Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38696675

RESUMO

AIMS: Contact force (CF)-sensing radiofrequency (RF) catheters with an ablation index have shown reproducible outcomes for the treatment of atrial fibrillation (AF) in large multicentre studies. A dual-energy (DE) focal CF catheter to deliver RF and unipolar/biphasic pulsed field ablation (PFA), integrated with a three-dimensional (3D) mapping system, can provide operators with additional flexibility. The SmartfIRE study assessed the safety and efficacy of this novel technology for the treatment of drug-refractory, symptomatic paroxysmal AF. Results at 3 months post-ablation are presented here. METHODS AND RESULTS: Pulmonary vein isolation (PVI) was performed using a DE focal, irrigated CF-sensing catheter with the recommendation of PFA at posterior/inferior and RF ablation at the anterior/ridge/carina segments. Irrespective of energy, a tag size of 3 mm; an inter-tag distance ≤6 mm; a target index of 550 for anterior, roof, ridge, and carina; and a target index of 400 for posterior and inferior were recommended. Cavotricuspid isthmus ablation was permitted in patients with documented typical atrial flutter. The primary effectiveness endpoint was acute procedural success. The primary safety endpoint was the rate of primary adverse events (PAEs) within 7 days of the procedure. A prespecified patient subset underwent oesophageal endoscopy (EE; 72 h post-procedure), neurological assessment (NA; pre-procedure and discharge), and cardiac computed tomography (CT)/magnetic resonance angiogram (MRA) imaging (pre-procedure and 3 months post-procedure) for additional safety evaluation, and a mandatory remapping procedure (Day 75 ± 15) for PVI durability assessment. Of 149 patients enrolled between February and June 2023, 140 had the study catheter inserted (safety analysis set) and 137 had ablation energy delivered (per-protocol analysis set). The median (Q1/Q3) total procedure and fluoroscopy times were 108.0 (91.0/126.0) and 4.2 (2.3/7.7) min (n = 137). The acute procedural success rate was 100%. First-pass isolation was achieved in 89.1% of patients and 96.8% of veins. Cavotricuspid isthmus ablations were successfully performed in 12 patients [pulsed field (PF) only: 6, RF only: 5, and RF/PF: 1]. The PAE rate was 4.4% [6/137 patients; 2 pulmonary vein (PV) stenoses, 2 cardiac tamponades/perforations, 1 stroke, and 1 pericarditis]. No coronary artery spasm was reported. No oesophageal lesion was seen in the EE subset (0/31, 0%). In the NA subset (n = 30), microemboli lesions were identified in 2 patients (2/30, 6.7%), both of which were resolved at follow-up; only 1 was symptomatic (silent cerebral lesion, 3.3%). In the CT/MRA subset (n = 30), severe PV narrowing (of >70%) was detected in 2 patients (2/30, 6.7%; vein level 2/128, 1.6%), of whom 1 underwent dilatation and stenting and 1 was asymptomatic; both were associated with high index values and a small inter-tag distance. In the PV durability subset (n = 30), 100/115 treated PVs (87%) were durably isolated and 18/30 patients (60.0%) had all PVs durably isolated. CONCLUSION: A DE focal CF catheter with 3D mapping integration showed a 100% acute success rate with an acceptable safety profile in the treatment of paroxysmal AF. Prespecified 3-month remapping showed notable PVI durability. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT05752487.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Masculino , Feminino , Ablação por Cateter/métodos , Ablação por Cateter/instrumentação , Pessoa de Meia-Idade , Resultado do Tratamento , Idoso , Imageamento Tridimensional , Cateteres Cardíacos , Fatores de Tempo , Desenho de Equipamento , Estudos Prospectivos , Recidiva
2.
Artigo em Inglês | MEDLINE | ID: mdl-38613544

RESUMO

BACKGROUND: Atrial tachycardia (AT) and atrial fibrillation (AF) coexist in 30% of congenital heart disease (CHD) patients. Successful atrial tachycardia catheter ablation (ATCA) might prevent AF. Data on new-onset AF after ATCA in CHD is scarce. OBJECTIVES: This study aimed to evaluate the incidence of new-onset AF after ATCA and to assess clinical characteristics associated with new-onset AF after ATCA in CHD. METHODS: CHD patients referred for ATCA to 3 European centers were included. New occurrence of AF was defined as electrocardiographic documentation of AF after any ATCA procedure in patients without history of AF. RESULTS: In 277 CHD patients (median age 37 years [Q1, Q3: 23, 49 years], 58% men, 59 [21%] simple, 111 [40%] moderate, and 107 [39%] complex CHD), AF occurred in 25 patients (9%) a median of 8 months (Q1, Q3: 4, 27 months) after ATCA. New-onset AF was persistent in the majority of the patients (17 of 25 [63%]). Patients with new-onset AF were older (44 years [Q1, Q3: 29, 55 years] vs 36 years [Q1, Q3: 23, 49 years]; P = 0.009) and more frequently had simple CHD (13 of 25 [52%] vs 46 of 252 [18%], respectively; P < 0.0001). Acute ATCA success rates were similar in patients with and without AF (52% vs 48%; P = 0.429). Simple CHD was an independent predictor of new-onset AF during follow-up. CONCLUSIONS: In our large cohort of patients with congenital heart disease, new-onset AF after ablation for AT occurred in only 9% of the patients. AF occurred without AT recurrence and was persistent in the majority of patients.

3.
JACC Clin Electrophysiol ; 10(4): 637-650, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38276927

RESUMO

BACKGROUND: Voltage mapping to detect ventricular scar is important for guiding catheter ablation, but the field-of-view of unipolar, bipolar, conventional, and microelectrodes as it relates to the extent of viable myocardium (VM) is not well defined. OBJECTIVES: The purpose of this study was to evaluate electroanatomic voltage-mapping (EAVM) with different-size electrodes for identifying VM, validated against high-resolution ex-vivo cardiac magnetic resonance (HR-LGE-CMR). METHODS: A total of 9 swine with early-reperfusion myocardial infarction were mapped with the QDOT microcatheter. HR-LGE-CMR (0.3-mm slices) were merged with EAVM. At each EAVM point, the underlying VM in multisize transmural cylinders and spheres was quantified from ex vivo CMR and related to unipolar and bipolar voltages recorded from conventional and microelectrodes. RESULTS: In each swine, 220 mapping points (Q1, Q3: 216, 260 mapping points) were collected. Infarcts were heterogeneous and nontransmural. Unipolar and bipolar voltage increased with VM volumes from >175 mm3 up to >525 mm3 (equivalent to a 5-mm radius cylinder with height >6.69 mm). VM volumes in subendocardial cylinders with 1- or 3-mm depth correlated poorly with all voltages. Unipolar voltages recorded with conventional and microelectrodes were similar (difference 0.17 ± 2.66 mV) and correlated best to VM within a sphere of radius 10 and 8 mm, respectively. Distance-weighting did not improve the correlation. CONCLUSIONS: Voltage increases with transmural volume of VM but correlates poorly with small amounts of VM, which limits EAVM in defining heterogeneous scar. Microelectrodes cannot distinguish thin from thick areas of subendocardial VM. The field-of-view for unipolar recordings for microelectrodes and conventional electrodes appears to be 8 to 10 mm, respectively, and unexpectedly similar.


Assuntos
Infarto do Miocárdio , Animais , Suínos , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Gadolínio , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Técnicas Eletrofisiológicas Cardíacas/métodos , Microeletrodos , Eletrodos , Miocárdio/patologia , Meios de Contraste
4.
Int J Pharm ; 634: 122627, 2023 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-36693484

RESUMO

Nilotinib is a selective tyrosine-kinase inhibitor approved for the treatment of chronic myeloid leukemia. It is poorly soluble in aqueous media and has a low oral bioavailability. Nilotinib encapsulation into yeast glucan particles (GPs) was investigated in this work as a means of increasing bioavailability. The amorphization of nilotinib in GPs resulted in an increased dissolution rate, which was confirmed by in vitro experiments using biorelevant dissolution media. Simultaneously, GPs containing nilotinib were effectively taken up by macrophages, which was quantified in vitro on cell cultures. The overall oral bioavailability in a rat model was approximately 39 % for nilotinib delivered in a reference formulation (Tasigna) and was almost doubled when delivered in GPs. The contribution of glucan particles to the lymphatic transport of nilotinib was quantified. When delivered by GPs, cumulative nilotinib absorption via the lymphatic system increased by a factor of 10.8 compared to the reference, but still represented arelative bioavailability of only 1.12 %. The cumulative uptake of GPs in the lymph was found to be 0.54 mg after a single dose of 50 mg. Yeast glucan particles can therefore serve as a drug delivery vehicle with a dual function: dissolution rate enhancement by amorphization, and, to asmaller extent, lymphatic delivery due to macrophage uptake.


Assuntos
Glucanos , Saccharomyces cerevisiae , Ratos , Animais , Pirimidinas , Administração Oral
5.
J Interv Card Electrophysiol ; 63(3): 699-707, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35022997

RESUMO

BACKGROUND: Contact force (CF)-guided catheter ablation (CA) is a novel technology developed to improve efficacy and reduce complications. In a randomised controlled trial (RCT), we previously documented that after 3 months, rate of persistent conduction block was similar with and without using CF while performing CA for typical atrial flutter (AFL). Clinical effect of CF on recurrent arrhythmia is unknown. Our objective is to study recurrent atrial arrhythmia during 12-month follow-up in a RCT investigating whether CF-guided CA for typical AFL is superior to CF-blinded CA. METHODS: Patients were randomised 1:1 to CA guided by CF (intervention group) or blinded to CF (control group). After 12 months, patients attended clinical check-up preceded by a 5-day ambulatory Holter monitor recording. Primary outcome was any recurrent atrial arrhythmia ≥ 30 s within 12 months and documented in 12-lead ECG or Holter monitor recording. RESULTS: We included 156 patients, four patients withdrew consent and two died during follow-up. Thus, 150 patients were included in final analysis. Recurrent arrhythmia was detected in 36 of 77 (47%) patients in the intervention group, and 32 of 73 patients (44%) in the control group (p = 0.51). Atrial fibrillation was detected in 23 (30%) and 29 (40%) patients in the intervention and control groups respectively. AFL was detected in 11 (14%) and 5 (7%) patients in the intervention and control groups respectively. CONCLUSIONS: Contact force-guided ablation for typical atrial flutter does not reduce recurrent atrial arrhythmia after 12-month follow-up as compared with ablation blinded for contact force.


Assuntos
Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Fibrilação Atrial/cirurgia , Flutter Atrial/cirurgia , Eletrocardiografia , Humanos , Resultado do Tratamento
6.
J Atr Fibrillation ; 13(6): 20200460, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34950350

RESUMO

BACKGROUND: A novel QDOT MICRO (Biosense Webster, Inc., Irvine, CA) catheter with optimized temperature control and microelectrodes was designed to incorporate real-time temperature sensing with contact force detection and microelectrodes to streamline ablation workflow. The QDOT-MICRO feasibility study evaluated the workflow, performance, and safety of temperature-controlled catheter ablation in patients with symptomatic paroxysmal atrial fibrillation with conventional ablation setting. METHODS: This was a non-randomized, single-arm, first-in-human study. The primary outcome was pulmonary vein isolation (PVI), confirmed by entrance block after adenosine and/or isoproterenol challenge. Safety outcomes included incidences of early-onset primary adverse events (AEs) and serious adverse device effects (SADEs). Device performance was evaluated via physician survey. RESULTS: All evaluated patients (n = 42) displayed 100% PVI. Two primary AEs (4.8%) were reported: 1 pericarditis and 1 vascular pseudoaneurysm. An additional SADE of localized infection was reported in 1 patient. No stroke, patient deaths, or other unanticipated AEs were reported. Average power delivered was 32.1±4.1 W, with a mean temperature of 40.8°C±1.6°C. Mean procedure (including 20-minute wait), fluoroscopy, and radiofrequency application times were 129.8, 6.7, and 34.0 minutes, respectively. On device performance, physicians reported overall satisfactory performance with the new catheter, with highest scores for satisfaction and usefulness of the temperature indicator. CONCLUSIONS: Initial clinical experience with the novel catheter showed 100% acute PVI success and acceptable safety and device performance in temperature-controlled ablation mode. There were no deaths, stroke, or unanticipated AEs. Fluoroscopy and procedural times were short and similar or better than reported for prior generation catheters.

8.
Br J Pharmacol ; 178(23): 4663-4674, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34365639

RESUMO

BACKGROUND AND PURPOSE: Lymphatic transport of drugs after oral administration is an important mechanism for absorption of highly lipophilic compounds. Direct measurement in lymph duct cannulated animals is the gold standard method, but non-invasive cycloheximide chylomicron flow blocking method has gained popularity recently. However, concerns about its reliability have been raised. The aim of this work was to investigate the validity of cycloheximide chylomicron flow blocking method for the evaluation of lymphatic transport using model compounds with high to very high lipophilicity, that is, abiraterone and cinacalcet. EXPERIMENTAL APPROACH: Series of pharmacokinetic studies were conducted with abiraterone acetate and cinacalcet hydrochloride after enteral/intravenous administration to intact, lymph duct cannulated and/or cycloheximide pre-treated rats. KEY RESULTS: Mean total absolute oral bioavailability of abiraterone and cinacalcet was 7.0% and 28.7%, respectively. There was a large and significant overestimation of the lymphatic transport extent by the cycloheximide method. Mean relative lymphatic bioavailability of abiraterone and cinacalcet in cycloheximide method was 28-fold and 3-fold higher than in cannulation method, respectively. CONCLUSION AND IMPLICATIONS: Cycloheximide chylomicron flow blocking method did not provide reliable results on lymphatic absorption and substantially overestimated lymphatic transport for both molecules, that is, abiraterone and cinacalcet. This non-invasive method should not be used for the assessment of lymphatic transport and previously obtained data should be critically revised.


Assuntos
Quilomícrons , Absorção Intestinal , Administração Oral , Animais , Disponibilidade Biológica , Transporte Biológico , Quilomícrons/metabolismo , Cicloeximida/farmacologia , Preparações Farmacêuticas , Ratos , Reprodutibilidade dos Testes
9.
Dan Med J ; 68(4)2021 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-33829990

RESUMO

INTRODUCTION: Radiofrequency catheter ablation (RFA) is the treatment of choice for a variety of cardiac arrhythmias in adults. RFA is considered effective and is associated with few complications. We aimed to review the characteristics and outcomes of invasive electrophysiological study (EPS) and RFA in children with supraventricular tachyarrhythmia. METHODS: Consecutive patients younger than 16 years of age undergoing EPS and possible RFA from January 2009 to September 2018 at Aarhus University Hospital (uptake three million people) were reviewed retrospectively. Procedural and outcome data were collected from patient charts and from the Danish Ablation Database. Numbers (%) or median (range) are reported. RESULTS: A total of 304 patients (148 girls) underwent EPS (352 procedures). RFA was performed in 246 patients (279 procedures), aged 13 (1-15) years and weighing 46 (6-99) kg. Treatment success was achieved in 195 (79%) of the initial procedures. Using more than one procedure, 227 (92%) patients were free from arrhythmia after 89 (26-143) months of follow-up. The procedure time was 60 (22-222) min. and ablation time 2 (1-23) min. Major complications occurred in two cases. One patient developed transient superior vena cava syndrome and one patient developed an atrioventricular block requiring pacemaker implantation. CONCLUSIONS: RFA may be performed in children with a high success rate and a low but not negligible risk of complications. FUNDING: none. TRIAL REGISTRATION: Approval was obtained from the Danish Data Protection Agency (1-16-02-430-13).


Assuntos
Ablação por Cateter , Síndrome da Veia Cava Superior , Taquicardia Supraventricular , Adolescente , Arritmias Cardíacas , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Estudos Retrospectivos , Taquicardia Supraventricular/cirurgia , Resultado do Tratamento
10.
Bosn J Basic Med Sci ; 21(1): 61-70, 2021 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-31782696

RESUMO

The study presents a novel vancomycin-releasing collagen wound dressing derived from Cyprinus carpio collagen type I cross-linked with carbodiimide which retarded the degradation rate and increased the stability of the sponge. Following lyophilization, the dressings were subjected to gamma sterilization. The structure was evaluated via scanning electron microscopy images, micro-computed tomography, and infrared spectrometry. The structural stability and vancomycin release properties were evaluated in phosphate buffered saline. Microbiological testing and a rat model of a wound infected with methicillin-resistant Staphylococcus aureus (MRSA) were then employed to test the efficacy of the treatment of the infected wound. Following an initial mass loss due to the release of vancomycin, the sponges remained stable. After 7 days of exposure in phosphate buffered saline (37°C), 60% of the material remained with a preserved collagen secondary structure together with a high degree of open porosity (over 80%). The analysis of the release of vancomycin revealed homogeneous distribution of the antibiotic both across and between the sponges. The release of vancomycin was retarded as proved by in vitro testing and further confirmed by the animal model from which measurable concentrations were observed in blood samples 24 hours after the subcutaneous implantation of the sponge, which was more than observed following intraperitoneal administration. The sponge was also highly effective in terms of reducing the number of colony-forming units in biopsies extracted from the infected wounds 4 days following the inoculation of the wounds with the MRSA solution. The presented sponges have ideal properties to serve as wound dressing for prevention of surgical site infection or treatment of already infected wounds.


Assuntos
Antibacterianos/farmacocinética , Staphylococcus aureus Resistente à Meticilina/efeitos dos fármacos , Vancomicina/farmacocinética , Cicatrização/efeitos dos fármacos , Animais , Bandagens , Carbodi-Imidas/farmacocinética , Carpas , Colágeno/farmacocinética , Ratos
11.
Scand Cardiovasc J ; 55(1): 29-34, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33073633

RESUMO

OBJECTIVES: We aimed to investigate the predictors of recurrent arrhythmia after repeated pulmonary vein isolation (PVI) performed in the era of contact force without additional substrate ablation. One of the predictors studied, ablation index (AI), incorporates power, contact force, and time in a weighted formula and is reported to predict lesion size in animals. Design. Consecutive patients (n = 108) undergoing repeat PVI without additional substrate modification using a contact force sensing catheter were included retrospectively at a tertiary center. All ablation points were analyzed offline. A new variable, normalized AI (AI corrected for the location of the lesion-anterior vs. posterior) was calculated. The patients were systematically followed with clinical visit and 12-lead ECG as well as review of the regional electronic patient files at 3 and 12 months after the procedure with 5-day Holter at 12 months. Results. Electrical reconnection to at least one pulmonary vein (PV) was seen in 97% of the patients. The recurrence rate was 35%. There was no recurrence in patients with nAI above 1.15 (n = 26). Patients with electrical reconnection of up to two PVs had a higher risk of recurrence compared with patients having electrical reconnection of three or four PVs (p = .003), and this risk was especially high in patients with persistent atrial fibrillation (69 [39-91]%). Conclusions. The risk of recurrence is higher in patients with ablations performed with low levels of AI and in patients with reconnection to up to two PVs. Our data may indicate the need for higher target levels of AI during repeat PVI than normally used during de-novo PVI.


Assuntos
Fibrilação Atrial , Veias Pulmonares , Arritmias Cardíacas/epidemiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Humanos , Veias Pulmonares/cirurgia , Recidiva , Estudos Retrospectivos , Medição de Risco
12.
Biomed Res Int ; 2020: 3841861, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33123572

RESUMO

OBJECTIVES: Surgical wounds resulting from biofilm-producing microorganisms represent a major healthcare problem that requires new and innovative treatment methods. Rifampin is one of a small number of antibiotics that is able to penetrate such biofilms, and its local administration has the potential to serve as an ideal surgical site infection protection and/or treatment agent. This paper presents two types (homogeneous and sandwich structured) of rifampin-releasing carbodiimide-cross-linked fresh water fish collagen wound dressings. METHODS: The dressings were prepared by means of the double-lyophilization method and sterilized via gamma irradiation so as to allow for testing in a form that is able to serve for direct clinical use. The mechanical properties were studied via the uniaxial tensile testing method. The in vivo rifampin-release properties were tested by means of a series of incubations in phosphate-buffered saline. The microbiological activity was tested against methicillin-resistant staphylococcus aureus (MRSA) employing disc diffusion tests, and the in vivo pharmacokinetics was tested using a rat model. A histological examination was conducted for the study of the biocompatibility of the dressings. RESULTS: The sandwich-structured dressing demonstrated better mechanical properties due to its exhibiting ability to bear a higher load than the homogeneous sponges, a property that was further improved via the addition of rifampin. The sponges retarded the release of rifampin in vitro, which translated into at least 22 hours of rifampin release in the rat model. This was significantly longer than was achieved via the administration of a subcutaneous rifampin solution. Microbiological activity was proven by the results of the disc diffusion tests. Both sponges exhibited excellent biocompatibility as the cells penetrated into the scaffold, and virtually no signs of local irritation were observed. CONCLUSIONS: We present a novel rifampin-releasing sandwich-structured fresh water fish collagen wound dressing that has the potential to serve as an ideal surgical site infection protection and/or treatment agent.


Assuntos
Colágeno/farmacologia , Rifampina/farmacologia , Cicatrização/efeitos dos fármacos , Animais , Antibacterianos/farmacologia , Bandagens , Biofilmes/efeitos dos fármacos , Peixes/metabolismo , Água Doce , Masculino , Staphylococcus aureus Resistente à Meticilina/efeitos dos fármacos , Ratos , Ratos Wistar , Infecção da Ferida Cirúrgica/tratamento farmacológico
13.
Europace ; 22(6): 947-955, 2020 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-32298418

RESUMO

AIMS: Contact force (CF) sensing has emerged as a tool to guide and improve outcomes for catheter ablation (CA) for cardiac arrhythmias. The clinical benefit on patient outcomes remains unknown. To study whether CF-guided CA for typical atrial flutter (AFL) is superior to CA not guided by CF. METHODS AND RESULTS: In a double-blinded controlled superiority trial, we randomized patients 1:1 to receive CA for typical AFL guided by CF (intervention group) or blinded to CF (control group). In the intervention group, a specific value of the lesion size index (LSI), estimating ablation lesions size was targeted for each ablation lesion. Patients underwent electrophysiological study (EPS) after 3 months to assess occurrence of the primary endpoint of re-conduction across the cavo-tricuspid isthmus (CTI). We included 156 patients with typical AFL, median age was 68 [interquartile range (IQR) 61-74] years and 120 (77%) patients were male. At index procedure median LSI was higher in the intervention group [6.4 (IQR 5.1-7) vs. 5.6 (IQR 4.5-6.9), P < 0.0001]. After 3 months, 126 patients (58 in intervention group) underwent EPS for primary endpoint assessment. Thirty (24%) patients had CTI re-conduction, distributed with 15 patients in each treatment group (P = 0.62). We observed no difference between treatment groups with regard to fluoroscopy, ablation, or procedure times, nor peri-procedural complications. CONCLUSION: Contact force-guided ablation does not reduce re-conduction across the CTI after 3 months, nor does CF-guided ablation shorten fluoroscopy, ablation, or total procedure times.


Assuntos
Flutter Atrial , Ablação por Cateter , Idoso , Flutter Atrial/diagnóstico , Flutter Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Fluoroscopia , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
14.
Int J Cardiol ; 298: 44-51, 2020 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-31521436

RESUMO

BACKGROUND: Cavo tricuspid isthmus ablation (CTIA) is considered an effective first-line treatment for typical atrial flutter (AFL). However, many patients develop atrial fibrillation (AF) after successful CTIA. Knowledge about recurrent arrhythmia after CTIA mainly comes from small cohort studies with limited follow-up. OBJECTIVE: To describe incidences of re-ablation for AFL and ablation for AF after first-time CTIA in a nation-wide cohort. METHODS: In the Danish National Ablation Registry we identified patients undergoing first-time CTIA during 2010-2016. Subsequent CTIA and AF-ablation procedures were identified until March 1st, 2018. We collected information on patient comorbidities in the Danish National Patient Registry. RESULTS: We identified 2409 patients undergoing first-time CTIA. Median age was 66 (IQR 58-72) years, 1952 (81%) were men, and 78 (3%) patients had a history of previous ablation for AF. Acute procedural success was achieved in 2288 (95%) patients. During mean follow-up of 4.0 ±â€¯1.7 years, 242 (10%) patients underwent CTI re-ablation and 326 (13.5%) underwent ablation for AF. Baseline characteristics associated with CTI re-ablation included prolonged procedural time, unsuccessful index CTIA, age <75 years and CHA2DS2-VASc score <2. Hypertension, history of AF-ablation, age <65 years use of a contact force sensing catheter and CHA2DS2-VASc score <2 were associated with later ablation for AF. CONCLUSION: In a nation-wide cohort undergoing first-time CTIA for AFL, 10% of patients underwent CTI re-ablation and 13.5% ablation for AF during mean follow-up of 4.0 ±â€¯1.7 years. Probability of a second procedure was higher in younger patients with less comorbidities.


Assuntos
Fibrilação Atrial/epidemiologia , Flutter Atrial/epidemiologia , Flutter Atrial/cirurgia , Ablação por Cateter/tendências , Idoso , Fibrilação Atrial/diagnóstico , Flutter Atrial/diagnóstico , Ablação por Cateter/efeitos adversos , Estudos de Coortes , Dinamarca/epidemiologia , Feminino , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Recidiva , Estudos Retrospectivos
15.
JACC Clin Electrophysiol ; 5(10): 1130-1140, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31648737

RESUMO

OBJECTIVES: This study sought to evaluate the value of combined electrogram (EGM) information provided by simultaneous mapping using micro- and conventional electrodes in the identification of post-myocardial infarction ventricular tachycardia substrate. BACKGROUND: Ventricular tachycardias after myocardial infarction are related to scars with complex geometry. Scar delineation and ventricular tachycardia substrate identification relies on bipolar voltages (BV) and EGM characteristics. Early reperfusion therapy results in small, nontransmural scars, the details of which may not be delineated using 3.5 mm tip catheters. METHODS: Nine swine with early reperfusion myocardial infarction were mapped using Biosense Webster's QDOT Micro catheter, incorporating 3 microelectrodes at the tip of the standard 3.5 mm electrode. Analysis of EGM during sinus rhythm, right ventricular pacing, and short-coupled right ventricular extrastimuli was performed. The swine were sacrificed and mapping data were projected onto the heart. Transmural biopsies (n = 196) corresponding to mapping points were obtained, allowing a head-to-head comparison of EGM recorded by micro- and conventional electrodes with histology. RESULTS: To identify scar areas using standard electrodes, unique cutoff values of unipolar voltage <5.44 mV, BV <1.27 mV (conventional), and BV <2.84 mV (microelectrode) were identified. Combining the information provided by unipolar voltage and BV mapping, the sensitivity of scar identification was increased to 93%. Micro-EGM were better able to distinguish small near-fields corresponding to a layer of viable subendocardium than conventional EGM were. CONCLUSIONS: The combined information provided by multisize electrode mapping increases the sensitivity with which areas of scar are identified. EGM from microelectrodes, with narrower spacing, allow identification of near-fields arising from thin subendocardial layer and layers activated with short delay obscured in EGM from conventional mapping catheter.


Assuntos
Cardiomiopatias/fisiopatologia , Cicatriz/fisiopatologia , Técnicas Eletrofisiológicas Cardíacas/métodos , Isquemia Miocárdica/fisiopatologia , Taquicardia Ventricular/fisiopatologia , Animais , Cardiomiopatias/complicações , Cardiomiopatias/patologia , Cicatriz/etiologia , Cicatriz/patologia , Eletrodos , Endocárdio/fisiopatologia , Isquemia Miocárdica/complicações , Isquemia Miocárdica/patologia , Suínos , Taquicardia Ventricular/etiologia
16.
Europace ; 21(12): 1919-1927, 2019 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-31545375

RESUMO

AIMS: Contact force (CF) between radiofrequency (RF) ablation catheter and myocardium and ablation index (AI) correlates with RF lesion depth and width in normal-voltage (>1.5 mV) myocardium (NVM). We investigate the impact of CF on RF lesion depth and width in low (<0.5 mV) (LVM) and intermediate-voltage (0.5-1.5 mV) myocardium (IVM) following myocardial infarction. Correlation between RF lesion depth and width evaluated by native contrast magnetic resonance imaging (ncMRI) and gross anatomical evaluation was investigated. METHODS AND RESULTS: Twelve weeks after myocardial infarction, 10 pigs underwent electroanatomical mapping and endocardial RF ablations were deployed in NVM, IVM, and LVM myocardium. In vivo ncMRI was performed before the heart was excised and subjected to gross anatomical evaluation. Ninety (82%) RF lesions were evaluated. Radiofrequency lesion depth and width were smaller in IVM and LVM compared with NVM (P < 0.001). Radiofrequency lesion depth and width correlated with CF, AI, and impedance drop in NVM (CF and AI P < 0.001) and IVM (CF and AI depths P < 0.001; CF and AI widths P < 0.05). Native contrast magnetic resonance imaging evaluated RF lesion depth and width correlated with gross anatomical depth and width (NVM and IVM P < 0.001; LVM P < 0.05). CONCLUSIONS: Radiofrequency lesions deployed by similar duration, power and CF are smaller in IVM and LVM than in NVM. Radiofrequency lesion depth and width correlated with CF, AI, and impedance drop in NVM and IVM but not in LVM. Native contrast magnetic resonance imaging may be useful to assess RF lesion depth and width in NVM, IVM, and LVM.


Assuntos
Ablação por Cateter/métodos , Cicatriz/fisiopatologia , Coração/diagnóstico por imagem , Infarto do Miocárdio/fisiopatologia , Miocárdio/patologia , Taquicardia Ventricular/cirurgia , Animais , Procedimentos Cirúrgicos Cardíacos , Cicatriz/diagnóstico por imagem , Cicatriz/patologia , Impedância Elétrica , Técnicas Eletrofisiológicas Cardíacas , Imageamento por Ressonância Magnética , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/patologia , Recidiva , Sus scrofa , Suínos , Taquicardia Ventricular/fisiopatologia , Falha de Tratamento
18.
Biomed Res Int ; 2019: 5301405, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30941365

RESUMO

AIM: To assess the systemic and local immunological response to subcutaneous implants of a vascular graft covered with collagen extracted from the European carp (freshwater fish) or with collagen of bovine origin. METHODS: Pieces of a vascular graft covered by pure bovine (Bos taurus, BOV, n=14) or carp (Cyprinus carpio, CYP, n=14) collagen 5 mm in size were implanted subcutaneously in the dorsum of a Balb/cOla mice. A sham operation group of 12 animals served as the control. At 7 and 14 days after the operation, one-half of each group was terminated and blood for serum, spleen, and implant with surrounding tissue were collected. Mean cytokine (TNF-α, IL-10, IL-4, IL-1ß, IL-13, and IFN-γ) levels in serum were determined using ELISA. Spleen cell cultures were used for in vitro testing of lymphocyte proliferation and cytokine secretion. Local expressions of IL-6, IL-10, TNF-α, TGF-ß, CCL-2, and CCL-3 were determined using PCR. RESULTS: We found no significant difference among control, BOV, and CYP groups in mean cytokine serum levels at seven days. At day 14, the BOV group had higher levels of TNF-α (P=.018) and both the BOV and CYP groups had lower levels of IL-4 (P=.011 and P=.047, respectively) compared with the control group. Both tested implants showed only a minimal effect on the production of selected cytokines. Cell proliferation in the CYP group stimulated by CYP gel at 14 days was significantly lower than by BOV gel in BOV group (P=.0031) or by CYP gel in the control group (P=.041). The difference between the groups in the local RNA expression of all the tested mediators both at 7 and at 14 days was not significant apart from a lower level of TNF-α in the BOV group compared to CYP at 14 days (P=.013). CONCLUSIONS: Implants covered with carp collagen induce an immunological response that is comparable to that of bovine collagen covered implants in a mouse model.


Assuntos
Prótese Vascular , Colágeno/imunologia , Animais , Carpas , Bovinos , Proliferação de Células , Microambiente Celular , Citocinas/sangue , Camundongos Endogâmicos BALB C , RNA Mensageiro/genética , RNA Mensageiro/metabolismo , Baço/citologia
19.
Scand Cardiovasc J ; 53(3): 133-140, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31032647

RESUMO

Objectives. Left atrial flutter has been reported in up to 10% of patients following pulmonary vein isolation or cardiac surgery. Left atrial flutter is typically highly symptomatic, responds poorly to medical antiarrhythmic treatment, and is often treated by catheter ablation. We aimed to investigate midterm freedom from recurrent arrhythmia after catheter ablation for left atrial flutter. Design. In the National Danish Ablation Registry, we identified consecutive patients, who had undergone catheter ablation for left atrial flutter between 1 January 2014 and 1 April 2017 at our centre. Results. A total of 53 patients (median age 68 years (IQR 60-71) 37 (70%) male) were included. Forty-two patients had prior left atrial catheter ablation procedures (79%), one patient prior ablation for classic atrial flutter (2%), four patients had prior surgery for congenital heart disease (8%), and six patients (11%) had no previous cardiac intervention. Acute procedural success, defined as non-inducibility of any atrial arrhythmia, was achieved in 45 of 53 patients (85%). During midterm follow-up (mean 20 ± 12 months), 26 patients experienced an episode of recurrent atrial arrhythmia. Median EHRA-score was 3 (range 2-4) before catheter ablation and reduced to median 1 (range 1-3) evaluated at follow-up visits after three and twelve months (both p < .001, Wilcoxon rank test). Conclusion. Left atrial flutter is preceded by catheter ablation or cardiac surgery in 89% of patients. Acute procedural success is achieved in majority of patients and ablation reduces symptoms effectively. During midterm follow-up, almost half the patients experience recurrent atrial arrhythmia.


Assuntos
Flutter Atrial/cirurgia , Ablação por Cateter , Idoso , Flutter Atrial/diagnóstico , Flutter Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Dinamarca , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
20.
JACC Clin Electrophysiol ; 4(3): 307-315, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-30089555

RESUMO

OBJECTIVES: The authors conducted a multicenter study of decrement-evoked potential (DEEP)-based functional ventricular tachycardia (VT) substrate modification to evaluate if such a mechanistic and physiological strategy is feasible and efficient in clinical practice and provides reduction in the VT burden. BACKGROUND: Only a fraction of the myocardium targeted in current VT substrate modification procedures is involved in the initiation and perpetuation of VT. The physiological basis of the DEEP strategy for identification of areas of initiation and maintenance of VT was recently established. METHODS: We included 20 consecutive patients with ischemic cardiomyopathy. During substrate mapping, fractionated and late potentials (LPs) were tagged, and an extra stimulus was performed to determine which LPs displayed decrement (DEEPs). All patients underwent DEEP-focused ablation: elimination of DEEP + further radiofrequency (RF) if VT was still inducible. Patients were followed during 6 months. RESULTS: Patients were predominantly male (95%), and their mean age was 64.6 ± 17.1 years. Mean left ventricular ejection fraction was 33.4 ± 11.4%. Mean ablation time was 30.6 ± 20.4 min. Specificity of DEEPs to detect the isthmus of VT was better than that of LPs (0.97 [95% confidence interval [CI]: 0.95 to 0.98] vs. 0.82 [95% CI: 0.73 to 0.89]), without significant differences in terms of sensitivity (0.61 [95% CI: 0.52 to 0.69] vs. 0.60 [95% CI: 0.44 to 0.74], respectively). Fifteen of 20 (75%) patients were free of any VT after DEEP-RF at 6 months of follow-up and there was a strong reduction in VT burden compared to 6 months pre-ablation. CONCLUSIONS: In a multicenter prospective study, DEEP substrate mapping identified the functional substrate critical to the VT circuit with high specificity. DEEP-guided VT ablation, by its physiological nature, may enable greater access to focused ablation therapy for patients requiring VT treatment.


Assuntos
Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas/métodos , Taquicardia Ventricular , Idoso , Idoso de 80 Anos ou mais , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Ablação por Cateter/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica , Estudos Prospectivos , Cirurgia Assistida por Computador , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/epidemiologia , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/cirurgia