risco , Decúbito Dorsal
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA