Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Bone Miner Metab ; 42(1): 17-26, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38062272

RESUMO

INTRODUCTION: The bone tissue is susceptible to hypergravity (+ G) environment. It is necessary to discuss the extent to which specific + G values are beneficial or detrimental to bone tissue. The objective of this study was to characterize the effects of high + G values on mechanical properties, microstructures, and cellular metabolism of bone. MATERIALS AND METHODS: 30 male Wistar rats aged 12 weeks were randomly divided into 5 groups, and bore different + G (namely + 1G, + 4G, + 8G, + 10G and + 12G) environments respectively for 4 weeks, 5 days each week, and 3 minutes each day. The macro-mechanical parameters, microstructure parameters, and mRNA transcription levels of the tibia were determined through the three-point bending method, micro-CT detection, and q-PCR analysis, respectively. RESULTS: As the + G value increases, hypergravity becomes increasingly detrimental to the macro-mechanical performance of rat tibia. Concerning the microstructure of cancellous bone, there appears to be a favorable trend at + 4G, followed by a progressively detrimental trend at higher G values. In addition, the mRNA transcription levels of OPG and RANKL show an initial tendency of enhanced bone absorption at +4G, followed by an increase in bone remodeling capacity as G value increases. CONCLUSION: The higher G values correspond to poorer macro-mechanical properties of the tibia, and a + 4G environment benefits the microstructure of the tibia. At the cellular level, bone resorption is enhanced in the + 4G group, but the bone remodeling capability gradually increases with further increments in G values.


Assuntos
Hipergravidade , Tíbia , Ratos , Masculino , Animais , Ratos Wistar , Remodelação Óssea , RNA Mensageiro/genética , RNA Mensageiro/metabolismo , Densidade Óssea
2.
J Orthop Surg Res ; 15(1): 40, 2020 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-32028970

RESUMO

BACKGROUND: Additively manufactured porous metallic structures have recently received great attention for bone implant applications. The morphological characteristics and mechanical behavior of 3D printed titanium alloy trabecular structure will affect the effects of artificial prosthesis replacement. However, the mechanical behavior of titanium alloy trabecular structure at present clinical usage still is lack of in-depth study from design to manufacture as well as from structure to mechanical function. METHODS: A unit cell of titanium alloy was designed to mimick trabecular structure. The controlled microarchitecture refers to a repeating array of unit-cells, composed of titanium alloy, which make up the scaffold structure. Five kinds of unit cell mimicking trabecular structure with different pore sizes and porosity were obtained by modifying the strut sizes of the cell and scaling the cell as a whole. The titanium alloy trabecular structure was fabricated by 3D printing based on Electron Beam Melting (EBM). The paper characterized the difference between the designs and fabrication of trabecular structures, as well as mechanical properties and the progressive collapse behavior and failure mechanism of the scaffold. RESULTS: The actual porosities of the EBM-produced bone trabeculae are lower than the designed, and the load capacity of a bearing is related to the porosity of the structure. The larger the porosity of the structure, the smaller the stiffness and the worse the load capacity is. The fracture interface of the trabecular structure under compression is at an angle of 45o with respect to the compressive axis direction, which conforms to Tresca yield criterion. The trabeculae-mimicked unit cell is anisotropy. Under quasi-static loading, loading speed has no effect on mechanical performance of bone trabecular specimens. There is no difference of the mechanical performance at various orientations and sites in metallic workspace. The elastic modulus of the scaffold decreases by 96%-93% and strength reduction 96%-91%, compared with titanium alloy dense metals structure. The apparent elastic modulus of the unit-cell-repeated scaffold is 0.39-0.618 GPa, which is close to that of natural bone and stress shielding can be reduced. CONCLUSION: We have systematically studied the structural design, fabrication and mechanical behavior of a 3D printed titanium alloy scaffold mimicking trabecula bone. This study will be benefit of the application of prostheses with proper structures and functions.


Assuntos
Ligas/química , Substitutos Ósseos/química , Osso Esponjoso/fisiologia , Teste de Materiais/métodos , Alicerces Teciduais/química , Titânio/química , Ligas/normas , Substitutos Ósseos/normas , Osso Esponjoso/anatomia & histologia , Força Compressiva/fisiologia , Teste de Materiais/normas , Impressão Tridimensional/normas , Estresse Mecânico , Alicerces Teciduais/normas , Titânio/normas
3.
Mater Sci Eng C Mater Biol Appl ; 94: 988-997, 2019 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-30423787

RESUMO

Since the accumulations of ratcheting strain combined with creep deformation, which are produced in normal activities, can accelerate the fatigue damage of cartilage in joint, the creep-ratcheting and creep-recovery-ratcheting behaviors of articular cartilage are experimentally investigated under creep-fatigue loads. The effect of pre-creep on ratcheting behavior of cartilage was probed firstly and it is found that the initial ratcheting strain of cartilage presents the larger value (30% and 35%) due to its pre-creep deformation in spite of the short pre-creep time applied. With the increasing pre-creep time the ratcheting strain of sample increases while the ratcheting strain rate decreases. The effects of pre-creep and recovery on ratcheting behavior of cartilage were also investigated and it is noted that the strain of cartilage increases fast at first, decreases partly and then changes periodically with cyclic stress. The ratcheting strain evolutions of different layers are not coincident for cartilage sample after the pre-creep or pre-creep-recovery and the ratcheting strains of different layers with pre-creep are larger than them with pre-creep-recovery. Finally the creep-ratcheting strain of cartilage with different peak-holding time during cyclic compression was studied and it is found that the creep-ratcheting strain with peak-holding time is significantly greater than that without peak-holding time. The creep-ratcheting strain increases with increase of peak-holding time or stress amplitude, while it reduces with rising of stress rate. The creep-ratcheting behavior of cartilage is dependent on its depth. These findings point out that the accumulated deformations, including creep deformation and ratcheting deformation, can accelerate the cartilage's damage.


Assuntos
Cartilagem Articular/patologia , Força Compressiva , Estresse Mecânico , Animais , Sus scrofa , Fatores de Tempo
4.
Biomed Eng Online ; 9: 32, 2010 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-20598128

RESUMO

BACKGROUND: Bone has the ability to adapt to mechanical usage or other biophysical stimuli in terms of its mass and architecture, indicating that a certain mechanism exists for monitoring mechanical usage and controlling the bone's adaptation behaviors. There are four zones describing different bone adaptation behaviors: the disuse, adaptation, overload, and pathologic overload zones. In different zones, the changes of bone mass, as calculated by the difference between the amount of bone formed and what is resorbed, should be different. METHODS: An adaptation model for the trabecular bone at different mechanical levels was presented in this study based on a number of experimental observations and numerical algorithms in the literature. In the proposed model, the amount of bone formation and the probability of bone remodeling activation were proposed in accordance with the mechanical levels. Seven numerical simulation cases under different mechanical conditions were analyzed as examples by incorporating the adaptation model presented in this paper with the finite element method. RESULTS: The proposed bone adaptation model describes the well-known bone adaptation behaviors in different zones. The bone mass and architecture of the bone tissue within the adaptation zone almost remained unchanged. Although the probability of osteoclastic activation is enhanced in the overload zone, the potential of osteoblasts to form bones compensate for the osteoclastic resorption, eventually strengthening the bones. In the disuse zone, the disuse-mode remodeling removes bone tissue in disuse zone. CONCLUSIONS: The study seeks to provide better understanding of the relationships between bone morphology and the mechanical, as well as biological environments. Furthermore, this paper provides a computational model and methodology for the numerical simulation of changes of bone structural morphology that are caused by changes of mechanical and biological environments.


Assuntos
Adaptação Fisiológica , Osso e Ossos/fisiologia , Modelos Biológicos , Algoritmos , Fenômenos Biomecânicos , Densidade Óssea , Reabsorção Óssea , Osso e Ossos/citologia , Feminino , Humanos , Menopausa/fisiologia , Osteoblastos/citologia , Osteogênese , Estresse Mecânico , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA