Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
2.
IUCrJ ; 5(Pt 5): 531-541, 2018 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-30224956

RESUMO

Diffraction before destruction using X-ray free-electron lasers (XFELs) has the potential to determine radiation-damage-free structures without the need for crystallization. This article presents the three-dimensional reconstruction of the Melbournevirus from single-particle X-ray diffraction patterns collected at the LINAC Coherent Light Source (LCLS) as well as reconstructions from simulated data exploring the consequences of different kinds of experimental sources of noise. The reconstruction from experimental data suffers from a strong artifact in the center of the particle. This could be reproduced with simulated data by adding experimental background to the diffraction patterns. In those simulations, the relative density of the artifact increases linearly with background strength. This suggests that the artifact originates from the Fourier transform of the relatively flat background, concentrating all power in a central feature of limited extent. We support these findings by significantly reducing the artifact through background removal before the phase-retrieval step. Large amounts of blurring in the diffraction patterns were also found to introduce diffuse artifacts, which could easily be mistaken as biologically relevant features. Other sources of noise such as sample heterogeneity and variation of pulse energy did not significantly degrade the quality of the reconstructions. Larger data volumes, made possible by the recent inauguration of high repetition-rate XFELs, allow for increased signal-to-background ratio and provide a way to minimize these artifacts. The anticipated development of three-dimensional Fourier-volume-assembly algorithms which are background aware is an alternative and complementary solution, which maximizes the use of data.

3.
Sci Data ; 4: 170079, 2017 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-28654088

RESUMO

Single-particle diffraction from X-ray Free Electron Lasers offers the potential for molecular structure determination without the need for crystallization. In an effort to further develop the technique, we present a dataset of coherent soft X-ray diffraction images of Coliphage PR772 virus, collected at the Atomic Molecular Optics (AMO) beamline with pnCCD detectors in the LAMP instrument at the Linac Coherent Light Source. The diameter of PR772 ranges from 65-70 nm, which is considerably smaller than the previously reported ~600 nm diameter Mimivirus. This reflects continued progress in XFEL-based single-particle imaging towards the single molecular imaging regime. The data set contains significantly more single particle hits than collected in previous experiments, enabling the development of improved statistical analysis, reconstruction algorithms, and quantitative metrics to determine resolution and self-consistency.


Assuntos
Colífagos , Algoritmos , Estrutura Molecular , Difração de Raios X
4.
IUCrJ ; 4(Pt 3): 251-262, 2017 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-28512572

RESUMO

This study explores the capabilities of the Coherent X-ray Imaging Instrument at the Linac Coherent Light Source to image small biological samples. The weak signal from small samples puts a significant demand on the experiment. Aerosolized Omono River virus particles of ∼40 nm in diameter were injected into the submicrometre X-ray focus at a reduced pressure. Diffraction patterns were recorded on two area detectors. The statistical nature of the measurements from many individual particles provided information about the intensity profile of the X-ray beam, phase variations in the wavefront and the size distribution of the injected particles. The results point to a wider than expected size distribution (from ∼35 to ∼300 nm in diameter). This is likely to be owing to nonvolatile contaminants from larger droplets during aerosolization and droplet evaporation. The results suggest that the concentration of nonvolatile contaminants and the ratio between the volumes of the initial droplet and the sample particles is critical in such studies. The maximum beam intensity in the focus was found to be 1.9 × 1012 photons per µm2 per pulse. The full-width of the focus at half-maximum was estimated to be 500 nm (assuming 20% beamline transmission), and this width is larger than expected. Under these conditions, the diffraction signal from a sample-sized particle remained above the average background to a resolution of 4.25 nm. The results suggest that reducing the size of the initial droplets during aerosolization is necessary to bring small particles into the scope of detailed structural studies with X-ray lasers.

5.
Sci Rep ; 6: 33170, 2016 09 12.
Artigo em Inglês | MEDLINE | ID: mdl-27616740

RESUMO

Omono River virus (OmRV) is a double-stranded RNA virus isolated from Culex mosquitos, and it belongs to a group of unassigned insect viruses that appear to be related to Totiviridae. This paper describes electron cryo-microscopy (cryoEM) structures for the intact OmRV virion to 8.9 Å resolution and the structure of the empty virus-like-particle, that lacks RNA, to 8.3 Å resolution. The icosahedral capsid contains 120-subunits and resembles another closely related arthropod-borne totivirus-like virus, the infectious myonecrosis virus (IMNV) from shrimps. Both viruses have an elevated plateau around their icosahedral 5-fold axes, surrounded by a deep canyon. Sequence and structural analysis suggests that this plateau region is mainly composed of the extended C-terminal region of the capsid proteins. In contrast to IMNV, the infectious form of OmRV lacks extensive fibre complexes at its 5-fold axes as directly confirmed by a contrast-enhancement technique, using Zernike phase-contrast cryo-EM. Instead, these fibre complexes are replaced by a short "plug" structure at the five-fold axes of OmRV. OmRV and IMNV have acquired an extracellular phase, and the structures at the five-fold axes may be significant in adaptation to cell-to-cell transmission in metazoan hosts.


Assuntos
Capsídeo/ultraestrutura , Totiviridae/ultraestrutura , Vírion/ultraestrutura , Aedes/virologia , Sequência de Aminoácidos , Animais , Proteínas do Capsídeo/química , Proteínas do Capsídeo/ultraestrutura , Células Cultivadas , Microscopia Crioeletrônica , Insetos Vetores/virologia , Modelos Moleculares , Domínios Proteicos , Estrutura Quaternária de Proteína
6.
Sci Data ; 3: 160064, 2016 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-27478984

RESUMO

Single particle diffractive imaging data from Rice Dwarf Virus (RDV) were recorded using the Coherent X-ray Imaging (CXI) instrument at the Linac Coherent Light Source (LCLS). RDV was chosen as it is a well-characterized model system, useful for proof-of-principle experiments, system optimization and algorithm development. RDV, an icosahedral virus of about 70 nm in diameter, was aerosolized and injected into the approximately 0.1 µm diameter focused hard X-ray beam at the CXI instrument of LCLS. Diffraction patterns from RDV with signal to 5.9 Ångström were recorded. The diffraction data are available through the Coherent X-ray Imaging Data Bank (CXIDB) as a resource for algorithm development, the contents of which are described here.


Assuntos
Oryza/virologia , Reoviridae/isolamento & purificação , Vírion , Algoritmos , Aceleradores de Partículas , Raios X
7.
Sci Data ; 3: 160061, 2016 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-27479842

RESUMO

Ultra-intense femtosecond X-ray pulses from X-ray lasers permit structural studies on single particles and biomolecules without crystals. We present a large data set on inherently heterogeneous, polyhedral carboxysome particles. Carboxysomes are cell organelles that vary in size and facilitate up to 40% of Earth's carbon fixation by cyanobacteria and certain proteobacteria. Variation in size hinders crystallization. Carboxysomes appear icosahedral in the electron microscope. A protein shell encapsulates a large number of Rubisco molecules in paracrystalline arrays inside the organelle. We used carboxysomes with a mean diameter of 115±26 nm from Halothiobacillus neapolitanus. A new aerosol sample-injector allowed us to record 70,000 low-noise diffraction patterns in 12 min. Every diffraction pattern is a unique structure measurement and high-throughput imaging allows sampling the space of structural variability. The different structures can be separated and phased directly from the diffraction data and open a way for accurate, high-throughput studies on structures and structural heterogeneity in biology and elsewhere.


Assuntos
Ciclo do Carbono , Halothiobacillus/ultraestrutura , Organelas , Halothiobacillus/metabolismo , Organelas/ultraestrutura , Raios X
8.
Opt Express ; 22(23): 28914-25, 2014 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-25402130

RESUMO

We use a Mach-Zehnder type autocorrelator to split and delay XUV pulses from the FLASH soft X-ray laser for triggering and subsequently probing the explosion of aerosolised sugar balls. FLASH was running at 182 eV photon energy with pulses of 70 fs duration. The delay between the pump-probe pulses was varied between zero and 5 ps, and the pulses were focused to reach peak intensities above 10¹6W/cm² with an off-axis parabola. The direct pulse triggered the explosion of single aerosolised sucrose nano-particles, while the delayed pulse probed the exploding structure. The ejected ions were measured by ion time of flight spectrometry, and the particle sizes were measured by coherent diffractive imaging. The results show that sucrose particles of 560-1000 nm diameter retain their size for about 500 fs following the first exposure. Significant sample expansion happens between 500 fs and 1 ps. We present simulations to support these observations.


Assuntos
Elétrons , Imageamento Tridimensional/métodos , Lasers , Nanosferas/química , Análise Espectral/métodos , Sacarose/química , Simulação por Computador , Hidrogênio/química , Íons , Termodinâmica , Raios X