2.
Cereb Circ Cogn Behav ; 3: 100142, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36324395

RESUMO

Perivascular spaces (PVS) are believed to be involved in brain waste disposal. PVS are associated with cerebral small vessel disease. At higher field strengths more PVS can be observed, challenging manual assessment. We developed a method to automatically detect and quantify PVS. A machine learning approach identified PVS in an automatically positioned ROI in the centrum semiovale (CSO), based on -resolution T2-weighted TSE scans. Next, 3D PVS tracking was performed in 50 subjects (mean age 62.9 years (range 27-78), 19 male), and quantitative measures were extracted. Maps of PVS density, length, and tortuosity were created. Manual PVS annotations were available to train and validate the automatic method. Good correlation was found between the automatic and manual PVS count: ICC (absolute/consistency) is 0.64/0.75, and Dice similarity coefficient (DSC) is 0.61. The automatic method counts fewer PVS than the manual count, because it ignores the smallest PVS (length <2 mm). For 20 subjects manual PVS annotations of a second observer were available. Compared with the correlation between the automatic and manual PVS, higher inter-observer ICC was observed (0.85/0.88), but DSC was lower (0.49 in 4 persons). Longer PVS are observed posterior in the CSO compared with anterior in the CSO. Higher PVS tortuosity are observed in the center of the CSO compared with the periphery of the CSO. Our fully automatic method can detect PVS in a 2D slab in the CSO, and extract quantitative PVS parameters by performing 3D tracking. This method enables automated quantitative analysis of PVS.

3.
Magn Reson Med ; 83(2): 695-711, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31483521

RESUMO

PURPOSE: Local specific absorption rate (SAR) cannot be measured and is usually evaluated by offline numerical simulations using generic body models that of course will differ from the patient's anatomy. An additional safety margin is needed to include this intersubject variability. In this work, we present a deep learning-based method for image-based subject-specific local SAR assessment. We propose to train a convolutional neural network to learn a "surrogate SAR model" to map the relation between subject-specific B1+ maps and the corresponding local SAR. METHOD: Our database of 23 subject-specific models with an 8-transmit channel body array for prostate imaging at 7 T was used to build 5750 training samples. These synthetic complex B1+ maps and local SAR distributions were used to train a conditional generative adversarial network. Extra penalization for local SAR underestimation errors was included in the loss function. In silico and in vivo validation were performed. RESULTS: In silico cross-validation shows a good qualitative and quantitative match between predicted and ground-truth local SAR distributions. The peak local SAR estimation error distribution shows a mean overestimation error of 15% with 13% probability of underestimation. The higher accuracy of the proposed method allows the use of less conservative safety factors compared with standard procedures. In vivo validation shows that the method is applicable with realistic measurement data with impressively good qualitative and quantitative agreement to simulations. CONCLUSION: The proposed deep learning method allows online image-based subject-specific local SAR assessment. It greatly reduces the uncertainty in current state-of-the-art SAR assessment methods, reducing the time in the examination protocol by almost 25%.


Assuntos
Aprendizado Profundo , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Algoritmos , Simulação por Computador , Bases de Dados Factuais , Voluntários Saudáveis , Humanos , Masculino , Modelos Estatísticos , Redes Neurais de Computação , Imagens de Fantasmas , Reprodutibilidade dos Testes , Razão Sinal-Ruído
4.
IEEE Trans Biomed Eng ; 66(10): 2848-2854, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-30716028

RESUMO

OBJECTIVE: To develop a novel radio-frequency (RF) concept for ultra-high field (UHF) human magnetic resonance imaging (MRI) based on a coaxial resonant cavity. METHODS: A two-channel slotted coaxial cavity RF applicator was designed for human head MRI at 9.4T. Physical dimensions made the proposed conducting structure resonant at the required frequency without tuning lumped elements. Numerical electromagnetic modeling was used to optimize the design. RF safety was assessed with two representative human body models. MR experiments on a 9.4T scanner included gradient echo images and mapping of a circularly polarized RF magnetic field in the human head phantom. RESULTS: The simulations and the phantom MR experiments agreed both qualitatively and quantitatively. The design was relatively simple, robust and required only a few additional reactive elements for the applicator's input impedance matching. The transmit efficiency and homogeneity of the excitation field were only 20% and 4% lower compared to a conventional 8-channel head array. CONCLUSION: The coaxial RF applicator was feasible for human MRI at UHF and required no lumped elements for its tuning. Imaging performance of the RF applicator was only moderately lower compared to the conventional transmit array, but would be sufficient to provide an anatomical reference for the heteronuclei MRI. SIGNIFICANCE: An alternative approach with the minimal involvement of lumped elements becomes feasible to design volume-type RF coils for UHF human MRI.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Desenho de Equipamento , Segurança de Equipamentos , Cabeça , Humanos , Imagens de Fantasmas , Ondas de Rádio
5.
NMR Biomed ; 32(1): e4015, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30376201

RESUMO

The differentiation grade of cervical cancer is histologically assessed by examining biopsies or surgical specimens. MRS is a highly sensitive technique that images tissue metabolism and can be used to increase the specificity of tissue characterization in a non-invasive manner. We aim to explore the feasibility of using in vivo 1 H-MRS at 7 T in women with cervical cancer to study tissue fatty acid composition. 10 women with histologically proven Stage IB1-IIB cervical cancer were scanned with a whole-body 7 T MR system with a multi-transmit system and an internal receive only monopole antenna. A STEAM sequence was used to obtain 1 H-MRS data. Fatty acid resonances were fitted with Lorentzian curves and the 2.1 ppm/1.3 ppm ratios were calculated. 1 H-MRS data showed fatty acid signals resonating at 2.1 ppm, 1.9 ppm, 1.5 ppm, 1.3 ppm and 0.9 ppm. Mean 2.1/1.3 ppm ratios were 0.019 ± 0.01, 0.021 ± 0.006, 0.12 ± 0.089 and 0.39 ± 0.27 for normal, Grade I, Grade II and Grade III groups respectively. Poorly differentiated tumor tissue (Grade III) showed elevated fatty acid ratios when compared with the well differentiated tumor (Grade I) or normal tissue. 1 H-MRS in cervical cancer at 7 T is feasible and individual fatty acid signals were detected. In addition, poorly differentiated tumors show more fatty acid unsaturation. The 2.1 ppm/1.3 ppm ratio has potential for tumor characterization in a non-invasive manner for uterine cervical cancer.


Assuntos
Espectroscopia de Prótons por Ressonância Magnética , Neoplasias do Colo do Útero/diagnóstico por imagem , Adulto , Idoso , Ácidos Graxos/metabolismo , Feminino , Humanos , Pessoa de Meia-Idade , Gradação de Tumores , Neoplasias do Colo do Útero/patologia
6.
AJNR Am J Neuroradiol ; 39(4): 713-719, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29472302

RESUMO

BACKGROUND AND PURPOSE: Aneurysm volume pulsation is a potential predictor of intracranial aneurysm rupture. We evaluated whether 7T MR imaging can quantify aneurysm volume pulsation. MATERIALS AND METHODS: In Stage I of the study, 10 unruptured aneurysms in 9 patients were studied using a high-resolution (0.6-mm, isotropic) 3D gradient-echo sequence with cardiac gating. Semiautomatic segmentation was used to measure aneurysm volume (in cubic millimeters) per cardiac phase. Aneurysm pulsation was defined as the relative increase in volume between the phase with the smallest volume and the phase with the largest volume. The accuracy and precision of the measured volume pulsations were addressed by digital phantom simulations and a repeat image analysis. In Stage II, the imaging protocol was optimized and 9 patients with 9 aneurysms were studied with and without administration of a contrast agent. RESULTS: The mean aneurysm pulsation in Stage I was 8% ± 7% (range, 2%-27%), with a mean volume change of 15 ± 14 mm3 (range, 3-51 mm3). The mean difference in volume change for the repeat image analysis was 2 ± 6 mm3. The artifactual volume pulsations measured with the digital phantom simulations were of the same magnitude as the volume pulsations observed in the patient data, even after protocol optimization in Stage II. CONCLUSIONS: Volume pulsation quantification with the current imaging protocol on 7T MR imaging is not accurate due to multiple imaging artifacts. Future studies should always include aneurysm-specific accuracy analysis.


Assuntos
Aneurisma Intracraniano/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Neuroimagem/métodos , Adulto , Idoso , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Fluxo Pulsátil
7.
NMR Biomed ; 30(9)2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28574604

RESUMO

The aim of this study was to investigate the signal-to-noise ratio (SNR) gain in early-stage cervical cancer at ultrahigh-field MRI (e.g. 7 T) using a combination of multiple external antennas and a single endorectal antenna. In particular, we used an endorectal monopole antenna to increase the SNR in cervical magnetic resonance imaging (MRI). This should allow high-resolution, T2 -weighted imaging and magnetic resonance spectroscopy (MRS) for metabolic staging, which could facilitate the local tumor status assessment. In a prospective feasibility study, five healthy female volunteers and six patients with histologically proven stage IB1-IIB cervical cancer were scanned at 7 T. We used seven external fractionated dipole antennas for transmit-receive (transceive) and an endorectally placed monopole antenna for reception only. A region of interest, containing both normal cervix and tumor tissue, was selected for the SNR measurement. Separated signal and noise measurements were obtained in the region of the cervix for each element and in the near field of the monopole antenna (radius < 30 mm) to calculate the SNR gain of the endorectal antenna in each patient. We obtained high-resolution, T2 -weighted images with a voxel size of 0.7 × 0.8 × 3.0 mm3 . In four cases with optimal placement of the endorectal antenna (verified on the T2 -weighted images), a mean gain of 2.2 in SNR was obtained at the overall cervix and tumor tissue area. Within a radius of 30 mm from the monopole antenna, a mean SNR gain of 3.7 was achieved in the four optimal cases. Overlap between the two different regions of the SNR calculations was around 24%. We have demonstrated that the use of an endorectal monopole antenna substantially increases the SNR of 7-T MRI at the cervical anatomy. Combined with the intrinsically high SNR of ultrahigh-field MRI, this gain may be employed to obtain metabolic information using MRS and to enhance spatial resolutions to assess tumor invasion.


Assuntos
Imageamento por Ressonância Magnética/métodos , Reto/diagnóstico por imagem , Razão Sinal-Ruído , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/patologia , Adulto , Idoso , Feminino , Humanos , Estadiamento de Neoplasias
8.
Magn Reson Med ; 78(6): 2449-2459, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28164362

RESUMO

PURPOSE: We introduce a new MR-based method to determine the transfer function (TF) for radiofrequency (RF) safety assessment of active implantable medical devices. Transfer functions are implant-specific measures that relate the incident tangential electric field on an (elongated) implant to a scattered electric field at its tip. The proposed method allows for TF determination with a high spatial resolution in relatively fast measurements without requiring dedicated bench setups from MRI images. THEORY AND METHODS: The principle of reciprocity is used in conjunction with the potential to measure currents with MRI to determine TF. Low-flip angle 3D dual gradient echo MRI data are acquired with an implant as transceive antenna, which requires minimal hardware adaptations. The implant-specific TF is determined from the acquired MRI data, with two different postprocessing methods for comparison. RESULTS: TFs of linear and helical implants can be determined accurately (with a Pearson correlation coefficient R ≥ 0.7 between measurements and simulations, and a difference in field at the tip ΔEtip ≤ 19%) from relatively quick (t < 20 minutes) MRI acquisitions with (several) millimeter spatial resolution. CONCLUSION: Transfer function determination with MRI for RF safety assessment of implantable medical devices is possible. The proposed MR-based method allows for TF determination in more realistic exposure scenarios and solid media. Magn Reson Med 78:2449-2459, 2017. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Próteses e Implantes , Animais , Gráficos por Computador , Simulação por Computador , Estimulação Encefálica Profunda , Campos Eletromagnéticos , Radiação Eletromagnética , Humanos , Campos Magnéticos , Imagens de Fantasmas , Ondas de Rádio , Reprodutibilidade dos Testes , Razão Sinal-Ruído
9.
Magn Reson Med ; 77(1): 221-228, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-26762855

RESUMO

PURPOSE: Development of a passive respiratory motion sensor based on the noise variance of the receive coil array. METHODS: Respiratory motion alters the body resistance. The noise variance of an RF coil depends on the body resistance and, thus, is also modulated by respiration. For the noise variance monitoring, the noise samples were acquired without and with MR signal excitation on clinical 1.5/3 T MR scanners. The performance of the noise sensor was compared with the respiratory bellow and with the diaphragm displacement visible on MR images. Several breathing patterns were tested. RESULTS: The noise variance demonstrated a periodic, temporal modulation that was synchronized with the respiratory bellow signal. The modulation depth of the noise variance resulting from the respiration varied between the channels of the array and depended on the channel's location with respect to the body. The noise sensor combined with MR acquisition was able to detect the respiratory motion for every k-space read-out line. CONCLUSION: Within clinical MR systems, the respiratory motion can be detected by the noise in receive array. The noise sensor does not require careful positioning unlike the bellow, any additional hardware, and/or MR acquisition. Magn Reson Med 77:221-228, 2017. © 2016 Wiley Periodicals, Inc.


Assuntos
Imageamento por Ressonância Magnética/métodos , Movimento/fisiologia , Respiração , Processamento de Sinais Assistido por Computador , Algoritmos , Diafragma/diagnóstico por imagem , Diafragma/fisiologia , Humanos , Ondas de Rádio , Razão Sinal-Ruído
10.
Med Phys ; 43(7): 4375, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27370152

RESUMO

PURPOSE: The high precession frequency in ultrahigh field MRI coincides with reduced RF penetration, increased RF power deposition and consequently can lead to reduced scan efficiency. However, the shorter wavelength enables the use of efficient antennas rather than loop coils. In fact, ultrathin monopole antennas have been demonstrated at 7 T, which fit in natural cavities like the rectum in the human body. As the RF field generated by the antenna provides an extremely nonuniform B1 field, the use of conventional RF pulses will lead to severe image distortions and highly nonuniform contrast. However, using the two predominant dimensions (orthogonal to the antenna), 2D RF pulses can be designed that counteract the nonuniform B1 into uniform flip angles. In this study the authors investigate the use of an ultrathin antenna not only for reception, but also for transmission in 7 T MRI of the rectum. METHODS: The 2D radially compensating excitation (2D RACE) pulse was designed in matlab. SAR calculations between the 2D RACE pulse and an adiabatic RF pulse (BIR-4) have been obtained, to visualize the gain in decreasing the SAR when using the 2D RACE pulse instead of an adiabatic RF pulse. The authors used the 7 T whole body MR system in combination with an internally placed monopole antenna used for transceiving and obtained 3D gradient echo images with a conventional sinc pulse and with the 2D RACE pulse. For extra clarity, they also reconstructed an image where the receive field of the antenna was removed. RESULTS: Comparing the results of the SAR simulations of the 2D RACE pulse with a BIR-4 pulse shows that for low flip angles (θ < 41°) the SAR can be decreased with a factor of 4.8 or even more, when using the 2D RACE pulse. Relative to a conventional sinc excitation, the 2D RACE pulse achieves more uniform flip angle distributions than a BIR-4 pulse with a smaller SAR increase (16 × versus 64 ×). CONCLUSIONS: The authors have shown that the 2D RACE pulse provides more homogeneous flip angles for gradient echo sequences when compared to a conventional sinc pulse albeit at increased SAR. However, when compared to adiabatic RF pulses, as shown by simulations, the SAR of the 2D RACE pulse can be an order of magnitude less. Phantom and in vivo human rectum images are obtained to demonstrate that the 2D RACE pulse can provide a uniform excitation while transmitting with a single ultrathin endorectal antenna at 7 T. The combination of thin rectal antennas with efficient uniform transmit can open up new possibilities in high resolution imaging of rectal cancer.


Assuntos
Imageamento Tridimensional/instrumentação , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Reto/diagnóstico por imagem , Algoritmos , Simulação por Computador , Desenho de Equipamento , Humanos , Modelos Anatômicos , Imagens de Fantasmas , Software
11.
Neuroradiology ; 58(9): 853-7, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27236563

RESUMO

INTRODUCTION: Cerebellar cortical infarct cavities are a newly recognised entity associated with atherothromboembolic cerebrovascular disease and worse physical functioning. We aimed to investigate the relationship of cerebellar cortical infarct cavities with symptomatic vertebrobasilar ischaemia and with vascular risk factors. METHODS: We evaluated the MR images of 46 patients with a recent vertebrobasilar TIA or stroke and a symptomatic vertebral artery stenosis ≥50 % from the Vertebral Artery Stenting Trial (VAST) for the presence of cerebellar cortical infarct cavities ≤1.5 cm. At inclusion in VAST, data were obtained on age, sex, history of vertebrobasilar TIA or stroke, and vascular risk factors. Adjusted risk ratios were calculated with Poisson regression analyses for the relation between cerebellar cortical infarct cavities and vascular risk factors. RESULTS: Sixteen out of 46 (35 %) patients showed cerebellar cortical infarct cavities on the initial MRI, and only one of these 16 patients was known with a previous vertebrobasilar TIA or stroke. In patients with symptomatic vertebrobasilar ischaemia, risk factor profiles of patients with cerebellar cortical infarct cavities were not different from patients without these cavities. CONCLUSION: Cerebellar cortical infarct cavities are seen on MRI in as much as one third of patients with recently symptomatic vertebral artery stenosis. Since patients usually have no prior history of vertebrobasilar TIA or stroke, cerebellar cortical infarct cavities should be added to the spectrum of common incidental brain infarcts visible on routine MRI.


Assuntos
Doenças Cerebelares/epidemiologia , Infarto Cerebral/epidemiologia , Angiografia por Ressonância Magnética/estatística & dados numéricos , Insuficiência Vertebrobasilar/epidemiologia , Insuficiência Vertebrobasilar/cirurgia , Distribuição por Idade , Causalidade , Doenças Cerebelares/diagnóstico por imagem , Doenças Cerebelares/prevenção & controle , Infarto Cerebral/diagnóstico por imagem , Infarto Cerebral/prevenção & controle , Comorbidade , Feminino , Humanos , Achados Incidentais , Masculino , Pessoa de Meia-Idade , Países Baixos/epidemiologia , Prevalência , Fatores de Risco , Distribuição por Sexo , Stents/estatística & dados numéricos , Resultado do Tratamento , Insuficiência Vertebrobasilar/diagnóstico por imagem
12.
NMR Biomed ; 29(6): 709-20, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27037615

RESUMO

Widespread use of ultrahigh-field (31) P MRSI in clinical studies is hindered by the limited field of view and non-uniform radiofrequency (RF) field obtained from surface transceivers. The non-uniform RF field necessitates the use of high specific absorption rate (SAR)-demanding adiabatic RF pulses, limiting the signal-to-noise ratio (SNR) per unit of time. Here, we demonstrate the feasibility of using a body-sized volume RF coil at 7 T, which enables uniform excitation and ultrafast power calibration by pick-up probes. The performance of the body coil is examined by bench tests, and phantom and in vivo measurements in a 7-T MRI scanner. The accuracy of power calibration with pick-up probes is analyzed at a clinical 3-T MR system with a close to identical (1) H body coil integrated at the MR system. Finally, we demonstrate high-quality three-dimensional (31) P MRSI of the human body at 7 T within 5 min of data acquisition that includes RF power calibration. Copyright © 2016 John Wiley & Sons, Ltd.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Espectroscopia de Ressonância Magnética/instrumentação , Magnetismo/instrumentação , Imagem Molecular/instrumentação , Compostos de Fósforo/metabolismo , Isótopos de Fósforo/farmacocinética , Imagem Corporal Total/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Transdutores
13.
AJNR Am J Neuroradiol ; 37(7): 1310-7, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26892986

RESUMO

BACKGROUND AND PURPOSE: Both hemodynamics and aneurysm wall thickness are important parameters in aneurysm pathophysiology. Our aim was to develop a method for semi-quantitative wall thickness assessment on in vivo 7T MR images of intracranial aneurysms for studying the relation between apparent aneurysm wall thickness and wall shear stress. MATERIALS AND METHODS: Wall thickness was analyzed in 11 unruptured aneurysms in 9 patients who underwent 7T MR imaging with a TSE-based vessel wall sequence (0.8-mm isotropic resolution). A custom analysis program determined the in vivo aneurysm wall intensities, which were normalized to the signal of nearby brain tissue and were used as measures of apparent wall thickness. Spatial wall thickness variation was determined as the interquartile range in apparent wall thickness (the middle 50% of the apparent wall thickness range). Wall shear stress was determined by using phase-contrast MR imaging (0.5-mm isotropic resolution). We performed visual and statistical comparisons (Pearson correlation) to study the relation between wall thickness and wall shear stress. RESULTS: 3D colored apparent wall thickness maps of the aneurysms showed spatial apparent wall thickness variation, which ranged from 0.07 to 0.53, with a mean variation of 0.22 (a variation of 1.0 roughly means a wall thickness variation of 1 voxel [0.8 mm]). In all aneurysms, apparent wall thickness was inversely related to wall shear stress (mean correlation coefficient, -0.35; P < .05). CONCLUSIONS: A method was developed to measure the wall thickness semi-quantitatively, by using 7T MR imaging. An inverse correlation between wall shear stress and apparent wall thickness was determined. In future studies, this noninvasive method can be used to assess spatial wall thickness variation in relation to pathophysiologic processes such as aneurysm growth and rupture.


Assuntos
Imageamento Tridimensional/métodos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Neuroimagem/métodos , Idoso , Feminino , Hemodinâmica/fisiologia , Humanos , Aneurisma Intracraniano/patologia , Masculino , Pessoa de Meia-Idade , Estresse Mecânico
15.
NMR Biomed ; 29(9): 1122-30, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-26278544

RESUMO

Although the potential of dipole antennas for ultrahigh-field (UHF) MRI is largely recognized, they are still relatively unknown to the larger part of the MRI community. This article intends to provide electromagnetic insight into the general operating principles of dipole antennas by numerical simulations. The major part focuses on a comparison study of dipole antennas and loop coils at frequencies of 128, 298 and 400 MHz. This study shows that dipole antennas are only efficient radiofrequency (RF) coils in the presence of a dielectric and/or conducting load. In addition, the conservative electric fields (E-fields) at the ends of a dipole are negligible in comparison with the induced E-fields in the center. Like loop coils, long dipole antennas perform better than short dipoles for deeply located imaging targets and vice versa. When the optimal element is chosen for each depth, loop coils have higher B1 (+) efficiency for shallow depths, whereas dipole antennas have higher B1 (+) efficiency for large depths. The cross-over point depth decreases with increasing frequency: 11.6, 6.2 and 5.0 cm for 128, 298 and 400 MHz, respectively. For single elements, loop coils demonstrate a better B1 (+) /√SARmax ratio for any target depth and any frequency. However, one example study shows that, in an array setup with loop coil overlap for decoupling, this relationship is not straightforward. The overlapping loop coils may generate increased specific absorption rate (SAR) levels under the overlapping parts of the loops, depending on the drive phase settings. Copyright © 2015 John Wiley & Sons, Ltd.


Assuntos
Aumento da Imagem/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Magnetismo/instrumentação , Modelos Teóricos , Transdutores , Imagem Corporal Total/instrumentação , Animais , Simulação por Computador , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Campos Magnéticos , Imagens de Fantasmas , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
16.
AJNR Am J Neuroradiol ; 37(5): 802-10, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26705320

RESUMO

BACKGROUND AND PURPOSE: In recent years, several high-resolution vessel wall MR imaging techniques have emerged for the characterization of intracranial atherosclerotic vessel wall lesions in vivo. However, a thorough validation of MR imaging results of intracranial plaques with histopathology is still lacking. The aim of this study was to characterize atherosclerotic plaque components in a quantitative manner by obtaining the MR signal characteristics (T1, T2, T2*, and proton density) at 7T in ex vivo circle of Willis specimens and using histopathology for validation. MATERIALS AND METHODS: A multiparametric ultra-high-resolution quantitative MR imaging protocol was performed at 7T to identify the MR signal characteristics of different intracranial atherosclerotic plaque components, and using histopathology for validation. In total, 38 advanced plaques were matched between MR imaging and histology, and ROI analysis was performed on the identified tissue components. RESULTS: Mean T1, T2, and T2* relaxation times and proton density values were significantly different between different tissue components. The quantitative T1 map showed the most differences among individual tissue components of intracranial plaques with significant differences in T1 values between lipid accumulation (T1 = 838 ± 167 ms), fibrous tissue (T1 = 583 ± 161 ms), fibrous cap (T1 = 481 ± 98 ms), calcifications (T1 = 314 ± 39 ms), and the intracranial arterial vessel wall (T1 = 436 ± 122 ms). CONCLUSIONS: Different tissue components of advanced intracranial plaques have distinguishable imaging characteristics with ultra-high-resolution quantitative MR imaging at 7T. Based on this study, the most promising method for distinguishing intracranial plaque components is T1-weighted imaging.


Assuntos
Arteriosclerose Intracraniana/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Neuroimagem/métodos , Placa Aterosclerótica/diagnóstico por imagem , Humanos , Placa Aterosclerótica/patologia
17.
NMR Biomed ; 29(9): 1295-304, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-25916399

RESUMO

Thus far, blood flow velocity measurements with MRI have only been feasible in large cerebral blood vessels. High-field-strength MRI may now permit velocity measurements in much smaller arteries. The aim of this proof of principle study was to measure the blood flow velocity and pulsatility of cerebral perforating arteries with 7-T MRI. A two-dimensional (2D), single-slice quantitative flow (Qflow) sequence was used to measure blood flow velocities during the cardiac cycle in perforating arteries in the basal ganglia (BG) and semioval centre (CSO), from which a mean normalised pulsatility index (PI) per region was calculated (n = 6 human subjects, aged 23-29 years). The precision of the measurements was determined by repeated imaging and performance of a Bland-Altman analysis, and confounding effects of partial volume and noise on the measurements were simulated. The median number of arteries included was 14 in CSO and 19 in BG. In CSO, the average velocity per volunteer was in the range 0.5-1.0 cm/s and PI was 0.24-0.39. In BG, the average velocity was in the range 3.9-5.1 cm/s and PI was 0.51-0.62. Between repeated scans, the precision of the average, maximum and minimum velocity per vessel decreased with the size of the arteries, and was relatively low in CSO and BG compared with the M1 segment of the middle cerebral artery. The precision of PI per region was comparable with that of M1. The simulations proved that velocities can be measured in vessels with a diameter of more than 80 µm, but are underestimated as a result of partial volume effects, whilst pulsatility is overestimated. Blood flow velocity and pulsatility in cerebral perforating arteries have been measured directly in vivo for the first time, with moderate to good precision. This may be an interesting metric for the study of haemodynamic changes in aging and cerebral small vessel disease. © 2015 The Authors NMR in Biomedicine Published by John Wiley & Sons Ltd.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Angiografia Cerebral/métodos , Artérias Cerebrais/fisiologia , Circulação Cerebrovascular/fisiologia , Aumento da Imagem/métodos , Angiografia por Ressonância Magnética/métodos , Fluxo Pulsátil/fisiologia , Adulto , Artérias Cerebrais/anatomia & histologia , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Campos Magnéticos , Masculino , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
19.
NMR Biomed ; 28(4): 514-22, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25802216

RESUMO

Lactate levels are measurable by MRS and are related to neural activity. Therefore, it is of interest to accurately measure lactate levels in the basal ganglia networks. If sufficiently stable, lactate measurements may be used to investigate alterations in dopaminergic signalling in the striatum, facilitating the detection and diagnosis of metabolic deficits. The aim of this study is to provide a J-difference editing MRS technique for the selective editing of lactate only, thus allowing the detection of lactate without contamination of overlapping macromolecules. As a validation procedure, macromolecule nulling was combined with J-difference editing, and this was compared with J-difference editing with a new highly selective editing pulse. The use of a high-field (7T) MR scanner enables the application of editing pulses with very narrow bandwidth, which are selective for lactate. We show that, despite the sensitivity to B0 offsets, the use of a highly selective editing pulse is more efficient for the detection of lactate than the combination of a broad-band editing pulse with macromolecule nulling. Although the signal-to-noise ratio of uncontaminated lactate detection in healthy subjects is relatively low, this article describes the test-retest performance of lactate detection in the striatum when using highly selective J-difference editing MRS at 7 T. The coefficient of variation, σw and intraclass correlation coefficients for within- and between-subject differences of lactate were determined. Lactate levels in the left and right striatum were determined twice in 10 healthy volunteers. Despite the fact that the test-retest performance of lactate detection is moderate with a coefficient of variation of about 20% for lactate, these values can be used for the design of new studies comparing, for example, patient populations with healthy controls.


Assuntos
Corpo Estriado/química , Ácido Láctico/análise , Espectroscopia de Ressonância Magnética , Adulto , Ácido Aspártico/análogos & derivados , Ácido Aspártico/análise , Gânglios da Base/química , Colina/análise , Creatina/análise , Humanos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética/estatística & dados numéricos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Razão Sinal-Ruído , Adulto Jovem
20.
AJNR Am J Neuroradiol ; 36(4): 694-701, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25477359

RESUMO

BACKGROUND AND PURPOSE: Several studies have attempted to characterize intracranial atherosclerotic plaques by using MR imaging sequences. However, dedicated validation of these sequences with histology has not yet been performed. The current study assessed the ability of ultra-high-resolution 7T MR imaging sequences with different image contrast weightings to image plaque components, by using histology as criterion standard. MATERIALS AND METHODS: Five specimens of the circle of Wills were imaged at 7T with 0.11 × 0.11 mm in-plane-resolution proton attenuation-, T1-, T2-, and T2*-weighted sequences (through-plane resolution, 0.11-1 mm). Tissue samples from 13 fiducial-marked locations (per specimen) on MR imaging underwent histologic processing and atherosclerotic plaque classification. Reconstructed MR images were matched with histologic sections at corresponding locations. RESULTS: Forty-four samples were available for subsequent evaluation of agreement or disagreement between plaque components and image contrast differences. Of samples, 52.3% (n = 23) showed no image contrast heterogeneity; this group comprised solely no lesions or early lesions. Of samples, 25.0% (n = 11, mostly advanced lesions) showed good correlation between the spatial organization of MR imaging heterogeneities and plaque components. Areas of foamy macrophages were generally seen as proton attenuation-, T2-, and T2*- hypointense areas, while areas of increased collagen content showed more ambiguous signal intensities. Five samples showed image-contrast heterogeneity without corresponding plaque components on histology; 5 other samples showed contrast heterogeneity based on intima-media artifacts. CONCLUSIONS: MR imaging at 7T has the image contrast capable of identifying both focal intracranial vessel wall thickening and distinguishing areas of different signal intensities spatially corresponding to plaque components within more advanced atherosclerotic plaques.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Arteriosclerose Intracraniana/patologia , Imageamento por Ressonância Magnética/métodos , Placa Aterosclerótica/patologia , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA