Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Plant Cell Environ ; 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38747469

RESUMO

Drought, as a primary environmental factor, imposes significant constraints on developmental processes and productivity of plants. PHDs were identified as stress-responsive genes in a wide range of eukaryotes. However, the regulatory mechanisms governing PHD genes in maize under abiotic stress conditions are still largely unknown and require further investigation. Here, we identified a mutant, zmvil2, in the EMS mutant library with a C to T mutation in the exon of the Zm00001d053875 (VIN3-like protein 2, ZmVIL2), resulting in premature termination of protein coding. ZmVIL2 belongs to PHD protein family. Compared to WT, zmvil2 mutant exhibited increased sensitivity to drought stress. Consistently, overexpression of ZmVIL2 enhances drought resistance in maize. Y2H, BiFC, and Co-IP experiments revealed that ZmVIL2 directly interacts with ZmFIP37 (FKBP12-interacting protein of 37). zmfip37 knockout mutants also exhibit decreased drought tolerance. Interestingly, we demonstrated that ZmABF4 directly binds to the ZmVIL2 promoter to enhance its activity in yeast one hybrid (Y1H), electrophoretic mobility shift assay (EMSA) and dual luciferase reporter assays. Therefore, we uncovered a novel model ZmABF4-ZmVIL2/ZmFIP37 that promotes drought tolerance in maize. Overall, these findings have enriched the knowledge of the functions of PHD genes in maize and provides genetic resources for breeding stress-tolerant maize varieties.

2.
Food Chem ; 448: 139210, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38569408

RESUMO

The detection of heavy metals in tea infusions is important because of the potential health risks associated with their consumption. Existing highly sensitive detection methods pose challenges because they are complicated and time-consuming. In this study, we developed an innovative and simple method using Ag nanoparticles-modified resin (AgNPs-MR) for pre-enrichment prior to laser-induced breakdown spectroscopy for the simultaneous analysis of Cr (III), Cu (II), and Pb (II) in tea infusions. Signal enhancement using AgNPs-MR resulted in amplification with limits of detection of 0.22 µg L-1 for Cr (III), 0.33 µg L-1 for Cu (II), and 1.25 µg L-1 for Pb (II). Quantitative analyses of these ions in infusions of black tea from various brands yielded recoveries ranging from 83.3% to 114.5%. This method is effective as a direct and highly sensitive technique for precisely quantifying trace concentrations of heavy metals in tea infusions.


Assuntos
Cromo , Cobre , Contaminação de Alimentos , Chumbo , Nanopartículas Metálicas , Prata , Chá , Chá/química , Cromo/análise , Chumbo/análise , Prata/química , Nanopartículas Metálicas/química , Cobre/análise , Contaminação de Alimentos/análise , Análise Espectral/métodos , Lasers , Camellia sinensis/química , Metais Pesados/análise , Limite de Detecção
3.
CNS Neurosci Ther ; 30(2): e14614, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38358062

RESUMO

BACKGROUND: Transcutaneous auricular vagus nerve stimulation (taVNS) is a crucial neuromodulation therapy for depression, yet its molecular mechanism remains unclear. Here, we aim to unveil the underlying mechanisms of antidepression by systematically evaluating the change of gene expression in different brain regions (i.e., hippocampus, anterior cingulate cortex, and medial prefrontal cortex). METHODS: The adolescent depression rat model was established by chronic unpredictable mild stress (CUMS), followed by the taVNS treatment for 3 weeks. The open field test (OFT), forced swimming test (FST), elevated plus maze test (EPM), and new object recognition (NOR) test were used to evaluate depressive- and anxiety-like behaviors. Gene expression analysis of three brain regions was conducted by RNA sequencing (RNA-seq) and further bioinformatics methods. RESULTS: The depressive- and anxiety-like behaviors in CUMS-exposed rats were manifested by decreased spontaneous locomotor activity of OFT, increased immobility time of FST, increased entries and time in the closed arms of EPM, and decreased new object index of NOR. Furthermore, CUMS exposure also led to alterations in gene expression within the hippocampus (HIP), anterior cingulate cortex (ACC), and medial prefrontal cortex (mPFC), suggesting a potential link between adolescent stress and pathological changes within these brain regions. TaVNS could significantly ameliorate depressive- and anxiety-like behaviors. Its effects on these three brain regions were found related to regulation of the metabolism, and there were some brain region-specific findings. Compared with ACC and mPFC, taVNS has a more concrete effect on HIP by regulating the inflammation response and glycolysis. CONCLUSION: taVNS is capable of ameliorating adolescent depressive- and anxiety-like behaviors by regulating plenty of genes in the three brain regions. Suppressed level of inflammatory response and enhanced glycolysis manifests the dominant role of taVNS in HIP, which provides a theoretical foundation and data support for the molecular mechanism of antidepression by taVNS.


Assuntos
Estimulação do Nervo Vago , Ratos , Animais , Encéfalo , Hipocampo/metabolismo , Ansiedade/terapia , Nervo Vago , Inflamação/terapia , Inflamação/metabolismo
4.
Plant Biotechnol J ; 22(4): 929-945, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38009862

RESUMO

The control of flowering time in maize is crucial for reproductive success and yield, and it can be influenced by environmental stresses. Using the approaches of Ac/Ds transposon and transposable element amplicon sequencing techniques, we identified a Ds insertion mutant in the ZmPRR37 gene. The Ds insertion showed a significant correlation with days to anthesis. Further research indicated that ZmPRR37-CR knockout mutants exhibited early flowering, whereas ZmPRR37-overexpression lines displayed delayed flowering compared to WT under long-day (LD) conditions. We demonstrated that ZmPRR37 repressed the expression of ZmNF-YC2 and ZmNF-YA3 to delay flowering. Association analysis revealed a significant correlation between flowering time and a SNP2071-C/T located upstream of ZmPRR37. The SNP2071-C/T impacted the binding capacity of ZmELF6 to the promoter of ZmPRR37. ZmELF6 also acted as a flowering suppressor in maize under LD conditions. Notably, our study unveiled that ZmPRR37 can enhance salt stress tolerance in maize by directly regulating the expression of ABA-responsive gene ZmDhn1. ZmDhn1 negatively regulated maize salt stress resistance. In summary, our findings proposed a novel pathway for regulating photoperiodic flowering and responding to salt stress based on ZmPRR37 in maize, providing novel insights into the integration of abiotic stress signals into floral pathways.


Assuntos
Flores , Proteínas de Plantas , Proteínas de Plantas/genética , Proteínas de Plantas/metabolismo , Flores/fisiologia , Zea mays/genética , Zea mays/metabolismo , Fotoperíodo , Regiões Promotoras Genéticas , Regulação da Expressão Gênica de Plantas/genética
5.
J Hazard Mater ; 443(Pt A): 130188, 2023 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-36265387

RESUMO

The rapid and sensitive detection of heavy metal ions is important for environment and human health. Hence, the rapid and sensitive detection of multiple heavy metals simultaneously has become a critical issue. Here, we propose a method based on laser-induced breakdown spectroscopy (LIBS) combined with filter paper modified with PtAg bimetallic nanoparticles (BNPs) (LIBS-FP-PtAgBNPs) for the ultrasensitive detection of Hg2+, Cr3+, and Pb2+. The PtAgBNPs-modified filter paper was used to efficiently and specifically adsorb Hg, Cr, and Pb, and LIBS was used to detect the Hg, Cr, and Pb simultaneously. The limits of detection for Hg, Cr, and Pb were 0.5 µg/L (2.5 nM), 8 µg/L (0.15 µM), and 2 µg/L (9 nM), respectively. Furthermore, this method was successfully applied to determine the concentrations of Hg, Cr, and Pb in real spiked water samples. Compared with other methods based on nanoparticle sensing, LIBS-FP-PtAgBNPs is simpler to use and can achieve highly efficient enrichment, rapid separation, and sensitive detection of heavy metal ions. The optimal detections of Hg, Cr, and Pb were achieved in the pH range of 1-6. The developed method provides a new avenue to realize the rapid and sensitive detection of trace heavy metals in the environment.


Assuntos
Mercúrio , Metais Pesados , Nanopartículas , Humanos , Chumbo , Análise Espectral/métodos , Íons , Lasers
6.
Cell Commun Signal ; 20(1): 128, 2022 08 25.
Artigo em Inglês | MEDLINE | ID: mdl-36008839

RESUMO

BACKGROUND: Retroperitoneal liposarcoma (RPLS) is a specific soft tissue sarcoma with a high recurrence rate. The short isoform of transient receptor potential cation channel subfamily M member 2 (TRPM2-S) plays an important role in the regulation of reactive oxygen species (ROS). However, the association between TRPM2-S and RPLS and its underlying mechanisms remains unclear. METHODS: The expression of both TRPM2-S and TRPM2-L in RPLS tissues was verified by kimmunohistochemistry (IHC). The regulation on Ca2+ influx by TRPM2-S was evaluated by Fluo-4 AM staining. The effect of TRPM2-S on cell proliferation and apoptosis was tested by 5-Ethynyl-2'-deoxyuridine (EdU) staining and Flow cytometry respectively. The level of cellular ROS was assessed by the DCFH-DA probe. Different concentrations of H2O2 were used to provide oxidative stress on RPLS cells. The underlying mechanisms were further explored by Western blotting. RESULTS: The IHC assays showed that TRPM2-S, but not TRPM2-L, was prognostic in RPLS. Low TRPM2-S level was associated with poor disease-free survival (DFS). Calcium influx signal intensity was significantly decreased under TRPM2-S overexpression, which resulted in a decrease in the levels of FOXO3a and PTEN. Correspondingly, the levels of pERK, pAKT, pP65, pGSK-3ß, Bcl-2, and ß-catenin were upregulated, and cellular ROS was gently increased under TRPM2-S overexpression. Moreover, TRPM2-S slightly promoted cell proliferation and inhibited apoptosis of RPLS cell lines under normoxia, but largely increased apoptosis rates under oxidative stress. The cleaved caspase3 was significantly upregulated by TRPM2-S overexpression under oxidative stress. N-Acetyl-L-cysteine (NAC), a small molecule antioxidant, could largely rescue RPLS cells from the apoptosis induced by H2O2. CONCLUSION: TRPM2-S exerts Janus-faced effects in RPLS by increasing the ROS levels via inhibition on FOXO3a, which promotes cell proliferation under normoxia but induces apoptosis under oxidative stress. Video abstract.


Assuntos
Canais de Cátion TRPM , Apoptose , Cálcio/metabolismo , Peróxido de Hidrogênio/metabolismo , Peróxido de Hidrogênio/farmacologia , Lipossarcoma , Estresse Oxidativo , Espécies Reativas de Oxigênio/metabolismo , Neoplasias Retroperitoneais
7.
Appl Opt ; 59(30): 9591-9597, 2020 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-33104681

RESUMO

Laser opto-ultrasonic dual (LOUD) detection, which uses laser irradiation of samples to generate spectral and ultrasonic signals simultaneously, can perform multimodal detection of element composition and structural property. As such, it has been applied to the detection of additive manufacturing (AM) components. Further, optimized parameters lead to better detection results. To the best of our knowledge, however, there is no study on the effect of laser properties on LOUD detection. Therefore, we studied the mechanism and influence of laser wavelength and energy on LOUD detection. In this work, the intensity, signal-to-noise ratio (SNR), and stability evolution of the laser excitation spectrum and ultrasonic signals at different wavelengths and energies were analyzed. It was found in the plasma evolution that high electron number density means a large amount of ablated mass generated, which was favorable for laser ultrasonic excitation and can produce higher SNR and a more stable signal. However, it also led to more atoms of the ground-state, which resulted in the self-absorption effect and reduced spectrum intensity in the spectrum analysis. Therefore, with self-absorption correction, better stability, and higher signal intensity, an SNR of spectral and ultrasonic signals can be obtained using 355 nm laser excitation at optimal energy. As a result, in the quantitative analysis of Cu and Si elements by LOUD detection, the determination coefficients (R2) were higher than 0.995, and the average relative errors were less than 2.5%, the limit of detection could reach the order of 100 ppm. Further, the defect size of 0.55 mm in the wire +arc additive manufacturing sample was detected by LOUD detection, and the average relative error was 5.59% compared with the digital radiography results, which indicate that laser wavelength and laser energy affect the intensity and stability of spectral and ultrasonic signals in LOUD detection, which means selecting appropriate laser parameters is important to obtain a high precision detection.

8.
Materials (Basel) ; 13(10)2020 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-32456159

RESUMO

Metal-based additive manufacturing (AM) is a disruptive technique with great potential across multiple industries; however, its manufacturing quality is unstable, leading to an urgent requirement for component properties detection. The distribution of grain size has an important effect on many mechanical properties in AM, while the distribution of added elements, such as titanium (Ti), has a measurable effect on the grain size of an aluminum (Al) alloy. Therefore, the detection of the distributions of grain size and elements is of great significance for AM. In this study, we investigated the distribution of grain size and elements simultaneously for wire + arc additive manufacturing (WAAM) with an Al alloy using laser opto-ultrasonic dual (LOUD) detection. The average grain size obtained from the acoustic attenuation of ultrasonic signals was consistent with the results of electron backscatter diffraction (EBSD), with a coefficient of determination (R2) of 0.981 for linear fitting. The Ti element distribution obtained from optical spectra showed that the enrichment of Ti corresponded to the grain refinement area in the detected area. The X-ray diffraction (XRD) spectra showed that the spectral peaks were moved from Al to AlTi and Al2Ti forms in the Ti-rich areas, which confirmed the LOUD results. The results indicated that LOUD detection holds promise for becoming an effective method of analyzing the mechanical and chemical properties of components simultaneously, which could help explain the complex physical and chemical changes in AM and ultimately improve the manufacturing quality.

9.
Talanta ; 214: 120849, 2020 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-32278424

RESUMO

The detection sensitivity of chlorine (Cl) and sulfur (S) elements is poor using direct laser-induced breakdown spectroscopy (LIBS) because of the high ionization energy of Cl and S. Therefore, a new technique, namely indirect laser-induced breakdown spectroscopy (ID-LIBS), was proposed to improve the detection sensitivity of Cl and S elements. The method detected Cl in water by indirectly detecting the excess silver (Ag) after the precipitation reaction of Ag and chloride. Similarly, the method indirectly detected S in water by detecting the excess barium (Ba) after the precipitation reaction of Ba and sulfate, due to Ag and Ba with low ionization energy and easy excitation. The lines of Ag I 546.5 nm and Ba I 553.5 nm were detected. The R2 values of 0.999 and 0.997 were obtained for Cl and S, respectively. The limit of quantitation (LoQ) was 2 mg/L for Cl and 5 mg/L for S. The detection sensitivity was improved by about three orders of magnitude compared to using Cl I 822.17 nm and S I 921.28 nm. The results showed that the technique of indirect LIBS can achieve the sensitive detection of Cl and S in water indicating that the technique has tremendous potential for element analysis of water.

10.
Anal Chim Acta ; 1107: 14-22, 2020 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-32200888

RESUMO

The matrix effect is one of the main bottlenecks for the laser-induced breakdown spectroscopy (LIBS) technique. In this work, image-assisted, laser-induced breakdown spectroscopy (IA-LIBS) based on the Lomakin-Scherbe formula was put forward as a correction to the matrix effect. The brightness and area information in the plasma image was extracted to correct the spectral line intensities among which the brightness information characterizes the plasma temperature, and the area information characterizes the ablative mass. To verify the feasibility of this method, the experiment was conducted on metal samples and pressed samples. The method was applied for quantitative analysis of copper (Cu), magnesium (Mg) in metal samples and chromium (Cr), manganese (Mn) in pressed samples. For the metal samples, after correcting the matrix effect by IA-LIBS, the determination coefficient R squared (R2) of Cu I 510.55 nm and Mg I 518.36 nm calibration curves were increased from 0.726 to 0.942 to 0.992 and 0.988, respectively. The root-mean-square-error of cross-validation (RMSECV) and the average relative error (ARE) decreased by 75.10% and 77.18%, respectively. For the pressed samples, R2 of Cr I 520.84 nm and Mn I 403.07 nm calibration curves corrected by IA-LIBS increased from 0.364 to 0.098 to 0.975 and 0.980; and RMSECV and ARE decreased by 77.88% and 83.83%, respectively. The experimental results showed that IA-LIBS had an obvious improvement on elimination of the matrix effect for the different samples and the different elements. Therefore, IA-LIBS will become a promising technology and will greatly promote the development of LIBS in various fields.

11.
Opt Express ; 27(10): 15091-15099, 2019 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-31163946

RESUMO

Heavy metal pollution is one of the main problems in water pollution, which is harmful to humans. Surface-enhanced laser-induced breakdown spectroscopy (SENLIBS) has been applied to detect trace amounts of heavy metal elements in aqueous solution; however, it is still a big challenge to explore the relationship between the LIBS detection sensitivity and the substrate's physical properties. In this work, four typical substrates, zinc (Zn), magnesium alloy (Mg), nickel (Ni), and silicon (Si), were compared; and the mechanism of spectral enhancement by different substrates in SENLIBS was investigated. The results indicated that the limit of detection (LoD) of heavy metal elements on different substrates is positively proportional to the boiling of the substrate. That is mainly because a higher plasma excitation temperature and electron density are obtained, leading to more intense collision between particles. The signal enhancement is associated with the lower boiling point of the substrate (corresponding to a lower ablation threshold and higher ablation quantity from the substrate). As a result, the best LoD was 0.0011 mg/L for chromium (Cr) and 0.004 mg/L for lead (Pb) on an optimal Zn substrate, respectively. The LoDs were sufficiently low to meet the drinking water sanitation standard. These results showed that the detection sensitivity of heavy metal elements in aqueous solution can be improved by choosing a substrate with a lower boiling point in SENLIBS.

12.
J Sci Food Agric ; 99(12): 5558-5564, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31150114

RESUMO

BACKGROUND: Rice adulteration in the food industry that infringes on the interests of consumers is considered very serious. To realize the rapid and precise quantitation of adulterated rice, a visible near infrared (VNIR) hyperspectral imaging system (380-1000 nm) was developed in the present study. A Savitsky-Golay first derivative (SG1) transform was utilized to eliminate the constant spectral baseline offset. Then, the adulterated levels of rice samples were quantified by partial least squares regression (PLSR). RESULTS: A SG1-PLSR model based on full-wavelength was attained with a coefficient of determination of prediction set (RP ) of 0.9909, root-mean-square error of prediction set (RMSEP ) of 0.0447 g kg-1 and residual predictive deviation (RPDP ) of 11.28. Furthermore, fifteen important wavelengths were selected based on the weighted regression coefficients (BW ) and a simplified model (PLSR-15) was established with RP of 0.9769, RMSEP of 0.0708 g kg-1 and RPDP of 3.49. Finally, two visualization maps produced by applying the optimal models (SG1-PLSR and PLSR-15) were used to visualize the adulterated levels of rice. CONCLUSION: These results demonstrate that VNIR hyperspectral imaging system is an effective tool for rapidly quantifying and visualizing the adulterated levels of rice. © 2019 Society of Chemical Industry.


Assuntos
Oryza/química , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Contaminação de Alimentos/análise , Análise dos Mínimos Quadrados
13.
Opt Express ; 27(4): 4261-4270, 2019 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-30876043

RESUMO

Self-absorption seriously affects the accuracy and stability of quantitative analysis in laser-induced breakdown spectroscopy (LIBS). To reduce the effect of self-absorption, we investigated the temporal evolution of the self-absorption effect by establishing exponential calibration curves. Meanwhile, the temporal evolution mechanism of the self-absorption effect was also investigated. The results indicated that self-absorption was weak at the early stage of plasma expansion. For determination of manganese (Mn) in steel, as an example, the concentration of upper bound of linearity (Cint) was 2.000 wt. % at the early stage of plasma expansion (in a time window of 0.2-0.4 µs)-much higher than 0.363 wt. % at a traditional optimization time window (2-3 µs). The accuracy and stability of quantitative analysis at the time window of 0.2-0.4 µs was also much better than at the time window of 2-3 µs. This work provides a simple method for improving quantitative analysis performance and avoiding the self-absorption effect in LIBS.

14.
Appl Opt ; 57(30): 8942-8946, 2018 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-30461880

RESUMO

Antimony (Sb) in soil is attracting attention in the research community due to its potential toxicity and carcinogenicity. Traditional methods of detecting Sb lack the ability of rapid and nondigestion analysis, which hinders their development and application. Moreover, it is still a challenge for laser-induced breakdown spectroscopy (LIBS) to detect Sb in soil due to the weak intensities and intense interference of spectral lines. Here, LIBS, assisted with laser-induced fluorescence (LIBS-LIF), was used to selectively enhance the Sb's characteristic spectral lines under optimal parameters. The quantitative analysis performance was notably improved with a determination coefficient (R2) of 0.991, the limit of detection of 0.221 µg/g, and root mean square error of cross validation of 3.592 µg/g. These results demonstrate that LIBS-LIF has the potential to realize the rapid and accurate analysis of Sb in soil.

15.
Opt Express ; 26(23): 30409-30419, 2018 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-30469915

RESUMO

Fiber-optic laser-induced breakdown spectroscopy (FO-LIBS) has been employed in many applications because of the flexibility of optical fiber cable. However, the inhomogeneous elemental distribution of plasmas can cause a self-absorption effect and, hence, significantly hinder the determination of FO-LIBS. Here, to solve this flaw, we took iron (Fe), magnesium (Mg), and zinc (Zn) elements in aluminum alloy as examples to investigate the self-absorption reduction and accuracy improvement using spatially resolved FO-LIBS. Spatially resolved FO-LIBS means the spectra were collected at different positions along the direction parallel to the surface of the sample rather than at the center of the plasma. With this method, the self-absorption effect could be improved by selecting different acquisition positions along the X-axis. The root mean square error of cross-validations (RMSECV) for Fe, Mg, and Zn were reduced from 0.388, 0.348, and 0.097 wt. % to 0.172, 0.224, and 0.024 wt. %, respectively. Generally, spatial resolution is an effective method of self-absorption reduction and accuracy improvement in FO-LIBS.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA