Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
ACS Appl Bio Mater ; 7(1): 17-43, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38091514

RESUMO

3D bioprinting is recognized as a promising biomanufacturing technology that enables the reproducible and high-throughput production of tissues and organs through the deposition of different bioinks. Especially, bioinks based on loaded cells allow for immediate cellularity upon printing, providing opportunities for enhanced cell differentiation for organ manufacturing and regeneration. Thus, extensive applications have been found in the field of tissue engineering. The performance of the bioinks determines the functionality of the entire printed construct throughout the bioprinting process. It is generally expected that bioinks should support the encapsulated cells to achieve their respective cellular functions and withstand normal physiological pressure exerted on the printed constructs. The bioinks should also exhibit a suitable printability for precise deposition of the constructs. These characteristics are essential for the functional development of tissues and organs in bioprinting and are often achieved through the combination of different biomaterials. In this review, we have discussed the cutting-edge outstanding performance of different bioinks for printing various human tissues and organs in recent years. We have also examined the current status of 3D bioprinting and discussed its future prospects in relieving or curing human health problems.


Assuntos
Bioimpressão , Humanos , Impressão Tridimensional , Engenharia Tecidual , Materiais Biocompatíveis
2.
Langmuir ; 38(47): 14508-14516, 2022 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-36377419

RESUMO

Doubly re-entrant surfaces inspired by springtails exhibit excellent repellency to low-surface-tension liquid. However, the flexible doubly re-entrant surfaces are difficult to fabricate, especially for the overhang of the structure. Herein, we demonstrate a simple Fresnel aperture diffraction modulation strategy in microscale lithography coupled with a molding process to obtain the flexible doubly re-entrant superomniphobic surfaces with nanoscale overhangs. The negative nanoscale overhang features were formed in a single-layer photoresist due to the fine-modulation of the optical intensity fluctuation of the Fresnel aperture diffraction. The as-prepared flexible non-fluorinated polydimethylsiloxane (PDMS) doubly re-entrant microstructure based on the Fresnel aperture diffraction (D-BF) surface (without any additional treatments) could repel ethanol droplets (21.8 mN m-1) in the Cassie-Baxter state. The robust nanoscale overhangs obtained by the molding process enable the maximum breakthrough pressure for the low-surface-tension ethanol droplets on the D-BF surfaces up to about 230 Pa, allowing ethanol liquids with Weber numbers up to 8.7 to fully bounce off. The fabricated non-fluorinated D-BF superomniphobic surface maintains outstanding liquid repellency after the surface wettability modification and deformation test.

3.
ACS Appl Mater Interfaces ; 14(38): 43298-43307, 2022 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-36099528

RESUMO

Formamidinium (FA)-based perovskites remained state-of-the-art in the field of perovskite solar cells (PSCs) owing to the exceptional absorption and carrier transport properties, while the transition from photoactive (α-) to photoinactive (δ-FAPbI3) phase is the impediment that causes performance degradation and thus limits the deployment of FA-based PSCs. The unfavorable phase transition originates from tensile strain in the FAPbI3 crystal lattice, which undergoes structural reorganization for lattice strain balancing. In this work, we found that the ionic liquid (IL) could be used as the strain coordinator to balance the lattice strain for stability improvement of FAPbI3 perovskite. We theoretically studied the electronic coupling between IL and FAPbI3 and unraveled the originality of the IL-induced compressive strain. The strain-relaxed α-FAPbI3 by IL showed robust stability against environmental factors, which can withstand ambient aging for 40 days without any phase transition or decomposition. Moreover, the strain-relaxed perovskite films showed a lower trap density and resulted in conversion efficiency improvement from 18.27 to 19.88%. Based on this novel strain engineering strategy, the unencapsulated PSCs maintained 90% of their initial efficiency under ambient-air aging for 50 days.

4.
ACS Appl Mater Interfaces ; 14(34): 39665-39672, 2022 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-35983670

RESUMO

Flexible superomniphobic doubly re-entrant (Dual-T) microstructures inspired by springtails have attracted growing attention due to their excellent liquid-repellent properties. However, the simple and practical manufacturing processes of the flexible Dual-T microstructures are urgently needed. Here, we proposed a one-step molding process coupled with the lithography technique to fabricate the elastomeric polydimethylsiloxane (PDMS) Dual-T microstructure surfaces with high uniformity. The angle between the downward overhang and the horizontal direction could reach 90° (vertical overhang). The flexible superomniphobic Dual-T microstructure surfaces, without fluorination treatment and physical treatments, could repel liquids with a surface tension lower than 20 mN m-1 in the Cassie-Baxter state. Owing to the excellent robustness of the one-step molding downward overhanging, the max breakthrough pressure of this surface could reach up to 164.3 Pa for ethanol droplets. Furthermore, the flexible superomniphobic Dual-T surface allowed impinging ethanol droplets to completely rebound at the Weber number up to 7.1 with an impact velocity of ∼0.32 m s-1. The Dual-T microstructure surface maintained excellent superomniphobicity even after surface oxygen plasma treatment and exhibited excellent structural robustness and recoverability to various large mechanical deformations.

5.
Sensors (Basel) ; 20(22)2020 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-33233710

RESUMO

Hot film sensors detect the flow shear stress based on the forced convection heat transfer to the fluid. Current hot film sensors have been significantly hindered by the relatively low sensitivity due to the massive heat conduction to the substrate. This paper describes the design, fabrication, simulation, and testing of a novel flow sensor with dual-layer hot film structures. More specifically, the heat conduction was insulated from the sensing heater to the substrate by controlling both sensing and guarding heaters working at the same temperature, resulting in a higher sensitivity. The experiment and simulation results showed that the sensitivity of the dual-layer hot film sensor was significantly improved in comparison to the single-layer sensor. Additionally, the dual-layer sensor was designed and fabricated in an integrated, flexible, and miniaturized manner. Its small size makes it an excellent candidate for flow detection.

6.
Nanotechnology ; 31(47): 475601, 2020 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-32885792

RESUMO

The development of multi-role flexible thermal films embedded with single-walled carbon nanotubes (SWCNTs) exhibiting an adjustable temperature coefficient of resistance (TCR) is presented. The composite film is prepared by an alternating electric field to assembling CNTs on Ni conductive layer and polyimide. Modified vacuum thermal treatment is then conducted to adjust the TCR behavior of films, thereby gaining the positive, negative and near-zero TCR ranging from -1.5% °C-1 to nearly 1.0% °C-1 at different annealing conditions, respectively. The changes of morphologies, tube crystallinity and chemical elements in films are investigated. The enhanced intertube couplings in bundles of CNTs, formations of chemical bonds and recrystallization in heat-treated films, resulting in the change of charge transport, play a dominant role in the evolution of the TCR behavior. Heat-treated films also exhibit linear temperature dependence and high stability while operating at wide ambient temperature, leading to broad prospects in flexible electronic thermal applications.

7.
Sensors (Basel) ; 20(5)2020 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-32120933

RESUMO

Indium tin oxide (ITO) thin-film thermocouples monitor the temperature of hot section components in gas turbines. As an in situ measuring technology, the main challenge of a thin-film thermocouple is its installation on complex geometric surfaces. In this study, an ITO thin-film thermocouple probe based on a sapphire microrod was used to access narrow areas. The performance of the probe, i.e., the thermoelectricity and stability, was analyzed. This novel sensor resolves the installation difficulties of thin-film devices.

8.
Sensors (Basel) ; 18(10)2018 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-30326635

RESUMO

A flexible hot-film sensor array for wall shear stress, flow separation, and transition measurement has been fabricated and implemented in experiments. Parylene C waterproof layer is vapor phase deposited to encapsulate the sensor. Experimental studies of shear stress and flow transition on a flat plate have been undertaken in a water tunnel with the sensor array. Compared with the shear stress derived from velocity profile and empirical formulas, the measuring errors of the hot-film sensors are less than 5%. In addition, boundary layer transition of the flat plate has also been detected successfully. Ensemble-averaged mean, normalized root mean square, and power spectra of the sensor output voltage indicate that the Reynolds number when transition begins at where the sensor array located is 1.82 × 105, 50% intermittency transition is 2.52 × 105, and transition finishes is 3.96 × 105. These results have a good agreement with the transition Reynolds numbers, as measured by the Laser Doppler Velocimetry (LDV) system.

9.
Sensors (Basel) ; 18(8)2018 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-30111724

RESUMO

A micro-floating element wall shear stress sensor with backside connections has been developed for accurate measurements of wall shear stress under the turbulent boundary layer. The micro-sensor was designed and fabricated on a 10.16 cm SOI (Silicon on Insulator) wafer by MEMS (Micro-Electro-Mechanical System) processing technology. Then, it was calibrated by a wind tunnel setup over a range of 0 Pa to 65 Pa. The measurements of wall shear stress on a smooth plate were carried out in a 0.6 m × 0.6 m transonic wind tunnel. Flow speed ranges from 0.4 Ma to 0.8 Ma, with a corresponding Reynold number of 1.05 × 106~1.55 × 106 at the micro-sensor location. Wall shear stress measured by the micro-sensor has a range of about 34 Pa to 93 Pa, which is consistent with theoretical values. For comparisons, a Preston tube was also used to measure wall shear stress at the same time. The results show that wall shear stress obtained by three methods (the micro-sensor, a Preston tube, and theoretical results) are well agreed with each other.

10.
Sensors (Basel) ; 17(10)2017 Oct 22.
Artigo em Inglês | MEDLINE | ID: mdl-29065498

RESUMO

A new variant of MEMS surface fence is proposed for shear-stress estimation under high-speed, high-temperature flow conditions. Investigation of high-temperature resistance including heat-resistant mechanism and process, in conjunction with high-temperature packaging design, enable the sensor to be used in environment up to 400 °C. The packaged sensor is calibrated over a range of ~65 Pa and then used to examine the development of the transient flow of the scramjet ignition process (Mach 2 airflow, stagnation pressure, and a temperature of 0.8 MPa and 950 K, respectively). The results show that the sensor is able to detect the transient flow conditions of the scramjet ignition process including shock impact, flow correction, steady state, and hydrogen off.

11.
J Biomed Mater Res B Appl Biomater ; 103(7): 1375-80, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25389043

RESUMO

Control of cell adhesion and growth by microfabrication technology and surface chemistry is important in an increasing number of applications in biotechnology and medicine. In this study, we developed a method to fabricate (2-hydroxyethyl methacrylate) (polyHEMA) grids on glass by micromolding in capillaries (MIMIC). As a non-fouling biomaterial, polyHEMA was used to inhibit the nonspecific bonding of cells, whereas the glass surface provided a cell adhesive background. The polyHEMA chemical barrier was directly obtained using MIMIC without surface modification, and the microchannel networks used for capillarity were easily achieved by reversibly bonding the polydimethylsiloxane (PDMS)mold and the glass. After fabrication of the polyHEMA micropattern, individual cytophilic microwells surrounded by cytophobic sidewalls were presented on the glass surface. The polyHEMA micropattern proved effective in controlling the shape and spreading of cells, and square-shaped mouse osteoblast MC3T3-E1 cells were obtained in microwell arrays after incubation for 3 days. Moreover, the widths of the microwells in this micropattern were optimized for use as single-cell arrays. The proposed method could be a convenient tool in the field of drug screening, stem cell research, and tissue engineering.


Assuntos
Análise em Microsséries/instrumentação , Análise em Microsséries/métodos , Osteoblastos/metabolismo , Poli-Hidroxietil Metacrilato/química , Animais , Linhagem Celular , Avaliação Pré-Clínica de Medicamentos/instrumentação , Avaliação Pré-Clínica de Medicamentos/métodos , Camundongos , Osteoblastos/citologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA