Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Ultrasonics ; 41(3): 191-6, 2003 May.
Artigo em Inglês | MEDLINE | ID: mdl-12726940

RESUMO

The mechanical pre-stress applied in piezotransducers used to generate high power ultrasound is needed to avoid ceramics fracture on traction cycle. Pre-stress levels inferior to 50 MPa can yield resonance shifting due to effectiveness of acoustic coupling between transducer pieces. Symmetrical transducers with different thickness of passive parts were submitted to axial mechanical pre-stress up to 50 MPa and their resonances were measured. The experimental results show the increasing of the resonances frequencies with the level of applied pre-stress. Similar effect is verified in simulations by using a model based on Mason's equivalent electric circuit. Due to the similarity of these effects, a relation between applied pre-stress and pieces coupling was proposed for the transducer assembled. In addition, the dependence of the thickness of non-piezoelectric pieces on the coupling effectiveness between them is discussed. The results show that transducers with small thickness present more expressive shifting resonance ratio.

2.
IEEE Trans Biomed Eng ; 48(4): 495-9, 2001 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11322538

RESUMO

Designs for a low-cost dual wavelength transducer based on light transmittance and a disposable cuvette for monitoring oxygen saturation (SO2) in extracorporeal arterial and venous blood are presented. The transducer utilizes red and infrared light-emitting diodes and a large photodiode; it is designed to attach to a flow-through cuvette modified from 3/8-in x3/8-in bypass-circuit connectors. A mock extracorporeal circulation system was assembled to evaluate operation of the transducer at a controlled blood SO2 and the relationship between light transmittance and hemodilution. SO2 was calculated based on multiple linear regression analyses. The results show a high correlation between the SO2 obtained with the equipment designed and values measured with commercial gasometric equipment in the range of 50% to 100% (r2 = 0.976, error <2%). The method presented allows continuous and real time measurement of whole blood SO2 with a low-cost transmittance transducer.


Assuntos
Circulação Extracorpórea/instrumentação , Oxigênio/sangue , Transdutores , Animais , Bovinos , Controle de Custos , Desenho de Equipamento , Hemoglobinas , Análise de Regressão , Transdutores/economia
3.
Ultrasonics ; 39(1): 1-5, 2001 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11205579

RESUMO

The piezotransducers employed in high power ultrasound are composed of piezoelectric ceramics and metallic pieces. These transducers are mechanically pre-stressed in order to avoid the ceramic fractures when high voltage is applied under resonance. The resonance and anti-resonance frequencies are shifted depending on the level of applied mechanical pre-stressing. This paper discusses some causes of this shifting on a experimental study. The discussion takes into account the variations on characteristic parameters of the ceramics and the acoustic coupling between parts of the transducer.


Assuntos
Transdutores , Ultrassonografia/instrumentação , Acústica , Cerâmica , Análise de Falha de Equipamento , Humanos , Metais , Estresse Mecânico
4.
Ultrasonics ; 39(1): 7-11, 2001 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11205588

RESUMO

Composed piezotransducers submitted to mechanical pre-stressing present shifts on resonance and anti-resonance frequencies. Changes on characteristic parameters of the ceramic and in the coupling between the parts of the transducer can be the causes for this behavior. In applications where the level of pre-stressing is low (up to 50 MPa) the parameters of the ceramic are not altered, therefore, the shifting on frequencies are attributed to coupling between parts. This paper describes a mathematical model to explain this effect based on difference of effective cross-section between transducers parts under pre-stressing. The results show a proportional relation between pre-stressing and effective coupling of the parts.


Assuntos
Transdutores , Ultrassonografia/instrumentação , Cerâmica , Condutividade Elétrica , Análise de Falha de Equipamento , Humanos , Metais , Modelos Teóricos , Estresse Mecânico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA