Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 639
Filtrar
1.
Ann Thorac Surg ; 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38972369

RESUMO

BACKGROUND: Perioperative blood transfusion is associated with adverse outcomes and higher costs following coronary artery bypass graft surgery (CABG). We developed risk assessments for patients' probability of perioperative transfusion and the expected transfusion volume, to improve clinical management and resource use. METHODS: Among 1,266,545 consecutive (2008-2016) isolated-CABG operations in STS's Adult Cardiac Surgery Database, 657,821 (51.9%) received perioperative blood transfusions (red blood cell [RBC], fresh frozen plasma [FFP], cryoprecipitate, and/or platelets). We developed "full" models to predict perioperative transfusion of any blood product, and of RBC, FFP, or platelets. Using least absolute shrinkage and selection operator model selection, we built a rapid risk score based on 5 variables (age, body surface area, sex, preoperative hematocrit and use of intra-aortic balloon pump). RESULTS: Full model C-statistics were 0.785, 0.815, 0.707, and 0.699 for any blood product, RBC, FFP, and platelets. Rapid risk assessments' C-statistics were 0.752, 0.785, 0.670, and 0.661 for any blood product, RBC, FFP, and platelets. The observed versus expected risk plots showed strong calibration for full models and risk assessment tools; absolute differences between observed and expected risks of transfusion were <10.8% in each percentile of expected risk. Risk-assessments' predicted probabilities of transfusion were strongly and non-linearly associated (p<.0001) with total units transfused. CONCLUSIONS: These robust and well-calibrated risk assessment tools for perioperative transfusion in CABG can inform surgeons regarding patients' risks and number of RBC, FFP, and platelets units they can expect to need. This can aid in optimizing outcomes and increasing efficient use of blood products.

2.
Am J Cardiol ; 225: 171-177, 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38897265

RESUMO

Severe tricuspid regurgitation remains largely undertreated given limited treatment options. Transcatheter tricuspid valve interventions have emerged as a promising therapy for these patients, and the TRISCEND II pivotal trial is the first randomized controlled trial to evaluate transcatheter tricuspid valve replacement (TTVR). The TRISCEND II pivotal trial studies the transcatheter EVOQUE (Edwards Lifesciences, Irvine, California) tricuspid valve replacement system using a United States Food and Drug Administration Breakthrough Device Designation-a program intended to provide timely access to medical devices by speeding up development, assessment, and review. The TRISCEND II trial is a prospective, multicenter trial that randomizes patients with symptomatic severe tricuspid regurgitation to treatment with either TTVR in conjunction with optimal medical therapy or optimal medical therapy alone. The trial's novel 2-phase design evaluates 30-day safety and 6-month effectiveness end points for the first 150 patients in the initial phase and a 1-year safety and effectiveness end point for the full cohort of 400 patients in the second phase. The TRISCEND II trial's 2-phase trial design provided an opportunity for early review and led to the first commercial approval of a TTVR system. In conclusion, the design of the TRISCEND II trial will likely inform future transcatheter tricuspid device trials.

3.
JACC Adv ; 3(3): 100853, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38938841

RESUMO

Background: Low stroke volume index <35 ml/m2 despite preserved ejection fraction (paradoxical low flow [PLF]) is associated with adverse outcomes in patients with aortic stenosis undergoing transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR). However, whether the risk associated with PLF is similar in both sexes is unknown. Objectives: The purpose of this study was to analyze the risk associated with PLF in severe aortic stenosis for men and women randomized to TAVR or SAVR. Methods: Patients with ejection fraction ≥50% from the PARTNER (Placement of Aortic Transcatheter Valves) 2 and 3 trials were stratified by sex and treatment arm. The impact of PLF on the 2-year occurrence of the composite of death or heart failure hospitalization (primary endpoint) and of all-cause mortality alone (secondary endpoint) was analyzed. Analysis of variance was used to assess baseline differences between groups. Multivariate Cox regression analysis was used to identify predictors of the endpoint. Results: Out of 2,242 patients, PLF was present in 390 men and 239 women (30% vs 26%, P = 0.06). PLF was associated with a higher rate of NYHA functional class III to IV dyspnea (60% vs 54%, P < 0.001) and a higher prevalence of atrial fibrillation (39% vs 24%, P < 0.001). PLF was a significant predictor of the primary endpoint among women undergoing SAVR in multivariate analysis (adjusted HR: 2.25 [95% CI: 1.14-4.43], P = 0.02) but was not associated with a worse outcome in any of the other groups (all P > 0.05). Conclusions: In women with PLF, TAVR may improve outcomes compared to SAVR. PLF appears to have less impact on outcomes in men.

4.
Proc (Bayl Univ Med Cent) ; 37(4): 569-575, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38910820

RESUMO

Background: Among patients with bicuspid aortic valves (BAV) who are potential candidates for valve-sparing root replacement (VSRR), the long-term durability of this technique is not well understood. This study aimed to compare the clinical and echocardiographic outcomes of VSRR in those with BAV and tricuspid aortic valve (TAV) morphology. Methods: This was a retrospective analysis of patients who underwent VSRR between 2007 and 2021 at a single center. Kaplan-Meier and log-rank analysis were used to estimate and compare freedom from mortality, progression to >2+ aortic insufficiency (AI), and reoperation between groups (BAV vs TAV). Preoperative and postoperative echocardiographic data were collected and assessed for temporal changes in mixed-effect models. Results: A total of 185 patients (BAV, n = 52, 28.1%; TAV, n = 133, 71.9%) underwent VSRR. At baseline, BAV patients were younger (42.4 ± 11.6 vs 52.3 ± 12.6 years; P < 0.01) and had more severe AI (47.9% vs 27.0%; P = 0.02). Average cardiopulmonary bypass and cross-clamp times were similar. There were no differences in rates of postoperative complications, intensive care unit or hospital days, or 30-day readmission. TAV patients' 1-, 5-, and 8-year survival rates were 99.2% [95% CI 97.8-100], 96.7% [93.5-99.9%], and 92.2% [85.6-99.3%], respectively. Overall, there were no differences between groups regarding freedom from mortality (P = 0.18), reoperation (P = 0.51), or recurrent >2+ AI (P = 0.97). . Conclusions: VSRR can be safely performed on patients with BAV and TAV morphology, yielding similar midterm freedom from mortality, recurrent >2+ AI, and reoperation. This technique should be considered in carefully selected patients with aortic root pathology and BAV anatomy when performed at experienced centers.

5.
JACC Cardiovasc Interv ; 17(11): 1325-1336, 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38866455

RESUMO

BACKGROUND: Conduction disturbances requiring a permanent pacemaker (PPM) are a frequent complication of transcatheter aortic valve replacement (TAVR) with few reports of rates, predictors, and long-term clinical outcomes following implantation of the third-generation, balloon-expandable SAPIEN 3 (S3) transcatheter heart valve (THV). OBJECTIVES: The aim of this study was to investigate the rates, predictors, and long-term clinical outcomes of PPM implantation following TAVR with the S3 THV. METHODS: The current study included 857 patients in the PARTNER 2 S3 registries with intermediate and high surgical risk without prior PPM, and investigated predictors and 5-year clinical outcomes of new PPM implanted within 30 days of TAVR. RESULTS: Among 857 patients, 107 patients (12.5%) received a new PPM within 30 days after TAVR. By multivariable analysis, predictors of PPM included increased age, pre-existing right bundle branch block, larger THV size, greater THV oversizing, moderate or severe annulus calcification, and implantation depth >6 mm. At 5 years (median follow-up 1,682.0 days [min 2.0 days, max 2,283.0 days]), new PPM was not associated with increased rates of all-cause mortality (Adj HR: 1.20; 95% CI: 0.85-1.70; P = 0.30) or repeat hospitalization (Adj HR: 1.22; 95% CI: 0.67-2.21; P = 0.52). Patients with new PPM had a decline in left ventricular ejection fraction at 1 year that persisted at 5 years (55.1 ± 2.55 vs 60.4 ± 0.65; P = 0.02). CONCLUSIONS: PPM was required in 12.5% of patients without prior PPM who underwent TAVR with a SAPIEN 3 valve in the PARTNER 2 S3 registries and was not associated with worse clinical outcomes, including mortality, at 5 years. Modifiable factors that may reduce the PPM rate include bioprosthetic valve oversizing, prosthesis size, and implantation depth.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Estimulação Cardíaca Artificial , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Desenho de Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Substituição da Valva Aórtica Transcateter/instrumentação , Fatores de Risco , Idoso , Fatores de Tempo , Idoso de 80 Anos ou mais , Resultado do Tratamento , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/mortalidade , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Medição de Risco , Arritmias Cardíacas/terapia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/mortalidade , Estados Unidos/epidemiologia
6.
Am J Cardiol ; 223: 7-14, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-38788821

RESUMO

The frequency and effectiveness of repeat mitral valve interventions (RMVI) after transcatheter edge-to-edge repair (TEER) for secondary mitral regurgitation (MR) are unknown. We aimed to examine the rate of and outcomes after RMVI after TEER in the Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients with Functional Mitral Regurgitation (COAPT) trial. Only 3.9% of COAPT trial patients required a repeat mitral valve intervention during 4-year follow-up which was successful in 90% of cases but was associated with an increased rate of heart failure (HF) hospitalizations (HFH). The COAPT trial randomized HF patients with severe secondary MR to TEER with the MitraClip device plus guideline-directed medical therapy (GDMT) versus GDMT alone. We evaluated the characteristics and outcomes of patients who had an RMVI during 4-year follow-up. A MitraClip implant was attempted in 293 patients randomized to TEER+GDMT, 10 of whom underwent an RMVI procedure (9 repeat TEER and 1 surgical mitral valve replacement) after 4 years of follow-up (cumulative incidence 3.90%, 95% confidence interval [CI] 2.08 to 7.08; median 182 days after the initial procedure). Patients with RMVI had larger mitral annular diameters, fewer clips implanted, and were more likely to have ≥3+MR at discharge compared with those without RMVI. Reasons for RMVI included failed index procedure because of difficult transseptal puncture (n = 2) or tamponade (n = 1); residual or recurrent severe MR after an initially successful procedure (n = 5); partial clip detachment (n = 1); and site-assessed mitral stenosis (n = 1). RMVI was successful in 8/10 (80%) patients. Patients who underwent RMVI had higher 4-year rates of HFH but similar mortality compared with those without RMVI. The annualized incidence rates of all HFH in patients who underwent RMVI were 234 events per 100 person-years (95% CI 139 to 395) pre-RMVI and 46 per 100 person-years (95% CI 25 to 86) post-RMVI as compared with 32 events per 100 patient-years (95% CI 28 to 36) in patients without RMVI. The rate ratio of HFH was reduced after RMVI in patients who underwent RMVI (0.20, 95% CI 0.09 to 0.45). In conclusion, the cumulative incidence of RMVI after 4 years was 3.9% in patients who underwent TEER for severe secondary MR in the COAPT trial. Patients who underwent RMVI were at increased risk of HFH which was reduced after the RMVI procedure. Clinical Trial Registration: Clinical Trial Name: Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation (The COAPT Trial) (COAPT) ClinicalTrial.gov Identifier: NCT01626079 URL:https://clinicaltrials.gov/ct2/show/NCT01626079.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Valva Mitral , Humanos , Insuficiência da Valva Mitral/cirurgia , Masculino , Feminino , Idoso , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Seguimentos , Resultado do Tratamento , Idoso de 80 Anos ou mais , Reoperação , Insuficiência Cardíaca/terapia
7.
JAMA Cardiol ; 9(7): 631-639, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38776106

RESUMO

Importance: The use of valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR) has been rapidly expanding as an alternative treatment to redo surgical aortic valve replacement (SAVR) for failed bioprosthetic valves despite limited long-term data. Objective: To assess mortality and morbidity in patients undergoing intervention for failed bioprosthetic SAVR. Design, Setting, and Participants: This was a retrospective population-based cohort analysis conducted between January 1, 2015, and December 31, 2020, with a median (IQR) follow-up time of 2.3 (1.1-4.0) years. A total of 1771 patients with a history of bioprosthetic SAVR who underwent ViV-TAVR or redo SAVR in California, New York, and New Jersey were included. Data were obtained from the California Department of Health Care Access and Information, the New York Statewide Planning and Research Cooperative System, and the New Jersey Discharge Data Collection System. Exclusion criteria included undergoing TAVR or redo SAVR within 5 years from initial SAVR, as well as infective endocarditis, concomitant surgical procedures, and out-of-state residency. Propensity matching yielded 375 patient pairs. Data were analyzed from January to December 2023. Interventions: ViV-TAVR vs redo SAVR. Main Outcomes and Measurements: The primary outcome was all-cause mortality. Secondary outcomes were stroke, heart failure hospitalization, reoperation, major bleeding, acute kidney failure, new pacemaker insertion, and infective endocarditis. Results: From 2015 through 2020, the proportion of patients undergoing ViV-TAVR vs redo SAVR increased from 159 of 451 (35.3%) to 498 or 797 (62.5%). Of 1771 participants, 653 (36.9%) were female, and the mean (SD) age was 74.4 (11.3) years. Periprocedural mortality and stroke rates were similar between propensity-matched groups. The ViV-TAVR group had lower periprocedural rates of major bleeding (2.4% vs 5.1%; P = .05), acute kidney failure (1.3% vs 7.2%; P < .001), and new pacemaker implantations (3.5% vs 10.9%; P < .001). The 5-year all-cause mortality rate was 23.4% (95% CI, 15.7-34.1) in the ViV-TAVR group and 13.3% (95% CI, 9.2-18.9) in the redo SAVR group. In a landmark analysis, no difference in mortality was observed up to 2 years (hazard ratio, 1.03; 95% CI, 0.59-1.78), but after 2 years, ViV-TAVR was associated with higher mortality (hazard ratio, 2.97; 95% CI, 1.18-7.47) as well as with a higher incidence of heart failure hospitalization (hazard ratio, 3.81; 95% CI, 1.57-9.22). There were no differences in 5-year incidence of stroke, reoperation, major bleeding, or infective endocarditis. Conclusions and Relevance: Compared with redo SAVR, ViV-TAVR was associated with a lower incidence of periprocedural complications and a similar incidence of all-cause mortality through 2 years' follow-up. However, ViV-TAVR was associated with higher rates of late mortality and heart failure hospitalization. These findings may be influenced by residual confounding and require adjudication in a randomized clinical trial.


Assuntos
Bioprótese , Reoperação , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Masculino , Idoso , Substituição da Valva Aórtica Transcateter/métodos , Estudos Retrospectivos , Reoperação/estatística & dados numéricos , Idoso de 80 Anos ou mais , Próteses Valvulares Cardíacas , Complicações Pós-Operatórias/epidemiologia , Falha de Prótese , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos
8.
J Am Coll Cardiol ; 83(20): 2002-2014, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38749619

RESUMO

Orthotopic transcatheter tricuspid valve replacement (TTVR) devices have been shown to be highly effective in reducing tricuspid regurgitation (TR), and interest in this therapy is growing with the recent commercial approval of the first orthotopic TTVR. Recent TTVR studies report preexisting cardiac implantable electronic device (CIED) transvalvular leads in ∼35% of patients, with entrapment during valve implantation. Concerns have been raised regarding the safety of entrapping leads and counterbalanced against the risks of transvenous lead extraction (TLE) when indicated. This Heart Valve Collaboratory consensus document attempts to define the patient population with CIED lead-associated or lead-induced TR, describe the risks of lead entrapment during TTVR, delineate the risks and benefits of TLE in this setting, and develop a management algorithm for patients considered for TTVR. An electrophysiologist experienced in CIED management should be part of the multidisciplinary heart team and involved in shared decision making.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/cirurgia , Desfibriladores Implantáveis/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Índice de Gravidade de Doença
9.
Artigo em Inglês | MEDLINE | ID: mdl-38693866

RESUMO

AIMS: Evaluation of left and right ventricular longitudinal systolic function may enhance risk stratification following aortic valve replacement (AVR). The study objective was to evaluate the changes in left and right ventricular longitudinal systolic function and RV-pulmonary artery (RV-PA) coupling from baseline to 30-days and 1-year after aortic valve replacement (AVR). METHODS AND RESULTS: LV longitudinal strain (LS), tricuspid annulus plane systolic excursion (TAPSE), and RV-PA coupling were evaluated in patients from the PARTNER-2A surgical AVR (SAVR) arm (n=985) and from the PARTNER-2 SAPIEN-3 registry (n=719). TAPSE and RV-PA coupling decreased significantly following SAVR, but remained stable following TAVR. Lower LV LS, TAPSE, or RV-PA coupling at baseline were associated with increased risk of the composite of death, hospitalization, and stroke at 5-years (Adjusted-HRs for LV LS<15%: 1.24 95%CI 1.05-1.45, p=0.001; TAPSE<14mm: 1.44 95%CI 1.21-1.73, p<0.001; RV/PA coupling<0.55mm/mmHg: 1.32 95% CI 1.07-1.63, p=0.011). Reduced TAPSE at baseline was the most powerful predictor of the composite endpoint at 5-years. Patients with LV ejection fraction <50% at baseline had increased risk of the primary endpoint with SAVR (HR: 1.34, 95%CI 1.08-1.68, p=0.009) but not with TAVR (HR: 1.12, 95%CI 0.88-1.42). Lower RV-PA coupling at 30-days showed the strongest association with cardiac mortality. CONCLUSION: SAVR but not TAVR was associated with a marked deterioration in RV longitudinal systolic function and RV-PA coupling. Lower TAPSE and RV-PA coupling at 30-days were associated with inferior clinical outcomes at 5-years. In patients with LVEF<50%, TAVR was associated with superior 5-year outcomes.

10.
EuroIntervention ; 20(9): 536-550, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38726720

RESUMO

The identification and management of patients at high bleeding risk (HBR) undergoing transcatheter aortic valve implantation (TAVI) are of major importance, but the lack of standardised definitions is challenging for trial design, data interpretation, and clinical decision-making. The Valve Academic Research Consortium for High Bleeding Risk (VARC-HBR) is a collaboration among leading research organisations, regulatory authorities, and physician-scientists from Europe, the USA, and Asia, with a major focus on TAVI-related bleeding. VARC-HBR is an initiative of the CERC (Cardiovascular European Research Center), aiming to develop a consensus definition of TAVI patients at HBR, based on a systematic review of the available evidence, to provide consistency for future clinical trials, clinical decision-making, and regulatory review. This document represents the first pragmatic approach to a consistent definition of HBR evaluating the safety and effectiveness of procedures, devices and drug regimens for patients undergoing TAVI..


Assuntos
Consenso , Hemorragia , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Fatores de Risco , Hemorragia/etiologia , Medição de Risco , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia
11.
Eur Heart J ; 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38820201

RESUMO

BACKGROUND AND AIMS: Surgical explantation of transcatheter heart valves (THVs) is rapidly increasing, but there are limited data on patients with THV-associated infective endocarditis (IE). This study aims to assess the outcomes of patients undergoing THV explant for IE. METHODS: All patients who underwent THV explant between 2011 and 2022 from 44 sites in the EXPLANT-TAVR registry were identified. Patients with IE as the reason for THV explant were compared to those with other mechanisms of bioprosthetic valve dysfunction (BVD). RESULTS: A total of 372 patients from the EXPLANT-TAVR registry were included. Among them, 184 (49.5%) patients underwent THV explant due to IE and 188 (50.5%) patients due to BVD. At the index transcatheter aortic valve replacement, patients undergoing THV explant for IE were older (74.3 ± 8.6 vs. 71 ± 10.6 years) and had a lower Society of Thoracic Surgeons risk score [2.6% (1.8-5.0) vs. 3.3% (2.1-5.6), P = .029] compared to patients with BVD. Compared to BVD, IE patients had longer intensive care unit and hospital stays (P < .05) and higher stroke rates at 30 days (8.6% vs. 2.9%, P = .032) and 1 year (16.2% vs. 5.2%, P = .010). Adjusted in-hospital, 30-day, and 1-year mortality was 12.1%, 16.1%, and 33.8%, respectively, for the entire cohort, with no significant differences between groups. Although mortality was numerically higher in IE patients 3 years postsurgery (29.6% for BVD vs. 43.9% for IE), Kaplan-Meier analysis showed no significant differences between groups (P = .16). CONCLUSIONS: In the EXPLANT-TAVR registry, patients undergoing THV explant for IE had higher 30-day and 1-year stroke rates and longer intensive care unit and hospital stays. Moreover, patients undergoing THV explant for IE had a higher 3-year mortality rate, which did not reach statistical significance given the relatively small sample size of this unique cohort and the reduced number of events.

12.
Artigo em Inglês | MEDLINE | ID: mdl-38795108

RESUMO

BACKGROUND: Functional mitral regurgitation induces adverse effects on the left ventricle and the left atrium. Left atrial (LA) dilatation and reduced LA strain are associated with poor outcomes in heart failure (HF). Transcatheter edge-to-edge repair (TEER) of the mitral valve reduces heart failure hospitalization (HFH) and all-cause death in selected HF patients. OBJECTIVES: The aim of this study was to evaluate the impact of LA strain improvement 6 months after TEER on the outcomes of patients enrolled in the COAPT (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation) trial. METHODS: The difference in LA strain between baseline and the 6-month follow-up was calculated. Patients with at least a 15% improvement in LA strain were labeled as "LA strain improvers." All-cause death and HFH were assessed between the 6 and 24-month follow-up. RESULTS: Among 347 patients (mean age 71 ± 12 years, 63% male), 106 (30.5%) showed improvement of LA strain at the 6-month follow-up (64 [60.4%] from the TEER + guideline-directed medical therapy [GDMT] group and 42 [39.6%] from the GDMT alone group). An improvement in LA strain was significantly associated with a reduction in the composite of death or HFH between the 6-month and 24-month follow-up, with a similar risk reduction in both treatment arms (Pinteraction = 0.27). In multivariable analyses, LA strain improvement remained independently associated with a lower risk of the primary composite endpoint both as a continuous variable (adjusted HR: 0.94 [95% CI: 0.89-1.00]; P = 0.03) and as a dichotomous variable (adjusted HR: 0.49 [95% CI: 0.27-0.89]; P = 0.02). The best outcomes were observed in patients treated with TEER in whom LA strain improved. CONCLUSIONS: In symptomatic HF patients with severe mitral regurgitation, improved LA strain at the 6-month follow-up is associated with subsequently lower rates of the composite endpoint of all-cause mortality or HFH, both after TEER and GDMT alone. (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation [COAPT]; NCT01626079).

13.
Am J Cardiol ; 220: 67-76, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38582312

RESUMO

Transcatheter tricuspid valve intervention (TTVI) has recently emerged as a promising alternative to surgery for tricuspid regurgitation (TR). However, a significant proportion of patients fail screening for TTVI, and little is known about their characteristics and natural history. This study sought to investigate causes of screen failure and outcomes of patients declined for TTVI. This was a retrospective single-center study of 32 patients who were ineligible for participation in transcatheter tricuspid valve replacement and tricuspid transcatheter edge-to-edge repair trials. Patients were classified into 2 groups according to the therapy they received: optimized medical therapy (OMT) group or intervention group. The mean age was 82 ± 7.8 years and 68.8% were women. The most common reasons for TTVI exclusion were anatomic/procedural impediment (53.1%), inclusion criteria not met (40.6%), and multivalvular disease (6.3%). Overall, 19 patients (59.4%) did not undergo subsequent tricuspid intervention. The clinical outcomes of these patients who received OMT alone were poor, with a 1-year composite of cardiac death or heart failure readmission of 47.4%. These rates were worse than in patients who subsequently underwent an intervention, albeit not statistically significant (OMT: 47.7% vs 23.1% interventions, p = 0.3), and were significantly more pronounced in the subgroup of patients who were excluded for anatomic/procedural limitations (OMT: 70% vs 14.3% interventions, p = 0.05). In conclusion, patients ineligible for TTVI, particularly, those with anatomic/procedural limitations, and treated medically have poor outcomes. These data underscore the importance of earlier referral and support the need for further transcatheter therapy iterations.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Valva Tricúspide , Humanos , Feminino , Masculino , Estudos Retrospectivos , Insuficiência da Valva Tricúspide/cirurgia , Cateterismo Cardíaco/métodos , Idoso de 80 Anos ou mais , Valva Tricúspide/cirurgia , Valva Tricúspide/diagnóstico por imagem , Implante de Prótese de Valva Cardíaca/métodos , Idoso , Resultado do Tratamento , Seguimentos , Programas de Rastreamento/métodos
14.
J Am Heart Assoc ; 13(8): e032276, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38563386

RESUMO

BACKGROUND: Recently, machine learning algorithms have identified preprocedural γ-glutamyl transferase (GGT) as a significant predictor of long-term mortality after coronary revascularization in the SYNTAX (Synergy Between PCI [Percutaneous Coronary Intervention] With Taxus and Cardiac Surgery) trial. The aim of the present study is to investigate the impact of preprocedural GGT on 10-year all-cause mortality in patients with complex coronary artery disease after revascularization. METHODS AND RESULTS: The SYNTAX trial was a randomized trial comparing PCI with coronary artery bypass grafting in 1800 patients with complex coronary artery disease. The present report is a post hoc subanalysis of the SYNTAXES (Synergy Between PCI With Taxus and Cardiac Surgery Extended Survival) trial, an investigator-driven extended 10-year follow-up of the SYNTAX trial. The association between preprocedural GGT and 10-year all-cause mortality was investigated. The mean values of GGT for men and women were 43.5 (SD, 48.5) and 36.4 (SD, 46.1) U/L, respectively. In multivariable Cox regression models adjusted by traditional risk factors, GGT was an independent predictor for all-cause death at 10-year follow-up, and each SD increase in log-GGT was associated with a 1.24-fold risk of all cause death at 10-year follow-up (95% CI, 1.10-1.40). According to previously reported sex-related GGT thresholds, patients with higher GGT level had a 1.74-fold risk of all-cause death at 10-year follow-up (95% CI, 1.32-2.29) compared with patients with lower GGT level. CONCLUSIONS: Preprocedural GGT is an independent predictor of 10-year mortality after coronary revascularization in patients with complex coronary artery disease. In patients with elevated GGT, strong secondary prevention may be required after revascularization and must be studied prospectively. REGISTRATION: URL: https://clinicaltrials.gov/study/NCT03417050.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Masculino , Humanos , Feminino , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , gama-Glutamiltransferase , Resultado do Tratamento , Fatores de Risco , Fígado
16.
JACC Clin Electrophysiol ; 10(5): 930-940, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38661602

RESUMO

BACKGROUND: Postoperative atrial fibrillation (POAF) is associated with increased morbidity and mortality. Epicardial injection of botulinum toxin may suppress POAF. OBJECTIVES: This study sought to assess the safety and efficacy of AGN-151607 for the prevention of POAF after cardiac surgery. METHODS: This phase 2, randomized, placebo-controlled trial assessed the safety and efficacy of AGN-151607, 125 U and 250 U vs placebo (1:1:1), for the prevention of POAF after cardiac surgery. Randomization was stratified by age (<65, ≥65 years) and type of surgery (nonvalvular/valve surgery). The primary endpoint was the occurrence of continuous AF ≥30 seconds. RESULTS: Among 312 modified intention-to-treat participants (placebo, n = 102; 125 U, n = 104; and 250 U, n = 106), the mean age was 66.9 ± 6.8 years; 17% were female; and 64% had coronary artery bypass graft (CABG) only, 12% had CABG + valve, and 24% had valve surgery. The primary endpoint occurred in 46.1% of the placebo group, 36.5% of the 125-U group (relative risk [RR] vs placebo: 0.80; 95% CI: 0.58-1.10; P = 0.16), and 47.2% of the 250-U group (RR vs placebo: 1.04; 95% CI: 0.79-1.37; P = 0.78). The primary endpoint was reduced in the 125-U group in those ≥65 years of age (RR: 0.64; 95% CI: 0.43-0.94; P = 0.02) with a greater reduction in CABG-only participants ≥65 years of age (RR: 0.49; 95% CI: 0.27-0.87; P = 0.01). Rehospitalization and rates of adverse events were similar across the 3 groups. CONCLUSIONS: There were no significant differences in the rate of POAF with either dose compared with placebo; however, there was a lower rate of POAF in participants ≥65 years undergoing CABG only and receiving 125 U of AGN-151607. These hypothesis-generating findings require investigation in a larger, adequately powered randomized clinical trial. (Botulinum Toxin Type A [AGN-151607] for the Prevention of Post-operative Atrial Fibrillation in Adult Participants Undergoing Open-chest Cardiac Surgery [NOVA]; NCT03779841); A Phase 2, Multi-Center, Randomized, Double-Blind, Placebo-Controlled, Dose Ranging Study to Evaluate the Efficacy and Safety of Botulinum Toxin Type A [AGN 151607] Injections into the Epicardial Fat Pads to Prevent Post-Operative Atrial Fibrillation in Patients Undergoing Open-Chest Cardiac Surgery; 2017-004399-68).


Assuntos
Fibrilação Atrial , Toxinas Botulínicas Tipo A , Complicações Pós-Operatórias , Humanos , Fibrilação Atrial/prevenção & controle , Feminino , Masculino , Idoso , Toxinas Botulínicas Tipo A/uso terapêutico , Toxinas Botulínicas Tipo A/administração & dosagem , Pessoa de Meia-Idade , Complicações Pós-Operatórias/prevenção & controle , Método Duplo-Cego , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Resultado do Tratamento , Ponte de Artéria Coronária/efeitos adversos
17.
Am J Cardiol ; 220: 102-110, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38432334

RESUMO

Proximal radial artery (PRA) access for cardiac catheterization is safe but can jeopardize subsequent use of the artery because of occlusion. Distal radial artery (DRA) access in the anatomical snuffbox preserves the RA but safety and potential detrimental effects on hand function are unknown. We aimed to assess hand function and complications after DRA and PRA. In this single-center trial, 300 patients were randomly allocated 1:1 to cardiac catheterization through DRA or PRA. The primary end point of change in hand function from baseline to 1 year was a composite of the Quick Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire, hand grip test, and thumb-forefinger pinch test. The secondary end points included access feasibility and complications. Of 216 patients with 1-year completed follow-up, 112 were randomly allocated to DRA and 104 to PRA, with balanced demographics and procedural characteristics. Both groups had similar access site bleeding rates (DRA 0% vs PRA 1.4%, p = 0.25). Radial artery occlusion occurred in 1 PRA patient versus 2 in DRA. There was no significant difference in change of hand function, median (interquartile range) hand grip (DRA 0.7 [-3 to 4.5] vs PRA 1.3 [-2 to 4.3] kg, p = 0.57), pinch grip (DRA -0.1 [-1.1 to 1] vs PRA -0.3 [-1 to 0.7] kg, p = 0.66), and Quick DASH (DRA 0 [-6.6 to 2.3] vs PRA 0 [-4.6 to 2.9] points, p = 0.58). The composite of hand function was comparable between PRA and DRA. In conclusion, DRA is a safe strategy for cardiac catheterization, with a low complication rate. Compared with PRA, there is no increased risk of hand dysfunction or radial artery occlusion at 1 year.


Assuntos
Cateterismo Cardíaco , Artéria Radial , Humanos , Masculino , Feminino , Cateterismo Cardíaco/métodos , Pessoa de Meia-Idade , Idoso , Força da Mão/fisiologia , Seguimentos , Fatores de Tempo
18.
Circ Cardiovasc Interv ; 17(4): e013581, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38436084

RESUMO

BACKGROUND: Transcatheter edge-to-edge mitral valve (MV) repair (TEER) is an effective treatment for patients with primary mitral regurgitation at prohibitive risk for surgical MV repair (MVr). High-volume MVr centers and high-volume TEER centers have better outcomes than low-volume centers, respectively. However, whether MVr volume predicts TEER outcomes remains unknown. We hypothesized that high-volume MV surgical centers would have superior risk-adjusted outcomes for TEER than low-volume centers. METHODS: We combined data from the American College of Cardiology/Society of Thoracic Surgeons Transcatheter Valve Therapy registry and the Society of Thoracic Surgeons adult cardiac surgery database. MVr was defined as leaflet resection or artificial chords with or without annuloplasty and was evaluated as a continuous variable and as predefined categories (<25, 25-49, and ≥50 MV repairs/year). A generalized linear mixed model was used to evaluate risk-adjusted in-hospital/30-day mortality, 30-day heart failure readmission, and TEER success (mitral regurgitation ≤2+ and gradient <5 mm Hg). RESULTS: The study comprised 41 834 patients from 500 sites of which 332 (66.4%) were low, 102 (20.4%) intermediate, and 66 (13.2%) high-volume surgical centers (P<0.001). TEER success was 54.6% and was not statistically significantly different across MV surgical site volumes (P=0.4271). TEER mortality at 30 days was 3.5% with no significant difference across MVr volume on unadjusted (P=0.141) or adjusted (P=0.071) analysis of volume as a continuous variable. One-year mortality was 15.0% and was lower for higher MVr volume centers when adjusted for clinical and demographic variables (P=0.027). Heart failure readmission at 1 year was 9.4% and was statistically significantly lower in high-volume centers on both unadjusted (P=0.017) or adjusted (P=0.015) analysis. CONCLUSIONS: TEER can be safely performed in centers with low volumes of MV repair. However, 1-year mortality and heart failure readmission are superior at centers with higher MVr volume.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Resultado do Tratamento , Insuficiência Cardíaca/etiologia , Hospitais
19.
Proc (Bayl Univ Med Cent) ; 37(2): 205-209, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38343487

RESUMO

Background: Conduction abnormality requiring the implantation of a permanent pacemaker (PPM) is a well-known and clinically important complication of transcatheter aortic valve replacement (TAVR). However, PPM implantation may result in lead-associated tricuspid valve regurgitation (TR). This study sought to determine the incidence and progression of TR following PPM implantation after TAVR. Methods: This was a retrospective review of all echocardiograms of patients who underwent PPM following TAVR at the Baylor Scott & White hospitals from 2012 to 2021. The primary endpoint was TR progression at 30 days and 1 year. A subanalysis comparing the change in TR progression between small and large TAVR devices was also conducted. Secondary outcomes included all-cause death at 30 days and 1 year. Results: Out of the 2744 patients who underwent TAVR between April 2012 and August 2021, 177 patients (6.5%) subsequently received a new PPM. There was a statistically significant progression of TR at 1-year follow-up (McNemar's P value = 0.02). TR progression rates were comparable between the small and large valve groups at 1-year follow-up (4% vs 11%, P = 0.09, respectively). Conclusion: In this single healthcare system study, we demonstrated a significant progression of TR in patients with PPM post TAVR at 1 year.

20.
Proc (Bayl Univ Med Cent) ; 37(2): 218-226, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38343489

RESUMO

Background: In March 2022, a COVID-19 outbreak disrupted the global supply of iodine contrast media (ICM). Healthcare systems implemented contrast-saving strategies to maintain their remaining ICM supplies. This study sought to determine the impact of contrast shortage on the incidence of contrast-associated acute kidney injury (CA-AKI). Methods: This was a retrospective study of 265 patients undergoing 278 percutaneous coronary interventions (PCI) during 4-month periods prior to (9/1/2021 to 12/31/2021) and during (5/1/2022 to 8/31/2022) contrast shortage at a single center. The primary endpoint was the incidence of CA-AKI between study periods. Results: A total of 148 and 130 PCIs were performed before and during contrast shortage, respectively. The incidence of CA-AKI significantly decreased from 11.5% to 4.6% during contrast shortage (P = 0.04). During the shortage, average contrast volume per PCI was significantly lower (123 ± 62 mL vs 88 ± 46 mL, P < 0.001), while coronary imaging was significantly higher (34.3% vs 50%, P = 0.009) compared to preshortage. All-cause mortality at discharge was comparable between study periods (2.8% vs 3.3%, respectively; P = 0.90). Conclusion: The scarcity of ICM for PCI procedures in this single-center experience was associated with a significant increase in the utilization of intravascular imaging and a significant reduction in CA-AKI.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA