Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Environ Geochem Health ; 46(6): 201, 2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38696114

RESUMO

The study's objective was to determine the air quality in an asbestos-related industry and its impact on current workers' respiratory health. Seventy-seven air and 65 dust samples were collected at 5-day intervals in an asbestos roofing sheets production factory in Sri Lanka having two production facilities. Sampling was performed in ten sites: Defective sheets-storage, Production-plant, Pulverizer, Cement-silo, and Loading-area. A detailed questionnaire and medical screening were conducted on 264 workers, including Lung Function Tests (LFT) and chest X-rays. Asbestos fibres were observed in deposited dust samples collected from seven sites. Free chrysotile fibres were absent in the breathing air samples. Scanning Electron Microscopy confirmed the presence of asbestos fibres, and the Energy Dispersive X-ray analysis revealed Mg, O, and Si in depositions. The average concentrations of trace metals were Cd-2.74, Pb-17.18, Ni-46.68, Cr-81.01, As-7.12, Co-6.77, and Cu-43.04 mg/kg. The average Zn, Al, Mg, and Fe concentrations were within 0.2-163 g/kg. The highest concentrations of PM2.52.5 and PM1010, 258 and 387 µg/m3, respectively, were observed in the Pulverizer site. Forty-four workers had respiratory symptoms, 64 presented LFT abnormalities, 5 indicated chest irregularities, 35.98% were smokers, and 37.5% of workers with abnormal LFT results were smokers. The correlation coefficients between LFT results and work duration with respiratory symptoms and work duration and chest X-ray results were 0.022 and 0.011, respectively. In conclusion, most pulmonary disorders observed cannot directly correlate to Asbestos exposure due to negligible fibres in breathing air, but fibres in the depositions and dust can influence the pulmonary health of the employees.


Assuntos
Amianto , Exposição Ocupacional , Humanos , Sri Lanka , Exposição Ocupacional/análise , Amianto/análise , Masculino , Pessoa de Meia-Idade , Adulto , Poluentes Ocupacionais do Ar/análise , Poeira/análise , Testes de Função Respiratória , Monitoramento Ambiental/métodos , Feminino , Indústria Manufatureira
2.
Biomed Res Int ; 2019: 7393926, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31309114

RESUMO

Nosocomial infections, in lay term known as hospital acquired infections, are caused mainly by airborne pathogens found in healthcare facilities and their surroundings. The aim of this study was to quantify and identify bacteria and fungi in a hospital, which is an understudied area of air quality in Sri Lanka. Air samples were collected in agar medium and petri plates containing sterile filter papers. The number of culturable and total airborne microorganisms was estimated by manual counting and fluorescent microscopy, respectively. The morphologically distant bacteria and fungi were identified by DNA sequencing. The statistical analysis revealed significant variances between studied sites (p < 0.05) where Outpatients Department and Respiratory Unit showed higher levels of airborne microbial load. Culturable microbial count was higher at noon (hospital visiting hours) compared to other sampling periods (after hospital visiting hours) within the hospital. Total count of airborne microbes was found to be the highest during the afternoon. The most sensitive zones such as Operating Theatre and Intensive Care Unit showed considerably higher counts of airborne microbes. Identification by molecular means revealed the presence of human pathogens in the hospital air including Bacillus sp, Micrococcus sp, Pseudomonas sp, Staphylococcu ssp, Exiguobacterium sp, Enterobacter sp, Escherichia sp, Sphingomonas sp, Massilia sp, Kocuria sp, Fusarium sp, and Aspergillus sp. In conclusion, the results from this study indicate that the hospital air was generally contaminated. Therefore, the implementation of proactive policies and strategies are needed to monitor hospital air quality in sensitive zones as well as other areas of the hospitals.


Assuntos
Poluição do Ar em Ambientes Fechados , Bactérias , Infecção Hospitalar/microbiologia , Fungos , Hospitais de Ensino , Micobioma , Bactérias/classificação , Bactérias/isolamento & purificação , Contagem de Colônia Microbiana , Fungos/classificação , Fungos/isolamento & purificação , Humanos , Sri Lanka
3.
Indian J Chest Dis Allied Sci ; 55(2): 113-5, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24047003

RESUMO

Extra-pulmonary diseases may mimic pulmonary lesions on chest radiography. We report a case of a silent rupture of an atherosclerotic thoracic aortic aneurysm with peripheral thrombus formation, that closely mimicked a complicated lung malignancy.


Assuntos
Aneurisma Aórtico/diagnóstico , Ruptura Aórtica/diagnóstico , Neoplasias Pulmonares/diagnóstico , Aneurisma Aórtico/diagnóstico por imagem , Ruptura Aórtica/diagnóstico por imagem , Diagnóstico Diferencial , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Radiografia Torácica , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA