1.
Front Mol Biosci ; 11: 1371426, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38572446

RESUMO

Background: During the last decade, Germany has seen an increased prevalence and a redistribution from undetected to diagnosed diabetes mellitus. Due to this substantial epidemiological development, the number of people with documented type 2 diabetes was 8.7 million in 2022. An estimated two million undiagnosed subjects are to be added. Beyond that, the life expectancy of diabetic subjects is increasing due to more responsive health systems in terms of care. Possible reasons include improved screening of at-risk individuals, the introduction of HbA1c for diagnosis in 2010, and the higher use of risk scores. Additionally, quality aspects of the laboratory methodology should be taken into consideration. Methods: Epidemiology and clinical management of diabetes in Germany are presented in the light of publications retrieved by a selective search of the PubMed database. Additionally, the data from German external quality assessment (EQA) surveys for the measurands glucose in plasma and HbA1c in whole blood, reviewed from 2010 until 2022, were evaluated. Above this, data concerning the analytical performance of near-patient glucometer devices, according to the ISO norm 15197:2013, were analyzed. Results: Two laboratory aspects are in good accordance with the observation of an increase in the diabetes mellitus prevalence when retrospectively reviewing the period 2010 to 2022: First, the analytical performance according to the ISO norm 15197:2013 of the glucometer devices widely used by patients with diabetes for the glucose self-testing, has improved during this period. Secondly, concerning the EQA program of INSTAND, the number of participating laboratories raised significantly in Germany. The spreads of variations of the specified results for plasma glucose remained unchanged between 2010 and 2022, whereas for HbA1c a significant decrease of the result scattering could be observed. Conclusion: These retrospectively established findings testify to an excellent analytical quality of laboratory diagnostics for glucose and HbA1c throughout Germany which may be involved in a better diagnosis and therapy of previously undetected diabetes mellitus.

2.
Front Mol Biosci ; 11: 1345356, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38357630

RESUMO

As hormonal disorders are linked to several diseases, the accurate quantitation of steroid hormone levels in serum is crucial in order to provide patients with a reliable diagnosis. Mass spectrometry-based methods are regarded as having the highest level of specificity and sensitivity. However, immunoassays are more commonly used in routine diagnostics to measure steroid levels as they are more cost effective and straightforward to conduct. This study analyzes the external quality assessment results for the measurement of testosterone, progesterone and 17ß-estradiol in serum using immunoassays between early 2020 and May 2022. As reference measurement procedures are available for the three steroid hormones, the manufacturer-specific biases were normalized to the reference measurement values. The manufacturer-specific coefficients of variation were predominantly inconspicuous, below 20% for the three hormones when outliers are disregarded, however there were large differences between the various manufacturer collectives. For some collectives, the median bias to the respective reference measurement value was repeatedly greater than ±35%, which is the acceptance limit defined by the German Medical Association. In the case of testosterone and progesterone determination, some collectives tended to consistently over- or underestimate analyte concentrations compared to the reference measurement value, however, for 17ß-estradiol determination, both positive and negative biases were observed. This insufficient level of accuracy suggests that cross-reactivity continues to be a fundamental challenge when antibody detection is used to quantify steroids with a high structural similarity. Distinct improvements in standardization are required to provide accurate analysis and thus, reliable clinical interpretations. The increased accuracy of the AX immunoassay for testosterone measurement, as observed in the INSTAND EQAs between 2020 and 2022, could be the result of a recalibration of the assay and raises hope for further improvement of standardization of immunoassay-based steroid hormone analyses in the coming years.

3.
Talanta ; 271: 125697, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38295449

RESUMO

Therapeutic drug monitoring (TDM) is an important tool in precision medicine as it allows estimating pharmacodynamic and pharmacokinetic effects of drugs in clinical settings. An accurate, fast and real-time determination of the drug concentrations in patients ensures fast decision-making processes at the bedside to optimize the clinical treatment. Surface-enhanced Raman spectroscopy (SERS), which is based on the application of metallic nanostructured substrates to amplify the inherent weak Raman signal, is a promising technique in medical research due to its molecular specificity and trace sensitivity accompanied with short detection times. Therefore, we developed a SERS-based detection scheme using silicon nanowires decorated with silver nanoparticles, fabricated by means of top-down etching combined with chemical deposition, to detect the antibiotic ceftriaxone (CRO) in spiked fresh plasma and microdialysis samples. We successfully detected CRO in both matrices with an LOD of 94 µM in protein-depleted fresh plasma and 1.4 µM in microdialysate.


Assuntos
Nanopartículas Metálicas , Nanofios , Humanos , Antibacterianos/farmacologia , Prata/química , Ceftriaxona , Silício/química , Nanopartículas Metálicas/química , Nanofios/química , Análise Espectral Raman/métodos
4.
ACS Chem Biol ; 18(7): 1653-1660, 2023 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-37406307

RESUMO

Personalized assessment of vitamin levels in point-of-care (POC) devices is urgently needed to advance the recognition of diseases associated with malnutrition and unbalanced diets. We here introduce a diagnostic platform, which showcases an easy and rapid readout of vitamin B6 (pyridoxal phosphate, PLP) levels in erythrocytes as a first step toward a home-use POC. The technology is based on fluorescent probes, which bind to PLP-dependent enzymes (PLP-DEs) and thereby indirectly report their occupancy with endogenous B6. For example, low vitamin levels result in high probe binding, yielding a strong signal and vice versa. Antibodies against signature human PLP-DEs were immobilized on microarrays to capture probe labeled enzymes for fluorescent detection. Calibrating the system with defined B6 levels revealed a concentration-depended readout as well as sufficient sensitivity for its detection in erythrocytes. To account for individual differences in protein expression, a second antibody was used to normalize protein abundance. This sandwiched assay correctly reported relative B6 levels in human erythrocyte samples, as confirmed by classical laboratory diagnostics. In principle, the platform layout can be easily expanded to other crucial vitamins beyond B6 via an analogous probe strategy.


Assuntos
Fosfato de Piridoxal , Vitamina B 6 , Humanos , Fosfato de Piridoxal/metabolismo , Testes de Diagnóstico Rápido , Piridoxina/metabolismo , Vitaminas , Eritrócitos/metabolismo
5.
J Clin Virol ; 165: 105521, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37302248

RESUMO

BACKGROUND: European legislation defines as "near-patient testing" (NPT) what is popularly and in other legislations specified as "point-of-care testing" (POCT). Systems intended for NPT/POCT use must be characterized by independence from operator activities during the analytic procedure. However, tools for evaluating this are lacking. We hypothesized that the variability of measurement results obtained from identical samples with a larger number of identical devices by different operators, expressed as the method-specific reproducibility of measurement results reported in External Quality Assessment (EQA) schemes, is an indicator for this characteristic. MATERIALS AND METHODS: Legal frameworks in the EU, the USA and Australia were evaluated about their requirements for NPT/POCT. EQA reproducibility of seven SARS-CoV-2-NAAT systems, all but one designated as "POCT", was calculated from variabilities in Ct values obtained from the respective device types in three different EQA schemes for virus genome detection. RESULTS: A matrix for characterizing test systems based on their technical complexity and the required operator competence was derived from requirements of the European In Vitro Diagnostic Regulation (IVDR) 2017/746. Good EQA reproducibility of the measurement results of the test systems investigated implies that different users in different locations have no recognizable influence on their measurement results. CONCLUSION: The fundamental suitability of test systems for NPT/POCT use according to IVDR can be easily verified using the evaluation matrix presented. EQA reproducibility is a specific characteristic indicating independence from operator activities of NPT/POCT assays. EQA reproducibility of other systems than those investigated here remains to be determined.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , Reprodutibilidade dos Testes , COVID-19/diagnóstico , Sistemas Automatizados de Assistência Junto ao Leito , Técnicas de Amplificação de Ácido Nucleico
6.
Clin Chem Lab Med ; 61(7): 1255-1265, 2023 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-36753693

RESUMO

OBJECTIVES: The therapeutic antibody infliximab (IFX) has improved the life quality of numerous autoinflammatory disease patients. However, IFX can trigger the generation of anti-drug antibodies (ADA), whose optimal evaluation and management are currently subject of controversial discussions. We present two novel surface plasmon resonance (SPR) biosensor assays for therapeutic drug monitoring of IFX and characterization of ADA and investigated the diagnostic value of ADA binding properties. METHODS: IFX and ADA were quantified via developed SPR biosensor assays (IFXmon and ADAmon, respectively) and diagnostics-approved ELISA in sera from inflammatory bowel disease patients. Pre-analytic ADA enrichment with magnetic beads enabled analytical drug tolerance of the ADAmon assay. The dissociation ratio (DissR) as an index for ADA:IFX binding stability was calculated from the SPR sensorgrams of ADA quantification runs. RESULTS: IFX levels determined by IFXmon assay and ELISA showed high agreement, whereas ADA quantification concordance between ADAmon assay and ELISA was poor. In patients, DissR was predominantly constant over time and differed significantly between therapy outcomes. A DissR cut-off of 1.524 indicated undetectable IFX levels with 71.4% sensitivity and 88.9% specificity. Additionally, the SPR reference surface was exploited as serum-individual negative control to check result plausibility within multi-sample run sequences. CONCLUSIONS: Overall, both SPR biosensor assays exhibited reliable quantitative performance with accuracies superior to their ELISA counterparts and precision inferior to ELISA only for ADAmon. DissR presented itself as promising ADA binding parameter and could contribute to both earlier and more tailored therapeutic decisions.


Assuntos
Monitoramento de Medicamentos , Ressonância de Plasmônio de Superfície , Humanos , Infliximab , Relevância Clínica , Anticorpos , Ensaio de Imunoadsorção Enzimática
8.
Anal Bioanal Chem ; 414(10): 3243-3255, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34936009

RESUMO

The present paper describes a compact point of care (POC) optical device for therapeutic drug monitoring (TDM). The core of the device is a disposable plastic chip where an immunoassay for the determination of immunosuppressants takes place. The chip is designed in order to have ten parallel microchannels allowing the simultaneous detection of more than one analyte with replicate measurements. The device is equipped with a microfluidic system, which provides sample mixing with the necessary chemicals and pumping samples, reagents and buffers into the measurement chip, and with integrated thin film amorphous silicon photodiodes for the fluorescence detection. Submicrometric fluorescent magnetic particles are used as support in the immunoassay in order to improve the efficiency of the assay. In particular, the magnetic feature is used to concentrate the antibody onto the sensing layer leading to a much faster implementation of the assay, while the fluorescent feature is used to increase the optical signal leading to a larger optical dynamic change and consequently a better sensitivity and a lower limit of detection. The design and development of the whole integrated optical device are here illustrated. In addition, detection of mycophenolic acid and cyclosporine A in spiked solutions and in microdialysate samples from patient blood with the implemented device are reported.


Assuntos
Imunossupressores , Dispositivos Ópticos , Humanos , Imunoensaio , Microfluídica , Silício
9.
Therap Adv Gastroenterol ; 14: 17562848211037849, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34434255

RESUMO

BACKGROUND: Antibodies to infliximab (ATI) in serum are associated with secondary loss of response (LOR) to infliximab (IFX) therapy in patients with inflammatory bowel disease (IBD). However, feasible ATI-related predictors of therapy success are lacking and knowledge about individual ATI dynamics is limited. Therefore, this study analyzed whether ATI dynamics are able to predict LOR to IFX therapy and compared their predictive power with known predictors of LOR to IFX. METHODS: This was a retrospective study of patients with Crohn's disease (CD) or ulcerative colitis (UC) on IFX maintenance therapy and proactive IFX and immunogenicity monitoring in an outpatient clinic in Germany. Slopes of ATI (S ATI) and IFX levels (dynamic parameters) and medians of ATI, IFX, C-reactive protein, and fecal calprotectin (static parameters) were calculated over a defined period of time after ATI emergence. Dynamic and static parameters were analyzed for associations with end points infliximab discontinuation due to secondary LOR and total IFX discontinuation. RESULTS: In all, 500 visits from 38 IBD patients (28 CD, 10 UC) with a median IFX maintenance duration of 68.2 weeks were evaluated. Grouping by S ATI (ATI-N = ATI nondetectable, ATI- ↓ = negative S ATI, ATI- ↑ = positive S ATI) yielded significant differences for outcomes LOR (p = 0.004) and total IFX discontinuation (p = 0.01). Patients in the ATI-↓ group survived significantly longer LOR-free compared with the ATI-↑ group (p = 0.02). Cox regression confirmed S ATI to be a significant risk factor for LOR (p = 0.002). An S ATI cut-off of approximately 2.0 AU mL-1 week-1 was determined to predict LOR with 83.3% sensitivity and 93.8% specificity. CONCLUSION: The ATI slope-based index S ATI is a new feasible diagnostic predictor of LOR in IBD patients. S ATI may facilitate quick therapeutic decisions after ATI emerge.

10.
Clin Chem Lab Med ; 59(5): 935-945, 2021 04 27.
Artigo em Inglês | MEDLINE | ID: mdl-33554521

RESUMO

OBJECTIVES: Therapeutic drug monitoring (TDM) plays a crucial role in personalized medicine. It helps clinicians to tailor drug dosage for optimized therapy through understanding the underlying complex pharmacokinetics and pharmacodynamics. Conventional, non-continuous TDM fails to provide real-time information, which is particularly important for the initial phase of immunosuppressant therapy, e.g., with cyclosporine (CsA) and mycophenolic acid (MPA). METHODS: We analyzed the time course over 8 h of total and free of immunosuppressive drug (CsA and MPA) concentrations measured by liquid chromatography-tandem mass spectrometry (LC-MS/MS) in 16 kidney transplant patients. Besides repeated blood sampling, intravenous microdialysis was used for continuous sampling. Free drug concentrations were determined from ultracentrifuged EDTA-plasma (UC) and compared with the drug concentrations in the respective microdialysate (µD). µDs were additionally analyzed for free CsA using a novel immunosensor chip integrated into a fluorescence detection platform. The potential of microdialysis coupled with an optical immunosensor for the TDM of immunosuppressants was assessed. RESULTS: Using LC-MS/MS, the free concentrations of CsA (fCsA) and MPA (fMPA) were detectable and the time courses of total and free CsA comparable. fCsA and fMPA and area-under-the-curves (AUCs) in µDs correlated well with those determined in UCs (r≥0.79 and r≥0.88, respectively). Moreover, fCsA in µDs measured with the immunosensor correlated clearly with those determined by LC-MS/MS (r=0.82). CONCLUSIONS: The new microdialysis-supported immunosensor allows real-time analysis of immunosuppressants and tailor-made dosing according to the AUC concept. It readily lends itself to future applications as minimally invasive and continuous near-patient TDM.


Assuntos
Técnicas Biossensoriais , Imunossupressores , Cromatografia Líquida , Monitoramento de Medicamentos , Humanos , Imunoensaio , Ácido Micofenólico , Preparações Farmacêuticas , Espectrometria de Massas em Tandem
11.
Platelets ; 32(3): 398-403, 2021 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-32316806

RESUMO

The extent of the involvement of platelets in venous thromboembolisms (VTE) is still not fully understood. Immature platelets are large, RNA-rich, prothrombotic platelets. They are involved in arterial thromboembolisms and are associated with adverse cardiovascular events. Their role in VTE has not been investigated before. The aim of this study was to assess different platelet parameters including immature platelet fraction (IPF), immature platelet count (IPC), absolute platelet count and platelet aggregation (PA) over time in patients with VTE at time of diagnosis, as well as at 3-10 days and at 90-110 days after diagnosis. 50 healthy volunteers similar in age and sex to patients served as controls at diagnosis. IPF was measured by the Sysmex XE-5000 analyzer, PA was assessed using the Multiplate analyzer. Diagnosis of VTE had no relevant effect on IPF and IPC whereas absolute platelet count and PA were significantly decreased compared to controls. In the course of VTE, IPF decreased significantly, whereas IPC, absolute platelet count and PA increased. In conclusion, VTE was associated with relevant changes of the absolute platelet count and PA at diagnosis, as well as changes in IPF and IPC over time reflecting a relevant and measurable platelet consumption in VTEs.


Assuntos
Plaquetas/metabolismo , Contagem de Plaquetas/métodos , Tromboembolia Venosa/sangue , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Agregação Plaquetária
12.
Clin Lab ; 66(1)2020 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-32013370

RESUMO

BACKGROUND: Point-of-care tests (POCT) measure analytes close to the patients and are a complementary supplement to the test menu of medical laboratories. However, the involvement of many different stakeholders makes it challenging to ensure reliable results. METHODS: In a survey, we asked experienced POCT users how they control their total POCT process and what factors they consider essential for success. Results were verified in four in-depth interviews. RESULTS: Overall, 73 German participants from various medical disciplines completed the survey. All but one participant regarded operator training as important but only half of the participants' institutions conducted operator training on a regular basis. Participants often requested e-learning, but face-to-face teaching is still preferred. Twenty-one percent of participants already used e-learning and reported mixed satisfaction. Fifty-five percent of the participants never refer to the quality management manual. Instead, 94% stated that if a POCT error arises a contact person for POCT is always available at their workplace. The majority of participants think that external and, in particular, internal quality controls are important for POCT. Only a few difficulties for performing quality control such as "temporal expenditure" and "lack of information about the importance of internal quality control" were commonly mentioned. For future developments, participants expect evolution and improvements especially with regard to "measurement quality and reliability". The answers of the experts in the in-depth interviews largely corresponded with the participants of the survey. CONCLUSIONS: The importance of operator training is well established and confirmed in this work. How to conduct this training is less certain, but the answers in this survey suggest some form of blended learning with e-learning and practical elements. The discrepancy between the high importance that guidelines and other normative documents place on written information and their low practical usage was striking.


Assuntos
Pessoal de Saúde/educação , Sistemas Automatizados de Assistência Junto ao Leito/normas , Testes Imediatos/normas , Adolescente , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Garantia da Qualidade dos Cuidados de Saúde , Controle de Qualidade , Adulto Jovem
13.
J Appl Lab Med ; 4(3): 391-403, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31659076

RESUMO

BACKGROUND: Dilated cardiomyopathy (DCM) is a common cause of heart failure with high morbidity and mortality rates. The association of anti-ß1 adrenergic receptor (ß1AR) autoantibodies with disease progression was shown by various studies and in vivo animal experiments. The prevalence of these disease-driving autoantibodies was estimated as 25% to 75% in DCM. The removal of autoantibodies or the interruption of their action leads to a prolonged improvement of heart function. However, presence and impact of the autoimmune aspect in DCM patients must be examined for targeted treatment. METHODS: We developed a heterogeneous immunoassay to support the diagnosis of anti-ß1AR autoantibody-induced DCM. The presentation of the native conformational epitope was enabled by reconstitution of human ß1AR into lipid bilayer nanodiscs, which stabilize the incorporated receptor in aqueous solution for measurements with standard immunological techniques. RESULTS: The incorporation of ß1AR into nanodiscs was verified by chromatographic, spectroscopic, and immunological methods. The functionality was shown by interaction assays with appropriate binding partners. Furthermore, ß1AR nanodiscs were applied to immunoassays for the detection of anti-ß1AR in human sera. Surface plasmon resonance spectroscopy and ELISA were developed, optimized, and validated. The optimized ß1AR nanodisc ELISA enabled a simultaneous measurement of 40 samples in duplicate. An interassay variance of 24% and an intraassay variance of 5% were determined. The limit of detection and the limit of quantification were determined as 0.64 ng/mL and 1.26 ng/mL, respectively (related to a monoclonal anti-ß1AR). CONCLUSIONS: Nanodisc technology is suitable as a novel biomimetic membrane system to stabilize and present ß1AR for detection of autoantibodies with immunological methods in DCM patients.


Assuntos
Autoanticorpos/sangue , Autoantígenos , Cardiomiopatia Dilatada/sangue , Cardiomiopatia Dilatada/diagnóstico , Imunoensaio/métodos , Receptores Adrenérgicos beta 1 , Adulto , Autoanticorpos/imunologia , Autoantígenos/imunologia , Cardiomiopatia Dilatada/imunologia , Ensaio de Imunoadsorção Enzimática , Epitopos/imunologia , Feminino , Imunofluorescência , Genes Reporter , Humanos , Masculino , Nanotecnologia , Receptores Adrenérgicos beta 1/imunologia , Sensibilidade e Especificidade
14.
PLoS One ; 14(7): e0220033, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31339913

RESUMO

BACKGROUND: Persistent antiphospholipid antibodies (aPL) constitute the serological hallmark of the antiphospholipid syndrome (APS). Recently, various new assay technologies for the detection of aPL better suited to multiplex reaction environments than ELISAs emerged. We evaluated the diagnostic performance of such a novel line immunoassay (LIA) for the simultaneous detection of 10 different aPL. METHODS: Fifty-three APS patients and 34 healthy controls were investigated for criteria (antibodies against cardiolipin [aCL], ß2-glycoprotein I [aß2-GPI]) and non-criteria aPL (antibodies against phosphatidic acid [aPA], phosphatidyl-choline [aPC], -ethanolamine [aPE], -glycerol [aPG], -inositol [aPI], -serine [aPS], annexin V [aAnnV], prothrombin [aPT]) IgG and IgM by LIA. Criteria aPL were additionally determined with the established Alegria (ALE), AcuStar (ACU), UniCap (UNI), and AESKULISA (AES) systems and non-criteria aPL with the AES system. Diagnostic performance was evaluated with a gold standard for criteria aPL derived from the results of the four established assays via latent class analysis and with the clinical diagnosis as gold standard for non-criteria aPL. RESULTS: Assay performance of the LIA for criteria aPL was comparable to that of ALE, ACU, UNI, and AES. For non-criteria aPL, sensitivities of the LIA for aPA-, aPI-, aPS-IgG and aPA-IgM were significantly higher and for aPC-, aPE-, aAnnV-IgG and aPC- and aPE-IgM significantly lower than AES. Specificities did not differ significantly. CONCLUSIONS: The LIA constitutes a valuable diagnostic tool for aPL profiling. It offers increased sensitivity for the detection of aPL against anionic phospholipids. In contrast, ELISAs exhibit strengths for the sensitive detection of aPL against neutral phospholipids.


Assuntos
Anticorpos Antifosfolipídeos/imunologia , Síndrome Antifosfolipídica/diagnóstico , Testes Sorológicos/métodos , Adulto , Anticorpos Antifosfolipídeos/sangue , Síndrome Antifosfolipídica/sangue , Síndrome Antifosfolipídica/imunologia , Feminino , Humanos , Imunoensaio/métodos , Imunoensaio/normas , Masculino , Pessoa de Meia-Idade , Fosfolipídeos/imunologia , Sensibilidade e Especificidade , Testes Sorológicos/normas
15.
Anal Bioanal Chem ; 411(29): 7623-7635, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31236649

RESUMO

Immunodiagnostic tests performed at the point of care (POC) today usually employ antibodies for biorecognition and are read out either visually or with specialized equipment. Availability of alternative biorecognition elements with promising features as well as smartphone-based approaches for signal readout, however, challenge the described established configuration in terms of analytical performance and practicability. Assessing these developments' clinical relevance and their impact on POC immunodiagnostics is demanding. The first part of this review will therefore give an overview on suitable diagnostic biosensors based on alternative recognition elements (such as nucleic acid-based aptamers or engineered binding proteins) and exemplify advantages and drawbacks of these biomolecules on the base of selected assays. The second part of the review then focuses on smartphone-connected diagnostics and discusses the indispensable considerations required for successful future clinical POCT implementation. Together, the joint depiction of two of the most innovative and exciting developments in the field will enable the reader to cast a glance into the distant future of POC immunodiagnostics.


Assuntos
Testes Imunológicos/métodos , Smartphone , Aptâmeros de Nucleotídeos/química , Técnicas Biossensoriais/instrumentação , Humanos , Testes Imunológicos/normas , Sistemas Automatizados de Assistência Junto ao Leito , Sensibilidade e Especificidade
16.
Anal Bioanal Chem ; 411(29): 7607-7621, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31152226

RESUMO

Immunological methods are widely applied in medical diagnostics for the detection and quantification of a plethora of analytes. Associated analytical challenges usually require these assays to be performed in a central laboratory. During the last several years, however, the clinical demand for rapid immunodiagnostics to be performed in the immediate proximity of the patient has been constantly increasing. Biosensors constitute one of the key technologies enabling the necessary, yet challenging transition of immunodiagnostic tests from the central laboratory to the point of care. This review is intended to provide insights into the current state of this transition process with a focus on the role of biosensor-based systems. To begin with, an overview on standard immunodiagnostic tests presently employed in the central laboratory and at the point of care is given. The review then moves on to demonstrate how biosensor technologies are reshaping this landscape. Single analyte as well as multiplexed immunosensors applicable to point of care scenarios are presented. A section on the areas of clinical application then creates the bridge to day-to-day diagnostic practice. Finally, the depicted developments are critically weighed and future perspectives discussed in order to give the reader a firm idea on the forthcoming trends to be expected in this diagnostic field.


Assuntos
Técnicas Biossensoriais/instrumentação , Testes Imunológicos/métodos , Laboratórios/organização & administração , Sistemas Automatizados de Assistência Junto ao Leito/tendências , Humanos
17.
PLoS Pathog ; 14(5): e1007048, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29718991

RESUMO

The exceptional toxicity of botulinum neurotoxins (BoNTs) is mediated by high avidity binding to complex polysialogangliosides and intraluminal segments of synaptic vesicle proteins embedded in the presynaptic membrane. One peculiarity is an exposed hydrophobic loop in the toxin's cell binding domain HC, which is located between the ganglioside- and protein receptor-binding sites, and that is particularly pronounced in the serotypes BoNT/B, DC, and G sharing synaptotagmin as protein receptor. Here, we provide evidence that this HC loop is a critical component of their tripartite receptor recognition complex. Binding to nanodisc-embedded receptors and toxicity were virtually abolished in BoNT mutants lacking residues at the tip of the HC loop. Surface plasmon resonance experiments revealed that only insertion of the HC loop into the lipid-bilayer compensates for the entropic penalty inflicted by the dual-receptor binding. Our results represent a new paradigm of how BoNT/B, DC, and G employ ternary interactions with a protein, ganglioside, and lipids to mediate their extraordinary neurotoxicity.


Assuntos
Toxinas Botulínicas/genética , Toxinas Botulínicas/metabolismo , Animais , Sítios de Ligação , Toxinas Botulínicas Tipo A/metabolismo , Proteínas de Transporte/metabolismo , Membrana Celular/metabolismo , Cristalografia por Raios X , Gangliosídeos , Interações Hidrofóbicas e Hidrofílicas , Lipídeos , Glicoproteínas de Membrana/metabolismo , Camundongos , Ligação Proteica , Conformação Proteica , Receptores de Neurotransmissores/metabolismo , Sorogrupo , Vesículas Sinápticas
18.
Clin Chem Lab Med ; 56(8): 1238-1250, 2018 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-29708877

RESUMO

BACKGROUND: Determination of blood glucose concentration is one of the most important measurements in clinical chemistry worldwide. Analyzers in central laboratories (CL) and point-of-care tests (POCT) are both frequently used. In Germany, regular participation in external quality assessment (EQA) schemes is mandatory for laboratories performing glucose testing. METHODS: Glucose testing data from the two German EQAs "Reference Institute for Bioanalytics" (RfB) and "INSTAND - Gesellschaft zur Förderung der Qualitätssicherung in medizinischen Laboratorien" (Instand) were analyzed from 2012 to 2016. Multivariable odds ratios (OR) for the probability to reach a "good" result were calculated. Imprecision and bias were determined and clinical risk of measurement errors estimated. RESULTS: The device employed was the most important variable required for a "good" performance in all EQAs. Additional participation in an EQA for CL automated analyzers improved performance in POCT EQAs. The reciprocal effect was less pronounced. New participants performed worse than experienced participants especially in CL EQAs. Imprecision was generally smaller for CL, but some POCT devices reached a comparable performance. Large lot-to-lot differences occurred in over 10% of analyzed cases. We propose the "bias budget" as a new metric to express the maximum allowable bias that still carries acceptable medical risk. Bias budgets were smallest and clinical risks of errors greatest in the low range of measurement 60-115 mg/dL (3.3-6.4 mmol/L) for most devices. CONCLUSIONS: EQAs help to maintain high analytical performances. They generate important data that serve as the foundation for learning and improvement in the laboratory healthcare system.


Assuntos
Análise Química do Sangue/normas , Glicemia/análise , Controle de Qualidade , Viés , Análise Química do Sangue/instrumentação , Alemanha , Humanos , Testes Imediatos/normas
19.
J Chromatogr A ; 1547: 45-52, 2018 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-29544893

RESUMO

Therapeutic drug monitoring (TDM) of the immunosuppressive drug tacrolimus is essential to avoid side effects and rejection of the allograft after transplantation. In the blood circulation, tacrolimus is largely located inside erythrocytes or bound to plasma proteins and less than 0.1% is protein-unbound (free). One basic principle of clinical pharmacology is that only free drug is pharmacologically active and monitoring this portion has the potential to better reflect the drug effect than conventional measurements of total tacrolimus in whole blood. To address this, a highly sensitive and straightforward on-line liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed, validated and applied to patient plasma samples. The sample preparation included ultracentrifugation and addition of the stable isotope labeled drug analogue D2,13C-tacrolimus, followed by on-line sample extraction and measurement using a Sciex QTRAP® 6500 in the multiple reaction monitoring mode. Due to very low concentrations of protein-unbound tacrolimus, it was important to develop a highly sensitive, precise and accurate assay. Here, we first report the efficient formation of tacrolimus lithium adduct ions, which greatly increased assay sensitivity. A lower limit of quantification (LLOQ) of 1 pg/mL (10 fg on column) was achieved and the assay was linear between 1 and 200 pg/mL. There was no carry-over detected. The inaccuracy ranged from -9.8 to 7.4% and the greatest imprecision was 7.5%. The matrix factor was found to be smaller than 1.1%. In summary, this method represents a suitable tool to investigate the potential clinical value of free tacrolimus monitoring in organ transplant recipients.


Assuntos
Cromatografia Líquida/métodos , Tacrolimo/sangue , Espectrometria de Massas em Tandem/métodos , Humanos , Imunossupressores/sangue , Íons , Ligação Proteica , Controle de Qualidade , Reprodutibilidade dos Testes , Espectrometria de Massas por Ionização por Electrospray , Ultrafiltração
20.
Kidney Int ; 93(1): 221-230, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28941940

RESUMO

Chronic inflammation contributes to increased mortality in hemodialysis (HD) patients. YKL-40 is a novel marker of inflammation, tissue remodeling, and highly expressed in macrophages inside vascular lesions. Elevated levels of YKL-40 have been reported for HD patients but how it integrates into the proinflammatory mediator network as a predictor of mortality remains elusive. We studied serum YKL-40, Interleukin-6 (IL-6), high-sensitivity C-reactive protein, monocyte chemotactic protein-1 (MCP-1), and interferon-gamma induced protein-10 (IP-10) in 475 chronic hemodialysis patients. Patients were followed for mortality for a median of 37 [interquartile range: 25-49] months and checked for interrelation of the measured mediators. To plot cumulative incidence functions, patients were stratified into terciles per YKL-40, IL-6, MCP-1, and IP-10 levels. Multivariable Cox regression models were built to examine associations of YKL-40, IP-10, and MCP-1 with all-cause and cause-specific mortality. Net reclassification improvement was calculated for the final models containing YKL-40 and IL-6. Increased YKL-40 was independently associated with age, IP-10, and IL-6 serum levels. After adjustment for demographic and laboratory parameters, comorbidities, and IL-6, only YKL-40 significantly improved risk prediction for all-cause (hazard ratio 1.4; 95% confidence interval 1.1-1.8) and cardiovascular mortality (hazard ratio 1.5; 95% confidence interval 1.03-2.2). Thus, in contrast to other biomarkers of aberrant macrophage activation, YKL-40 reflects inflammatory activity, which is not covered by IL-6. Mechanistic and prospective studies are needed to test for causal involvement of YKL-40 and whether it might qualify as a therapeutic target.


Assuntos
Proteína 1 Semelhante à Quitinase-3/sangue , Mediadores da Inflamação/sangue , Falência Renal Crônica/mortalidade , Falência Renal Crônica/terapia , Diálise Renal/mortalidade , Idoso , Biomarcadores/sangue , Estudos Transversais , Feminino , Humanos , Falência Renal Crônica/sangue , Falência Renal Crônica/diagnóstico , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Diálise Renal/efeitos adversos , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS