Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38407982

RESUMO

PURPOSE: To evaluate the ESCRS online calculator for intraocular lens (IOL) calculation in children undergoing lens extraction and primary IOL implantation. SETTING: Department of Ophthalmology, Goethe University Frankfurt, Germany. DESIGN: Retrospective, consecutive case series. METHODS: We included eyes that received phacoemulsification and IOL implantation (Acrysof SN60AT, Alcon, Fort Worth, Tx, USA) due to congenital or juvenile cataract. We compared the mean prediction error (MPE), mean and median absolute prediction error (MAE, MedAE) of formulas provided by the recently introduced online calculator provided by the European Society of Cataract and Refractive Surgeons (ESCRS) to the SRK/T formula, as well as the number of eyes within ±0.5, ±1.0, ±2.0 diopters (D) of target refraction. Postoperative spherical equivalent was measured by retinoscopy 4 to 12 weeks after surgery. RESULTS: Sixty eyes from forty-seven patients with a mean age of 6.5 years ± 3.2 met the inclusion criteria. Mean axial length was 22.27mm ± 1.19. Mean preoperative spherical equivalent (SE) was -0.25 D ± 3.78 and mean postoperative SE was 0.69 D ± 1.53. The MedAE was lowest in the SRK/T formula (0.56 D, ± 1.03) performed significantly better (p = 0.037) than Hoffer QST and Kane, followed by BUII (0.64D, ± 0.92), Pearl DGS (0.65D, ± 0.94), EVO (0.69D, ± 0.94), Hoffer QST (0.75D, ± 0.99), and Kane (0.78D, ± 0.99). All of those were significantly above zero (p < 0.001). Forty-one eyes received an intraoperative optic capture (68%). When excluding eyes that did not receive intraoperative optic capture (n=19; 32%) the MedAE was shown to be lower. CONCLUSION: Using modern IOL calculation formulas provided by the ESCRS calculator provides good refractive predictability and compares for most of the formulas to the results with SRK/T. Additionally the formulas seem to anticipate the postoperative refraction better for eyes that receive a posterior optic capture.

2.
J Refract Surg ; 40(1): e1-e9, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38190559

RESUMO

PURPOSE: To determine the visual outcomes and safety 12 months after implantation of the Presbia Flexivue Microlens refractive corneal inlay. METHODS: In this prospective, non-randomized trial, 22 patients with a mean age of 52.54 ± 2.86 years were implanted with the Flexivue Microlens refractive corneal inlay in the non-dominant eye at the Department of Ophthalmology, Goethe University, Frankfurt, Germany. Corrected near, intermediate, and distance (CNVA, CIVA, and CDVA) visual acuity and uncorrected near, intermediate, and distance (UNVA, UIVA, and UDVA) visual acuity, manifest refraction, subjective quality of vision, endothelial cell count, and contrast sensitivity were measured 1 day, 1 week, and 1, 3, 6, and 12 months postoperatively. RESULTS: For binocular CDVA, no patient lost two or more lines and 30% lost only one line at the 12-month visit. In the eye that had surgery, 85% of the patients lost two or more lines of UDVA, which was statistically significant. Sixty-five percent of the patients gained one or more lines in binocular UIVA, and 80% achieved 20/40 or better in DCIVA. UNVA showed a statistically significant improvement, with 90% of the patients achieving 20/40 or better 12 months after implantation. A total of 85% gained two or more lines in binocular UNVA. CONCLUSIONS: This refractive corneal inlay showed an improvement in binocular UNVA, UIVA, CNVA, and CIVA, whereas binocular CDVA and UDVA were not statistically affected. [J Refract Surg. 2024;40(1):e1-e9.].


Assuntos
Presbiopia , Humanos , Pessoa de Meia-Idade , Presbiopia/cirurgia , Estudos Prospectivos , Refração Ocular , Testes Visuais , Acuidade Visual
3.
Int Ophthalmol ; 43(12): 4933-4943, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37936000

RESUMO

PURPOSE: To evaluate intermediate and long-term visual outcomes and safety of a phakic intraocular posterior chamber lens with a central hole (ICL V4c) for myopic eyes. METHODS: Retrospective, consecutive case study of patients that uneventfully received a ICL V4c for myopia correction, with a 5-year postoperative follow-up. Department of Ophthalmology, Goethe University Frankfurt, Germany. RESULTS: From 241 eyes that underwent ICL implantation, we included 45 eyes with a mean age at surgery of 33 years ± 6 (18-48 years), with a 5 years follow-up. CDVA improved from 0.05logMAR ± 0.15 CDVA preoperatively to - 0.00 ± 0,07 at 5 years and did not change significantly from 3 to 5 years' time (p = 0.266). The mean spherical equivalent (SE) improved from -10.13D ± 3.39 to - 0.45D ± 0.69. The change in endothelial cell count showed a mean decrease of 1.9% per year throughout the follow-up. Safety and efficacy index were 1.16 and 0.78, respectively. Cataract formation was seen in 2 of 241 eyes (0.8%), but in none of the 45 eyes that finished the 5-year follow-up. CONCLUSIONS: Our data show a good intermediate and long-term stability, efficiency, and safety of ICL V4c phakic lenses in myopic eyes comparable to other known literature.


Assuntos
Miopia , Lentes Intraoculares Fácicas , Humanos , Adulto , Seguimentos , Estudos Retrospectivos , Miopia/cirurgia , Implante de Lente Intraocular , Refração Ocular
4.
Br J Ophthalmol ; 2023 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-37845000

RESUMO

PURPOSE: Evaluate whether the axial length of the fellow eye can be used to calculate the intraocular lens (IOL) in eyes with retinal detachment. DESIGN: Retrospective, consecutive case series. METHODS: Our study was conducted at the Goethe University and included patients who underwent silicone oil (SO) removal combined with phacoemulsification and IOL implantation. Preoperative examinations included biometry (IOLMaster 700, Carl Zeiss). We measured axial length (AL) of operated eye (OE) or fellow eye (FE) and compared mean prediction error and mean and median absolute prediction error (MedAE) using four formulas and AL of the OE (Barrett Universal II (BUII)-OE). Additionally, we compared the number of eyes within ±0.50, ±1.00 and ±2.00 dioptre (D) from target refraction. RESULTS: In total, 77 eyes of 77 patients met our inclusion criteria. MedAE was lowest for the BUII-OE (0.42 D) compared with Kane-FE (1.08 D), BUII-FE (1.02 D) and Radial Basis Function 3.0 (RBF3.0)-FE (1.03 D). This was highly significant (p<0.001). The same accounts for the number of eyes within ±0.50 D of the target refraction with the BUII-OE (44 eyes, 57%) outperforming the RBF3.0-FE (20 eyes, 25.9%), Kane-FE and BUII-FE formula (21 eyes, 27.2%) each. CONCLUSION: Our results show a statistically and clinically highly relevant reduction of IOL power predictability when using the AL of the FE for IOL calculation. Using the AL of the SO filled eye after initial vitrectomy results in significantly better postoperative refractive results. A two-step procedure using the AL of the OE after reattachment of the retina is highly recommended.

5.
J Cataract Refract Surg ; 49(12): 1209-1215, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37635306

RESUMO

PURPOSE: To evaluate a recently introduced ESCRS online calculator for intraocular lens (IOL) calculation of a multifocal IOL in refractive lens exchange and cataract surgery in a prospective setting. SETTING: Department of Ophthalmology, Goethe University Frankfurt, Germany. DESIGN: Prospective, consecutive case series. METHODS: Eyes that received lens extraction and multifocal IOL implantation were included. The mean prediction error, mean absolute error, and median absolute prediction error (MedAE) provided by the ESCRS online calculator were compared, as were the number of eyes within ±0.5 diopters (D), ±1.0 D, ±2.0 D of target refraction. The SRK/T formula was also included for comparison. Postoperative spherical equivalent was measured at 3 months. 1 eye per patient was included. RESULTS: 88 eyes from 88 patients with a mean age of 62 ± 9.5 years were included. The MedAE was low for all formulas and ranged from 0.26 D (Kane), Hill-RBF (0.27 D), Hoffer Q Savini/Taroni (Hoffer QST) (0.27 D), Barrett Universal II (BUII) (0.28 D), Emmetropia Verifying Optical (EVO) (0.29 D), Cooke K6 (0.27 D), 0.30 D (Postoperative spherical Equivalent prediction using Artificial intelligence and Linear algorithms, by Debellemaniére, Gatinel, and Saad [Pearl DGS]) to 0.31 D (SRK/T). No statistically significant difference was found ( P = .627). Considering the number of eyes within ±0.5 D of the calculated refraction the best performing was again the Hill-RBF (84%, 74 eyes), again followed by Kane (71, 81%), EVO, Pearl DGS, Hoffer QST, BUII (each 80%, 70 eyes), Cooke K6 (78%, 69 eyes), and SRK/T (74%). Again, no statistically significant difference was found ( P = .39). CONCLUSIONS: Using a recently introduced ESCRS online IOL calculator in multifocal IOLs leds to a high number of eyes reaching target refraction and low prediction errors. All formulas performed similarly well. Hill-RBF showed the highest number of eyes within ±0.5 D, but no significance was found.


Assuntos
Lentes Intraoculares , Lentes Intraoculares Multifocais , Facoemulsificação , Humanos , Pessoa de Meia-Idade , Idoso , Acuidade Visual , Inteligência Artificial , Refração Ocular , Estudos Retrospectivos , Biometria , Óptica e Fotônica , Comprimento Axial do Olho
6.
J Refract Surg ; 39(8): 510-517, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37578179

RESUMO

PURPOSE: To evaluate the levels of habituation and its influence on outcome satisfaction in patients who underwent bilateral multifocal intraocular lens (IOL) implantation. METHODS: A total of 24 patients underwent bilateral multifocal IOL implantation surgery with the AcrySof IQ PanOptix trifocal diffractive IOL (Alcon Laboratories, Inc) following cataract extraction or for refractive purposes. Data were collected 3 and 6 months after surgery, which included subjective refraction, corrected and uncorrected visual acuity (distance, intermediate, near), a contrast sensitivity test, simulation with the Halo & Glare Simulator (Carl Zeiss Meditec AG), two visual quality surveys, and a slit-lamp examination by an ophthalmologist. RESULTS: All patients were spectacle independent for distance vision and 92% (n = 22) needed no visual aid for near vision. Minor visual acuity improvement was detected between both examinations at monocular uncorrected distance visual acuity (P = .025). Improvements of presence, size, and intensity of visual disturbances were not statistically significant, but overall patient satisfaction (P = .009) and Weber-Contrast sensitivity under mesopic conditions (P = .029) increased significantly. CONCLUSIONS: Diffractive multifocal IOLs are a stable treatment for presbyopia and/or cataract with a high spectacle independence rate. Visual disturbances caused by their optics do not decrease significantly between 3 and 6 months after surgery. Habituation and neuroadaptation play a significant role in patient satisfaction and contrast sensitivity during and possibly beyond that period. [J Refract Surg. 2023;39(8):510-517.].

7.
J Cataract Refract Surg ; 49(2): 126-132, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36255226

RESUMO

PURPOSE: To develop and evaluate reliable formulas for predicting postoperative vault more accurately after implantable collamer lens (ICL) surgery in a White patient population with varying degrees of ametropia. SETTING: Private clinical practice. DESIGN: Retrospective analysis on dataset split into a separate training and test set. METHODS: 115 eyes of 59 patients were used to train regression models predicting postoperative vault based on anterior segment optical coherence tomography (OCT) parameters (Least Absolute Shrinkage and Selection Operator [LASSO]-OCT formula), ocular biometry data (LASSO-Biometry formula), or data from both devices (LASSO-Full formula). The performance of these models was evaluated against the manufacturer's nomogram (Online Calculation and Ordering System [OCOS]) and Nakamura 1 (NK1) and 2 (NK2) formulas on a matched separate test set of 37 eyes of 19 patients. RESULTS: The mean preoperative spherical equivalent was -5.32 ± 3.37 (range: +3.75 to -17.375 diopters). The mean absolute errors of the estimated vs achieved postoperative vault for the LASSO-Biometry, LASSO-OCT, and LASSO-Full formulas were 144.1 ± 107.9 µm, 145.6 ± 100.6 µm, and 132.0 ± 86.6 µm, respectively. These results were significantly lower compared with the OCOS, NK1, and NK2 formulas ( P < .006). Postoperative vault could be estimated within 500 µm in 97.3% (LASSO-Biometry) to 100% of cases (LASSO-OCT and LASSO-Full). CONCLUSIONS: The LASSO suite provided a set of powerful, reproducible yet convenient ICL sizing formulas with state-of-the-art performance in White patients, including those with low to moderate degrees of myopia. The calculator can be accessed at http://icl.emmetropia.be .


Assuntos
Cristalino , Lentes Intraoculares Fácicas , Humanos , Implante de Lente Intraocular , Estudos Retrospectivos , Olho
8.
Am J Ophthalmol ; 244: 166-174, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35853490

RESUMO

PURPOSE: To evaluate formulas for intraocular lens (IOL) calculation in silicone oil (SO)-filled eyes. DESIGN: Retrospective, consecutive case series. METHODS: We conducted our study at the Department of Ophthalmology, Goethe University, Frankfurt, Germany, and included SO-filled eyes that received SO removal combined with phacoemulsification and IOL implantation. Preoperative assessments included biometry (IOLMaster 700; Carl Zeiss Meditec). To evaluate the measurements, we compared the mean prediction error, and mean and median absolute prediction error of 8 different formulas. RESULTS: A total of 90 eyes matched our inclusion criteria. The median absolute error was lowest in the Barrett Universal II formula (0.43 diopters [D] ± 0.75) followed by Kane (0.44 D ± 0.75), Hill-radial basis function (0.47 D ± 0.74), Holladay II (0.47 D ± 0.77), Sanders Retzlaff Kraff/theoretical (0.51 D ± 0.74), Holladay I (0.51 D ± 0.76), and Haigis and Hoffer Q (0.52 D ± 0.74 each). Regarding eyes within ±0.5 D Barrett Universal II (57.8%, 52 eyes) performed best, again followed by Kane (56.7%, 51 eyes) and Hill-radial basis function (54.4%, 49 eyes). CONCLUSION: Using modern formulas for IOL calculation in oil-filled eyes improves predictability but still not as good as in unoperated eyes. This issue is created by the change in refractive index due to the SO fill and therefore a lower precision of axial length measurement and effective lens position prediction.


Assuntos
Lentes Intraoculares , Facoemulsificação , Descolamento Retiniano , Humanos , Óleos de Silicone , Descolamento Retiniano/cirurgia , Implante de Lente Intraocular , Estudos Retrospectivos , Refração Ocular , Óptica e Fotônica , Acuidade Visual , Biometria , Comprimento Axial do Olho
9.
Transl Vis Sci Technol ; 11(6): 20, 2022 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-35731540

RESUMO

Purpose: To determine the accuracy and precision of corneal lenticule creation with a new solid-state femtosecond laser in a porcine eye model. Methods: Corneal lenticule creation was performed using a new solid-state femtosecond laser on 60 porcine eyes with 10 subgroups. Optical coherence tomography images were acquired immediately after laser treatment. Cap thickness (CT), cap diameter (CD), and lenticule thickness (LT) were measured manually by three independent readers. Additionally, CT and LT were measured by an automated algorithm (aLT, aCT). Results: Measured LT was significantly greater than the intended LT (average difference 14.3 ± 5.6 µm, P < 0.001). aLT was closer but still significantly different from the intended LT (-2.9 ± 5.8 µm, P < 0.001). Measured CT showed no significant difference from the intended CT (2.6 ± 13.3, P = 0.145). aCT was significantly smaller compared to the intended CT (-9.6 ± 13.6, P < 0.001). Measured CD was significantly smaller compared to the intended CD (-0.21 ± 0.20 mm, P < 0.001). All lenticules were cut as planned with no laser-related complications. Conclusions: This new solid-state femtosecond laser used in our trial provides corneal lenticule creation in a porcine eye model comparable to other established systems. However, measuring those lenticules in the provided setting seems too challenging even when using semiautomated algorithms, which seems to be due to the experimental setting of the trial. Translational Relevance: This trial shows the precision and repeatability of corneal cuts performed by a new femtosecond laser that could translate to refractive corneal lenticule surgery.


Assuntos
Cirurgia da Córnea a Laser , Animais , Córnea/diagnóstico por imagem , Córnea/cirurgia , Substância Própria/cirurgia , Cirurgia da Córnea a Laser/métodos , Lasers de Excimer/uso terapêutico , Suínos , Tomografia de Coerência Óptica
11.
J Cataract Refract Surg ; 48(4): 421-428, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-34417785

RESUMO

PURPOSE: To evaluate factors that influence postoperative satisfaction in patients with diffractive extended depth-of-focus (EDoF) and multifocal intraocular lenses (mIOLs). SETTING: Department of Ophthalmology, Goethe-University, Frankfurt am Main, Germany. DESIGN: Observational case study. METHODS: Patients were evaluated after implantation of a diffractive EDoF (Symfony, AT LARA) or trifocal/quadrifocal (AT LISAtri, Panoptix) 3 months postoperatively. A subjective refraction was performed, uncorrected and corrected visual acuities were tested for distance (UDVA, CDVA), intermediate (at 60 cm and 80 cm, UIVA, DCIVA), and near (at 40 cm, UNVA, DCNVA). A test for contrast sensitivity was performed, and the patients filled 2 different questionnaires on daily activities and optical phenomena. Parameters with a potential correlation to the postoperative overall satisfaction were investigated. RESULTS: 94 patients with a mean age of 66 ± 19 years were included. Patients with a better UDVA and UIVA at 60 cm were more likely to choose the same IOL again. The intensity of subjective optical phenomena and the visual quality at different tasks of daily living influenced overall satisfaction. UIVA at 80 cm, UNVA, and corrected visual acuity demonstrated no significant influence on patient satisfaction. The uncorrected visual acuity at specific distances had a direct impact on the subjective visual quality regarding the task performed at those distances. CONCLUSIONS: For patients with diffractive EDoF and tri-/quadrifocal IOLs, the UDVA and UIVA at 60 cm seem to be more important than the UNVA and UIVA at 80 cm. Subjective visual quality and optical phenomena influence patient satisfaction, as well.


Assuntos
Lentes Intraoculares , Facoemulsificação , Idoso , Idoso de 80 Anos ou mais , Humanos , Implante de Lente Intraocular , Pessoa de Meia-Idade , Medidas de Resultados Relatados pelo Paciente , Satisfação do Paciente , Satisfação Pessoal , Estudos Prospectivos , Desenho de Prótese , Pseudofacia/cirurgia , Refração Ocular , Visão Binocular
12.
J Cataract Refract Surg ; 48(2): 144-150, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-34653094

RESUMO

PURPOSE: To evaluate visual performance and patient-reported outcomes after bilateral implantation of a new nondiffractive wavefront-shaping extended depth-of-focus (EDoF) intraocular lens (IOL). SETTING: Department of Ophthalmology, Goethe University, Frankfurt, Germany. DESIGN: Prospective, single-arm, single-center study. METHODS: Patient population: 16 patients (32 eyes) who received bilateral implantation of a nondiffractive wavefront-shaping EDoF IOL (AcrySof IQ Vivity) were included. Target refraction in both eyes was emmetropia. Observation procedure: Monocular and binocular uncorrected (UCVA) and distance-corrected (DCVA) visual acuity (VA), refractive outcome, defocus curve, and contrast sensitivity (CS) were evaluated 3 months after surgery with a questionnaire on optical phenomena and spectacle independence. Main outcome measure: 3-month postoperative monocular and binocular UCVA and CDVA (logMAR), defocus curve, CS, and quality of vision (QoV) questionnaire results. RESULTS: 16 patients with 32 eyes were included. Mean spherical equivalent was -0.16 ± 0.37 diopters (D) 3 months postoperatively. Binocular uncorrected distance VA at distance, intermediate, and near was 0.01 ± 0.05 logMAR at 4 m, 0.05 ± 0.05 logMAR at 80 cm, 0.07 ± 0.06 logMAR at 66 cm, and 0.25 ± 0.11 logMAR at 40 cm, respectively. Despite some minor optical phenomena, 88% of patients would choose the same lens. 63% of patients reported no optical phenomena at all. CS was 1.25 ± 0.41 logCS (photopic), 0.96 ± 0.24 logCS (mesopic), and 0.93 ± 0.24 (mesopic + glare). CONCLUSIONS: This nondiffractive wavefront-shaping EDoF IOL provides good VA at far and intermediate distance and functional near VA. It showed good QoV and CS and high spectacle independence for distance and intermediate vision with significantly less optical phenomena than with other EDoF or multifocal IOLs.


Assuntos
Lentes Intraoculares , Facoemulsificação , Humanos , Medidas de Resultados Relatados pelo Paciente , Estudos Prospectivos , Desenho de Prótese , Pseudofacia , Refração Ocular , Visão Binocular
13.
Clin Ophthalmol ; 15: 2867-2873, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34262246

RESUMO

PURPOSE: To compare the effective lens position (ELP), anterior chamber depth (ACD) changes, and visual outcomes in patients with and without pseudoexfoliation syndrome (PEX) after cataract surgery. DESIGN: Prospective, randomized, fellow-eye controlled clinical case series. METHODS: This prospective comparative case series enrolled 56 eyes of 56 consecutive patients with (n = 28) or without PEX (n = 28) and clinically significant cataract who underwent standard phacoemulsification and were implanted with single-piece acrylic posterior chamber intraocular lenses (IOLs). The primary outcome parameters were the ACD referring to the distance between the corneal anterior surface and the lens anterior surface, which is an indicator of the postoperative axial position of the IOL (the so-called ELP) and distance corrected visual acuity (DCVA). RESULTS: Before surgery, the ACD was 2.54 ± 0.42 mm in the PEX group and 2.53 ± 0.38 mm in the control group (p = 0.941). Postoperatively, the ACD was 4.29 ± 0.71 mm in the PEX group and 4.33 ± 0.72 mm in the normal group, respectively (p = 0.533). There was no significant difference in ACD changes between groups (PEX group: 1.75 ± 0.74 mm, control group: 1.81 ± 0.61 mm, p = 0.806) and DCVA pre- (p = 0.469) and postoperatively (PEX group: 0.11 ± 0.13 logMAR, control group: 0.09 ± 0.17 logMAR, p = 0.245) between groups. CONCLUSION: Preoperative and postoperative ACD, as an indicator of ELP, between PEX eyes and healthy eyes after cataract surgery showed no significant difference. Phacoemulsification induced similar changes in eyes with PEX compared to healthy eyes.

14.
J Refract Surg ; 37(4): 231-239, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34038658

RESUMO

PURPOSE: To evaluate a ray-tracing formula for intraocular lens (IOL) calculation of diffractive extended depth of focus IOLs after myopic laser in situ keratomileusis (LASIK) compared to formulas from an established online calculator. METHODS: This retrospective, consecutive case series included patients after cataract surgery with implantation of an extended depth of focus (EDOF) IOL (AT LARA, Carl Zeiss Meditec; Symfony, Johnson & Johnson) and a history of myopic LASIK. Preoperative assessments included biometry (IOLMaster; Carl Zeiss Meditec) and corneal tomography, including true net power (TNP) (Pentacam; Oculus Optikgeräte GmbH). To evaluate the measurements, the simulated keratometry values (SimK) were compared to the TNP. Regarding IOL calculation, the mean prediction error, mean and median absolute prediction error (MAE and MedAE), and number of eyes within ±0.50, ±1.00, and ±2.00 diopters (D) from the Haigis-L, Shammas, and Barrett True K No History formulas to the Potvin-Hill and Haigis with TNP (Pentacam) formulas were compared. RESULTS: Thirty-six eyes matched the inclusion criteria with a mean spherical equivalent of -6.26 ± 3.25 diopters (D) preoperatively and -0.79 ± 0.75 D postoperatively. The mean difference from SimK and TNP was significantly different from zero (P < .001; -1.24 ± 0.81 D). The best performing formulas by MedAE were the Potvin-Hill and Barrett True K No History (0.39 ± 0.78 and 0.64 ± 1.00 D). The formula with the most eyes within ±0.50 D was the Potvin-Hill (64%), followed by the Barrett True K No History (44%). For MAE and percentage of eyes within ±0.50 D, the Potvin-Hill formula was significantly better than the Haigis-L, Shammas, and Haigis-TNP formulas (P < .05). CONCLUSIONS: Calculation of IOLs in patients who had LASIK remains less predicable than calculations for virgin eyes. Using ray-tracing to calculate diffractive EDOF IOLs after myopic LASIK, the Potvin-Hill formula outperformed established formulas in terms of the percentage within target refraction and the MAE. [J Refract Surg. 2021;37(4):231-239.].


Assuntos
Ceratomileuse Assistida por Excimer Laser In Situ , Lentes Intraoculares , Facoemulsificação , Biometria , Humanos , Implante de Lente Intraocular , Óptica e Fotônica , Refração Ocular , Estudos Retrospectivos , Tomografia
15.
J Refract Surg ; 36(10): 638-644, 2020 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-33034355

RESUMO

PURPOSE: To evaluate the visual performance after bilateral implantation of a toric diffractive aspheric multifocal intraocular lens (IOL) with a +2.17 diopters (D) (60 cm) intermediate and a +3.25 D (40 cm) addition (add) power. METHODS: This prospective single-arm study was conducted at the Department of Ophthalmology, Goethe University, Frankfurt, Germany. Twenty-five patients (50 eyes) received bilateral implantation of the toric PanOptix IOL (AcrySof IQ PanOptix; Alcon Research LLC) before enrollment. Exclusion criteria were previous ocular surgeries excluding lens surgery and ocular pathologies or corneal abnormalities. Examination at 3 months postoperatively included manifest refraction; monocular and binocular uncorrected distance (UDVA) and distance-corrected (DCVA) visual acuity at 4 m and 80, 60, and 40 cm; and slit-lamp examination. At 3 months postoperatively, monocular and binocular defocus, binocular contrast sensitivity under photopic and mesopic conditions, and optical phenomena, and spectacle independence were evaluated. RESULTS: Mean refractive spherical equivalent was 0.12 ± 0.380 D and mean refractive cylinder was -0.21 ± 0.237 D at 3 months postoperatively. A significant decrease in refractive cylinder was observed postoperatively (P < .05), with 98% showing a postoperative astigmatism below 0.75 D. Monocular UDVA was better than 0.14 logMAR in all distances. Binocular defocus curve showed peaks at 0.00 D (-0.09 logMAR) and -1.50 and -2.00 D (-0.02 and 0.00 logMAR). The worst values between far (4 m) and near (40 cm) distance were 0.04 logMAR at -1.00 D. Despite some optical phenomena, 92% of patients would choose the same IOL again and recommend it to others. CONCLUSIONS: The visual performance of the toric PanOptix IOL showed good visual acuity at all distances; more than 90% achieved a decrease of refractive cylinder below 0.75 D, high patient satisfaction despite some optical phenomena, and high spectacle independence 3 months postoperatively. [J Refract Surg. 2020;36(10):638-644.].


Assuntos
Lentes Intraoculares , Facoemulsificação , Presbiopia , Humanos , Satisfação do Paciente , Presbiopia/cirurgia , Estudos Prospectivos , Desenho de Prótese , Pseudofacia/cirurgia , Refração Ocular , Inquéritos e Questionários , Tecnologia , Visão Binocular
16.
J Cataract Refract Surg ; 46(7): 944-952, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32773548

RESUMO

PURPOSE: To determine improvement of near visual acuity by bilateral multifocal aspheric laser in situ keratomileusis (LASIK) treatments in presbyopic patients. SETTING: Goethe-University, Frankfurt, Germany. DESIGN: Prospective, nonrandomized trial. METHODS: Thirty presbyopic patients underwent LASIK treatment with a multifocal aspheric ablation profile using an excimer laser (PresbyMAX). The first 15 patients received a multifocal aspheric ablation profile combined with micromonovision. For the consecutive 15 patients, less depth of focus was included on the distance eye (hybrid). Outcome parameters were uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected and distance-corrected intermediate visual acuities, uncorrected near visual acuity (UNVA), and distance-corrected near visual acuity (DCNVA); manifest refraction spherical equivalent; subjective quality of vision; and spectacle independence. RESULTS: The data of 29 patients were analyzed and showed that binocular CDVA changed from -0.16 ± 0.10 logarithm of the minimum angle of resolution (logMAR) preoperatively to 0.05 ± 0.20 logMAR UDVA and -0.06 ± 0.14 logMAR CDVA (P = .000, P = .001) 1 year postoperatively. Near visual acuity improved from 0.47 ± 0.13 logMAR (DCNVA) and 0.48 ± 0.26 logMAR (UNVA) to 0.19 ± 0.19 logMAR (DCNVA, P < .001) and 0.05 ± 0.15 logMAR (UNVA, P < .001). The hybrid and the µ-monovision group did not differ statistically except for a better DCNVA in the µ-monovision patients (0.21 ± 0.15 logMAR vs 0.34 ± 0.17 logMAR, P = .034). Of the hybrid and µ-monovision patients, 21 (72%) and 12 (41%) had a binocular CDVA and UDVA of 20/20 or better, 8 patients (28%) lost 1 line, 3 (10%) lost 2 lines, 4 (14%) lost 3 lines, and 2 (7%) lost 4 lines of CDVA. CONCLUSIONS: The PresbyMAX laser seemed to satisfy most of the patients, although they experienced a loss of CDVA. The gain of near visual acuity and therefore reported less need of spectacles seemed to compensate for this loss.


Assuntos
Ceratomileuse Assistida por Excimer Laser In Situ , Alemanha , Humanos , Lasers de Excimer/uso terapêutico , Medidas de Resultados Relatados pelo Paciente , Estudos Prospectivos , Refração Ocular , Acuidade Visual
17.
Ophthalmologe ; 117(7): 602-608, 2020 Jul.
Artigo em Alemão | MEDLINE | ID: mdl-32617666

RESUMO

Early ophthalmological care of patients in intensive care with SARS-CoV­2 (Severe-Acute-Respiratory-Syndrom-Corona-Virus-2) infections is very time-consuming; however, this approach might prevent other ophthalmological diseases, such as lagophthalmos. There is no difference in ophthalmological treatment between SARS-CoV­2 positive and other intensive care patients. Due to the small number of cases in our observational study, a specific ophthalmological clinical pattern related to SARS-CoV­2 infections cannot currently be identified; however, the increased occurrence of subconjunctival hemorrhage in intensive care SARS-CoV­2 patients is remarkable. It remains unclear how ocular symptoms in SARS-CoV­2 infections are related or how they occur in different stages of the disease. Therefore, further studies are necessary for representative statements.


Assuntos
Betacoronavirus , Infecções por Coronavirus , Oftalmopatias , Pandemias , Pneumonia Viral , COVID-19 , Humanos , Unidades de Terapia Intensiva , SARS-CoV-2
18.
J Cataract Refract Surg ; 46(9): 1240-1246, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32379087

RESUMO

BACKGROUND: To evaluate IOL calculation formulas provided by an online calculation tool from the ASCRS for an extended depth-of-focus (EDOF) IOL after previous myopic laser in situ keratomileusis (LASIK). SETTING: Department of Ophthalmology, Goethe University, Frankfurt, Germany. DESIGN: Retrospective consecutive case series. METHODS: Patients who underwent cataract surgery or refractive lens exchange with implantation of a diffractive EDOF IOL and who had a history of myopic LASIK were included. Biometry, refractive data regarding the LASIK procedure, target refraction, and postoperative refraction were collected. Mean prediction error, mean absolute error (MAE), and the number of eyes within ±0.5 diopters (D), ±1.0 D, ±1.5 D, and ±2.0 D were calculated with the following formulas from the ASCRS calculator: Shammas, Haigis-L, Barrett True-K, Barrett No History, Masket, modified Masket, and the average of all formulas (average). RESULTS: Twenty-five eyes matched the inclusion criteria. Mean spherical equivalent (SE) was -0.81 ± 0.69 D; the mean pre-LASIK SE was -6.4 ± 3.63 D. The formulas ranked by MAE were Shammas (0.7 ± 0.75 D), Haigis-L (0.72 ± 0.57 D), average (0.79 ± 0.8 D), Barrett True-K (1.14 ± 0.89 D), modified Masket (1.4 ± 1.15 D), Barrett No History (1.45 ± 0.7D ), and Masket (1.64 ± 1.27 D). The formulas with the most eyes within ±0.5 D were average (52%), Shammas (48%), and Haigis-L (44%) formulas. CONCLUSIONS: Calculation of IOLs in eyes with a history of refractive surgery remains a challenge. In this study, the Shammas and Haigis-L formulas performed best regarding MAE and percentage of eyes within ±0.5 D; however, the average of all formulas delivered reasonable results.


Assuntos
Ceratomileuse Assistida por Excimer Laser In Situ , Lentes Intraoculares , Facoemulsificação , Biometria , Alemanha , Humanos , Óptica e Fotônica , Refração Ocular , Estudos Retrospectivos
19.
Ophthalmologe ; 117(2): 150-153, 2020 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-31144011

RESUMO

We report the case of a patient with epithelial hyperplasia, peripheral haze and regression after transepithelial photorefractive keratectomy (PRK) for hyperopia outside the limits set by the committee for refractive surgery (KRC). Retreatment was performed on both eyes 1 year postoperatively and later an ablation on the left eye due to scarring. Regardless of these procedures haze, scarring and regression appeared again in both eyes. The patient will currently retain a permanent reduction of visual acuity as another treatment of hyperopia outside the KRC recommendations should not be performed due to the high risk of haze, scarring and regression.


Assuntos
Córnea , Hiperopia , Ceratectomia Fotorrefrativa , Humanos , Lasers de Excimer , Refração Ocular , Resultado do Tratamento
20.
Am J Ophthalmol ; 211: 42-55, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31678559

RESUMO

PURPOSE: To evaluate the safety and efficacy of femtosecond (fs) laser-assisted in situ keratomileusis (LASIK) combined with accelerated corneal cross-linking (LASIK Xtra) compared to conventional fs-LASIK (convLASIK) in high myopic patients. DESIGN: Prospective, randomized, fellow-eye controlled clinical trial. METHODS: Setting: Department of Ophthalmology, Goethe University, Frankfurt/Germany. StudyPopulation: Twenty-six patients with high myopia and/or myopic astigmatism received randomized treatment with LASIK Xtra (30 mW/cm2, 90 seconds with continuous ultraviolet-A) in 1 eye and convLASIK in the other eye. MainOutcomeMeasures: Uncorrected distance visual acuity (UDVA), best spectacle-corrected VA (BSCVA), manifest refractive spherical equivalent (MRSE), endothelial cell count (ECC), and corneal thickness. RESULTS: The UDVA improved from 1.26 ± 0.13 logMAR preoperative to -0.02 ± 0.15logMAR in LASIK Xtra eyes and from 1.27 ± 0.12 logMAR to 0.01 ± 0.15 logMAR in the convLASIK eyes (P > .05). The MRSE changed from -7.35 ± 1.15 diopters (D) and -7.5 ± 1.12 D to -0.17 ± 0.43 D and -0.25 ± 0.46 D, respectively. There was no significant difference in outcomes between both groups during the 12 months follow-up except for the convLASIK eyes' showing slightly better BSCVA after 1 week (P < .05). ConvLASIK eyes revealed a nonsignificant trend toward myopic regression from 3 to 12 months postoperative with a change in MRSE of -0.15 D compared to -0.1 D in LASIK Xtra eyes. Topography showed stability of corneal curvature with no signs of keratectasia in both groups at 12 months. CONCLUSION: While apparently safe, LASIK Xtra showed no advantages over conventional LASIK. At 12 months, both groups showed no difference regarding UDVA and refractive stability, and no signs of keratectasia.


Assuntos
Reagentes de Ligações Cruzadas , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Lasers de Excimer/uso terapêutico , Miopia Degenerativa/terapia , Fotoquimioterapia/métodos , Adulto , Contagem de Células , Colágeno/metabolismo , Terapia Combinada , Substância Própria/efeitos dos fármacos , Substância Própria/metabolismo , Topografia da Córnea , Endotélio Corneano/patologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Miopia Degenerativa/tratamento farmacológico , Miopia Degenerativa/metabolismo , Miopia Degenerativa/cirurgia , Fármacos Fotossensibilizantes/uso terapêutico , Estudos Prospectivos , Refração Ocular/fisiologia , Riboflavina/uso terapêutico , Resultado do Tratamento , Raios Ultravioleta , Acuidade Visual/fisiologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA