Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Magn Reson Med ; 88(4): 1912-1926, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35766426

RESUMO

PURPOSE: To improve whole-brain SNR at 7 Tesla, a novel 32-element hybrid human head array coil was developed, constructed, and tested. METHODS: Our general design strategy is based on 2 major ideas: Firstly, following suggestions of previous works based on the ultimate intrinsic SNR theory, we combined loops and dipoles for improvement of SNR near the head center. Secondly, we minimized the total number of array elements by using a hybrid combination of transceive (TxRx) and receive (Rx) elements. The new hybrid array consisted of 8 folded-end TxRx-dipole antennas and 3 rows of 24 Rx-loops all placed in a single layer on the surface of a tight-fit helmet. RESULTS: The developed array significantly improved SNR in vivo both near the center (∼20%) and at the periphery (∼20% to 80%) in comparison to a common commercial array coil with 8 transmit (Tx) and 32 Rx-elements. Whereas 24 loops alone delivered central SNR very similar to that of the commercial coil, the addition of complementary dipole structures provided further improvement. The new array also provided ∼15% higher Tx efficiency and better longitudinal coverage than that of the commercial array. CONCLUSION: The developed array coil demonstrated advantages in combining complementary TxRx and Rx resonant structures, that is, TxRx-dipoles and Rx-loops all placed in a single layer at the same distance to the head. This strategy improved both SNR and Tx-performance, as well as simplified the total head coil design, making it more robust.


Assuntos
Aumento da Imagem , Imageamento por Ressonância Magnética , Desenho de Equipamento , Humanos , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Razão Sinal-Ruído
2.
NMR Biomed ; 35(10): e4773, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35580922

RESUMO

Important issues in designing radiofrequency (RF) coils for human head imaging at ultra-high field (UHF; ≥7 T) are the inhomogeneity and longitudinal coverage (along the magnet axis) of the transmit (Tx) RF field. Both the homogeneity and coverage produced by Tx volume coils can be improved by means of three-dimensional (3D) RF shimming, which requires the use of multirow Tx-arrays. In addition, according to recent findings of the ultimate intrinsic signal-to-noise ratio (UISNR) theory, the loop-only receive (Rx) arrays do not provide optimal SNR near the brain center at UHF. The latter can be obtained by combining complementary conductive structures carrying different current patterns (e.g., loops and dipole antennas). In this work, we developed, constructed, and evaluated a novel 32-element hybrid array design for human head imaging at 7 T. The array consists of 16 transceiver loops placed in two rows circumscribing the head and 16 folded-end Rx-only dipoles positioned in the centers of loops. By placing all elements in a single layer, we increased RF power deposition into the tissue and, thus, preserved the Tx-efficiency. Using this hybrid design also simplifies the coil structure by minimizing the total number of array elements. The array demonstrated whole brain coverage, 3D RF shimming capability, and high SNR. It provided ~15% higher SNR near the brain center and, depending on the RF shim mode, from 20% to 40% higher Tx-efficiency than a common commercial head array coil.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Encéfalo/diagnóstico por imagem , Desenho de Equipamento , Humanos , Imageamento por Ressonância Magnética/métodos , Neuroimagem , Imagens de Fantasmas , Razão Sinal-Ruído
3.
J Magn Reson ; 331: 107052, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34478997

RESUMO

Diffusion-weighted imaging (DWI) in the female breast is a magnetic resonance imaging (MRI) technique that complements clinical routine protocols, and that might provide an independent diagnostic value for specific clinical tasks in breast imaging. To further improve specificity of DWI in the breast, stronger and faster diffusion weighting is advantageous. Here, a dedicated gradient coil is designed, targeted at diffusion weighting in the female breast, with the peak gradient magnitude exceeding that of the current clinical MR scanners by an order of a magnitude. Design of application-tailored gradient coils in MRI has recently attracted increased attention. With the target application in mind, the gradient coil is designed on an irregularly shaped semi-open current-carrying surface. Due to the coil former closely fitting the non-spherical target region, non-linear encoding fields become particularly advantageous for achieving locally exceptionally high gradient strengths. As breast tissue has a predominantly isotropic cellular microstructure, the direction of the diffusion-weighting gradient may be allowed to vary within the target volume. However, due to the quadratic dependency of the b-factor on the gradient strength, variation of the gradient magnitude should be carefully controlled. To achieve the above design goals the corresponding multi-objective optimization problem is reformulated as a constrained optimization, allowing for flexible and precise control of the coil properties. A novel constraint is proposed, limiting gradient magnitude variation within every slice while allowing for variations in both the direction of the gradient within the slice and the magnitude across the slices. These innovations enable the design of a unilateral coil for diffusion weighting in the female breast with local gradient strengths exceeding 1 T/m with highly homogeneous diffusion weighting for imaging in the coronal slice orientation.


Assuntos
Imagem de Difusão por Ressonância Magnética , Imageamento por Ressonância Magnética , Mama/diagnóstico por imagem , Difusão , Feminino , Humanos
4.
Magn Reson Med ; 86(5): 2412-2425, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34061397

RESUMO

PURPOSE: To develop a framework for 3D sodium (23 Na) MR fingerprinting (MRF), based on irreducible spherical tensor operators with tailored flip angle (FA) pattern and time-efficient data acquisition for simultaneous quantification of T1 , T2l∗ , T2s∗ , and T2∗ in addition to ΔB0 . METHODS: 23 Na-MRF was implemented in a 3D sequence and irreducible spherical tensor operators were exploited in the simulations. Furthermore, the Cramér Rao lower bound was used to optimize the flip angle pattern. A combination of single and double echo readouts was implemented to increase the readout efficiency. A study was conducted to compare results in a multicompartment phantom acquired with MRF and reference methods. Finally, the relaxation times in the human brain were measured in four healthy volunteers. RESULTS: Phantom experiments revealed a mean difference of 1.0% between relaxation times acquired with MRF and results determined with the reference methods. Simultaneous quantification of the longitudinal and transverse relaxation times in the human brain was possible within 32 min using 3D 23 Na-MRF with a nominal resolution of (5 mm)3 . In vivo measurements in four volunteers yielded average relaxation times of: T1,brain = (35.0 ± 3.2) ms, T2l,brain∗ = (29.3 ± 3.8) ms and T2s,brain∗ = (5.5 ± 1.3) ms in brain tissue, whereas T1,CSF = (61.9 ± 2.8) ms and T2,CSF∗ = (46.3 ± 4.5) ms was found in cerebrospinal fluid. CONCLUSION: The feasibility of in vivo 3D relaxometric sodium mapping within roughly ½ h is demonstrated using MRF in the human brain, moving sodium relaxometric mapping toward clinically relevant measurement times.


Assuntos
Imageamento por Ressonância Magnética , Sódio , Encéfalo/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador , Espectroscopia de Ressonância Magnética , Imagens de Fantasmas
5.
NMR Biomed ; 34(8): e4541, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33978270

RESUMO

The advancement of clinical applications of ultrahigh field (UHF) MRI depends heavily on advances in technology, including the development of new radiofrequency (RF) coil designs. Currently, the number of commercially available 7 T head RF coils is rather limited, implying a need to develop novel RF head coil designs that offer superior transmit and receive performance. RF coils to be used for clinical applications must be robust and reliable. In particular, for transmit arrays, if a transmit channel fails the local specific absorption rate may increase, significantly increasing local tissue heating. Recently, dipole antennas have been proposed and used to design UHF head transmit and receive arrays. The dipole provides a unique simplicity while offering comparable transmit efficiency and signal-to-noise ratio with the conventional loop design. Recently, we developed a novel array design in our laboratory using a folded-end dipole antenna. In this work, we developed, constructed and evaluated an eight-element transceiver bent folded-end dipole array for human head imaging at 7 T. Driven in the quadrature circularly polarized mode, the array demonstrated more than 20% higher transmit efficiency and significantly better whole-brain coverage than that provided by a widely used commercial array. In addition, we evaluated passive dipole antennas for decoupling the proposed array. We demonstrated that in contrast to the common unfolded dipole array, the passive dipoles moved away from the sample not only minimize coupling between the adjacent folded-end active dipoles but also produce practically no destructive interference with the quadrature mode of the array.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Encéfalo/diagnóstico por imagem , Mapeamento Encefálico , Simulação por Computador , Campos Eletromagnéticos , Humanos
6.
J Magn Reson ; 322: 106877, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33278812

RESUMO

In this work, we propose an application of a metamaterial inspired volumetric wireless coil (WLC) based on coupled split-loop resonators for targeted breast MRI at 1.5 T. Due to strong electromagnetic coupling with the body coil, the metamaterial inspired WLC locally focuses radiofrequency (RF) magnetic flux in the target region, thus improving both transmit and receive performance of the external body coil. This leads to substantial enhancement in local transmit efficiency and improvement of RF safety. Phantom images showed a tenfold increase of signal-to-noise ratio (SNR) in the region-of-interest (ROI) and, at the same time, an almost 50-fold reduction in transmit power relative to the same body coil used alone.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Aumento da Imagem/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Desenho de Equipamento , Feminino , Humanos , Imagens de Fantasmas
7.
Magn Reson Med ; 82(4): 1518-1526, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31095776

RESUMO

PURPOSE: To investigate the correlation between electrical conductivity and sodium concentration, both measured in vivo, in the human brain. METHODS: Conductivity measurements were performed on samples with different sodium (Na+ ) and agarose concentrations using a dielectric probe, and the correlation between conductivity and Na+ content was evaluated. Subsequently, brain conductivity and total Na+ content maps were measured in 8 healthy subjects using phase-based MREPT and sodium MRI, respectively. After co-registration and spatial normalization to the 1 mm 152 MNI brain atlas, the relationship between conductivity and tissue sodium concentration (TSC) was examined within different brain regions. RESULTS: The conductivities of agarose gels increased linearly with NaCl concentration, while remaining almost independent of agarose content. When measured in healthy subjects, conductivities showed positive correlation with total tissue sodium concentration (R = 0.39, P < 0.005). The same trend was found in gray matter (R = 0.36, P < 0.005) and in white matter (R = 0.28, P < 0.05). CONCLUSION: Tissue conductivity shows a positive correlation with total sodium concentration. Conductivity might serve as a novel technique to visualize the total tissue electrolyte concentration, although refinements in the consideration of e.g., tissue water content, would be necessary to improve the quantitative value.


Assuntos
Química Encefálica/fisiologia , Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Sódio/química , Adulto , Encéfalo/fisiologia , Condutividade Elétrica , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Rede Nervosa/diagnóstico por imagem , Imagens de Fantasmas , Processamento de Sinais Assistido por Computador
8.
IEEE Trans Med Imaging ; 37(12): 2613-2618, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-29994198

RESUMO

MRI using nuclei other than protons is of clinical interest due to the important role of these nuclei in cellular processes. Phosphorous-31 (31P), for example, plays an important role in energy metabolism. However, measurement of 31P can be challenging, as the receive signal is weak compared with that of proton (1H). Consequently, it is often necessary to integrate 1H elements for localizations and B0 shimming in RF coils intended for 31P measurements. Good decoupling between the 1H and the 31P elements is therefore essential. In this paper, bent dipole antennas tuned to 1H were integrated with a four channel 31P loop coil array, in a manner providing strong geometric decoupling between dipoles and loops. As the physical length of a resonant dipole antenna is too long at 3T, the dipole antennas were bent around the load. The loss of 31P elements due to the presence of the dipole antennas was evaluated by measuring scattering parameters and comparing the SNR of 31P spectra with and without the presence of the dipole antennas. The performance of the bent dipole antenna was evaluated by simulation and sensitivity measurement. The Q-factors and the SNR of the four-loop array were reduced by less than 5% when the bent dipole antennas were introduced. The measured sensitivity of the bent dipole was higher (15%) than that of dual-tuned birdcage. The combined bent dipole and loop array is therefore a promising design for 1H/31P applications at 3T.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Desenho de Equipamento , Cabeça/diagnóstico por imagem , Humanos , Modelos Biológicos , Imagens de Fantasmas
9.
Magn Reson Med ; 76(5): 1636-1641, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-26608834

RESUMO

PURPOSE: Modification of a clinical MRI scanner to enable simultaneous or rapid interleaved acquisition of signals from two different nuclei. METHODS: A device was developed to modify the local oscillator signal fed to the receive channel(s) of an MRI console. This enables external modification of the frequency at which the receiver is sensitive and rapid switching between different frequencies. Use of the device was demonstrated with interleaved and simultaneous 31 P and 1 H spectroscopic acquisitions, and with interleaved 31 P and 1 H imaging. RESULTS: Signal amplitudes and signal-to-noise ratios were found to be unchanged for the modified system, compared with data acquired with the MRI system in the standard configuration. CONCLUSION: Interleaved and simultaneous 1 H and 31 P signal acquisition was successfully demonstrated with a clinical MRI scanner, with only minor modification of the RF architecture. While demonstrated with 31 P, the modification is applicable to any detectable nucleus without further modification, enabling a wide range of simultaneous and interleaved experiments to be performed within a clinical setting. Magn Reson Med 76:1636-1641, 2016. © 2015 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.


Assuntos
Espectroscopia de Ressonância Magnética Nuclear de Carbono-13/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Imagem Molecular/instrumentação , Isótopos de Fósforo/farmacocinética , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Integração de Sistemas
10.
Magn Reson Med ; 73(2): 894-900, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24590906

RESUMO

PURPOSE: Carbon-13 magnetic resonance spectroscopy ((13) C-MRS) is challenging because of the inherent low sensitivity of (13) C detection and the need for radiofrequency transmission at the (1) H frequency while receiving the (13) C signal, the latter requiring electrical decoupling of the (13) C and (1) H radiofrequency channels. In this study, we added traps to the (13) C coil to construct a quadrature-(13) C/quadrature-(1) H surface coil, with sufficient isolation between channels to allow simultaneous operation at both frequencies without compromise in coil performance. METHODS: Isolation between channels was evaluated on the bench by measuring all coupling parameters. The quadrature mode of the quadrature-(13) C coil was assessed using in vitro (23) Na gradient echo images. The signal-to-noise ratio (SNR) was measured on the glycogen and glucose resonances by (13) C-MRS in vitro, compared with that obtained with a linear-(13) C/quadrature-(1) H coil, and validated by (13) C-MRS in vivo in the human calf at 7T. RESULTS: Isolation between channels was better than -30 dB. The (23) Na gradient echo images indicate a region where the field is strongly circularly polarized. The quadrature coil provided an SNR enhancement over a linear coil of 1.4, in vitro and in vivo. CONCLUSION: It is feasible to construct a double-quadrature (13) C-(1) H surface coil for proton decoupled sensitivity enhanced (13) C-NMR spectroscopy in humans at 7T.


Assuntos
Glicogênio/análise , Magnetismo/instrumentação , Músculo Esquelético/química , Espectroscopia de Prótons por Ressonância Magnética/instrumentação , Adulto , Isótopos de Carbono/análise , Isótopos de Carbono/química , Desenho de Equipamento , Análise de Falha de Equipamento , Estudos de Viabilidade , Humanos , Masculino , Prótons , Ondas de Rádio , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Distribuição Tecidual
11.
J Magn Reson ; 245: 125-32, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25036294

RESUMO

Parallel radiofrequency (RF) transmission, either in the form of RF shimming or pulse design, has been proposed as a solution to the B1(+) inhomogeneity problem in ultra high field magnetic resonance imaging. As a prerequisite, accurate B1(+) maps from each of the available transmit channels are required. In this work, four different encoding methods for B1(+) mapping, namely 1-channel-on, all-channels-on-except-1, all-channels-on-1-inverted and Fourier phase encoding, were evaluated using dual refocusing acquisition mode (DREAM) at 9.4 T. Fourier phase encoding was demonstrated in both phantom and in vivo to be the least susceptible to artefacts caused by destructive RF interference at 9.4 T. Unlike the other two interferometric encoding schemes, Fourier phase encoding showed negligible dependency on the initial RF phase setting and therefore no prior B1(+) knowledge is required. Fourier phase encoding also provides a flexible way to increase the number of measurements to increase SNR, and to allow further reduction of artefacts by weighted decoding. These advantages of Fourier phase encoding suggest that it is a good choice for B1(+) mapping in parallel transmit systems at ultra high field.

12.
Neuroimage ; 93 Pt 1: 138-45, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24555953

RESUMO

Recent studies at high field (7Tesla) have reported small metabolite changes, in particular lactate and glutamate (below 0.3µmol/g) during visual stimulation. These studies have been limited to the visual cortex because of its high energy metabolism and good magnetic resonance spectroscopy (MRS) sensitivity using surface coil. The aim of this study was to extend functional MRS (fMRS) to investigate for the first time the metabolite changes during motor activation at 7T. Small but sustained increases in lactate (0.17µmol/g±0.05µmol/g, p<0.001) and glutamate (0.17µmol/g±0.09µmol/g, p<0.005) were detected during motor activation followed by a return to the baseline after the end of activation. The present study demonstrates that increases in lactate and glutamate during motor stimulation are small, but similar to those observed during visual stimulation. From the observed glutamate and lactate increase, we inferred that these metabolite changes may be a general manifestation of the increased neuronal activity. In addition, we propose that the measured metabolite concentration increases imply an increase in ΔCMRO2 that is transiently below that of ΔCMRGlc during the first 1 to 2min of the stimulation.


Assuntos
Encéfalo/metabolismo , Ácido Glutâmico/metabolismo , Ácido Láctico/metabolismo , Atividade Motora/fisiologia , Adolescente , Adulto , Mapeamento Encefálico , Feminino , Humanos , Espectroscopia de Ressonância Magnética , Masculino , Adulto Jovem
13.
J Magn Reson Imaging ; 40(4): 804-12, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24446194

RESUMO

PURPOSE: To evaluate the combination of low-B1 (+) adiabatic pulses and high permittivity (εr ≈ 165) dielectric pads effectiveness to reproducibly improve the inversion efficiency for whole-brain MP2RAGE scans, at ultra-high field. MATERIALS AND METHODS: Two low-B1 (+) adiabatic pulses, HS8 and TR-FOCI, were compared with the conventional HS1 adiabatic pulse in MP2RAGE acquisitions of four subjects at 7 Tesla. The uniform MP2RAGE images were qualitatively assessed for poor inversion artifacts by trained observers. Each subject was rescanned using dielectric pads. Eight further subjects underwent two MP2RAGE scan sessions using dielectric pads and the TR-FOCI adiabatic pulse. RESULTS: The HS8 and TR-FOCI pulses improved inversion coverage in all subjects compared with the HS1 pulse. However, in subjects whose head lengths are large (≥136 mm) relative to the coil's z-coverage, the B1 (+) field over the cerebellum was insufficient to cause inversion. Dielectric pads increase the B1 (+) field, by ∼50%, over the cerebellum, which in conjunction with the TR-FOCI pulse, reproducibly improves the inversion efficiency over the whole brain for subjects with head lengths ≤155 mm. Minor residual inversion artifacts were present in three of eight subjects (head lengths ≥155 mm). CONCLUSION: The complementary techniques of low-B1 (+) adiabatic RF pulses and high permittivity dielectric pads allow whole-brain structural T1 w images to be reliably acquired at ultra-high field. J. Magn. Reson. Imaging 2014;40:804-812. © 2013 Wiley Periodicals, Inc.


Assuntos
Algoritmos , Encéfalo/anatomia & histologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Processamento de Sinais Assistido por Computador , Adulto , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
Magn Reson Med ; 72(2): 584-90, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24006123

RESUMO

PURPOSE: Multinuclear magnetic resonance spectroscopy and imaging require a radiofrequency probe capable of transmitting and receiving at the proton and non-proton frequencies. To minimize coupling between probe elements tuned to different frequencies, LC (inductor-capacitor) traps blocking current at the (1)H frequency can be inserted in non-proton elements. This work compares LC traps with LCC traps, a modified design incorporating an additional capacitor, enabling control of the trap reactance at the low frequency while maintaining (1)H blocking. METHODS: Losses introduced by both types of trap were analysed using circuit models. Radiofrequency coils incorporating a series of LC and LCC traps were then built and evaluated at the bench. LCC trap performance was then confirmed using (1)H and (13)C measurements in a 7T human scanner. RESULTS: LC and LCC traps both effectively block interaction between non-proton and proton coils at the proton frequency. LCC traps were found to introduce a sensitivity reduction of 5±2%, which was less than half of that caused by LC traps. CONCLUSION: Sensitivity of non-proton coils is critical. The improved trap design, incorporating one extra capacitor, significantly reduces losses introduced by the trap in the non-proton coil.


Assuntos
Aumento da Imagem/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Magnetismo/instrumentação , Transdutores , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Magnetismo/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
15.
Artigo em Inglês | MEDLINE | ID: mdl-25570463

RESUMO

An essential feature of magnetic resonance (MR) probes for magnetic resonance imaging and spectroscopy is the ability to generate uniform B(1)(+) excitation in a volume of interest. When the magnetic field strength is increased, leading to an increase in resonance frequency, the constraints on the MR probes size, the sample size and the associated radiation losses caused by conductor elements are higher. In this study we simulate, test and construct two birdcage coils for imaging rodents operated at 14.1 T. Bench experiments and imaging tests show that at 14.1 T dielectric resonance effect is the dominant factor accounting for B(1)(+) field inhomogeneity but remained achievable for imaging rodent brains.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Animais , Calibragem , Simulação por Computador , Imagens de Fantasmas , Ondas de Rádio , Roedores
16.
J Neurosci Res ; 91(8): 1050-8, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23239399

RESUMO

Glucose metabolism is difficult to image with cellular resolution in mammalian brain tissue, particularly with (18) fluorodeoxy-D-glucose (FDG) positron emission tomography (PET). To this end, we explored the potential of synchrotron-based low-energy X-ray fluorescence (LEXRF) to image the stable isotope of fluorine (F) in phosphorylated FDG (DG-6P) at 1 µm(2) spatial resolution in 3-µm-thick brain slices. The excitation-dependent fluorescence F signal at 676 eV varied linearly with FDG concentration between 0.5 and 10 mM, whereas the endogenous background F signal was undetectable in brain. To validate LEXRF mapping of fluorine, FDG was administered in vitro and in vivo, and the fluorine LEXRF signal from intracellular trapped FDG-6P over selected brain areas rich in radial glia was spectrally quantitated at 1 µm(2) resolution. The subsequent generation of spatial LEXRF maps of F reproduced the expected localization and gradients of glucose metabolism in retinal Müller glia. In addition, FDG uptake was localized to periventricular hypothalamic tanycytes, whose morphological features were imaged simultaneously by X-ray absorption. We conclude that the high specificity of photon emission from F and its spatial mapping at ≤1 µm resolution demonstrates the ability to identify glucose uptake at subcellular resolution and holds remarkable potential for imaging glucose metabolism in biological tissue.


Assuntos
Mapeamento Encefálico/métodos , Córtex Cerebral/diagnóstico por imagem , Fluordesoxiglucose F18 , Glucose/metabolismo , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos , Animais , Córtex Cerebral/metabolismo , Metabolismo Energético/fisiologia , Estudos de Viabilidade , Fluorescência , Ratos , Ratos Sprague-Dawley , Raios X
17.
Magn Reson Med ; 67(6): 1609-19, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22135168

RESUMO

At high magnetic field strengths (≥ 3T), the radiofrequency wavelength used in MRI is of the same order of magnitude of (or smaller than) the typical sample size, making transmit magnetic field (B1+) inhomogeneities more prominent. Methods such as radiofrequency-shimming and transmit SENSE have been proposed to mitigate these undesirable effects. A prerequisite for such approaches is an accurate and rapid characterization of the B1+ field in the organ of interest. In this work, a new phase-sensitive three-dimensional B1+-mapping technique is introduced that allows the acquisition of a 64 × 64 × 8 B1+-map in ≈ 20 s, yielding an accurate mapping of the relative B1+ with a 10-fold dynamic range (0.2-2 times the nominal B1+). Moreover, the predominant use of low flip angle excitations in the presented sequence minimizes specific absorption rate, which is an important asset for in vivo B1+-shimming procedures at high magnetic fields. The proposed methodology was validated in phantom experiments and demonstrated good results in phantom and human B1+-shimming using an 8-channel transmit-receive array.


Assuntos
Algoritmos , Encéfalo/anatomia & histologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Processamento de Sinais Assistido por Computador , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
18.
Artigo em Inglês | MEDLINE | ID: mdl-22255948

RESUMO

Among numerous magnetic resonance imaging (MRI) techniques, perfusion MRI provides insight into the passage of blood through the brain's vascular network non-invasively. Studying disease models and transgenic mice would intrinsically help understanding the underlying brain functions, cerebrovascular disease and brain disorders. This study evaluates the feasibility of performing continuous arterial spin labeling (CASL) on all cranial arteries for mapping murine cerebral blood flow at 9.4 T. We showed that with an active-detuned two-coil system, a labeling efficiency of 0.82 ± 0.03 was achieved with minimal magnetization transfer residuals in brain. The resulting cerebral blood flow of healthy mouse was 99 ± 26 mL/100g/min, in excellent agreement with other techniques. In conclusion, high magnetic fields deliver high sensitivity and allowing not only CASL but also other MR techniques, i.e. (1)H MRS and diffusion MRI etc, in studying murine brains.


Assuntos
Encéfalo/irrigação sanguínea , Circulação Cerebrovascular , Imageamento por Ressonância Magnética/métodos , Animais , Artefatos , Barreira Hematoencefálica , Encéfalo/patologia , Mapeamento Encefálico/métodos , Processamento de Imagem Assistida por Computador , Campos Magnéticos , Espectroscopia de Ressonância Magnética/métodos , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Modelos Anatômicos , Modelos Estatísticos , Reprodutibilidade dos Testes , Marcadores de Spin
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA