Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
Nat Med ; 29(12): 3111-3119, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37946058

RESUMO

Over one million European children undergo computed tomography (CT) scans annually. Although moderate- to high-dose ionizing radiation exposure is an established risk factor for hematological malignancies, risks at CT examination dose levels remain uncertain. Here we followed up a multinational cohort (EPI-CT) of 948,174 individuals who underwent CT examinations before age 22 years in nine European countries. Radiation doses to the active bone marrow were estimated on the basis of body part scanned, patient characteristics, time period and inferred CT technical parameters. We found an association between cumulative dose and risk of all hematological malignancies, with an excess relative risk of 1.96 (95% confidence interval 1.10 to 3.12) per 100 mGy (790 cases). Similar estimates were obtained for lymphoid and myeloid malignancies. Results suggest that for every 10,000 children examined today (mean dose 8 mGy), 1-2 persons are expected to develop a hematological malignancy attributable to radiation exposure in the subsequent 12 years. Our results strengthen the body of evidence of increased cancer risk at low radiation doses and highlight the need for continued justification of pediatric CT examinations and optimization of doses.


Assuntos
Neoplasias Hematológicas , Neoplasias Induzidas por Radiação , Exposição à Radiação , Humanos , Criança , Adolescente , Adulto Jovem , Adulto , Doses de Radiação , Neoplasias Induzidas por Radiação/epidemiologia , Neoplasias Induzidas por Radiação/etiologia , Neoplasias Induzidas por Radiação/patologia , Neoplasias Hematológicas/epidemiologia , Neoplasias Hematológicas/etiologia , Exposição à Radiação/efeitos adversos , Tomografia Computadorizada por Raios X/efeitos adversos
2.
Phys Med ; 115: 103159, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37852021

RESUMO

It is well known that foetuses are highly sensitive to ionising radiation and special attention to justification and optimisation of radiological procedures involving a pregnant patient is required. A task to review, validate and compare different approaches to managing the pregnant patient and to estimating the associated foetal doses arising from a diagnostic or interventional radiology (DIR) procedure was designed in the framework of EURADOS working group 12. As a first step, a survey of radiation protection practice including dosimetry considerations among EURADOS members was performed using online questionnaire. Then, to evaluate the possible differences in the estimated foetal doses, a comparison of assessed dose values was made for three cases of pregnant patients that underwent different CT procedures. More than 120 professionals from 108 institutions and 17 countries that are involved in managing pregnant patients undergoing DIR procedures answered the questionnaire. Most of the respondents use national or hospital guidelines on the management of pregnant patients undergoing DIR procedures. However, the guidelines differ considerably among respondents. Comparison of foetal dose assessments performed by dosimetry experts showed the variety of methods used as well as large variability of estimated foetal doses in all three cases. Although European and International commission on radiation protection guidelines already exist, they are more than 20 years old and, in some aspects, they are obsolete. This paper shows that there is a need to revise and update these guidelines.


Assuntos
Proteção Radiológica , Radiologia Intervencionista , Gravidez , Feminino , Humanos , Adulto Jovem , Adulto , Doses de Radiação , Proteção Radiológica/métodos , Radiografia , Radiometria
3.
Acta Radiol ; 64(1): 125-138, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34935520

RESUMO

BACKGROUND: Optimizing patient exposure in interventional cardiology is key to avoid skin injuries. PURPOSE: To establish predictive models of peak skin dose (PSD) during percutaneous coronary intervention (PCI), chronic total occlusion percutaneous coronary intervention (CTO), and transcatheter aortic valve implantation (TAVI) procedures. MATERIAL AND METHODS: A total of 534 PCI, 219 CTO, and 209 TAVI were collected from 12 hospitals in eight European countries. Independent associations between PSD and clinical and technical dose determinants were examined for those procedures using multivariate statistical analysis. A priori and a posteriori predictive models were built using stepwise multiple linear regressions. A fourfold cross-validation was performed, and models' performance was evaluated using the root mean square error (RMSE), mean absolute percentage error (MAPE), coefficient of determination (R²), and linear correlation coefficient (r). RESULTS: Multivariate analysis proved technical parameters to overweight clinical complexity indices with PSD mainly affected by fluoroscopy time, tube voltage, tube current, distance to detector, and tube angulation for PCI. For CTO, these were body mass index, tube voltage, and fluoroscopy contribution. For TAVI, these parameters were sex, fluoroscopy time, tube voltage, and cine acquisitions. When benchmarking the predictive models, the correlation coefficients were r = 0.45 for the a priori model and r = 0.89 for the a posteriori model for PCI. These were 0.44 and 0.67, respectively, for the CTO a priori and a posteriori models, and 0.58 and 0.74, respectively, for the TAVI a priori and a posteriori models. CONCLUSION: A priori predictive models can help operators estimate the PSD before performing the intervention while a posteriori models are more accurate estimates and can be useful in the absence of skin dose mapping solutions.


Assuntos
Cardiologia , Intervenção Coronária Percutânea , Humanos , Doses de Radiação , Pele , Projetos de Pesquisa , Cardiologia/métodos , Fluoroscopia , Angiografia Coronária , Resultado do Tratamento , Radiografia Intervencionista
4.
Acta Radiol ; 64(1): 108-118, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34958271

RESUMO

BACKGROUND: Patients can be exposed to high skin doses during complex interventional cardiology (IC) procedures. PURPOSE: To identify which clinical and technical parameters affect patient exposure and peak skin dose (PSD) and to establish dose reference levels (DRL) per clinical complexity level in IC procedures. MATERIAL AND METHODS: Validation and Estimation of Radiation skin Dose in Interventional Cardiology (VERIDIC) project analyzed prospectively collected patient data from eight European countries and 12 hospitals where percutaneous coronary intervention (PCI), chronic total occlusion PCI (CTO), and transcatheter aortic valve implantation (TAVI) procedures were performed. A total of 62 clinical complexity parameters and 31 technical parameters were collected, univariate regressions were performed to identify those parameters affecting patient exposure and define DRL accordingly. RESULTS: Patient exposure as well as clinical and technical parameters were collected for a total of 534 PCI, 219 CTO, and 209 TAVI. For PCI procedures, body mass index (BMI), number of stents ≥2, and total stent length >28 mm were the most prominent clinical parameters, which increased the PSD value. For CTO, these were total stent length >57 mm, BMI, and previous anterograde or retrograde technique that failed in the same session. For TAVI, these were male sex, BMI, and number of diseased vessels. DRL values for Kerma-area product (PKA), air kerma at patient entrance reference point (Ka,r), fluoroscopy time (FT), and PSD were stratified, respectively, for 14 clinical parameters in PCI, 10 in CTO, and four in TAVI. CONCLUSION: Prior knowledge of the key factors influencing the PSD will help optimize patient radiation protection in IC.


Assuntos
Cardiologia , Intervenção Coronária Percutânea , Humanos , Masculino , Feminino , Doses de Radiação , Radiografia Intervencionista/métodos , Cardiologia/métodos , Europa (Continente) , Fluoroscopia/métodos , Angiografia Coronária
5.
Lancet Oncol ; 24(1): 45-53, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36493793

RESUMO

BACKGROUND: The European EPI-CT study aims to quantify cancer risks from CT examinations of children and young adults. Here, we assess the risk of brain cancer. METHODS: We pooled data from nine European countries for this cohort study. Eligible participants had at least one CT examination before age 22 years documented between 1977 and 2014, had no previous diagnosis of cancer or benign brain tumour, and were alive and cancer-free at least 5 years after the first CT. Participants were identified through the Radiology Information System in 276 hospitals. Participants were linked with national or regional registries of cancer and vital status, and eligible cases were patients with brain cancers according to WHO International Classification of Diseases for Oncology. Gliomas were analysed separately to all brain cancers. Organ doses were reconstructed using historical machine settings and a large sample of CT images. Excess relative risks (ERRs) of brain cancer per 100 mGy of cumulative brain dose were calculated with linear dose-response modelling. The outcome was the first reported diagnosis of brain cancer after an exclusion period of 5 years after the first electronically recorded CT examination. FINDINGS: We identified 948 174 individuals, of whom 658 752 (69%) were eligible for our study. 368 721 (56%) of 658 752 participants were male and 290 031 (44%) were female. During a median follow-up of 5·6 years (IQR 2·4-10·1), 165 brain cancers occurred, including 121 (73%) gliomas. Mean cumulative brain dose, lagged by 5 years, was 47·4 mGy (SD 60·9) among all individuals and 76·0 mGy (100·1) among people with brain cancer. A significant linear dose-response relationship was observed for all brain cancers (ERR per 100 mGy 1·27 [95% CI 0·51-2·69]) and for gliomas separately (ERR per 100 mGy 1·11 [0·36-2·59]). Results were robust when the start of follow-up was delayed beyond 5 years and when participants with possibly previously unreported cancers were excluded. INTERPRETATION: The observed significant dose-response relationship between CT-related radiation exposure and brain cancer in this large, multicentre study with individual dose evaluation emphasises careful justification of paediatric CTs and use of doses as low as reasonably possible. FUNDING: EU FP7; Belgian Cancer Registry; La Ligue contre le Cancer, L'Institut National du Cancer, France; Ministry of Health, Labour and Welfare of Japan; German Federal Ministry of Education and Research; Worldwide Cancer Research; Dutch Cancer Society; Research Council of Norway; Consejo de Seguridad Nuclear, Generalitat de Catalunya, Spain; US National Cancer Institute; UK National Institute for Health Research; Public Health England.


Assuntos
Neoplasias Encefálicas , Glioma , Neoplasias Induzidas por Radiação , Exposição à Radiação , Criança , Humanos , Masculino , Feminino , Adulto Jovem , Adulto , Estudos de Coortes , Doses de Radiação , Neoplasias Induzidas por Radiação/epidemiologia , Neoplasias Induzidas por Radiação/etiologia , Neoplasias Induzidas por Radiação/patologia , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/epidemiologia , Neoplasias Encefálicas/etiologia , Glioma/diagnóstico por imagem , Glioma/epidemiologia , Glioma/etiologia , Exposição à Radiação/efeitos adversos , Tomografia Computadorizada por Raios X/efeitos adversos , Tomografia Computadorizada por Raios X/métodos
6.
Radiat Res ; 196(1): 74-99, 2021 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-33914893

RESUMO

Within the European Epidemiological Study to Quantify Risks for Paediatric Computerized Tomography (EPI-CT study), a cohort was assembled comprising nearly one million children, adolescents and young adults who received over 1.4 million computed tomography (CT) examinations before 22 years of age in nine European countries from the late 1970s to 2014. Here we describe the methods used for, and the results of, organ dose estimations from CT scanning for the EPI-CT cohort members. Data on CT machine settings were obtained from national surveys, questionnaire data, and the Digital Imaging and Communications in Medicine (DICOM) headers of 437,249 individual CT scans. Exposure characteristics were reconstructed for patients within specific age groups who received scans of the same body region, based on categories of machines with common technology used over the time period in each of the 276 participating hospitals. A carefully designed method for assessing uncertainty combined with the National Cancer Institute Dosimetry System for CT (NCICT, a CT organ dose calculator), was employed to estimate absorbed dose to individual organs for each CT scan received. The two-dimensional Monte Carlo sampling method, which maintains a separation of shared and unshared error, allowed us to characterize uncertainty both on individual doses as well as for the entire cohort dose distribution. Provided here are summaries of estimated doses from CT imaging per scan and per examination, as well as the overall distribution of estimated doses in the cohort. Doses are provided for five selected tissues (active bone marrow, brain, eye lens, thyroid and female breasts), by body region (i.e., head, chest, abdomen/pelvis), patient age, and time period (1977-1990, 1991-2000, 2001-2014). Relatively high doses were received by the brain from head CTs in the early 1990s, with individual mean doses (mean of 200 simulated values) of up to 66 mGy per scan. Optimization strategies implemented since the late 1990s have resulted in an overall decrease in doses over time, especially at young ages. In chest CTs, active bone marrow doses dropped from over 15 mGy prior to 1991 to approximately 5 mGy per scan after 2001. Our findings illustrate patterns of age-specific doses and their temporal changes, and provide suitable dose estimates for radiation-induced risk estimation in epidemiological studies.


Assuntos
Doses de Radiação , Tomografia Computadorizada por Raios X , Adolescente , Criança , Pré-Escolar , Estudos de Coortes , Europa (Continente)/epidemiologia , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Imagens de Fantasmas
7.
Phys Med ; 82: 279-294, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33706118

RESUMO

PURPOSE: Online and offline software products can estimate the maximum skin dose (MSD) delivered to the patient during interventional cardiology procedures. The capabilities and accuracy of several skin dose mapping (SDM) software products were assessed on X-ray systems from the main manufacturers following a common protocol. METHODS: Skin dose was measured on four X-ray systems following a protocol composed of nine fundamental irradiation set-ups and three set-ups simulating short, clinical procedures. Dosimeters/multimeters with semiconductor-based detectors, radiochromic films and thermoluminescent dosimeters were used. Results were compared with up to eight of 10 SDM products, depending on their compatibility. RESULTS: The MSD estimates generally agreed with the measurements within ± 40% for fundamental irradiation set-ups and simulated procedures. Only three SDM products provided estimates within ± 40% for all tested configurations on at least one compatible X-ray system. No SDM product provided estimates within ± 40% for all combinations of configurations and compatible systems. The accuracy of the MSD estimate for lateral irradiations was variable and could be poor (up to 66% underestimation). Most SDM products produced maps which qualitatively represented the dimensions, the shape and the relative position of the MSD region. Some products, however, missed the MSD region when situated at the intersection of multiple fields, which is of radiation protection concern. CONCLUSIONS: It is very challenging to establish a common protocol for quality control (QC) and acceptance testing because not all information necessary for accurate MSD calculation is available or standardised in the radiation dose structured reports (RDSRs).


Assuntos
Cardiologia , Proteção Radiológica , Fluoroscopia , Humanos , Doses de Radiação , Dosímetros de Radiação , Pele , Software
8.
Phys Med ; 80: 75-83, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33125968

RESUMO

PURPOSE: In interventional cardiology, patients may be exposed to high doses to the skin resulting in skin burns following single or multiple procedures. Reviewing and analysing available software (online or offline) may help medical physicists assessing the maximum skin dose to the patient together with the dose distribution during (or after) these procedures. METHOD AND RESULTS: Capabilities and accuracy of available software were analysed through an extensive bibliography search and contacts with both vendor and authors. Their markedly differed among developers. In total, 22 software were identified and reviewed according to their algorithms and their capabilities. Special attention was dedicated to their main features and limitations of interest for the intended clinical use. While the accuracy of the 12 software products validated with measurements on phantoms was acceptable (within ± 25%), the agreement was poor for the two products validated on patients (within ± 43% and ± 76%, respectively). In addition, no software has been validated on angiographic units from all manufacturers, though several software developers claimed vendor-independent transportability. Only one software allows for multiple procedures dose calculation. CONCLUSION: Large differences among vendors made it clear that work remains to be done before an accurate and reliable skin dose mapping is available for all patients.


Assuntos
Cardiologia , Software , Humanos , Imagens de Fantasmas , Doses de Radiação , Pele
9.
Am J Cardiol ; 116(8): 1179-84, 2015 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-26275581

RESUMO

The increasing number and complexity of these procedures have led to a higher number of patients at risk for tissue reactions like skin injuries. Monitoring of their dose indicators is essential in recognizing these patients. The aim of this work was to determine local diagnostic reference levels (DRLs) for recanalization of chronic total occlusion (CTO) and other occlusions procedures. All data from patients who underwent cardiac procedures were reviewed and classified according to their complexity. Dose indicators such as fluoroscopy time (FT), dose area product (DAP), and air kerma at patient entrance reference point (AKr) were recorded. Correlations with patient's body mass index, operators, procedure strategy, and complexity were studied. For CTO, the mean DAP, AKr, and FT were 252 ± 234 Gycm(2), 3,985 ± 3,579 mGy, and 47 ± 36 minutes, respectively. To better reflect the non-Gaussian distribution of data, the median and the 75th percentile values were also reported: median DAP, 172 Gycm(2); 75th percentile DAP, 350 Gycm(2); median AKr, 2,714 mGy; and 75th percentile AKr, 5,921 mGy. A tentative new set of values were suggested to take into account the complexity difference in recanalization of total occlusions according to their antegrade or retrograde approach. These approach-specific DRLs for total occlusions were mean DAP (120 ± 114 Gycm(2)), mean AKr (1,789 ± 1,933 mGy), and mean FT (22 ± 18 minutes) for antegrade approach and mean DAP (459 ± 304 Gycm(2)), mean AKr (6,881 ± 4,243 mGy), and mean FT (82 ± 40 minutes) for retrograde approach. The other significant values were median DAP (84 Gycm(2)), 75th percentile DAP (147 Gycm(2)), median AKr (1,160 mGy), and 75th percentile AKr (2,176 mGy) for antegrade approach and median DAP (422 Gycm(2)), 75th percentile DAP (552 Gycm(2)), median AKr (6,295 mGy), and 75th percentile AKr (8,064 mGy) for retrograde approach. In conclusion, a set of local DRL values from a large center were assessed. DRLs were provided for antegrade and retrograde approaches, reflecting the difference in difficulty from these 2 kinds of CTOs. The wide dose estimator values variations were explained through procedure complexity. The values obtained for the other more classic percutaneous coronary interventions were comparable with those found in the literature.


Assuntos
Institutos de Cardiologia , Cateterismo Cardíaco , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/cirurgia , Intervenção Coronária Percutânea , Doses de Radiação , Idoso , Idoso de 80 Anos ou mais , Índice de Massa Corporal , Doença Crônica , Angiografia Coronária , Feminino , Fluoroscopia , França , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Seleção de Pacientes , Exposição à Radiação , Valores de Referência , Reoperação , Estudos Retrospectivos
10.
J Radiol Prot ; 35(3): 611-28, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26226081

RESUMO

Computed tomography (CT) has great clinical utility and its usage has increased dramatically over the years. Concerns have been raised, however, about health impacts of ionising radiation exposure from CTs, particularly in children, who have a higher risk for some radiation induced diseases. Direct estimation of the health impact of these exposures is needed, but the conduct of epidemiological studies of paediatric CT populations poses a number of challenges which, if not addressed, could invalidate the results. The aim of the present paper is to review the main challenges of a study on the health impact of paediatric CTs and how the protocol of the European collaborative study EPI-CT, coordinated by the International Agency for Research on Cancer (IARC), is designed to address them. The study, based on a common protocol, is being conducted in Belgium, Denmark, France, Germany, the Netherlands, Norway, Spain, Sweden and the United Kingdom and it has recruited over one million patients suitable for long-term prospective follow-up. Cohort accrual relies on records of participating hospital radiology departments. Basic demographic information and technical data on the CT procedure needed to estimate organ doses are being abstracted and passive follow-up is being conducted by linkage to population-based cancer and mortality registries. The main issues which may affect the validity of study results include missing doses from other radiological procedures, missing CTs, confounding by CT indication and socioeconomic status and dose reconstruction. Sub-studies are underway to evaluate their potential impact. By focusing on the issues which challenge the validity of risk estimates from CT exposures, EPI-CT will be able to address limitations of previous CT studies, thus providing reliable estimates of risk of solid tumours and leukaemia from paediatric CT exposures and scientific bases for the optimisation of paediatric CT protocols and patient protection.


Assuntos
Neoplasias Induzidas por Radiação/epidemiologia , Pediatria , Tomografia Computadorizada por Raios X/efeitos adversos , Métodos Epidemiológicos , Europa (Continente)/epidemiologia , Humanos , Proteção Radiológica , Medição de Risco , Fatores de Risco
11.
Eur Heart J ; 35(10): 665-72, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24401558

RESUMO

The benefits of cardiac imaging are immense, and modern medicine requires the extensive and versatile use of a variety of cardiac imaging techniques. Cardiologists are responsible for a large part of the radiation exposures every person gets per year from all medical sources. Therefore, they have a particular responsibility to avoid unjustified and non-optimized use of radiation, but sometimes are imperfectly aware of the radiological dose of the examination they prescribe or practice. This position paper aims to summarize the current knowledge on radiation effective doses (and risks) related to cardiac imaging procedures. We have reviewed the literature on radiation doses, which can range from the equivalent of 1-60 milliSievert (mSv) around a reference dose average of 15 mSv (corresponding to 750 chest X-rays) for a percutaneous coronary intervention, a cardiac radiofrequency ablation, a multidetector coronary angiography, or a myocardial perfusion imaging scintigraphy. We provide a European perspective on the best way to play an active role in implementing into clinical practice the key principle of radiation protection that: 'each patient should get the right imaging exam, at the right time, with the right radiation dose'.


Assuntos
Técnicas de Imagem Cardíaca/efeitos adversos , Cardiopatias/diagnóstico por imagem , Doses de Radiação , Cardiologia , Criança , Feminino , Cardiopatias/terapia , Humanos , Consentimento Livre e Esclarecido , Exposição Ocupacional/efeitos adversos , Exposição Ocupacional/prevenção & controle , Gravidez , Complicações na Gravidez/etiologia , Diagnóstico Pré-Natal/efeitos adversos , Lesões por Radiação/etiologia , Proteção Radiológica/métodos , Proteção Radiológica/normas , Fatores de Risco , Tomografia Computadorizada por Raios X/efeitos adversos , Procedimentos Desnecessários
12.
Catheter Cardiovasc Interv ; 83(5): 729-38, 2014 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-24323486

RESUMO

OBJECTIVES: To evaluate practices for the protection from radiation of patients during coronary angiography (CA) and percutaneous coronary intervention (PCI), and to update reference values for the main radiation dose parameters. BACKGROUND: Few multicenter data from large populations exist on radiation doses to patients during CA and PCI. METHODS: RAY'ACT is a multicenter, nationwide French survey, with retrospective analysis of radiation parameters routinely registered in professional software from 33,937 CAs and 27,826 PCIs performed at 44 centers from January 1, through December 31, 2010. RESULTS: Kerma-area product (KAP) was registered in 91.7% (44/48) of centers and in 91.5% of procedures for CA (median, 27.2 Gy·cm(2) , interquartile range [IQR], 15.5-45.2) and 91.1% for PCI (median, 56.8 Gy·cm(2) , IQR, 32.8-94.6). Fluoroscopy time was registered in 87.5% (42/48) of centers and in 83.1% of procedures (median, 3.7 min, IQR, 2.3-6.3 for CA; 10.3 min, 6.7-16.2 for PCI). Variability across centers was high. Old equipment and routine left ventriculography were more common and number of registered frames and frame rate were higher in centers delivering high doses. The radial route was associated with lower doses than the femoral route (median KAP 26.8 Gy·cm(2) [15.1-44.25] vs. 28.1 [16.4-46.9] for CA, respectively; and 55.6 Gy·cm(2) [32.2-92.1] vs. 59.4 [24.6-99.9] for PCI, respectively; P < 0.01). CONCLUSIONS: This survey showed a very high rate of compliance with dose registration during CA and PCI in French nonacademic hospitals. Updated diagnostic reference values are established for the main dose parameters (KAP, 45 Gy·cm(2) for CA, 95 Gy·cm(2) for PCI).


Assuntos
Angiografia Coronária , Intervenção Coronária Percutânea , Doses de Radiação , Lesões por Radiação/prevenção & controle , Radiografia Intervencionista , Idoso , Angiografia Coronária/efeitos adversos , Angiografia Coronária/normas , Feminino , Artéria Femoral/diagnóstico por imagem , Fluoroscopia , França , Fidelidade a Diretrizes , Pesquisas sobre Atenção à Saúde , Humanos , Masculino , Pessoa de Meia-Idade , Segurança do Paciente , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/normas , Guias de Prática Clínica como Assunto , Padrões de Prática Médica , Valor Preditivo dos Testes , Artéria Radial/diagnóstico por imagem , Lesões por Radiação/etiologia , Radiografia Intervencionista/efeitos adversos , Radiografia Intervencionista/normas , Valores de Referência , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo
13.
Int J Environ Res Public Health ; 10(2): 717-28, 2013 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-23429160

RESUMO

The increasing worldwide use of paediatric computed tomography (CT) has led to increasing concerns regarding the subsequent effects of exposure to radiation. In response to this concern, the international EPI-CT project was developed to study the risk of cancer in a large multi-country cohort. In radiation epidemiology, accurate estimates of organ-specific doses are essential. In EPI-CT, data collection is split into two time periods--before and after introduction of the Picture Archiving Communication System (PACS) introduced in the 1990s. Prior to PACS, only sparse information about scanner settings is available from radiology departments. Hence, a multi-level approach was developed to retrieve information from a questionnaire, surveys, scientific publications, and expert interviews. For the years after PACS was introduced, scanner settings will be extracted from Digital Imaging and Communications in Medicine (DICOM) headers, a protocol for storing medical imaging data. Radiation fields and X-ray interactions within the body will be simulated using phantoms of various ages and Monte-Carlo-based radiation transport calculations. Individual organ doses will be estimated for each child using an accepted calculation strategy, scanner settings, and the radiation transport calculations. Comprehensive analyses of missing and uncertain dosimetry data will be conducted to provide uncertainty distributions of doses.


Assuntos
Neoplasias/epidemiologia , Doses de Radiação , Tomografia Computadorizada por Raios X , Adolescente , Criança , Pré-Escolar , Europa (Continente)/epidemiologia , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Método de Monte Carlo , Inquéritos e Questionários , Adulto Jovem
14.
Int J Cardiol ; 167(5): 1843-7, 2013 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-22608271

RESUMO

BACKGROUND: Interventional cardiologists (ICs) are exposed to X-rays and may be at risk to develop cataract earlier than common senile cataract. Excess risk of posterior subcapsular cataract, known as radiation-induced, was previously observed in samples of ICs from Malaysia, and Latin America. The O'CLOC study (Occupational Cataracts and Lens Opacities in interventional Cardiology) was performed to quantify the risk at the scale of France. METHODS: This cross-sectional multicenter study included an exposed group of ICs from different French centers and an unexposed control group of non-medical workers. Individual information was collected about cataract risk factors and past and present workload in catheterization laboratory. All participants had a clinical eye examination to classify the lens opacities (nuclear, cortical, or posterior subcapsular) with the international standard classification LOCS III. RESULTS: The study included 106 ICs (mean age = 51 ± 7 years) and 99 unexposed control subjects (mean age = 50 ± 7 years). The groups did not differ significantly in the prevalence of either nuclear or cortical lens opacities (61% vs. 69% and 23% vs. 29%, respectively). However, posterior subcapsular lens opacities, were significantly more frequent among ICs (17% vs. 5%, p=0.006), for an OR=3.9 [1.3-11.4]. The risk increased with duration of activity but no clear relationship with workload was observed. However, the risk appeared lower for regular users of protective lead glasses (OR=2.2 [0.4-12.8]). CONCLUSIONS: ICs, in France as elsewhere, are at high risk of posterior subcapsular cataracts. Use of protective equipment against X-rays, in particular lead glasses, is strongly recommended to limit this risk.


Assuntos
Cardiologia , Catarata/epidemiologia , Exposição Ocupacional/prevenção & controle , Médicos , Lesões por Radiação/epidemiologia , Adulto , Cardiologia/normas , Catarata/diagnóstico , Catarata/etiologia , Estudos Transversais , Feminino , França/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Exposição Ocupacional/efeitos adversos , Médicos/normas , Lesões por Radiação/diagnóstico , Lesões por Radiação/etiologia , Fatores de Risco
15.
Radiat Prot Dosimetry ; 153(3): 282-93, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22764175

RESUMO

Radiation dose to the eye lens is a crucial issue for interventional cardiologists (ICs) who are exposed during the procedures they perform. This paper presents a retrospective assessment of the cumulative eye lens doses of ICs enrolled in the O'CLOC study for Occupational Cataracts and Lens Opacities in interventional Cardiology. Information on the workload in the catheterisation laboratory, radiation protection equipment, eye lens dose per procedure and dose reduction factors associated with eye-protective equipment were considered. For the 129 ICs at an average age of 51 who had worked for an average period of 22 years, the estimated cumulative eye lens dose ranged from 25 mSv to more than 1600 mSv; the mean ± SD was 423 ± 359 mSv. After several years of practice, without eye protection, ICs may exceed the new ICRP lifetime eye dose threshold of 500 mSv and be at high risk of developing early radiation-induced cataracts. Radiation protection equipment can reduce these doses and should be used routinely.


Assuntos
Catarata/etiologia , Cristalino/efeitos da radiação , Exposição Ocupacional , Lesões por Radiação/prevenção & controle , Proteção Radiológica/métodos , Adulto , Idoso , Cardiologia/métodos , Feminino , França , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Estatísticos , Saúde Ocupacional , Médicos , Equipamentos de Proteção , Doses de Radiação , Radiologia Intervencionista/métodos , Radiometria , Estudos Retrospectivos , Inquéritos e Questionários
16.
BMC Public Health ; 10: 537, 2010 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-20825640

RESUMO

BACKGROUND: The eye is well known to be sensitive to clearly high doses (>2 Gy) of ionizing radiation. In recent years, however, cataracts have been observed in populations exposed to lower doses. Interventional cardiologists are repeatedly and acutely exposed to scattered ionizing radiation (X-rays) during the diagnostic and therapeutic procedures they perform. These "low" exposures may cause damage to the lens of the eye and induce early cataracts, known as radiation-induced cataracts. The O'CLOC study (Occupational Cataracts and Lens Opacities in interventional Cardiology) was designed to test the hypothesis that interventional cardiologists, compared with an unexposed reference group of non-interventional cardiologists, have an increased risk of cataracts. METHOD/DESIGN: The O'CLOC study is a cross-sectional study that will include a total of 300 cardiologists aged at least 40 years: one group of exposed interventional cardiologists and another of non-interventional cardiologists. The groups will be matched for age and sex. Individual information, including risk factors for cataracts (age, diabetes, myopia, etc.), will be collected during a telephone interview. A specific section of the questionnaire for the exposed group focuses on occupational history, including a description of the procedures (type, frequency, radiation protection tool) used. These data will be used to classify subjects into "exposure level" groups according to cumulative dose estimates. Eye examinations for all participants will be performed to detect cataracts, even in the early stages (lens opacities, according to LOCS III, the international standard classification). The analysis will provide an estimation of the cataract risk in interventional cardiology compared with the unexposed reference group, while taking other risk factors into account. An analysis comparing the risks according to level of exposure is also planned. DISCUSSION: This epidemiological study will provide further evidence about the potential risk of radiation-induced cataracts at low doses and contribute to cardiologists' awareness of the importance of radiation protection. TRIAL REGISTRATION: NCT01061463.


Assuntos
Cardiologia , Catarata/etiologia , Exposição Ocupacional , Médicos , Lesões por Radiação , Radiografia/efeitos adversos , Adulto , Catarata/fisiopatologia , Estudos Transversais , Feminino , Humanos , Masculino , Inquéritos e Questionários
17.
EuroIntervention ; 3(5): 593-9, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19608487

RESUMO

AIMS: A tentative evaluation of doses received by patients undergoing international cardiolfgy (IC) procedures was carried out in France in June 2006 by the GACI. A pilot survey was performed aiming at: a) demonstrating the feasibility of the adopted approach towards estimating patient exposure; b) getting a first estimate of national diagnostic reference level (DRL) values; c) gathering experience on data collection in view of nationwide future studies. METHODS AND RESULTS: Nineteen catheterisation laboratories provided data on 813 IC procedures (496 coronarography (CA) and 317 PTCA) performed by 60 cardiologists on 29 different installations. Data gathered for each procedure were: patient characteristics, dosimetry indicators (DosexArea Product, fluoroscopy time, number of frames) and examination details (number of severe lesions, number of stents, etc.). In spite of their overall compliance with international DRL values, dosimetric indicators showed large variations. Maximum to minimum ratios ranged from 60 to 160 for the DAP, from 80 to 60 for the fluoroscopy time and from 25 to 30 for the number of images for CA and PTCA respectively. CONCLUSION: Findings highlighted key aspects of IC practice which should be improved from the radiation protection point of view: training of cardiologists, awareness of equipment performance and optimisation of procedures.

18.
Chest ; 132(4): 1233-8, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17890474

RESUMO

OBJECTIVE: To determine the radiation exposure associated with CT scans in a population of patients with cystic fibrosis (CF). METHODS: We reviewed the medical charts of patients with typical CF who received regular medical management in a reference center from birth to March 31, 2004. RESULTS: Among 80 patients with a total follow-up time of 1,231 person-years, 79 patients received a total of 269 CT scans, including 249 thoracic CT scans. The full parameters of the examination were available for 185 thoracic CT scans, allowing the effective dose (ED) and organ doses to be calculated. The ED was determined by the number of slices and the type of CT scans. The ED per thoracic CT scan was asymmetrically distributed (mean ED, 6.5 mSv; range 1.5 to 29.3 mSv). The mean doses delivered to the four most strongly exposed organs (lungs, breasts, bone marrow, and thyroid gland) were 18.6, 16.9, 5.2, and 3.5 mGy, respectively. The mean lifetime number of CT scans per patient was 3.2 (range, 0 to 13 scans), and the average lifetime ED was 19.5 mSv per patient (range, 2.2 to 75.8 mSv). Age at the first CT scan fell over the years, from 20 years for patients born before 1980 to 1.9 years for patients born after 1997. CONCLUSION: The mean ED per CT scan in CF patients is about 6.5 mSv. Age at the first CT scan is lower in the most recent generation of patients. The lifetime ED of radiation received by CF patients, especially in the most recent generation, warrants long-term follow-up.


Assuntos
Fibrose Cística/diagnóstico por imagem , Radiografia Torácica , Adulto , Medula Óssea/diagnóstico por imagem , Feminino , Humanos , Fígado/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Masculino , Mamografia , Doses de Radiação , Estudos Retrospectivos , Glândula Tireoide/diagnóstico por imagem , Tomografia Computadorizada por Raios X
19.
Pediatrics ; 117(3): 882-8, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16510671

RESUMO

OBJECTIVE: We sought to determine the number and distribution of radiographs and the cumulative effective radiograph doses (cED) received by a population of preterm infants (PIs) hospitalized in an NICU. STUDY DESIGN: We reviewed the files of all preterm infants (gestational age: <34 weeks) who were admitted to an NICU during an 18-month period and were discharged alive. A generalized additive model was used to study the relationship between cED and patient characteristics. RESULTS: Four hundred fifty files were analyzed. The median gestational age was 30.1 weeks (range: 24.1-33.9 weeks), and the median birth weight was 1250 g (range: 520-2760 g). The median number of radiographs per infant was 10.6 (range: 0-95), and the median cED was 138 microSv (range: 0-1450 microSv). The cumulative dose exceeded 500 microSv in 7.6% of the cases. Factors that influenced the cumulative effective dose were gestational age, birth weight, care procedures, and clinical adverse events. CONCLUSIONS: Given the potentially life-threatening complications of PIs, cumulative radiograph doses received in the ICU seem low with regard to environmental exposure and international recommendations. Additional studies are needed to evaluate the possible lifetime consequences of exposure to ionizing radiation at this age.


Assuntos
Recém-Nascido Prematuro , Radiografia , Peso ao Nascer , Humanos , Recém-Nascido , Unidades de Terapia Intensiva Neonatal , Doses de Radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA