Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 109
Filtrar
1.
Clin Chem Lab Med ; 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38726766

RESUMO

OBJECTIVES: This study aimed to evaluate discrepancies in potassium measurements between point-of-care testing (POCT) and central laboratory (CL) methods, focusing on the impact of hemolysis on these measurements and its impact in the clinical practice in the emergency department (ED). METHODS: A retrospective analysis was conducted using data from three European university hospitals: Technische Universitat Munchen (Germany), Hospital Universitario La Paz (Spain), and Erasmus University Medical Center (The Netherlands). The study compared POCT potassium measurements in EDs with CL measurements. Data normalization was performed in categories for potassium levels (kalemia) and hemolysis. The severity of discrepancies between POCT and CL potassium measurements was assessed using the reference change value (RCV). RESULTS: The study identified significant discrepancies in potassium between POCT and CL methods. In comparing POCT normo- and mild hypokalemia against CL results, differences of -4.20 % and +4.88 % were noted respectively. The largest variance in the CL was a +4.14 % difference in the mild hyperkalemia category. Additionally, the RCV was calculated to quantify the severity of discrepancies between paired potassium measurements from POCT and CL methods. The overall hemolysis characteristics, as defined by the hemolysis gradient, showed considerable variation between the testing sites, significantly affecting the reliability of potassium measurements in POCT. CONCLUSIONS: The study highlighted the challenges in achieving consistent potassium measurement results between POCT and CL methods, particularly in the presence of hemolysis. It emphasised the need for integrated hemolysis detection systems in future blood gas analysis devices to minimise discrepancies and ensure accurate POCT results.

2.
Front Mol Biosci ; 11: 1371426, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38572446

RESUMO

Background: During the last decade, Germany has seen an increased prevalence and a redistribution from undetected to diagnosed diabetes mellitus. Due to this substantial epidemiological development, the number of people with documented type 2 diabetes was 8.7 million in 2022. An estimated two million undiagnosed subjects are to be added. Beyond that, the life expectancy of diabetic subjects is increasing due to more responsive health systems in terms of care. Possible reasons include improved screening of at-risk individuals, the introduction of HbA1c for diagnosis in 2010, and the higher use of risk scores. Additionally, quality aspects of the laboratory methodology should be taken into consideration. Methods: Epidemiology and clinical management of diabetes in Germany are presented in the light of publications retrieved by a selective search of the PubMed database. Additionally, the data from German external quality assessment (EQA) surveys for the measurands glucose in plasma and HbA1c in whole blood, reviewed from 2010 until 2022, were evaluated. Above this, data concerning the analytical performance of near-patient glucometer devices, according to the ISO norm 15197:2013, were analyzed. Results: Two laboratory aspects are in good accordance with the observation of an increase in the diabetes mellitus prevalence when retrospectively reviewing the period 2010 to 2022: First, the analytical performance according to the ISO norm 15197:2013 of the glucometer devices widely used by patients with diabetes for the glucose self-testing, has improved during this period. Secondly, concerning the EQA program of INSTAND, the number of participating laboratories raised significantly in Germany. The spreads of variations of the specified results for plasma glucose remained unchanged between 2010 and 2022, whereas for HbA1c a significant decrease of the result scattering could be observed. Conclusion: These retrospectively established findings testify to an excellent analytical quality of laboratory diagnostics for glucose and HbA1c throughout Germany which may be involved in a better diagnosis and therapy of previously undetected diabetes mellitus.

3.
Front Mol Biosci ; 11: 1345356, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38357630

RESUMO

As hormonal disorders are linked to several diseases, the accurate quantitation of steroid hormone levels in serum is crucial in order to provide patients with a reliable diagnosis. Mass spectrometry-based methods are regarded as having the highest level of specificity and sensitivity. However, immunoassays are more commonly used in routine diagnostics to measure steroid levels as they are more cost effective and straightforward to conduct. This study analyzes the external quality assessment results for the measurement of testosterone, progesterone and 17ß-estradiol in serum using immunoassays between early 2020 and May 2022. As reference measurement procedures are available for the three steroid hormones, the manufacturer-specific biases were normalized to the reference measurement values. The manufacturer-specific coefficients of variation were predominantly inconspicuous, below 20% for the three hormones when outliers are disregarded, however there were large differences between the various manufacturer collectives. For some collectives, the median bias to the respective reference measurement value was repeatedly greater than ±35%, which is the acceptance limit defined by the German Medical Association. In the case of testosterone and progesterone determination, some collectives tended to consistently over- or underestimate analyte concentrations compared to the reference measurement value, however, for 17ß-estradiol determination, both positive and negative biases were observed. This insufficient level of accuracy suggests that cross-reactivity continues to be a fundamental challenge when antibody detection is used to quantify steroids with a high structural similarity. Distinct improvements in standardization are required to provide accurate analysis and thus, reliable clinical interpretations. The increased accuracy of the AX immunoassay for testosterone measurement, as observed in the INSTAND EQAs between 2020 and 2022, could be the result of a recalibration of the assay and raises hope for further improvement of standardization of immunoassay-based steroid hormone analyses in the coming years.

4.
J Thromb Haemost ; 22(4): 1187-1201, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38184205

RESUMO

BACKGROUND: Current assays for the detection of (allo)antibodies to platelet antigens are often laborious and widely based on the presence of well-characterized donor platelets. OBJECTIVES: To develop an easy-to-perform, sensitive, and specific test for the detection of antibodies against platelet antigens, in particular, glycoprotein (GP) antigens, called "Recombinantly Expressed Tagged SUrface Protein" (RETSUP) assay, which does not require donor platelets. METHODS: Twin-Strep-tagged GP complexes were recombinantly expressed in human embryonic kidney 293 cells after stable transfection. These cell lines were used as antigen sources in the RETSUP assay, combining cell-based and enzyme-linked immunosorbent assay-based assay procedures. The assay performance was tested with recombinant antibodies, anti-human platelet antigen (HPA) reference plasmas, and anti-HPA patient sera. RESULTS: Human embryonic kidney 293 cell lines stably expressing either Twin-Strep-labeled GPIa/IIa, GPIIb/IIIa, GPIb/IX, or GPIb/IX/V complexes or GPV as well as the distinct HPA-1, HPA-3, and HPA-5 epitopes were successfully generated. Applying the generated GP-expressing cell lines, the developed RETSUP assay proved very sensitive and specific with recombinant antibodies targeting different GPs and human plasma/serum samples. The results of the test were not affected by the GP carrying the Twin-Strep-tag or by using freshly harvested or cryopreserved cells. CONCLUSION: The RETSUP assay is an easy-to-perform, sensitive, and specific assay for the detection of plasma/serum antibodies to platelet GP, with performance comparable to or better than those of current state-of-the-art assays in antiplatelet antibody diagnostics. Owing to the recombinant nature of the target antigens, it can be easily adapted to detect antibodies in other antibody-mediated diseases.


Assuntos
Antígenos de Plaquetas Humanas , Proteínas de Membrana , Humanos , Isoanticorpos , Plaquetas , Ensaio de Imunoadsorção Enzimática/métodos , Complexo Glicoproteico GPIIb-IIIa de Plaquetas , Antígenos de Plaquetas Humanas/genética
5.
Talanta ; 271: 125697, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38295449

RESUMO

Therapeutic drug monitoring (TDM) is an important tool in precision medicine as it allows estimating pharmacodynamic and pharmacokinetic effects of drugs in clinical settings. An accurate, fast and real-time determination of the drug concentrations in patients ensures fast decision-making processes at the bedside to optimize the clinical treatment. Surface-enhanced Raman spectroscopy (SERS), which is based on the application of metallic nanostructured substrates to amplify the inherent weak Raman signal, is a promising technique in medical research due to its molecular specificity and trace sensitivity accompanied with short detection times. Therefore, we developed a SERS-based detection scheme using silicon nanowires decorated with silver nanoparticles, fabricated by means of top-down etching combined with chemical deposition, to detect the antibiotic ceftriaxone (CRO) in spiked fresh plasma and microdialysis samples. We successfully detected CRO in both matrices with an LOD of 94 µM in protein-depleted fresh plasma and 1.4 µM in microdialysate.


Assuntos
Nanopartículas Metálicas , Nanofios , Humanos , Antibacterianos/farmacologia , Prata/química , Ceftriaxona , Silício/química , Nanopartículas Metálicas/química , Nanofios/química , Análise Espectral Raman/métodos
6.
Ann Surg ; 279(3): 402-409, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37477023

RESUMO

OBJECTIVE: To investigate whether goal-directed albumin substitution during surgery and postanesthesia care to maintain a serum albumin concentration >30 g/L can reduce postoperative complications. BACKGROUND: Hypoalbuminemia is associated with numerous postoperative complications. Since albumin has important physiological functions, substitution of patients with hypoalbuminemia is worth considering. METHODS: We conducted a single-center, randomized, controlled, outcome assessor-blinded clinical trial in adult patients, American Society of Anesthesiologists physical status classification 3 to 4 or undergoing high-risk surgery. Patients, whose serum albumin concentration dropped <30 g/L were randomly assigned to goal-directed albumin substitution maintaining serum concentration >30 g/L or to standard care until discharge from the postanesthesia intermediate care unit. Standard of care allowed albumin substitution in hemodynamic instable patients with serum concentration <20 g/L, only. Primary outcome was the incidence of postoperative complications ≥2 according to the Clavien-Dindo Classification in at least 1 of 9 domains (pulmonary, infectious, cardiovascular, neurological, renal, gastrointestinal, wound, pain, and hematological) until postoperative day 15. RESULTS: Of 2509 included patients, 600 (23.9%) developed serum albumin concentrations <30 g/L. Human albumin 60 g (40-80 g) was substituted to 299 (99.7%) patients in the intervention group and to 54 (18.0%) in the standard care group. At least 1 postoperative complication classified as Clavien-Dindo Classification ≥2 occurred in 254 of 300 patients (84.7%) in the intervention group and in 262 of 300 (87.3%) in the standard treatment group (risk difference -2.7%, 95% CI, -8.3% to 2.9%). CONCLUSION: Maintaining serum albumin concentration of >30 g/L perioperatively cannot generally be recommended in high-risk noncardiac surgery patients.


Assuntos
Hipoalbuminemia , Adulto , Humanos , Hipoalbuminemia/complicações , Objetivos , Padrão de Cuidado , Albumina Sérica/análise , Complicações Pós-Operatórias/epidemiologia
7.
ACS Chem Biol ; 18(7): 1653-1660, 2023 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-37406307

RESUMO

Personalized assessment of vitamin levels in point-of-care (POC) devices is urgently needed to advance the recognition of diseases associated with malnutrition and unbalanced diets. We here introduce a diagnostic platform, which showcases an easy and rapid readout of vitamin B6 (pyridoxal phosphate, PLP) levels in erythrocytes as a first step toward a home-use POC. The technology is based on fluorescent probes, which bind to PLP-dependent enzymes (PLP-DEs) and thereby indirectly report their occupancy with endogenous B6. For example, low vitamin levels result in high probe binding, yielding a strong signal and vice versa. Antibodies against signature human PLP-DEs were immobilized on microarrays to capture probe labeled enzymes for fluorescent detection. Calibrating the system with defined B6 levels revealed a concentration-depended readout as well as sufficient sensitivity for its detection in erythrocytes. To account for individual differences in protein expression, a second antibody was used to normalize protein abundance. This sandwiched assay correctly reported relative B6 levels in human erythrocyte samples, as confirmed by classical laboratory diagnostics. In principle, the platform layout can be easily expanded to other crucial vitamins beyond B6 via an analogous probe strategy.


Assuntos
Fosfato de Piridoxal , Vitamina B 6 , Humanos , Fosfato de Piridoxal/metabolismo , Testes de Diagnóstico Rápido , Piridoxina/metabolismo , Vitaminas , Eritrócitos/metabolismo
8.
J Clin Virol ; 165: 105521, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37302248

RESUMO

BACKGROUND: European legislation defines as "near-patient testing" (NPT) what is popularly and in other legislations specified as "point-of-care testing" (POCT). Systems intended for NPT/POCT use must be characterized by independence from operator activities during the analytic procedure. However, tools for evaluating this are lacking. We hypothesized that the variability of measurement results obtained from identical samples with a larger number of identical devices by different operators, expressed as the method-specific reproducibility of measurement results reported in External Quality Assessment (EQA) schemes, is an indicator for this characteristic. MATERIALS AND METHODS: Legal frameworks in the EU, the USA and Australia were evaluated about their requirements for NPT/POCT. EQA reproducibility of seven SARS-CoV-2-NAAT systems, all but one designated as "POCT", was calculated from variabilities in Ct values obtained from the respective device types in three different EQA schemes for virus genome detection. RESULTS: A matrix for characterizing test systems based on their technical complexity and the required operator competence was derived from requirements of the European In Vitro Diagnostic Regulation (IVDR) 2017/746. Good EQA reproducibility of the measurement results of the test systems investigated implies that different users in different locations have no recognizable influence on their measurement results. CONCLUSION: The fundamental suitability of test systems for NPT/POCT use according to IVDR can be easily verified using the evaluation matrix presented. EQA reproducibility is a specific characteristic indicating independence from operator activities of NPT/POCT assays. EQA reproducibility of other systems than those investigated here remains to be determined.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , Reprodutibilidade dos Testes , COVID-19/diagnóstico , Sistemas Automatizados de Assistência Junto ao Leito , Técnicas de Amplificação de Ácido Nucleico
9.
Clin Chem Lab Med ; 61(7): 1255-1265, 2023 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-36753693

RESUMO

OBJECTIVES: The therapeutic antibody infliximab (IFX) has improved the life quality of numerous autoinflammatory disease patients. However, IFX can trigger the generation of anti-drug antibodies (ADA), whose optimal evaluation and management are currently subject of controversial discussions. We present two novel surface plasmon resonance (SPR) biosensor assays for therapeutic drug monitoring of IFX and characterization of ADA and investigated the diagnostic value of ADA binding properties. METHODS: IFX and ADA were quantified via developed SPR biosensor assays (IFXmon and ADAmon, respectively) and diagnostics-approved ELISA in sera from inflammatory bowel disease patients. Pre-analytic ADA enrichment with magnetic beads enabled analytical drug tolerance of the ADAmon assay. The dissociation ratio (DissR) as an index for ADA:IFX binding stability was calculated from the SPR sensorgrams of ADA quantification runs. RESULTS: IFX levels determined by IFXmon assay and ELISA showed high agreement, whereas ADA quantification concordance between ADAmon assay and ELISA was poor. In patients, DissR was predominantly constant over time and differed significantly between therapy outcomes. A DissR cut-off of 1.524 indicated undetectable IFX levels with 71.4% sensitivity and 88.9% specificity. Additionally, the SPR reference surface was exploited as serum-individual negative control to check result plausibility within multi-sample run sequences. CONCLUSIONS: Overall, both SPR biosensor assays exhibited reliable quantitative performance with accuracies superior to their ELISA counterparts and precision inferior to ELISA only for ADAmon. DissR presented itself as promising ADA binding parameter and could contribute to both earlier and more tailored therapeutic decisions.


Assuntos
Monitoramento de Medicamentos , Ressonância de Plasmônio de Superfície , Humanos , Infliximab , Relevância Clínica , Anticorpos , Ensaio de Imunoadsorção Enzimática
10.
Biomedicines ; 10(10)2022 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-36289665

RESUMO

Programmed death-1 receptor PD-1(CD279) and its corresponding ligands PD-L1(CD274, B7-H1) and PD-L2(CD273, B7-DC) play important roles in physiological immune tolerance and for immune escape in cancer disease. Hence, the establishment and analytical validation of a novel enzyme-linked immunosorbent assay (ELISA) to measure soluble PD-1, PD-L1 and PD-L2 in blood samples according to high quality standards is required. Antibody pairs were used to establish novel highly sensitive ELISAs for all three markers on an open electrochemiluminescence Quickplex platform. Analytical validation comprised intra- and interassay imprecision, limit of quantification, dilution linearity, material comparison and analytical selectivity testing. The methods demonstrated a broad dynamic range and precise measurements down to the pg/mL range. The coefficient of variation (CV) during the intra-assay imprecision measurements with three patient pools did not exceed 10% for all three assays (PD-1: 6.4%, 6.5%, 7.8%, PD-L1: 7.1%, 4.2%, 6.8%; PD-L2: 4.5%, 10.0%, 9.9%). Dilution linearity experiments in both buffer and heparin plasma displayed good linearity. Selectivity was shown for each marker in titration cross-reactivity experiments up to concentrations of at least 15 ng/mL of these, possibly confounding other markers. Soluble PD-1, PD-L1 and PD-L2 can be measured highly sensitively in serum and plasma and can safely be applied to clinical study settings.

11.
Biomedicines ; 10(10)2022 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-36289796

RESUMO

The interaction between programmed death-1 receptor PD-1 and its ligands PD-L1 and PD-L2 is involved in self-tolerance, immune escape of cancer, cardiovascular diseases, and COVID-19. As blood-based protein markers they bear great potential to improve oncoimmunology research and monitoring of anti-cancer immunotherapy. A variety of preanalytical conditions were tested to assure high quality plasma sample measurements: (i) different time intervals and storage temperatures before and after blood centrifugation; (ii) fresh samples and repeated freeze-thaw-cycles; (iii) different conditions of sample preparation before measurement. Concerning short-term stability, acceptable recoveries for PD-1 between 80 and 120% were obtained when samples were kept up to 24 h at 4 and 25 °C before and after blood centrifugation. Similarly, recoveries for PD-L2 were acceptable for 24 h at 4 °C and 6 h at 25 °C before blood centrifugation and up to 24 h at 4 and 25 °C after centrifugation. Variations for PD-L1 were somewhat higher, however, at very low signal levels. Sample concentrations (ng/mL) were neither affected by the freezing process nor by repeated freeze-thaw cycles with coefficients of variation for PD-1: 9.1%, PD-L1 6.8%, and PD-L2 4.8%. All three biomarkers showed good stability regarding preanalytic conditions of sample handling enabling reliable and reproducible quantification in oncoimmunology research and clinical settings of anti-cancer immunotherapy.

12.
Sci Rep ; 12(1): 16419, 2022 09 30.
Artigo em Inglês | MEDLINE | ID: mdl-36180564

RESUMO

Extended cut-off filtration by medium cut-off membranes (MCO) has been shown to be safe in maintenance hemodialysis (HD). The notion of using them for the control of chronic low-grade inflammation and positively influencing cellular immune aberrations seems tempting. We conducted an open label, multicenter, randomized, 90 day 2-phase cross over clinical trial (MCO- vs. high flux-HD). 46 patients underwent randomization of which 34 completed the study. Dialysate- or pre- and post-dialysis serum inflammatory mediators were assayed for each study visit. Ex vivo T cell activation was assessed from cryopreserved leucocytes by flow cytometry. Linear mixed models were used to compare treatment modalities, with difference in pre-dialysis serum MCP-1 levels after 3 months as the predefined primary endpoint. Filtration/dialysate concentrations of most mediators, including MCP-1 (mean ± SD: 10.5 ± 5.9 vs. 5.1 ± 3.8 pg/ml, P < 0.001) were significantly increased during MCO- versus high flux-HD. However, except for the largest mediator studied, i.e., YKL-40, this did not confer any advantages for single session elimination kinetics (post-HD mean ± SD: 360 ± 334 vs. 564 ± 422 pg/ml, P < 0.001). No sustained reduction of any of the studied mediators was found neither. Still, the long-term reduction of CD69+ (P = 0.01) and PD1+ (P = 0.02) activated CD4+ T cells was striking. Thus, MCO-HD does not induce reduction of a broad range of inflammatory mediators studied here. Long-term reduction over a 3-month period was not possible. Increased single session filtration, as evidenced by increased dialysate concentrations of inflammatory mediators during MCO-HD, might eventually be compensated for by compartment redistribution or increased production during dialysis session. Nevertheless, lasting effects on the T-cell phenotype were seen, which deserves further investigation.


Assuntos
Hemodiafiltração , Cefalosporinas , Proteína 1 Semelhante à Quitinase-3 , Estudos Cross-Over , Soluções para Diálise , Humanos , Inflamação , Mediadores da Inflamação , Membranas Artificiais , Fenótipo , Estudos Prospectivos , Diálise Renal
13.
Multidiscip Respir Med ; 17: 825, 2022 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-35646346

RESUMO

The relationship between SARS-CoV-2 quantitative viral load and risk of disease progression, morbidity such as long- COVID or mortality in immunosuppressed, remains largely undefined in COVID-19 patients. Critically ill immunosuppressed patients potentially benefit from remdesivir treatment because of the prolonged course of their infection. Four critically ill immunocompromised patients and the impact of remdesivir on viral dynamics in lower respiratory samples were studied. Bronchoalveolar lavage (BAL) samples were assessed to measure SARS-CoV-2 quantitative viral load using real-time PCR. Corresponding plasma levels of remdesivir and its metabolite GS-441524 were determined. Mean virus load of 39.74 x 107 geq/ml (±33.25 x 107 geq/ml) on day 1 dropped significantly (p<0.008) to 3.54 x 106 geq/ml (±6.93 x 106 geq/ml) on day 3 and to 1.4 x 105 geq/ml (±2.35 x 105 geq/ml) on day 5 of remdesivir treatment. Mean virus load dropped below <1% between day 1 and 5 of remdesivir treatment. Parent prodrug remdesivir and also GS441524 metabolite levels of antiviral activity in our patients were far in excess of EC 50. Our data present that remdesivir treatment potentially reduces the SARS-CoV-2 viral load in immunosuppressed critically ill patients. However, the implication of viral load reduction on morbidity and mortality needs further investigation.

14.
Clin Chem Lab Med ; 60(8): 1186-1201, 2022 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-35607775

RESUMO

OBJECTIVES: Proposal of a risk analysis model to diminish negative impact on patient care by preanalytical errors in blood gas analysis (BGA). METHODS: Here we designed a Failure Mode and Effects Analysis (FMEA) risk assessment template for BGA, based on literature references and expertise of an international team of laboratory and clinical health care professionals. RESULTS: The FMEA identifies pre-analytical process steps, errors that may occur whilst performing BGA (potential failure mode), possible consequences (potential failure effect) and preventive/corrective actions (current controls). Probability of failure occurrence (OCC), severity of failure (SEV) and probability of failure detection (DET) are scored per potential failure mode. OCC and DET depend on test setting and patient population e.g., they differ in primary community health centres as compared to secondary community hospitals and third line university or specialized hospitals. OCC and DET also differ between stand-alone and networked instruments, manual and automated patient identification, and whether results are automatically transmitted to the patient's electronic health record. The risk priority number (RPN = SEV × OCC × DET) can be applied to determine the sequence in which risks are addressed. RPN can be recalculated after implementing changes to decrease OCC and/or increase DET. Key performance indicators are also proposed to evaluate changes. CONCLUSIONS: This FMEA model will help health care professionals manage and minimize the risk of preanalytical errors in BGA.


Assuntos
Análise do Modo e do Efeito de Falhas na Assistência à Saúde , Humanos , Fase Pré-Analítica , Probabilidade , Medição de Risco
16.
Anal Bioanal Chem ; 414(10): 3243-3255, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34936009

RESUMO

The present paper describes a compact point of care (POC) optical device for therapeutic drug monitoring (TDM). The core of the device is a disposable plastic chip where an immunoassay for the determination of immunosuppressants takes place. The chip is designed in order to have ten parallel microchannels allowing the simultaneous detection of more than one analyte with replicate measurements. The device is equipped with a microfluidic system, which provides sample mixing with the necessary chemicals and pumping samples, reagents and buffers into the measurement chip, and with integrated thin film amorphous silicon photodiodes for the fluorescence detection. Submicrometric fluorescent magnetic particles are used as support in the immunoassay in order to improve the efficiency of the assay. In particular, the magnetic feature is used to concentrate the antibody onto the sensing layer leading to a much faster implementation of the assay, while the fluorescent feature is used to increase the optical signal leading to a larger optical dynamic change and consequently a better sensitivity and a lower limit of detection. The design and development of the whole integrated optical device are here illustrated. In addition, detection of mycophenolic acid and cyclosporine A in spiked solutions and in microdialysate samples from patient blood with the implemented device are reported.


Assuntos
Imunossupressores , Dispositivos Ópticos , Humanos , Imunoensaio , Microfluídica , Silício
17.
Transfus Apher Sci ; 60(6): 103278, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34548246

RESUMO

OBJECTIVE: To investigate the effect of convalescent plasma therapy (CPT) on clinical courses of B-cell-sufficient and B-cell-depleted patients with life-threatening COVID-19. PATIENTS AND METHODS: In this case series, we retrospectively analysed clinical, laboratory and cardiopulmonary parameters of six patients with life-threatening COVID-19 receiving convalescent plasma (CP) as rescue therapy between April 11, 2020 to October 10, 2020. Clinical and laboratory parameters before and after transfusion were compared in two B-cell-depleted patients and four B-cell sufficient patients (control group). RESULTS: Both B-cell-depleted patients cleared SARS-CoV-2 virus and survived, while all other patients died within 14 days from intervention despite maximal therapeutic efforts. D-dimer levels increased in both cohorts subsequent to CPT. In control patients, mean Interleukin-6 increased and platelet levels decreased as opposed to decreasing and stable levels in B-cell-depleted patients, respectively. Control patients required increased doses of vasopressor compared to decreasing doses in B-cell depleted patients subsequent to CPT. PO2/FiO2 decrease was more pronounced and respiratory deterioration required postinterventional extracorporeal membrane oxygenation in two control patients. Transpulmonary thermodilution revealed a further increase of the Extravascular Lung Water Index upon CPT in control patients. CONCLUSION: Use of CP in late stages of life-threatening COVID-19 should be used with caution but may be beneficial in B-cell-depleted patients. Further studies are necessary to assess factors predicting potential therapeutic benefits as well as possible hazards.


Assuntos
Linfócitos B , COVID-19/mortalidade , COVID-19/terapia , Depleção Linfocítica , SARS-CoV-2 , Adulto , Idoso , COVID-19/sangue , Intervalo Livre de Doença , Feminino , Humanos , Imunização Passiva , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Taxa de Sobrevida , Soroterapia para COVID-19
18.
Therap Adv Gastroenterol ; 14: 17562848211037849, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34434255

RESUMO

BACKGROUND: Antibodies to infliximab (ATI) in serum are associated with secondary loss of response (LOR) to infliximab (IFX) therapy in patients with inflammatory bowel disease (IBD). However, feasible ATI-related predictors of therapy success are lacking and knowledge about individual ATI dynamics is limited. Therefore, this study analyzed whether ATI dynamics are able to predict LOR to IFX therapy and compared their predictive power with known predictors of LOR to IFX. METHODS: This was a retrospective study of patients with Crohn's disease (CD) or ulcerative colitis (UC) on IFX maintenance therapy and proactive IFX and immunogenicity monitoring in an outpatient clinic in Germany. Slopes of ATI (S ATI) and IFX levels (dynamic parameters) and medians of ATI, IFX, C-reactive protein, and fecal calprotectin (static parameters) were calculated over a defined period of time after ATI emergence. Dynamic and static parameters were analyzed for associations with end points infliximab discontinuation due to secondary LOR and total IFX discontinuation. RESULTS: In all, 500 visits from 38 IBD patients (28 CD, 10 UC) with a median IFX maintenance duration of 68.2 weeks were evaluated. Grouping by S ATI (ATI-N = ATI nondetectable, ATI- ↓ = negative S ATI, ATI- ↑ = positive S ATI) yielded significant differences for outcomes LOR (p = 0.004) and total IFX discontinuation (p = 0.01). Patients in the ATI-↓ group survived significantly longer LOR-free compared with the ATI-↑ group (p = 0.02). Cox regression confirmed S ATI to be a significant risk factor for LOR (p = 0.002). An S ATI cut-off of approximately 2.0 AU mL-1 week-1 was determined to predict LOR with 83.3% sensitivity and 93.8% specificity. CONCLUSION: The ATI slope-based index S ATI is a new feasible diagnostic predictor of LOR in IBD patients. S ATI may facilitate quick therapeutic decisions after ATI emerge.

19.
Clin Chem Lab Med ; 59(5): 935-945, 2021 04 27.
Artigo em Inglês | MEDLINE | ID: mdl-33554521

RESUMO

OBJECTIVES: Therapeutic drug monitoring (TDM) plays a crucial role in personalized medicine. It helps clinicians to tailor drug dosage for optimized therapy through understanding the underlying complex pharmacokinetics and pharmacodynamics. Conventional, non-continuous TDM fails to provide real-time information, which is particularly important for the initial phase of immunosuppressant therapy, e.g., with cyclosporine (CsA) and mycophenolic acid (MPA). METHODS: We analyzed the time course over 8 h of total and free of immunosuppressive drug (CsA and MPA) concentrations measured by liquid chromatography-tandem mass spectrometry (LC-MS/MS) in 16 kidney transplant patients. Besides repeated blood sampling, intravenous microdialysis was used for continuous sampling. Free drug concentrations were determined from ultracentrifuged EDTA-plasma (UC) and compared with the drug concentrations in the respective microdialysate (µD). µDs were additionally analyzed for free CsA using a novel immunosensor chip integrated into a fluorescence detection platform. The potential of microdialysis coupled with an optical immunosensor for the TDM of immunosuppressants was assessed. RESULTS: Using LC-MS/MS, the free concentrations of CsA (fCsA) and MPA (fMPA) were detectable and the time courses of total and free CsA comparable. fCsA and fMPA and area-under-the-curves (AUCs) in µDs correlated well with those determined in UCs (r≥0.79 and r≥0.88, respectively). Moreover, fCsA in µDs measured with the immunosensor correlated clearly with those determined by LC-MS/MS (r=0.82). CONCLUSIONS: The new microdialysis-supported immunosensor allows real-time analysis of immunosuppressants and tailor-made dosing according to the AUC concept. It readily lends itself to future applications as minimally invasive and continuous near-patient TDM.


Assuntos
Técnicas Biossensoriais , Imunossupressores , Cromatografia Líquida , Monitoramento de Medicamentos , Humanos , Imunoensaio , Ácido Micofenólico , Preparações Farmacêuticas , Espectrometria de Massas em Tandem
20.
Platelets ; 32(3): 398-403, 2021 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-32316806

RESUMO

The extent of the involvement of platelets in venous thromboembolisms (VTE) is still not fully understood. Immature platelets are large, RNA-rich, prothrombotic platelets. They are involved in arterial thromboembolisms and are associated with adverse cardiovascular events. Their role in VTE has not been investigated before. The aim of this study was to assess different platelet parameters including immature platelet fraction (IPF), immature platelet count (IPC), absolute platelet count and platelet aggregation (PA) over time in patients with VTE at time of diagnosis, as well as at 3-10 days and at 90-110 days after diagnosis. 50 healthy volunteers similar in age and sex to patients served as controls at diagnosis. IPF was measured by the Sysmex XE-5000 analyzer, PA was assessed using the Multiplate analyzer. Diagnosis of VTE had no relevant effect on IPF and IPC whereas absolute platelet count and PA were significantly decreased compared to controls. In the course of VTE, IPF decreased significantly, whereas IPC, absolute platelet count and PA increased. In conclusion, VTE was associated with relevant changes of the absolute platelet count and PA at diagnosis, as well as changes in IPF and IPC over time reflecting a relevant and measurable platelet consumption in VTEs.


Assuntos
Plaquetas/metabolismo , Contagem de Plaquetas/métodos , Tromboembolia Venosa/sangue , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Agregação Plaquetária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA