Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Arthritis Rheumatol ; 75(4): 630-638, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36122187

RESUMO

OBJECTIVE: To assess the reliability and diagnostic accuracy of new radiographic imaging definitions developed by an international multidisciplinary working group for identification of calcium pyrophosphate deposition (CPPD). METHODS: Patients with knee osteoarthritis scheduled for knee replacement were enrolled. Two radiologists and 2 rheumatologists twice assessed radiographic images for presence or absence of CPPD in menisci, hyaline cartilage, tendons, joint capsule, or synovial membrane, using the new definitions. In case of disagreement, a consensus decision was made and considered for the assessment of diagnostic performance. Histologic examination of postsurgical specimens under compensated polarized light microscopy was the reference standard. Prevalence-adjusted bias-adjusted kappa values were used to assess reliability, and diagnostic performance statistics were calculated. RESULTS: Sixty-seven patients were enrolled for the reliability study. The interobserver reliability was substantial in most of the assessed structures when considering all 4 readers (κ range 0.59-0.90), substantial to almost perfect among radiologists (κ range 0.70-0.91), and moderate to almost perfect among rheumatologists (κ range 0.46-0.88). The intraobserver reliability was substantial to almost perfect for all the observers (κ range 0.70-1). Fifty-one patients were included in the accuracy study. Radiography demonstrated an overall specificity of 92% for CPPD, but sensitivity remained low for all sites and for the overall diagnosis (54%). CONCLUSION: The new radiographic definitions of CPPD are highly specific against the gold standard of histologic diagnosis. When the described radiographic findings are present, these definitions allow for a definitive diagnosis of CPPD, rather than other calcium-containing crystal depositions; however, a negative radiographic finding does not exclude the diagnosis.


Assuntos
Calcinose , Condrocalcinose , Humanos , Pirofosfato de Cálcio , Condrocalcinose/diagnóstico por imagem , Reprodutibilidade dos Testes , Articulação do Joelho/diagnóstico por imagem , Radiografia
2.
Lancet Rheumatol ; 5(8): e474-e482, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38251579

RESUMO

BACKGROUND: The Calcium Pyrophosphate Deposition (CPPD) subgroup of the Outcome Measures in Rheumatology (OMERACT) Ultrasound working group was established to validate ultrasound as an outcome measure instrument for CPPD, and in 2017 has developed and validated standardised definitions for elementary lesions for the detection of calcium pyrophosphate crystals in joints. The aim of this study was to develop and evaluate the reliability of a consensus-based ultrasound scoring system for CPPD extent, representing the next phase in the OMERACT methodology. METHODS: In this study the novel scoring system for CPPD was developed through a stepwise process, following an established OMERACT ultrasound methodology. Following a previous systematic review to gather available evidence on existing scoring systems for CPPD, the novel scoring system was developed through a Delphi survey based on the expert opinion of the members of the OMERACT Ultrasound working group-CPPD subgroup. The reliability of the scoring system was then tested on a web-based and patient-based exercise. Intra-reader and inter-reader reliability of the new scoring system was assessed using weighted Light's κ coefficients. FINDINGS: The four-grade semiquantitative scoring system consisted of: grade 0 (no findings consistent with CPPD), grade 1 (≤3 single spots or 1 small deposit), grade 2 (>3 single spots or >1 small deposit or ≥1 larger deposit occupying ≤50% of the structure under examination in the reference image-ie, the scanning view with the highest grade of depositions), and grade 3 (deposits that occupy more than 50% of the structure under examination in the reference image). The score should be applied to the knee (menisci and hyaline cartilage) and the triangular fibrocartilage complex of the wrist. The intra-reader and inter-reader reliabilities on static images were almost perfect (κ 0·90 [95% CI 0·79-1·00] and κ 0·84 [0·79-0·88]), and on the eight patients recruited (four [50%] female and four [50%] male) were substantial (κ 0·72 [95% CI 0·47 to 0·96] and 0·66 [0·61 to 0·71]). INTERPRETATION: This OMERACT ultrasound scoring system for CPPD was reliable on both static images and patients. The scoring system might be a valuable tool for ensuring valid and comparable results in clinical trials and could help monitor the extent of crystal deposition in patients with CPPD in clinical practice. FUNDING: The Italian Ministry of Health - Ricerca Corrente.


Assuntos
Calcinose , Pirofosfato de Cálcio , Humanos , Feminino , Masculino , Reprodutibilidade dos Testes , Difosfatos , Ultrassonografia
3.
Rheumatology (Oxford) ; 61(8): 3341-3350, 2022 08 03.
Artigo em Inglês | MEDLINE | ID: mdl-34849616

RESUMO

OBJECTIVE: The aim of this exercise from the OMERACT Ultrasound subgroup on Sjögren's syndrome was to develop and assess the reliability of a consensus-based semiquantitative colour Doppler US scoring system for pathologic salivary gland vascularization in patients with primary Sjögren's syndrome (pSS). METHODS: Using the Delphi method, a colour Doppler semiquantitative scoring system for vascularization of bilateral parotid and submandibular glands was developed and tested in static images and on patients (9 pSS patients and 9 sonographers). Intra-reader and inter-reader reliability of grading the salivary glands were computed by weighted Cohen and Light's kappa analysis, respectively. RESULTS: The consensus-based semiquantitative score was: grade 0, no visible vascular signals; grade 1, focal, dispersed vascular signals; grade 2, diffuse vascular signals detected in <50% of the gland; grade 3, diffuse vascular signals in >50% of the gland. In static images, the intra- and inter-reader reliability showed excellent kappa values (95% CI) of 0.90 (0.87, 0.93) and 0.80 (0.74, 0.84), respectively, for all four salivary glands together. In patients, the intra- and inter-reader reliability for all four salivary glands together was kappa = 0.84 (0.73, 0.92) and 0.70 (0.64, 0.76), respectively. CONCLUSION: The consensus-based colour Doppler US scoring for the evaluation of salivary gland vascularization in pSS showed a good inter-reader reliability and excellent intra-reader reliability in static images and in patients. The clinical application of the developed scoring system should be tested in clinical settings.


Assuntos
Síndrome de Sjogren , Humanos , Inflamação/patologia , Reprodutibilidade dos Testes , Glândulas Salivares/diagnóstico por imagem , Glândulas Salivares/patologia , Síndrome de Sjogren/diagnóstico por imagem , Síndrome de Sjogren/patologia , Glândula Submandibular/diagnóstico por imagem , Ultrassonografia/métodos
4.
Ann Rheum Dis ; 80(2): 261-267, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32988839

RESUMO

OBJECTIVE: To evaluate the discriminatory ability of ultrasound in calcium pyrophosphate deposition disease (CPPD), using microscopic analysis of menisci and knee hyaline cartilage (HC) as reference standard. METHODS: Consecutive patients scheduled for knee replacement surgery, due to osteoarthritis (OA), were enrolled. Each patient underwent ultrasound examination of the menisci and HC of the knee, scoring each site for presence/absence of CPPD. Ultrasound signs of inflammation (effusion, synovial proliferation and power Doppler) were assessed semiquantitatively (0-3). The menisci and condyles, retrieved during surgery, were examined microscopically by optical light microscopy and by compensated polarised microscopy. CPPs were scored as present/absent in six different samples from the surface and from the internal part of menisci and cartilage. Ultrasound and microscopic analysis were performed by different operators, blinded to each other's findings. RESULTS: 11 researchers from seven countries participated in the study. Of 101 enrolled patients, 68 were included in the analysis. In 38 patients, the surgical specimens were insufficient. The overall diagnostic accuracy of ultrasound for CPPD was of 75%-sensitivity of 91% (range 71%-87% in single sites) and specificity of 59% (range 68%-92%). The best sensitivity and specificity were obtained by assessing in combination by ultrasound the medial meniscus and the medial condyle HC (88% and 76%, respectively). No differences were found between patients with and without CPPD regarding ultrasound signs of inflammation. CONCLUSION: Ultrasound demonstrated to be an accurate tool for discriminating CPPD. No differences were found between patents with OA alone and CPPD plus OA regarding inflammation.


Assuntos
Condrocalcinose/diagnóstico por imagem , Cartilagem Hialina/diagnóstico por imagem , Menisco/diagnóstico por imagem , Osteoartrite do Joelho/diagnóstico por imagem , Ultrassonografia/estatística & dados numéricos , Idoso , Artroplastia do Joelho , Pirofosfato de Cálcio/análise , Feminino , Humanos , Cartilagem Hialina/patologia , Masculino , Menisco/patologia , Microscopia/métodos , Microscopia/estatística & dados numéricos , Pessoa de Meia-Idade , Osteoartrite do Joelho/patologia , Osteoartrite do Joelho/cirurgia , Período Pré-Operatório , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Ann Rheum Dis ; 78(7): 967-973, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31036626

RESUMO

OBJECTIVE: To develop ultrasound (US) definitions and a US novel scoring system for major salivary gland (SG) lesions in patients with primary Sjögren's syndrome (pSS) and to test their intrareader and inter-reader reliability using US video clips. METHODS: Twenty-five rheumatologists were subjected to a three-round, web-based Delphi process in order to agree on (1) definitions and scanning procedure of salivary gland ultrasonography (SGUS): parotid, submandibular and sublingual glands (PG, SMG and SLG); (2) definitions for the elementary SGUS lesions in patients with Sjögren's syndrome; (3) scoring system for grading changes. The experts rated the statements on a 1-5 Likert scale. In the second step, SGUS video clips of patients with pSS and non-pSS sicca cases were collected containing various spectrums of disease severity followed by an intrareader and inter-reader reliability exercise. Each video clip was evaluated according to the agreed definitions. RESULTS: Consensual definitions were developed after three Delphi rounds. Among the three selected SGs, US assessment of PGs and SMGs was agreed on. Agreement was reached to score only greyscale lesions and to focus on anechoic/hypoechoic foci in a semiquantitative matter or, if not possible on a qualitatively (present/absent) evaluation of fatty or fibrous lesions. Intrareader reliability for detecting and scoring these lesions was excellent (Cohen's kappa 0.81) and inter-reader reliability was good (Light's kappa 0.66). CONCLUSION: New definitions for developing a novel semiquantitative US score in patients with pSS were developed and tested on video clips. Inter-reader and intrareader reliabilities were good and excellent, respectively.


Assuntos
Interpretação de Imagem Assistida por Computador/normas , Glândulas Salivares/diagnóstico por imagem , Síndrome de Sjogren/diagnóstico por imagem , Ultrassonografia/normas , Consenso , Técnica Delphi , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ultrassonografia/métodos
6.
J Rheumatol ; 45(12): 1628-1635, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30173153

RESUMO

OBJECTIVE: Obese patients with rheumatoid arthritis (RA) report more joint swelling and tenderness and often have poorer responses to therapy than nonobese patients. The aim of this posthoc analysis of the MUSICA trial was to compare imaging and clinical disease activity measures in obese and nonobese patients with RA. METHODS: MUSICA evaluated methotrexate (MTX) 20 mg/week versus 7.5 mg/week in combination with adalimumab (ADA) in RA patients with an inadequate response to MTX. Patients were categorized by baseline body mass index as normal (< 25), overweight (≥ 25 to < 30), or obese (≥ 30). Synovial vascularity and hypertrophy, swollen and tender joint counts (SJC and TJC), American College of Rheumatology (ACR) responses, and low disease activity (LDA), defined as Clinical Disease Activity Index < 10 and 28-joint count Disease Activity Score using C-reactive protein (DAS28-CRP) < 3.2, were assessed at weeks 12 and 24. RESULTS: Patient characteristics were similar among groups at baseline. Obese patients had numerically smaller changes from baseline to weeks 12/24 in SJC, TJC, DAS28-CRP, and synovial hypertrophy and vascularity versus nonobese patients. Significantly fewer obese patients reached ACR20/50 at weeks 12 and 24, and LDA at Week 12; this difference was especially apparent in patients receiving 7.5 mg/week MTX but was no longer significant at Week 24. CONCLUSION: Obese patients with RA had worse clinical and ultrasonographic responses than nonobese patients, which were partly overcome with time. Obese patients may experience better and faster clinical improvements if ADA is initiated with high-dose (20 mg/week) rather than low-dose MTX. [ClinicalTrials.gov: NCT01185288].


Assuntos
Adalimumab/uso terapêutico , Antirreumáticos/uso terapêutico , Artrite Reumatoide/tratamento farmacológico , Metotrexato/uso terapêutico , Obesidade/complicações , Membrana Sinovial/irrigação sanguínea , Adalimumab/farmacologia , Antirreumáticos/farmacologia , Artrite Reumatoide/complicações , Método Duplo-Cego , Quimioterapia Combinada , Feminino , Humanos , Masculino , Metotrexato/farmacologia , Membrana Sinovial/efeitos dos fármacos , Resultado do Tratamento
7.
Rheumatol Ther ; 5(1): 123-134, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29574622

RESUMO

INTRODUCTION: In patients with rheumatoid arthritis (RA), combination treatment with methotrexate (MTX) and adalimumab is more effective than MTX monotherapy. From the patients' perspective, the impact of reduced MTX doses upon initiating adalimumab is not known. The objective was to evaluate the effects of low and high MTX doses in combination with adalimumab initiation on patient-reported outcomes (PROs), in MTX-inadequate responders (MTX-IR) with moderate-to-severe RA. METHODS: MUSICA was a randomized, double-blind, controlled trial evaluating the efficacy of 7.5 or 20 mg/week MTX, in combination with adalimumab for 24 weeks in MTX-IR RA patients receiving prior MTX ≥ 15 mg/week for ≥ 12 weeks. PROs were recorded at each visit, including physical function, health-related quality-of-life, work productivity, quality-of-sleep, satisfaction with treatment medication, sexual impairment due to RA, patient global assessment of disease activity (PGA), and patient pain. Last observation carried forward was used to account for missing values. RESULTS: At baseline, patients in both MTX dosage groups had similar demographics, disease characteristics, and PRO scores. Overall, initiation of adalimumab led to significant improvements from baseline in the PROs assessed for both MTX dosage groups. Improvements in presenteeism from baseline were strongly correlated with corresponding improvements in SF-36 (vitality), pain, and physical function. Physical and mental well-being had a good correlation with improvement in sleep. Overall, improvements in disease activity from baseline were correlated with improvements in several PROs. CONCLUSIONS: The addition of adalimumab to MTX in MTX-IR patients with moderate-to-severe RA led to improvements in physical function, quality-of-life, work productivity, quality of sleep, satisfaction with treatment medication, and sexual impairment due to RA, regardless of the concomitant MTX dosage. FUNDING: AbbVie. TRIAL REGISTRATION: Clinicaltrials.gov identifier, NCT01185288.

8.
Ann Rheum Dis ; 77(8): 1194-1199, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29535120

RESUMO

OBJECTIVES: To assess the reliability of the OMERACT ultrasound (US) definitions for the identification of calcium pyrophosphate deposition disease (CPPD) at the metacarpal-phalangeal, triangular fibrocartilage of the wrist (TFC), acromioclavicular (AC) and hip joints. METHODS: A web-based exercise and subsequent patient-based exercise were carried out. A panel of 30 OMERACT members, participated at the web-based exercise by evaluating twice a set of US images for the presence/absence of CPPD. Afterwards, 19 members of the panel met in Siena, Italy, for the patient-based exercise. During the exercise, all sonographers examined twice eight patients for the presence/absence of CPPD at the same joints. Intraoberserver and interobserver kappa values were calculated for both exercises. RESULTS: The web-based exercise yielded high kappa values both in intraobserver and interobserver evaluation for all sites, while in the patient-based exercise, inter-reader agreement was acceptable for the TFC and the AC. TFC reached high interobserver and intraobserver k values in both exercises, ranging from 0.75 to 0.87 (good to excellent agreement). AC reached moderate kappa values, from 0.51 to 0.85 (moderate to excellent agreement) and can readily be used for US CPPD identification. CONCLUSIONS: Based on the results of our exercise, the OMERACT US definitions for the identification of CPPD demonstrated to be reliable when applied to the TFC and AC. Other sites reached good kappa values in the web-based exercise but failed to achieve good reproducibility at the patient-based exercise, meaning the scanning method must be further refined.


Assuntos
Condrocalcinose/diagnóstico por imagem , Ultrassonografia/normas , Articulação Acromioclavicular/diagnóstico por imagem , Idoso , Feminino , Articulação do Quadril/diagnóstico por imagem , Humanos , Cooperação Internacional , Internet , Masculino , Articulação Metacarpofalângica/diagnóstico por imagem , Pessoa de Meia-Idade , Variações Dependentes do Observador , Sistemas de Informação em Radiologia , Reprodutibilidade dos Testes , Ultrassonografia/métodos , Articulação do Punho/diagnóstico por imagem
9.
RMD Open ; 3(2): e000465, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28955494

RESUMO

BACKGROUND: Treatment of rheumatoid arthritis (RA) with a combination of methotrexate (MTX)+adalimumab (ADA) is more effective than ADA monotherapy. We assessed the toxicity of different doses of MTX and treatment efficacy of ADA+MTX in two trials. METHODS: Data originated from CONCERTO, in patients with early RA initiating ADA+ 2.5, 5, 10 or 20 mg/week MTX for 26 weeks; and MUSICA, in patients with an inadequate response to MTX initiating ADA+ 7.5 or 20 mg/week MTX for 24 weeks. Efficacy was assessed by the American College of Rheumatology 50 (ACR50). Patient-reported MTX-related toxicity information was collected at each visit on 18 prespecified MTX-related adverse events (AE) in the MTX label. RESULTS: In CONCERTO, ACR50 rates increased over time, ranging from 54% to 68% at week 26, while AE rates remained steady, ranging from 2.4% to 17.8% at week 26. Of 395 patients, 113 (28.6%) reported 345 MTX-related AEs, including one serious AE (SAE, excessive fatigue and/or malaise); 10 AEs (in two patients) led to study discontinuation. In MUSICA, ACR50 rates increased over time, and were 32.3% and 37.5% at week 24, while MTX-related AE rates remained steady and were 6.5% at week 24. Of 309 patients, 71 (23%) reported 185 MTX-related AEs, including 5 SAEs (four infections and one fever/chills); six AEs (in four patients) led to study discontinuation. CONCLUSION: In patients with RA initiating ADA+MTX combination, treatment efficacy was achieved and increased throughout both trials, while rates of MTX-related AEs remained steady. MTX-related AEs were observed in up to 30% of patients and most were mild. MTX was discontinued by 0.5%-1.3% of patients. TRIAL REGISTRATION NUMBER: MUSICA (NCT01185288), CONCERTO (NCT01185301), Post results.

10.
Arthritis Rheumatol ; 68(11): 2584-2592, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27214046

RESUMO

OBJECTIVE: To assess joint disease activity by ultrasound (US) in patients with rheumatoid arthritis (RA) initiating treatment with adalimumab (ADA) plus methotrexate (MTX). METHODS: Data for this post hoc analysis originated from the MUSICA trial (ClinicalTrials.gov identifier: NCT01185288), which evaluated the efficacy of initiating ADA (40 mg every other week) plus 7.5 or 20 mg/week MTX in 309 patients with RA with an inadequate response to MTX. Synovial vascularization over 24 weeks was assessed bilaterally at metacarpophalangeal joint 2 (MCP2), MCP3, MCP5, metatarsophalangeal joint 5, and the wrists by power Doppler US (PDUS). A semiquantitative 4-grade scale was used. Disease activity was assessed using the Disease Activity Score in 28 joints using the C-reactive protein level (DAS28-CRP) and Simplified Disease Activity Index (SDAI). The correlation between continuous variables was assessed using Pearson's correlation coefficient. RESULTS: After 24 weeks of treatment with ADA plus MTX, rapid improvements in the mean synovial vascularity score were observed; the greatest improvements were in MCP2 (-0.5), MCP3 (-0.4), and the wrist (-0.4). At week 24, patients with the lowest DAS28-CRP (<2.6) had the lowest mean 5-joint and 3-joint composite synovial vascularity scores. The 5-joint and 3-joint scores were strongly correlated (ρ > 0.9). Synovial vascularity scores correlated poorly with DAS28, swollen joint count in 66 joints (SJC66), SJC28, tender joint count in 68 joints (TJC68), TJC28, Clinical Disease Activity Index (CDAI), SDAI, physician's global assessment, patient's global assessment of pain, and disease duration (ρ < 0.2). Thirty-two (70%) of 46 patients with a DAS28-CRP of <2.6, and 11 (58%) of 19 patients with an SDAI indicating remission had at least 1 joint with a synovial vascularity score of ≥1. CONCLUSION: PDUS detects changes in synovial vascularity in RA patients treated with ADA plus MTX, and residual synovial vascularity in patients in whom clinical disease control has been achieved.


Assuntos
Adalimumab/uso terapêutico , Antirreumáticos/uso terapêutico , Artrite Reumatoide/tratamento farmacológico , Articulação da Mão/diagnóstico por imagem , Articulação Metatarsofalângica/diagnóstico por imagem , Metotrexato/uso terapêutico , Adulto , Idoso , Artrite Reumatoide/diagnóstico por imagem , Artrite Reumatoide/imunologia , Proteína C-Reativa/imunologia , Método Duplo-Cego , Quimioterapia Combinada , Feminino , Humanos , Masculino , Articulação Metacarpofalângica/diagnóstico por imagem , Pessoa de Meia-Idade , Neovascularização Patológica/diagnóstico por imagem , Ensaios Clínicos Controlados Aleatórios como Assunto , Índice de Gravidade de Doença , Membrana Sinovial/diagnóstico por imagem , Ultrassonografia Doppler , Articulação do Punho/diagnóstico por imagem
11.
Phys Sportsmed ; 38(2): 35-47, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20631462

RESUMO

We compared the efficacy and safety of intra-articular hylan G-F 20 with methylprednisolone acetate (MPA) for treating symptomatic Kellgren-Lawrence grade (KLG) 2 or 3 hip osteoarthritis in a prospective, randomized, multicenter, double-blind trial (N = 313). Two injections of hylan G-F 20 were administered 2 weeks apart (n = 150), or 1 injection of 40 mg MPA and 1 sham injection 2 weeks later (n = 155). The Western Ontario and McMaster Universities Arthritis Index (WOMAC) (total and subscale), clinician observations, and patient global assessments were collected at baseline and at weeks 4, 8, 12, 16, 20, and 26 (intent-to-treat population was analyzed; n = 305). Responder rates were assessed by WOMAC domain A, and criteria were established by the Outcome Measures in Rheumatology Clinical Trials-Osteoarthritis Research Society International (OMERACT-OARSI). At week 26, WOMAC A improved by 16.6 mm for hylan G-F 20 versus 13.6 mm for MPA. Response rates were higher with hylan G-F 20 versus MPA in patients with more advanced disease (KLG 3) and were similar between hylan G-F 20 and MPA in patients with less advanced disease (KLG 2). Adverse events were similar between groups and between patients with KLG 2 or 3. Hylan G-F 20 provided clinically meaningful improvements in pain and function, comparable with those of MPA, with good safety and tolerability. Thus, we conclude it is an appropriate option for treating hip osteoarthritis.


Assuntos
Osteoartrite do Quadril , Osteoartrite do Joelho , Método Duplo-Cego , Humanos , Injeções Intra-Articulares , Medição da Dor , Estudos Prospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA