Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
J Neurooncol ; 159(3): 519-529, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35852737

RESUMO

PURPOSE: To investigate the potential of radiomics applied to static clinical PET data using the tracer O-(2-[18F]fluoroethyl)-L-tyrosine (FET) to differentiate treatment-related changes (TRC) from tumor progression (TP) in patients with gliomas. PATIENTS AND METHODS: One hundred fifty-one (151) patients with histologically confirmed gliomas and post-therapeutic progressive MRI findings according to the response assessment in neuro-oncology criteria underwent a dynamic amino acid PET scan using the tracer O-(2-[18F]fluoroethyl)-L-tyrosine (FET). Thereof, 124 patients were investigated on a stand-alone PET scanner (data used for model development and validation), and 27 patients on a hybrid PET/MRI scanner (data used for model testing). Mean and maximum tumor to brain ratios (TBRmean, TBRmax) were calculated using the PET data from 20 to 40 min after tracer injection. Logistic regression models were evaluated for the FET PET parameters TBRmean, TBRmax, and for radiomics features of the tumor areas as well as combinations thereof to differentiate between TP and TRC. The best performing models in the validation dataset were finally applied to the test dataset. The diagnostic performance was assessed by receiver operating characteristic analysis. RESULTS: Thirty-seven patients (25%) were diagnosed with TRC, and 114 (75%) with TP. The logistic regression model comprising the conventional FET PET parameters TBRmean and TBRmax resulted in an AUC of 0.78 in both the validation (sensitivity, 64%; specificity, 80%) and the test dataset (sensitivity, 64%; specificity, 80%). The model combining the conventional FET PET parameters and two radiomics features yielded the best diagnostic performance in the validation dataset (AUC, 0.92; sensitivity, 91%; specificity, 80%) and demonstrated its generalizability in the independent test dataset (AUC, 0.85; sensitivity, 81%; specificity, 70%). CONCLUSION: The developed radiomics classifier allows the differentiation between TRC and TP in pretreated gliomas based on routinely acquired static FET PET scans with a high diagnostic accuracy.


Assuntos
Neoplasias Encefálicas , Glioma , Neoplasias Encefálicas/diagnóstico por imagem , Glioma/patologia , Humanos , Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons , Tirosina
2.
Eur Spine J ; 29(5): 986-993, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31982957

RESUMO

PURPOSE: The aim of this study is to detect the presence of blood spinal cord barrier (BSCB) disruption in patients with degenerative cervical myelopathy (DCM). METHODS: In this prospective non-randomized controlled cohort study, 28 patients with DCM were prospectively included. All patients had indication for neurosurgical decompression. Furthermore, 38 controls with thoracic abdominal aortic aneurysm (TAAA) and indication for surgery were included. All patients underwent neurological examination. Regarding BSCB disruption and intrathecal immunoglobulin (Ig) concentrations, cerebrospinal fluid (CSF) and blood serum were examined for albumin, IgG, IgA and IgM. Quotients (Q) (CSF/serum) were standardized and calculated according to Reibers' diagnostic criteria. RESULTS: Patients and controls distinguished significantly in their clinical status. AlbuminQ, as expression of BSCB disruption, was significantly increased in the DCM patients compared to the controls. Quotients of IgG and IgA differed significantly between the groups as an expression of intrathecal diffusion. In the subgroup analysis of patients with mild/moderate clinical status of myelopathy and patients with severe clinical status, the disruption of the BSCB was significantly increased with clinical severity. Likewise, IgAQ and IgGQ presented increased quotients related to the clinical severity of myelopathy. CONCLUSION: In this study, we detected an increased permeability and disruption of the BSCB in DCM patients. The severity of BSCB disruption and the diffusion of Ig are related to the clinical status in our patient cohort. Having documented this particular pathomechanism in patients with DCM, we suggest that this diagnostic tool cloud be an important addition to surgical decision making in the future. These slides can be retrieved under Electronic Supplementary Material.


Assuntos
Vértebras Cervicais , Doenças da Medula Espinal , Estudos de Coortes , Humanos , Estudos Prospectivos , Medula Espinal , Doenças da Medula Espinal/cirurgia
3.
World Neurosurg ; 135: e382-e385, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31816454

RESUMO

BACKGROUND: Recent studies imply an association between aneurysm wall enhancement (AWE) on contrast-enhanced magnetic resonance imaging and aneurysm rupture. We investigated the prevalence and clinical significance of AWE and enhancement within the aneurysm (inner enhancement [IE]) in coiled aneurysms. METHODS: We assessed the frequency of AWE and IE after coil embolization on postinterventional magnetic resonance imaging (<6 weeks) in 30 consecutive patients with 33 aneurysms and elucidated the association between enhancement and subsequent aneurysm recurrence or hemorrhage. RESULTS: AWE and IE occurred in 97% and 36% of cases, respectively. There was no rehemorrhage, and there was no significant association between subsequent reperfusion and AWE (P = 0.200) or IE (P = 0.148) during a median follow-up period of 19 months. The greatest share of IE (8 of 12 aneurysms) was found in incompletely coiled aneurysms with small remnants (P = 0.001). CONCLUSIONS: AWE after coil embolization cannot be used for recurrence risk stratification owing to its high prevalence. IE is likely to represent contrast inflow in the coiled aneurysm.


Assuntos
Embolização Terapêutica/métodos , Aneurisma Intracraniano/terapia , Meios de Contraste , Feminino , Humanos , Aneurisma Intracraniano/patologia , Angiografia por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Prognóstico , Recidiva
4.
J Neuroradiol ; 45(5): 290-294, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29412162

RESUMO

PURPOSE: To assess the diagnostic utility of different perfusion algorithms for the detection of angiographical terial spasm. METHOD: During a 2-year period, 45 datasets from 29 patients (54.2±10,75y, 20F) with suspected cerebral vasospasm after aneurysmal subarachnoid hemorrhage were included. Volume Perfusion CT (VPCT), Non-enhanced CT (NCT) and angiography were performed within 6hours post-ictus. Perfusion maps were generated using a maximum slope (MS) and a deconvolution-based approach (DC). Two blinded neuroradiologists independently evaluated MS and DC maps regarding vasospasm-related perfusion impairment on a 3-point Likert-scale (0=no impairment, 1=impairment affecting <50%, 2=impairment affecting >50% of vascular territory). A third independent neuroradiologist assessed angiography for presence and severity of arterial narrowing on a 3-point Likert scale (0=no narrowing, 1=narrowing affecting <50%, 2=narrowing affecting>50% of artery diameter). MS and DC perfusion maps were evaluated regarding diagnostic accuracy for angiographical arterial spasm with angiography as reference standard. Correlation analysis of angiography findings with both MS and DC perfusion maps was additionally performed. Furthermor, the agreement between MS and DC and inter-reader agreement was assessed. RESULTS: DC maps yielded significantly higher diagnostic accuracy than MS perfusion maps (DC:AUC=.870; MS:AUC=.805; P=0.007) with higher sensitivity for DC compared to MS (DC:sensitivity=.758; MS:sensitivity=.625). DC maps revealed stronger correlation with angiography than MS (DC: R=.788; MS: R=694;=<0.001). MS and DC showed substantial agreement (Kappa=.626). Regarding inter-reader analysis, (almost) perfect inter-reader agreement was observed for both MS and DC maps (Kappa≥981). CONCLUSION: DC yields significantly higher diagnostic accuracy for the detection of angiographic arterial spasm and higher correlation with angiographic findings compared to MS.


Assuntos
Angiografia Cerebral/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Hemorragia Subaracnóidea/complicações , Hemorragia Subaracnóidea/terapia , Tomografia Computadorizada por Raios X/métodos , Vasoespasmo Intracraniano/diagnóstico por imagem , Vasoespasmo Intracraniano/etiologia , Adulto , Idoso , Algoritmos , Angiografia Digital , Meios de Contraste , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade , Hemorragia Subaracnóidea/diagnóstico por imagem
5.
Radiology ; 287(2): 643-650, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29309735

RESUMO

Purpose To evaluate diagnostic accuracy of low-dose volume perfusion (VP) computed tomography (CT) compared with original VP CT regarding the detection of cerebral perfusion impairment after aneurysmal subarachnoid hemorrhage. Materials and Methods In this retrospective study, 85 patients (mean age, 59.6 years; 62 women) with aneurysmal subarachnoid hemorrhage and who were suspected of having cerebral vasospasm at unenhanced CT and VP CT (tube voltage, 80 kVp; tube current-time product, 180 mAs) were included, 37 of whom underwent digital subtraction angiography (DSA) within 6 hours. Low-dose VP CT data sets at tube current-time product of 72 mAs were retrospectively generated by validated realistic simulation. Perfusion maps were generated from both data sets and reviewed by two neuroradiologists for overall image quality, diagnostic confidence and presence and/or severity of perfusion impairment indicating vasospasm. An interventional neuroradiologist evaluated 16 vascular segments at DSA. Diagnostic accuracy of low-dose VP CT was calculated with original VP CT as reference standard. Agreement between findings of both data sets was assessed by using weighted Cohen κ and findings were correlated with DSA by using Spearman correlation. After quantitative volumetric analysis, lesion volumes were compared on both VP CT data sets. Results Low-dose VP CT yielded good ratings of image quality and diagnostic confidence and classified all patients correctly with high diagnostic accuracy (sensitivity, 99.0%; specificity, 99.5%) without significant differences regarding presence and/or severity of perfusion impairment between original and low-dose data sets (Z = -0.447; P = .655). Findings of both data sets correlated significantly with DSA (original, r = 0.671; low dose, r = 0.667). Lesion volume was comparable for both data sets (relative difference, 5.9% ± 5.1 [range, 0.2%-25.0%; median, 4.0%]) with strong correlation (r = 0.955). Conclusion The results suggest that radiation dose reduction to 40% of original dose levels (tube current-time product, 72 mAs) may be performed in VP CT imaging of patients with aneurysmal subarachnoid hemorrhage without compromising the diagnostic accuracy regarding detection of cerebral perfusion impairment indicating vasospasm. © RSNA, 2018 Online supplemental material is available for this article.


Assuntos
Aneurisma Intracraniano/diagnóstico por imagem , Imagem de Perfusão , Hemorragia Subaracnóidea/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Vasoespasmo Intracraniano/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Circulação Cerebrovascular/fisiologia , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Aneurisma Intracraniano/fisiopatologia , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Hemorragia Subaracnóidea/fisiopatologia , Resistência Vascular/fisiologia , Vasoespasmo Intracraniano/fisiopatologia
6.
Perfusion ; 32(8): 691-694, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28578609

RESUMO

We report on a 32-year-old male patient with acute left-hemispheric stroke caused by embolism due to infective endocarditis affected from the HACEK group. Additionally, atypical findings from the transesophageal echocardiography (TEE) which showed fluttering structures belonging to the papillary muscle could be proven as infectious agents with the help of a glucose positron emission tomography (PET) scan. TEE controls showed increasing vegetation involving the mitral valve so that surgery became necessary. The current work reflects, in detail, the emergent clinical course of this young patient, suffering from both an unusual localization and an infrequent cause of endocarditis and focuses on an actual view to the literature.


Assuntos
Endocardite , Adulto , Humanos , Masculino
7.
PLoS One ; 12(5): e0178197, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28542580

RESUMO

Feasibility of endovascular stentectomy using a snare over stent-retriever (SOS) technique was evaluated in a silicon flow model and an in vivo swine model. In vitro, stentectomy of different intracranial stents using the SOS technique was feasible in 22 out of 24 (92%) retrieval maneuvers. In vivo, stentectomy was successful in 10 out of 10 procedures (100%). In one case self-limiting vasospasm was observed angiographically as a technique related complication in the animal model. Endovascular stentectomy using the SOS technique is feasible in an experimental setting and may be transferred to a clinical scenario.


Assuntos
Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/métodos , Falha de Prótese , Stents/efeitos adversos , Animais , Modelos Animais de Doenças , Estudos de Viabilidade , Feminino , Humanos , Falha de Prótese/efeitos adversos , Suínos
8.
World Neurosurg ; 102: 459-465, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28344178

RESUMO

BACKGROUND: Oral nimodipine is an established prophylactic agent for cerebral vasospasm after subarachnoid hemorrhage (SAH). In highly selected cases, intra-arterial (IA) or intravenous (IV) application of nimodipine may be considered; however, the optimum dosage and modality of application remain a matter of debate. The purpose of this investigation is analysis of nimodipine concentration in serum, cerebrospinal fluid, and cerebral microdialysate in the context of currently effective dose and route of application (oral, IA, IV). METHODS: We prospectively collected 156 samples from 37 patients treated for aneurysmal SAH from May 2014 to July 2015. Treatment groups were stratified according to modality of application and low-dose or high-dose treatment. At time of sampling, current dose and modality of application effectively sustained cerebral perfusion as documented by common diagnostics. Samples were analyzed for nimodipine concentration via high-performance liquid chromatography and tandem mass spectrometry. RESULTS: In most cases (94.3%), nimodipine remained below the limit of quantification (0.5 ng/mL) within the brain (microdialysis, cerebrospinal fluid), even during targeted, local application (IA nimodipine). The median serum concentration for all treatment groups was 17.3 ng/mL. Modality of application (oral, IA, IV) was not associated with significant differences in serum concentrations (P = 0.712), even after stratification for dosage (P = 0.371), implying a comparable systemic distribution, if not efficacy. CONCLUSIONS: Nimodipine does not accumulate sufficiently within the target organ for treatment monitoring. Comparable systemic concentrations can be observed irrespective of application modality and dosing. Future studies will clarify the role of efficacy-driven treatment algorithms, in which lowest dose and least invasive mode of application still effective should be identified.


Assuntos
Córtex Cerebral/metabolismo , Nimodipina , Vasodilatadores , Vasoespasmo Intracraniano/tratamento farmacológico , Idoso , Cromatografia Líquida , Relação Dose-Resposta a Droga , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Nimodipina/sangue , Nimodipina/líquido cefalorraquidiano , Nimodipina/uso terapêutico , Estudos Retrospectivos , Estatísticas não Paramétricas , Hemorragia Subaracnóidea/complicações , Espectrometria de Massas em Tandem , Vasodilatadores/sangue , Vasodilatadores/líquido cefalorraquidiano , Vasodilatadores/uso terapêutico , Vasoespasmo Intracraniano/etiologia
9.
Neurosurgery ; 80(6): 942-949, 2017 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-28201539

RESUMO

BACKGROUND: Critical hypoperfusion and metabolic derangement are frequently encountered with refractory vasospasm. Endovascular rescue therapies (ERT) have proven beneficial in selected cases. However, angioplasty (AP) and intraarterial lysis (IAL) are measures of last resort and prospective, quantitative results regarding the efficacy (cerebral oxygenation, metabolism) are largely lacking. OBJECTIVE: To evaluate the efficacy of ERTs for medically refractory vasospasm using multimodal, continuous event neuromonitoring. METHODS: To detect cerebral compromise in a timely fashion, sedated patients with aneurysmal subarachnoid hemorrhage received continuous neuromonitoring (p ti O 2 measurement, intraparenchymal microdialysis). ERT (AP and/or IAL) was considered in cases of clinically relevant vasospasm refractory to conservative treatment measures. Oxygen saturation and cerebral and systemic metabolism before and after events of ERT was recorded. RESULTS: We prospectively included 13 consecutive patients and recorded a total of 25 ERT events: AP (n = 10), IAL (n = 11), or both (AP + IAL, n = 4). Average cerebral p ti O 2 was 10 ± 11 torr before and 49 ± 22 torr after ERT ( P < .001), with a lactate-pyruvate ratio decreasing from 146.6 ± 119.0 to 27.9 ± 10.7 after ERT ( P < .001). Comparable improvement was observed for each type of intervention (AP, IAL, or both). No significant alterations in systemic metabolism could be detected after ERT. CONCLUSION: Multimodal event neuromonitoring is able to quantify treatment efficacy in subarachnoid hemorrhage-related vasospasm. In our small cohort of highly selected cases, ERT was associated with improvement in cerebral oxygenation and metabolism with reasonable outcome. Event neuromonitoring may facilitate individual and timely optimization of treatment modality according to the individual clinical course.


Assuntos
Hemorragia Subaracnóidea/complicações , Vasoespasmo Intracraniano/etiologia , Vasoespasmo Intracraniano/cirurgia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Neurofisiológica/métodos , Estudos Prospectivos , Resultado do Tratamento
10.
J Neurointerv Surg ; 9(3): 253-256, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26975839

RESUMO

BACKGROUND: The optimal interaction between stent struts and thrombus is crucial for successful revascularization in endovascular stroke therapy with stent retrievers. Deploying the stent retriever by actively pushing it into the thrombus increases the radial force with which the stent struts expand into the thrombus. OBJECTIVE: To examine the active push deployment (APD) technique in an in vitro model and present our clinical experience with this technique. METHODS: In an in vitro experiment we investigated the configuration of a Solitaire and a Trevo ProVue device (both 4×20 mm), depending on whether the devices were deployed using the APD technique or simple unsheathing. We retrospectively assessed the effectiveness and safety of this technique by analyzing 130 patients with large vessel occlusions (carotid T or M1 segment of the middle cerebral artery), who received endovascular treatment with a Trevo device (4×20 mm) that was deployed using the APD technique. RESULTS: In vitro experiment: the APD technique improved apposition of the devices to the vessel wall. There was widening of 30% (Trevo) and 19% (Solitaire) at the cost of a shortening of 5% and 4%, respectively, when the devices were deployed in a carotid T model. Clinical study: the revascularization rate (Thrombolysis in Cerebral Infarction ≥2b) with the Trevo device was 90%. There were no retriever-associated dissections or perforations in 278 retrieval maneuvers. CONCLUSIONS: The APD technique improves apposition of the tested devices to the vessel wall. The widening effect comes at the cost of minimal shortening of the devices. Our clinical experience shows that using the APD technique to deploy the Trevo device is effective and safe.


Assuntos
Remoção de Dispositivo/instrumentação , Remoção de Dispositivo/métodos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/métodos , Stents , Acidente Vascular Cerebral/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Isquemia Encefálica/diagnóstico por imagem , Isquemia Encefálica/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Acidente Vascular Cerebral/diagnóstico por imagem , Trombectomia/instrumentação , Trombectomia/métodos , Resultado do Tratamento
11.
J Neurointerv Surg ; 9(4): 336-339, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26992412

RESUMO

BACKGROUND: Epidemiologic studies identified a 'weekend effect' or 'out-of-hours effect', which implies that procedural and clinical outcomes of patients with stroke, who are admitted out-of-hours, are less favorable than for patients admitted during working-hours. OBJECTIVE: To determine (1) whether our procedural times and clinical outcome were affected by an out-of-hours effect and (2) whether the decision in favor of, or against, endovascular stroke treatment (EST) depends on the time of admission. METHODS: Between February 2010 and January 2015, 6412 consecutive patients presenting with symptoms of acute ischemic stroke were evaluated for EST eligibility according to established local protocols and generally accepted consensus criteria, and dichotomized into working-hours and out-of-hours cohorts according to admission times. Within both groups, patients given EST were identified and the rate of treatment decision, procedural times, and clinical outcome were compared and analyzed. RESULTS: Clinical and radiological features of patients admitted in working-hours and out-of-hours did not differ significantly. Procedural times and clinical outcome were not affected by an out-of-hours effect (p≥0.054). 221/240 (92.1%) out-of-hours patients and 154/166 (92.8%) working-hours patients who were eligible for EST were transferred to the angiography suite for EST (p=0.798). The rationale not to treat patients who were eligible for EST did not differ between working-hours and out-of-hours admission (p=0.756). CONCLUSIONS: It is possible to produce competitive procedural times regardless of the time of admission and to prevent a treatment decision bias when standard operating procedures are applied consistently.


Assuntos
Tomada de Decisão Clínica/métodos , Procedimentos Endovasculares/tendências , Admissão do Paciente/tendências , Acidente Vascular Cerebral/cirurgia , Idoso , Idoso de 80 Anos ou mais , Procedimentos Endovasculares/efeitos adversos , Feminino , Hospitalização/tendências , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Acidente Vascular Cerebral/diagnóstico , Fatores de Tempo , Resultado do Tratamento
12.
J Neurointerv Surg ; 9(5): 459-462, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-27084962

RESUMO

BACKGROUND: Flow control during endovascular stroke treatment with stent-retrievers is crucial for successful revascularization. The standard technique recommended by stent-retriever manufacturers implies obstruction of the respective access catheter by the microcatheter, through which the stent-retriever is delivered. This, in turn, results in reduced aspiration during thrombectomy. In order to maximize aspiration, we fully retract the microcatheter out of the access catheter before thrombectomy-an approach we term the 'bare wire thrombectomy' (BWT) technique. We verified the improved throughput with systematic in vitro studies and assessed the clinical effectiveness and safety of this method. METHODS: We compared aspiration flow of water through various access catheters (5-8 F) with a Rebar microcatheter (0.18 inch and 0.27 inch) and a Trevo stent-retriever using the standard technique and the BWT technique in vitro. We also retrospectively analyzed 302 retrieval maneuvers in 117 patients who received endovascular treatment with a stent-retriever between February 2010 and April 2015. RESULTS: In the in vitro experiment, removal of the microcatheter in all tested settings resulted in significantly increased aspiration flow through the access catheter (p<0.001). This effect was particularly pronounced in access catheters with a diameter of ≤7 F. In the clinical study, the revascularization rate (Thrombolysis In Cerebral Infarction ≥2b) was 91%. There were no complications associated with the BWT technique in 302 retrieval maneuvers. CONCLUSIONS: The BWT technique results in improved aspiration flow rates compared with the standard deployment technique. Our clinical data show that the BWT technique is effective and safe.


Assuntos
Catéteres , Stents , Acidente Vascular Cerebral/cirurgia , Trombectomia/instrumentação , Trombectomia/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/fisiopatologia , Resultado do Tratamento , Adulto Jovem
13.
Neuroradiology ; 58(8): 787-92, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27194077

RESUMO

INTRODUCTION: In this study, we aimed to evaluate the diagnostic performance of different volume perfusion CT (VPCT) maps regarding the detection of cerebral vasospasm compared to angiographic findings. METHODS: Forty-one datasets of 26 patients (57.5 ± 10.8 years, 18 F) with subarachnoid hemorrhage and suspected cerebral vasospasm, who underwent VPCT and angiography within 6 h, were included. Two neuroradiologists independently evaluated the presence and severity of vasospasm on perfusion maps on a 3-point Likert scale (0-no vasospasm, 1-vasospasm affecting <50 %, 2-vasospasm affecting >50 % of vascular territory). A third neuroradiologist independently assessed angiography for the presence and severity of vasospasm on a 3-point Likert scale (0-no vasospasm, 1-vasospasm affecting < 50 %, 2-vasospasm affecting > 50 % of vessel diameter). Perfusion maps of cerebral blood volume (CBV), cerebral blood flow (CBF), mean transit time (MTT), and time to drain (TTD) were evaluated regarding diagnostic accuracy for cerebral vasospasm with angiography as reference standard. Correlation analysis of vasospasm severity on perfusion maps and angiographic images was performed. Furthermore, inter-reader agreement was assessed regarding findings on perfusion maps. RESULTS: Diagnostic accuracy for TTD and MTT was significantly higher than for all other perfusion maps (TTD, AUC = 0.832; MTT, AUC = 0.791; p < 0.001). TTD revealed higher sensitivity than MTT (p = 0.007). The severity of vasospasm on TTD maps showed significantly higher correlation levels with angiography than all other perfusion maps (p ≤ 0.048). Inter-reader agreement was (almost) perfect for all perfusion maps (kappa ≥ 0.927). CONCLUSION: The results of this study indicate that TTD maps have the highest sensitivity for the detection of cerebral vasospasm and highest correlation with angiography regarding the severity of vasospasm.


Assuntos
Determinação do Volume Sanguíneo/métodos , Angiografia Cerebral/métodos , Circulação Cerebrovascular , Angiografia por Tomografia Computadorizada/métodos , Interpretação de Imagem Assistida por Computador/métodos , Vasoespasmo Intracraniano/diagnóstico por imagem , Vasoespasmo Intracraniano/fisiopatologia , Adulto , Idoso , Algoritmos , Velocidade do Fluxo Sanguíneo , Volume Sanguíneo , Feminino , Humanos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
J Neurointerv Surg ; 8(7): 714-8, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26024865

RESUMO

PURPOSE: To describe our initial experience with the novel 5 F SOFIA (Soft Torqueable catheter Optimized For Intracranial Access) intermediate and aspiration catheter for endovascular treatment of patients with acute ischemic stroke. METHODS: A retrospective review was performed in three centers of prospectively collected data of all stroke patients who underwent endovascular therapy using the SOFIA catheter. Patients were enrolled between November 2013 and December 2014. The primary endpoint of the study was accessibility of the thrombus with the SOFIA catheter. As a secondary endpoint, the study assessed recanalization success (Thrombolysis In Cerebral Infarction (TICI) ≥2b). Clinical presentation on admission and discharge was also documented. In addition, catheter- and procedure-related complications (particularly thromboembolic complications) were recorded. RESULTS: The SOFIA catheter was used in 115 acute stroke procedures. In 110 cases (96%) the catheter could be advanced to the occlusion site. After mechanical thrombectomy, successful recanalization (TICI ≥2b) was documented in 86.9%. There were no complications related to positioning of the catheter. Distal thrombus migration into a new vascular territory occurred in three patients following thrombectomy with a stent retriever (2.6%). The mean NIH Stroke Scale (NIHSS) score on admission was 16.8±6 and at discharge the mean NIHSS score was 8.2±7.7. Sixteen patients died. CONCLUSIONS: The SOFIA catheter is a safe and efficient catheter for endovascular stroke therapy.


Assuntos
Isquemia Encefálica/diagnóstico por imagem , Isquemia Encefálica/cirurgia , Catéteres , Segurança do Paciente , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos , Stents , Trombectomia/instrumentação , Trombectomia/métodos , Resultado do Tratamento , Adulto Jovem
15.
BJR Case Rep ; 2(1): 20150278, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-30364396

RESUMO

We present a patient who underwent successful removal of a fully detached platinum coil from the peroneal artery using a Solitaire™ stent retriever (Covidien, Irvine, CA) that is usually used in endovascular stroke treatment.

16.
BMC Sports Sci Med Rehabil ; 6(1): 4, 2014 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-24438692

RESUMO

BACKGROUND: During the 4,487 km ultra marathon TransEurope-FootRace 2009 (TEFR09), runners showed catabolism with considerable reduction of body weight as well as reversible brain volume reduction. We hypothesized that ultra marathon athletes might have developed changes to grey matter (GM) brain morphology due to the burden of extreme physical training. Using voxel-based morphometry (VBM) we undertook a cross sectional study and two longitudinal studies. METHODS: Prior to the start of the race 13 runners volunteered to participate in this study of planned brain scans before, twice during, and 8 months after the race. A group of matched controls was recruited for comparison. Twelve runners were able to participate in the scan before the start of the race and were taken into account for comparison with control persons. Because of drop-outs during the race, VBM could be performed in 10 runners covering the first 3 time points, and in 7 runners who also had the follow-up scan after 8 months. Volumetric 3D datasets were acquired using an MPRAGE sequence. A level of p < 0.05, family-wise corrected for multiple comparisons was the a priori set statistical threshold to infer significant effects from VBM. RESULTS: Baseline comparison of TEFR09 participants and controls revealed no significant differences regarding GM brain volume. During the race however, VBM revealed GM volume decreases in regionally distributed brain regions. These included the bilateral posterior temporal and occipitoparietal cortices as well as the anterior cingulate and caudate nucleus. After eight months, GM normalized. CONCLUSION: Contrary to our hypothesis, we did not observe significant differences between TEFR09 athletes and controls at baseline. If this missing difference is not due to small sample size, extreme physical training obviously does not chronically alter GM.However, during the race GM volume decreased in brain regions normally associated with visuospatial and language tasks. The reduction of the energy intensive default mode network as a means to conserve energy during catabolism is discussed. The changes were reversible after 8 months.Despite substantial changes to brain composition during the catabolic stress of an ultra marathon, the observed differences seem to be reversible and adaptive.

17.
BMC Med ; 10: 170, 2012 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-23259507

RESUMO

BACKGROUND: During the extremely challenging 4,487 km ultramarathon TransEurope-FootRace 2009, runners showed considerable reduction of body weight. The effects of this endurance run on brain volume changes but also possible formation of brain edema or new lesions were explored by repeated magnetic resonance imaging (MRI) studies. METHODS: A total of 15 runners signed an informed consent to participate in this study of planned brain scans before, twice during, and about 8 months after the race. Because of dropouts, global gray matter volume analysis could only be performed in ten runners covering three timepoints, and in seven runners who also had a follow-up scan. Scanning was performed on three identical 1.5 T Siemens MAGNETOM Avanto scanners, two of them located at our university. The third MRI scanner with identical sequence parameters was a mobile MRI unit escorting the runners. Volumetric 3D datasets were acquired using a magnetization prepared rapid acquisition gradient echo (MPRAGE) sequence. Additionally, diffusion-weighted (DWI) and fluid attenuated inversion recovery (FLAIR) imaging was performed. RESULTS: Average global gray matter volume as well as body weight significantly decreased by 6% during the race. After 8 months, gray matter volume returned to baseline as well as body weight. No new brain lesions were detected by DWI or FLAIR imaging. CONCLUSIONS: Physiological brain volume reduction during aging is less than 0.2% per year. Therefore a volume reduction of about 6% during the 2 months of extreme running appears to be substantial. The reconstitution in global volume measures after 8 months shows the process to be reversible. As possible mechanisms we discuss loss of protein, hypercortisolism and hyponatremia to account for both substantiality and reversibility of gray matter volume reductions. Reversible brain volume reduction during an ultramarathon suggests that extreme running might serve as a model to investigate possible mechanisms of transient brain volume changes. However, despite massive metabolic load, we found no new lesions in trained athletes participating in a multistage ultramarathon.See related commentary http://www.biomedcentral.com/1741-7015/10/171.


Assuntos
Encéfalo/anatomia & histologia , Corrida , Adulto , Idoso , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Estudos Prospectivos
18.
Acta Radiol ; 52(7): 738-42, 2011 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-21596797

RESUMO

BACKGROUND: Anatomical variants of the aortic arch and its branching patterns often appear as an incidental finding during routine computed tomography (CT) scanning. These variations can be of relevance when performing angiography or endovascular interventions and may cause symptoms such as dysphagia. PURPOSE: To analyze common anatomical variations found within the arteries originating from the aortic arch in patients using contrast CT imaging techniques. MATERIAL AND METHODS: A total of 2033 contrast CT scans were analyzed. To obtain a truly representative sample, cases were chosen from different hospital departments without previous knowledge of the patient history. RESULTS: The total percentage of variations within the analyzed patients was 13.3%. In 8.0% a truncus bicaroticus was found. 4.2% of the patients showed a left vertebral artery originating directly from the aortic arch, mostly proximal, and in 1 case distal to the left subclavian artery. In 1.0% we found an aberrant right subclavian artery. We also found a single case of a right descending aortic arch. CONCLUSION: Variations of the aortic arch and its branching are frequently found, mostly as an incidental finding during routine diagnostic scanning. A contrast-enhanced CT scan is a good method with which to study the aortic arch and its associated branching pattern.


Assuntos
Aorta Torácica/anormalidades , Aorta Torácica/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Meios de Contraste , Feminino , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
19.
J Nucl Med ; 47(8): 1335-41, 2006 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16883014

RESUMO

UNLABELLED: The outcome of hematopoietic cell transplantation for hematologic malignancies may be improved by delivering targeted radiation to hematopoietic organs while relatively sparing nontarget organs. We evaluated the biodistribution of 111In-labeled anti-CD45 antibody in humans using the rat IgG2a monoclonal antibody YAML568 that recognizes a common CD45 epitope present on all human leukocytes. METHODS: Eight patients undergoing bone marrow transplantation received YAML568 labeled with 122 +/- 16 MBq of 111In intravenously followed by serial blood sampling, urine collection, and conjugated view planar gamma-camera imaging up to 144 h after injection. Time-activity curves were obtained using region-of-interest analysis in the accumulating organs and residence times were calculated. An estimate for the radiation-absorbed doses for each organ per unit of administered activity of 90Y was calculated using software for internal dose assessment. The first patient received no unlabeled antibody preloading. The second 2 patients received a preloading dose of 10 mg (0.15 mg/kg). The last 5 patients received a preloading dose of 30-47 mg (0.5 mg/kg). RESULTS: No significant administration-related side effects were seen. The 3 patients receiving no antibody or low antibody preloading had an unfavorable biodistribution with a high initial accumulation of activity in the liver (37%) and the spleen (34%). For the patients receiving 0.5-mg/kg antibody preloading, the estimated radiation-absorbed doses for red bone marrow, spleen, liver, kidney, and total body were 6.4 +/- 1.2, 19 +/- 5, 3.9 +/- 1.4, 1.1 +/- 0.4, and 0.6 +/- 0.1 mGy/MBq, respectively, demonstrating preferential red marrow targeting. A linear regression model showed that the amount of unlabeled antibody preloading per body weight has a strong influence on the estimated red marrow absorbed dose (P = 0.003, R2 = 0.80). CONCLUSION: This study shows that the anti-CD45 monoclonal antibody YAML568 is suitable for delivering selectively radiation to hematopoietic tissues when labeled with 90Y provided that a preloading dose of about 0.5 mg/kg unlabeled antibody is given.


Assuntos
Anticorpos Monoclonais/química , Leucemia Mieloide Aguda/terapia , Antígenos Comuns de Leucócito/química , Leucemia-Linfoma Linfoblástico de Células Precursoras/terapia , Radioimunoterapia/métodos , Adulto , Idoso , Anticorpos Monoclonais/uso terapêutico , Transplante de Medula Óssea , Feminino , Humanos , Antígenos Comuns de Leucócito/biossíntese , Masculino , Pessoa de Meia-Idade , Transplante de Células-Tronco , Transplante Homólogo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA