Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Appl Radiat Isot ; 195: 110733, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36841012

RESUMO

The L6 chondritic meteorite, HaH-346, fell in Libya. However, neither the exact date of the fall nor the exact size of the original meteoroid or asteroid is known. A specimen of the meteorite, weighing 488 g, was measured using ultra low-background gamma-ray spectrometry in the 225 m deep underground facility HADES. Activation products 22Na, 26Al, 60Co, 57Co, 54Mn and 44Ti were detected. The detection efficiency was determined by 3D scanning the meteorite and introducing this in the computer model of the detector and sample implemented in the MCNP6.2 Monte Carlo code. The activities of 22Na and 26Al support the hypothesis that the fall took place on 26 August 2018. Furthermore, the 60Co and 26Al activities indicate that the original radius of meteoroid was between 50 and 80 cm, which suggests the mass prior to atmospheric entry was between 2400 and 7300 kg.

2.
Phys Rev Lett ; 124(18): 181802, 2020 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-32441984

RESUMO

Weak-scale dark matter particles, in collisions with nuclei, can mediate transitions between different nuclear energy levels. In particular, owing to sizeable momentum exchange, dark matter particles can enable de-excitation of nuclear isomers that are extremely long lived with respect to regular radioactive decays. In this Letter, we utilize data from a past experiment with ^{180}Ta^{m} to search for γ lines that would accompany dark matter induced de-excitation of this isomer. Nonobservation of such transitions above background yields the first direct constraint on the lifetime of ^{180}Ta^{m} against dark matter initiated transitions: T_{1/2}>1.3×10^{14} a at 90% credibility. Using this result, we derive novel constraints on dark matter models with strongly interacting relics and on models with inelastic dark matter particles. Existing constraints are strengthened by this independent new method. The obtained limits are also valid for the standard model γ-decay of ^{180}Ta^{m}.

3.
Appl Radiat Isot ; 153: 108831, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31382086

RESUMO

The radium isotopes 226Ra and 228Ra can provide important data on the dynamics of deep-sea hydrothermal plumes that travel the oceans for decades and have great impact on the ocean chemistry. This study focuses on parameters important for obtaining low detection limits for 228Ra using gamma-ray spectrometry. It is present at mBq-levels in samples collected during the US GEOTRACES 2013 cruise to the Southeast Pacific Ocean.

4.
Appl Radiat Isot ; 147: 182-188, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30878781

RESUMO

A collimated source of 241Am was scanned over the endcap of a 21 year old coaxial HPGe-detector that had spent about 75% of its life at room temperature (and the remaining time at 77 K). The detector response was recorded and used as a measure of the relative thickness of the top deadlayer. This thickness was not homogeneous and was thicker near to the outer surface of the crystal compared to the centre, which could be a result of increased diffusion of Li atoms during times the detector was kept at room temperature. The results were compared with two newer HPGe-detectors that proved to have homogeneous top deadlayers.

5.
Appl Radiat Isot ; 134: 446-449, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28838725

RESUMO

Since a few years there are well-type HPGe-detectors with a small, point-like, anode contacts available commercially. This paper describes the characterisation of the first ultra low-background, so-called, SAGe™ well detector with regards to resolution and background performance. Inside a passive lead/copper shield in the underground laboratory HADES a background count rate of 690 ± 6d-1 (268 ± 3d-1 per kg Ge) was recorded 19 months after taking it underground.

6.
Appl Radiat Isot ; 126: 273-278, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28314506

RESUMO

The results of the three years European Metrology Research Programme's (EMRP) joint research project 'Metrology for processing materials with high natural radioactivity' (MetroNORM) are presented. In this project, metrologically sound novel instruments and procedures for laboratory and in-situ NORM activity measurements have been developed. Additionally, standard reference materials and sources for traceable calibration and improved decay data of natural radionuclides have been established.

7.
J Environ Radioact ; 172: 63-73, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28324687

RESUMO

The European Basic Safety Standards (EU-BSS) describes a set of NORM (Naturally Occurring Radioactive Material)-processing industries which produce residues known to be possibly enriched in NORs (Naturally Occurring Radionuclides). These residues can be used as a component in building materials aimed for public usage. The industrial processes, in which the residues are produced, are often complex and total monitoring can be challenging especially when the origin of the used raw materials varies. In this study the NORs present in non-ferrous fayalite slags of a secondary smelter facility, a NORM-processing industry according to the EU-BSS, were monitored daily during a one-month production period. In addition flue dust samples and feedstock samples, known to contain elevated levels of NORs, of the same period were measured. The survey involved the gamma-ray spectrometric analysis of the decay products from the 238U and 232Th decay chains, 235U and 40K using HPGe detectors. Secular equilibrium was observed for the slags, flue dust and feedstock samples in the 232Th decay chain, in contrast to the 238U decay chain. During the month in question the ratios of maximum over minimum activity concentration were 3.1 ± 0.5 for 40K, 4 ± 1 for 238U, 6 ± 1 for 226Ra, 13 ± 7 for 210Pb, 4.5 ± 0.6 for 228Ra and 4.7 ± 0.7 for 228Th for the slags. Even with the activity concentration of the feedstock material ranging up to 2.1 ± 0.3 kBq/kg for 238U, 1.6 ± 0.2 kBq for 226Ra, 22 ± 7 kBq/kg for 210Pb, 2.1 ± 0.2 kBq/kg for 228Ra and 2.0 ± 0.4 kBq/kg for 228Th, none of the slag samples exceeded the exemption/clearance levels of the EU-BSS and RP-122 part II, which can respectively provide guidance under equilibrium and in absence of equilibrium. As each NORM-processing industry has its own complexity and variability, the observed variations point out that one should approach one-time measurements or low frequency monitoring methods cautiously. Low frequency measurements should be optimised depending on the discharge of the batches. A follow up of the industrial process and its output can provide important insights to assure a limited public exposure upon application of these industrial residues. Finally a comparison is made with reported data on other metallurgical slags and the use of the slags in building materials is evaluated using the Activity Concentration Index (ACI) proposed by the EU-BSS.


Assuntos
Radiação de Fundo , Monitoramento de Radiação , Poluentes Radioativos/análise , Materiais de Construção
8.
Appl Radiat Isot ; 126: 121-126, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28089270

RESUMO

Forty-eight samples made of CaF2, LiF and YVO4 were placed inside the KSTAR Tokamak and irradiated by neutrons and charged particles from eight plasma pulses. The aim was to provide information for plasma diagnostics. Due to the short pulse durations, the activities induced in the samples were low and therefore measurements were performed in five low-background underground laboratories. Details of the underground measurements, together with data on the quality control amongst the radiometric laboratories, are presented.

9.
J Environ Radioact ; 168: 21-29, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27554708

RESUMO

Bauxite residue, also known as red mud, can be used as an aggregate in concrete products. The study involves the radiological characterization of different types of concretes containing bauxite residue from Ukraine. The activity concentrations of radionuclides from the 238U, 232Th decay series and 40K were determined for concrete mixture samples incorporating 30, 40, 50, 60, 75, 85 and 90% (by mass) of bauxite residue using gamma-ray spectrometry with a HPGe detector. The studied bauxite residue can, from a radiological point of view using activity concentration indexes developed by Markkanen, be used in concrete for building materials and in road construction, even in percentages reaching 90% (by mass). However, when also occupational exposure is considered it is recommended to incorporate less than 75% (by mass) of Ukrainian bauxite residue during the construction of buildings in order to keep the dose to workers below the dose criterion used by Radiation Protection (RP) 122 (0.3 mSv/a). Considering RP122 for evaluation of the total effective dose to workers no restrictions are required for the use of the Ukrainian bauxite residue in road construction.


Assuntos
Óxido de Alumínio/análise , Materiais de Construção/análise , Exposição Ocupacional , Radioisótopos de Potássio/análise , Exposição à Radiação , Tório/análise , Urânio/análise , Álcalis/química , Óxido de Alumínio/química , Mineração , Monitoramento de Radiação , Espectrometria gama , Ucrânia
10.
Appl Radiat Isot ; 109: 96-100, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26597655

RESUMO

A Europallet-sized calibration standard composed of 12 grey cast iron tubes contaminated with (60)Co and (110m)Ag with a mass of 246kg was developed. As the tubes were produced through centrifugal casting it was of particular concern to study the distribution of radionuclides in the radial direction of the tubes. This was done by removing 72 small samples (swarf) of ~0.3g each on both the inside and outside of the tubes. All of the samples were measured in the underground laboratory HADES.

11.
Appl Radiat Isot ; 87: 112-7, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24360858

RESUMO

The half-life of (176)Lu was determined by measuring the (176)Lu activity in metallic lutetium foils. Three different HPGe-detectors located 225 m underground were employed for the study. Measurements using the sum-peak method were performed and resulted in an average massic activity of (52.61±0.36) Bq g(-1). The foils were of natural isotopic abundance so using the massic activity and the value of the natural isotopic abundance of (2.59±0.01)%, a half-life of (3.722±0.029)×10(10)a could be calculated.

12.
Appl Radiat Isot ; 81: 81-6, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23743483

RESUMO

The newest development in IRMM's underground analytical facility is a large lead shield lined with copper that is versatile and can host several detectors of different types. The characteristics and the background performance of the shield are described for four different detector configurations involving HPGe-detectors and NaI-detectors. The shield has been designed to swap detectors, while still maintaining a low background. This enables testing of detectors for other experiments and optimisation of detection limits for specific radionuclides in different projects.


Assuntos
Proteção Radiológica/instrumentação , Radioisótopos/análise , Radiometria/instrumentação , Espectrometria gama/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
13.
Appl Radiat Isot ; 81: 103-8, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23602708

RESUMO

In underground HPGe-detector systems where the cosmic ray induced background is low, it is often difficult to assess the location of background sources. In this study, background counting rates of different HPGe-detectors in different lead shields are reported with the aim of better understanding background sources. To further enhance the understanding of the variations of environmental parameters, the background as a function of time over a long period was also studied.


Assuntos
Radiação de Fundo , Germânio/efeitos da radiação , Chumbo/efeitos da radiação , Proteção Radiológica/instrumentação , Espectrometria gama/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA