Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
1.
Eur Heart J Cardiovasc Imaging ; 24(12): 1690-1699, 2023 11 23.
Artigo em Inglês | MEDLINE | ID: mdl-37409985

RESUMO

AIMS: Remnant cholesterol (RC) seems associated with native aortic stenosis. Bioprosthetic valve degeneration may share similar lipid-mediated pathways with aortic stenosis. We aimed to investigate the association of RC with the progression of bioprosthetic aortic valve degeneration and ensuing clinical outcomes. METHODS AND RESULTS: We enrolled 203 patients with a median of 7.0 years (interquartile range: 5.1-9.2) after surgical aortic valve replacement. RC concentration was dichotomized by the top RC tertile (23.7 mg/dL). At 3-year follow-up, 121 patients underwent follow-up visit for the assessment of annualized change in aortic valve calcium density (AVCd). RC levels showed a curvilinear relationship with an annualized progression rate of AVCd, with increased progression rates when RC >23.7 mg/dL (P = 0.008). There were 99 deaths and 46 aortic valve re-interventions in 133 patients during a median clinical follow-up of 8.8 (8.7-9.6) years. RC >23.7 mg/dL was independently associated with mortality or re-intervention (hazard ratio: 1.98; 95% confidence interval: 1.31-2.99; P = 0.001). CONCLUSION: Elevated RC is independently associated with faster progression of bioprosthetic valve degeneration and increased risk of all-cause mortality or aortic valve re-intervention.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Falha de Prótese , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Colesterol , Bioprótese/efeitos adversos , Resultado do Tratamento
2.
JACC Cardiovasc Imaging ; 16(10): 1253-1267, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37178071

RESUMO

BACKGROUND: Primary mitral regurgitation (MR) is a heterogeneous clinical disease requiring integration of echocardiographic parameters using guideline-driven recommendations to identify severe disease. OBJECTIVES: The purpose of this preliminary study was to explore novel data-driven approaches to delineate phenotypes of MR severity that benefit from surgery. METHODS: The authors used unsupervised and supervised machine learning and explainable artificial intelligence (AI) to integrate 24 echocardiographic parameters in 400 primary MR subjects from France (n = 243; development cohort) and Canada (n = 157; validation cohort) followed up during a median time of 3.2 years (IQR: 1.3-5.3 years) and 6.8 (IQR: 4.0-8.5 years), respectively. The authors compared the phenogroups' incremental prognostic value over conventional MR profiles and for the primary endpoint of all-cause mortality incorporating time-to-mitral valve repair/replacement surgery as a covariate for survival analysis (time-dependent exposure). RESULTS: High-severity (HS) phenogroups from the French cohort (HS: n = 117; low-severity [LS]: n = 126) and the Canadian cohort (HS: n = 87; LS: n = 70) showed improved event-free survival in surgical HS subjects over nonsurgical subjects (P = 0.047 and P = 0.020, respectively). A similar benefit of surgery was not seen in the LS phenogroup in both cohorts (P = 0.70 and P = 0.50, respectively). Phenogrouping showed incremental prognostic value in conventionally severe or moderate-severe MR subjects (Harrell C statistic improvement; P = 0.480; and categorical net reclassification improvement; P = 0.002). Explainable AI specified how each echocardiographic parameter contributed to phenogroup distribution. CONCLUSIONS: Novel data-driven phenogrouping and explainable AI aided in improved integration of echocardiographic data to identify patients with primary MR and improved event-free survival after mitral valve repair/replacement surgery.

3.
Arch Cardiovasc Dis ; 116(3): 151-158, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36805238

RESUMO

BACKGROUND: The optimal timing for mitral valve (MV) surgery in asymptomatic patients with primary mitral regurgitation (MR) remains a matter of debate. Myocardial contraction fraction (MCF) - the ratio of the left ventricular (LV) stroke volume to that of the myocardial volume - is a volumetric measure of LV myocardial shortening independent of size or geometry. AIM: To assess the relationship between MCF and outcome in patients with significant chronic primary MR due to prolapse managed in contemporary practice. METHODS: Clinical, Doppler-echocardiographic and outcome data prospectively collected in 174 patients (mean age 62 years, 27% women) with significant primary MR and no or mild symptoms were analysed. The impact of MCF< or ≥30% on cardiac events (cardiovascular death, acute heart failure or MV surgery) was studied. RESULTS: During an estimated median follow-up of 49 (22-77) months, cardiac events occurred in 115 (66%) patients. The 4-year estimates of survival free from cardiac events were 21±5% for patients with MCF <30% and 40±6% for those with ≥30% (P<0.001). MCF <30% was associated with a considerable increased risk of cardiac events after adjustment for established clinical risk factors, MR severity and current recommended class I triggers for MV surgery (adjusted hazard ratio: 2.33, 95% confidence interval: 1.51-3.58; P<0.001). Moreover, MCF<30% improved the predictive performance of models, with better global fit, reclassification and discrimination. CONCLUSIONS: MCF<30% is strongly associated with occurrence of cardiac events in patients with significant primary MR due to prolapse. Further studies are needed to assess the direct impact of MCF on patient management and outcomes.


Assuntos
Insuficiência da Valva Mitral , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Relevância Clínica , Resultado do Tratamento , Estudos Retrospectivos , Volume Sistólico , Contração Miocárdica , Prolapso
4.
Am J Cardiol ; 178: 97-105, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-35778308

RESUMO

The optimal timing for mitral valve (MV) surgery in asymptomatic patients with primary mitral regurgitation (MR) remains controversial. We aimed at evaluating the relation between left ventricular ejection time (LVET) and outcome in patients with moderate or severe chronic primary MR because of prolapse. Clinical, Doppler echocardiographic, and outcome data prospectively collected from 302 patients (median age 61 [54 to 74] years, 34% women) with moderate or severe primary MR were analyzed. Patients were retrospectively stratified by quartiles of LVET. The primary end point of the study was the composite of need for MV surgery or all-cause mortality. During a median follow-up time of 66 (25th to 75th percentile, 33 to 95) months, 178 patients reached the primary end point. Patients in the lowest quartile of LVET (<260 ms) were at high risk for adverse events compared with those in the other quartiles of LVET (global p = 0.005), whereas the rate of events was similar for the other quartiles (p = NS for all). After adjustment for clinical predictors of outcome, including age, gender, history of atrial fibrillation, MR severity, and current recommended triggers for MV surgery in asymptomatic primary MR, LVET <260 ms was associated with an increased risk of events (adjusted hazard ratio 1.49, 95% confidence interval 1.03 to 2.16, p = 0.033). In conclusion, we observed that shorter LVET is associated with increased risk of adverse events in patients with moderate or severe primary MR because of prolapse. Further studies are required to investigate whether shorter LVET has a direct effect on outcomes or is solely a risk marker in primary MR.


Assuntos
Insuficiência da Valva Mitral , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/cirurgia , Prolapso , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Resultado do Tratamento
5.
Struct Heart ; 6(1): 100004, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37273475

RESUMO

Background: Optimal timing for intervention remains uncertain in asymptomatic patients with primary mitral regurgitation (MR). We aimed to assess the prognostic value of a new cardiac damage staging classification in patients with asymptomatic moderate or severe primary MR. Methods: Clinical, Doppler-echocardiographic, and outcome data prospectively collected in 338 asymptomatic patients (64 ± 15 years, 68% men) with at least moderate primary MR were retrospectively analyzed. Patients were hierarchically classified as per the following staging classification: no cardiac damage (stage 0), mild left ventricular or left atrial damage (stage 1), moderate or severe left ventricular or left atrial damage (stage 2), pulmonary vasculature or tricuspid valve damage (stage 3), or right ventricular damage (stage 4). Results: There was a stepwise increase in 10-year mortality rates as per cardiac damage stage: 20.0% in stage 0, 25.6% in stage 1, 31.5% in stage 2, and 61.3% in stage 3-4 (p < 0.001). The staging classification was significantly associated with increased risk of mortality (hazard ratio = 1.41 per one-stage increase, 95% confidence interval: 1.07-1.85, p = 0.015) and the composite of cardiovascular mortality or hospitalization (hazard ratio = 1.51 per one-stage increase, 95% confidence interval: 1.07-2.15, p = 0.020) in multivariable analysis adjusted for EuroSCORE II, mitral valve intervention as a time-dependent variable, and other risk factors. The proposed scheme showed incremental value over several clinical variables (net reclassification index = 0.40, p = 0.03). Conclusions: The new staging classification provides independent and incremental prognostic value in patients with asymptomatic moderate or severe MR.

6.
Echocardiography ; 38(11): 1973-1977, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34755387

RESUMO

Constrictive pericarditis (CP) is a curable cause of diastolic heart failure with prior cardiac surgery being a recognizable etiology. We report a patient who developed CP one year following heart transplantation. Several clinical and imaging related factors may lead to diagnostic delays in similar patients, including the mistaken belief that transplanted hearts are devoid of pericardium and thus do not develop constriction. Post-transplantation pericardial effusion, mediastinitis, and cardiac rejection predispose to future CP. Caretakers should consider this entity in allograft recipients who develop heart failure symptoms of unclear etiology.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Derrame Pericárdico , Pericardite Constritiva , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/etiologia , Transplante de Coração/efeitos adversos , Humanos , Pericardite Constritiva/diagnóstico por imagem , Pericardite Constritiva/etiologia , Pericárdio
7.
J Am Soc Echocardiogr ; 34(3): 223-236, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33678222

RESUMO

Data obtained from echocardiographic studies are used on a daily basis to guide clinical decision-making regarding patient management and the need for additional diagnostic investigations. Interrogation of blood flow in the pulmonary veins by spectral, most often pulsed-wave, Doppler is an important component of any comprehensive echocardiographic study. Whereas it is most often used to help assess left-sided filling pressure and quantify the severity of mitral regurgitation, the pulmonary vein Doppler profile provides added diagnostic insights into several disorders that affect heart function and allows assessment of their hemodynamic consequences on the heart. The aim of this review is to summarize current knowledge in the field of PV Doppler interrogation, highlight the physiological and pathological parameters that influence it, and delineate the manifestations of various cardiovascular disorders on the flow profile.


Assuntos
Insuficiência da Valva Mitral , Veias Pulmonares , Velocidade do Fluxo Sanguíneo , Ecocardiografia Doppler , Hemodinâmica , Humanos , Veias Pulmonares/diagnóstico por imagem , Ultrassonografia Doppler
8.
J Am Coll Cardiol ; 76(15): 1737-1748, 2020 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-33032735

RESUMO

BACKGROUND: The prognostic value of aortic valve calcification (AVC) measured by using multidetector computed tomography imaging has been well validated in native aortic stenosis, and sex-specific thresholds have been proposed. However, few data are available regarding the impact of leaflet calcification on outcomes after biological aortic valve replacement (AVR). OBJECTIVES: The goal of this study was to analyze the association of quantitative bioprosthetic leaflet AVC with hemodynamic and clinical outcomes, as well as its possible interaction with sex. METHODS: From 2008 to 2010, a total of 204 patients were prospectively enrolled with a median of 7.0 years (interquartile range: 5.1 to 9.2 years) after biological surgical AVR. AVC measured by using the Agatston method was indexed to the cross-sectional area of aortic annulus measured by echocardiography to calculate the AVC density (AVCd). Presence of hemodynamic valve deterioration (HVD; increase in mean gradient [MG] ≥10 mm Hg and/or increase in transprosthetic regurgitation ≥1) was assessed by echocardiography in 137 patients at the 3-year follow-up. The primary clinical endpoint was mortality or aortic valve re-intervention. RESULTS: There was no significant sex-related difference in the relationship between bioprosthetic AVCd and the progression of MG. Baseline AVCd showed an independent association with HVD at 3 years. During follow-up, there were 134 (65.7%) deaths (n = 100) or valve re-interventions (n = 47). AVCd ≥58 AU/cm2 was independently associated with an increased risk of mortality or aortic valve re-intervention (adjusted hazard ratio: 2.23; 95% confidence interval: 1.44 to 3.35; p < 0.001). The AVCd threshold combined with an MG progression threshold of 10 mm Hg amplified the stratification of patients at risk (log-rank, p < 0.001). The addition of AVCd threshold into the prediction model including traditional risk factors improved outcome prediction (net classification improvement: 0.25, p = 0.04; likelihood ratio test, p < 0.001). CONCLUSIONS: Aortic bioprosthetic leaflet calcification is strongly and independently associated with HVD and the risk of death or aortic valve re-intervention. As opposed to native aortic stenosis, there is no sex-related differences in the relationship between AVCd and hemodynamic or clinical outcomes.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/patologia , Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Calcinose/fisiopatologia , Próteses Valvulares Cardíacas/efeitos adversos , Hemodinâmica/fisiologia , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/fisiopatologia , Calcinose/diagnóstico , Ecocardiografia Doppler , Feminino , Seguimentos , Humanos , Masculino , Tomografia Computadorizada Multidetectores/métodos , Desenho de Prótese , Falha de Prótese , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo
9.
Am J Physiol Heart Circ Physiol ; 317(4): H685-H694, 2019 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-31347913

RESUMO

High-intensity interval training (HIIT) improves physical performance of endurance athletes, although studies examining its cardiovascular effects are sparse. We evaluated the impact of HIIT on blood pressure, heart rate, and cardiac cavities' size and function in endurance-trained adults. Seventeen endurance-trained men underwent 24-h ambulatory blood pressure monitoring and Doppler echocardiography at baseline and after 6 wk of HIIT. Participants were divided into 2 groups [85% maximal aerobic power (HIIT85), n = 8 and 115% maximal aerobic power (HIIT115), n = 9] to compare the impact of different HIIT intensities. Ambulatory blood pressure monitoring and cardiac chambers' size and function were similar between groups at baseline. HIIT reduced heart rate (55 ± 8 vs. 51 ± 7 beats/min; P = 0.003), systolic blood pressure (121 ± 11 vs. 118 ± 9 mmHg; P = 0.01), mean arterial pressure (90 ± 8 vs. 89 ± 6 mmHg; P = 0.03), and pulse pressure (52 ± 6 vs. 49 ± 5 mmHg; P = 0.01) irrespective of training intensity. Left atrium volumes increased after HIIT (maximal: 50 ± 14 vs. 54 ± 14 mL; P = 0.02; minimal: 15 ± 5 vs. 20 ± 8 mL; P = 0.01) in both groups. Right ventricle global longitudinal strain lowered after training in the HIIT85 group only (20 ± 4 vs. 17 ± 3%, P = 0.04). In endurance-trained men, 6 wk of HIIT reduced systolic blood pressure and mean arterial pressure and increased left atrium volumes irrespective of training intensity, whereas submaximal HIIT deteriorated right ventricle systolic function.NEW & NOTEWORTHY The novel findings of this study are that 6 wk of high-intensity interval training increases left atrial volumes irrespective of training intensity (85 or 115% maximal aerobic power), whereas the submaximal training decreases right ventricular systolic function in endurance-trained men. These results may help identify the exercise threshold for potential toxicity of intense exercise training for at-risk individuals and ideal exercise training regimens conferring optimal cardiovascular protection and adapted endurance training for athletes.


Assuntos
Cardiomegalia Induzida por Exercícios , Treinamento Intervalado de Alta Intensidade , Hipertrofia Ventricular Direita/fisiopatologia , Resistência Física , Disfunção Ventricular Direita/fisiopatologia , Função Ventricular Direita , Remodelação Ventricular , Adulto , Pressão Arterial , Função do Átrio Esquerdo , Remodelamento Atrial , Ecocardiografia Doppler , Frequência Cardíaca , Humanos , Hipertrofia Ventricular Direita/diagnóstico por imagem , Hipertrofia Ventricular Direita/etiologia , Masculino , Fadiga Muscular , Fatores de Tempo , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/etiologia , Função Ventricular Esquerda , Adulto Jovem
10.
Circulation ; 138(10): 971-985, 2018 09 04.
Artigo em Inglês | MEDLINE | ID: mdl-30354532

RESUMO

BACKGROUND: The incidence of structural valve deterioration after bioprosthesis (BP) aortic valve replacement (AVR) established on the basis of reoperation may substantially underestimate the true incidence. The objective is to determine the rate, timing, correlates, and association between hemodynamic valve deterioration (HVD) and outcomes assessed by Doppler echocardiography after surgical BP AVR. METHODS: A total of 1387 patients (62.2% male, 70.5±7.8 years of age) who underwent BP AVR were included in this retrospective study. Baseline echocardiography was performed at a median time of 4.1 (1.3-6.5) months after AVR. All patients had an echocardiographic follow-up ≥2 years after AVR (926 at least 5 years and 385 at least 10 years). HVD was defined by Doppler assessment as a ≥10 mm Hg increase in mean gradient or worsening of transprosthetic regurgitation ≥1/3 class. HVD was classified according to the timing after AVR: "very early," during the first 2-years; "early," between 2 and 5 years; "midterm," between 5 and 10 years; and "long-term," >10 years. RESULTS: A total of 428 patients (30.9%) developed HVD. Among these patients, 52 (12.0%) were classified as "very early," 129 (30.1%) as "early," 158 (36.9%) as "midterm," and 89 (20.8%) as "long-term" HVD. Factors independently associated with HVD occurring within the first 5 years after AVR were diabetes mellitus ( P=0.01), active smoking ( P=0.01), renal insufficiency ( P=0.01), baseline postoperative mean gradient ≥15 mm Hg ( P=0.04) or transprosthetic regurgitation ≥mild ( P=0.04), and type of BP (stented versus stentless, P=0.003). Factors associated with HVD occurring after the fifth year after AVR were female sex ( P=0.03), warfarin use ( P=0.007), and BP type ( P<0.001). HVD was independently associated with mortality (hazard ratio, 2.18; 95% CI, 1.86-2.57; P<0.001). CONCLUSIONS: HVD as identified by Doppler echocardiography occurred in one third of patients and was associated with a 2.2-fold higher adjusted mortality. Diabetes mellitus and renal insufficiency were associated with early HVD, whereas female sex, warfarin use, and stented BPs (versus stentless) were associated with late HVD.


Assuntos
Valva Aórtica/cirurgia , Bioprótese , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Hemodinâmica , Falha de Prótese , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Ecocardiografia Doppler , Feminino , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/mortalidade , Doenças das Valvas Cardíacas/fisiopatologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
11.
J Am Coll Cardiol ; 72(3): 241-251, 2018 07 17.
Artigo em Inglês | MEDLINE | ID: mdl-30012316

RESUMO

BACKGROUND: Dysmetabolic profile has been associated with native aortic valve stenosis. However, there are limited data on the effects of an atherogenic milieu and its potential implications on the structural and hemodynamic deterioration of aortic bioprosthetic valves. OBJECTIVES: This prospective longitudinal study sought to determine the predictors and impact on outcomes of hemodynamic valve deterioration (HVD) of surgically implanted aortic bioprostheses. METHODS: A total of 137 patients with an aortic bioprosthesis implanted for a median time of 6.7 (interquartile range: 5.1 to 9.1) years prospectively underwent a first (baseline) assessment with complete Doppler echocardiography, quantitation of bioprosthesis leaflet calcification by multidetector computed tomography (CT), and a fasting blood sample to assess cardiometabolic risk profile. All patients underwent a second (follow-up) Doppler echocardiography examination at 3 (interquartile range: 2.9 to 3.3) years post-baseline visit. HVD was defined by an annualized change in mean transprosthetic gradient ≥3 mm Hg/year and/or worsening or transprosthetic regurgitation by ≥1/3 class. The primary endpoint was a nonhierarchical composite of death from any cause or aortic reintervention procedure (redo surgical valve replacement or transcatheter valve-in-valve implantation) for bioprosthesis failure. RESULTS: Thirty-four patients (25.6%) had leaflet calcification on baseline CT, and 18 patients (13.1%) developed an HVD between baseline and follow-up echocardiography. Fifty-two patients (38.0%) met the primary endpoint during subsequent follow-up after the second echocardiographic examination. Leaflet calcification (hazard ratio [HR]: 2.58; 95% confidence interval [CI]: 1.35 to 4.82; p = 0.005) and HVD (HR: 5.12; 95% CI: 2.57 to 9.71; p < 0.001) were independent predictors of the primary endpoint. Leaflet calcification, insulin resistance (homeostatic model assessment index ≥2.7), lipoprotein-associated phospholipase A2 activity (Lp-PLA2 per 0.1 nmol/min/ml increase), and high level of proprotein convertase subtilisin/kexin 9 (PCSK9) (≥305 ng/ml) were associated with the development of HVD after adjusting for age, sex, and time interval since aortic valve replacement. CONCLUSIONS: HVD identified by Doppler echocardiography is independently associated with a marked increase in the risk of valve reintervention or mortality in patients with a surgical aortic bioprosthesis. A dysmetabolic profile characterized by elevated plasma Lp-PLA2, PCSK9, and homeostatic model assessment index was associated with increased risk of HVD. The presence of leaflet calcification as detected by CT was a strong predictor of HVD, providing incremental risk-predictive capacity.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica , Calcinose , Implante de Prótese de Valva Cardíaca , Complicações Pós-Operatórias , 1-Alquil-2-acetilglicerofosfocolina Esterase/sangue , Idoso , Valva Aórtica/patologia , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Bioprótese , Calcinose/sangue , Calcinose/etiologia , Calcinose/fisiopatologia , Calcinose/cirurgia , Canadá , Ecocardiografia Doppler/métodos , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Hemodinâmica , Humanos , Estudos Longitudinais , Masculino , Avaliação de Processos e Resultados em Cuidados de Saúde , Complicações Pós-Operatórias/sangue , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/fisiopatologia , Complicações Pós-Operatórias/cirurgia , Pró-Proteína Convertase 9/sangue , Estudos Prospectivos , Desenho de Prótese , Falha de Prótese , Reoperação/métodos , Reoperação/mortalidade , Tomografia Computadorizada por Raios X/métodos
13.
J Am Heart Assoc ; 6(11)2017 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-29079561

RESUMO

BACKGROUND: The timing of mitral valve surgery in asymptomatic patients with primary mitral regurgitation (MR) is controversial. We hypothesized that the forward left ventricular (LV) ejection fraction (LVEF; ie, LV outflow tract stroke volume divided by LV end-diastolic volume) is superior to the total LVEF to predict outcomes in MR. The objective of this study was to examine the association between echocardiographic parameters of MR severity and LV function and outcomes in patients with MR. METHODS AND RESULTS: The clinical and Doppler-echocardiographic data of 278 patients with ≥mild MR and no class I indication of mitral valve surgery at baseline were retrospectively analyzed. The primary study end point was the composite of mitral valve surgery or death. During a mean follow-up of 5.4±3.2 years, there were 147 (53%) events: 96 (35%) MV surgeries and 66 (24%) deaths. Total LVEF and global longitudinal strain were not associated with the occurrence of events, whereas forward LVEF (P<0.0001) and LV end-systolic diameter (P=0.0003) were. After adjustment for age, sex, MR severity, Charlson probability, coronary artery disease, and atrial fibrillation, forward LVEF remained independently associated with the occurrence of events (adjusted hazard ratio: 1.09, [95% confidence interval]: 1.02-1.17 per 5% decrease; P=0.01), whereas LV end-systolic diameter was not (P=0.48). CONCLUSIONS: The results of this study suggest that the forward LVEF may be superior to the total LVEF and LV end-systolic diameter to predict outcomes in patients with primary MR. This simple and easily measurable parameter may be useful to improve risk stratification and select the best timing for intervention in patients with primary MR.


Assuntos
Insuficiência da Valva Mitral/fisiopatologia , Valva Mitral/fisiopatologia , Volume Sistólico , Função Ventricular Esquerda , Idoso , Idoso de 80 Anos ou mais , Doenças Assintomáticas , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Intervalo Livre de Doença , Ecocardiografia Doppler , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/cirurgia , Valor Preditivo dos Testes , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento , Disfunção Ventricular Esquerda/mortalidade , Disfunção Ventricular Esquerda/fisiopatologia
14.
Curr Treat Options Cardiovasc Med ; 18(11): 67, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27687067

RESUMO

OPINION STATEMENT: Prosthesis-patient mismatch (PPM) occurs when the effective orifice area (EOA) of a normally functioning prosthesis is too small in relation to the patient's body size, resulting in abnormally high postoperative gradients. PPM is frequent following aortic valve replacement (AVR), and it is associated with increased risk of morbidity and mortality proportionally to its severity. Differential diagnosis between PPM and prosthetic valve stenosis is made by comparing the measured valve effective orifice area, by assessing the changes in valve area and gradient during follow-up and by evaluating leaflet morphology and mobility. Preventive strategies to avoid or minimize PPM should be implemented especially in the patients who are at high risk for severe PPM and in those who have vulnerability factors to PPM. Transcatheter AVR may be superior to surgical AVR for the prevention of PPM and associated adverse cardiac events, particularly in the subset of patients with a small (<21 mm) aortic annulus. In this article, we discuss the most updated data regarding the diagnosis, clinical impact, and prevention of PPM after AVR.

15.
Heart ; 102(23): 1915-1921, 2016 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-27378363

RESUMO

INTRODUCTION: Structural valve degeneration (SVD) leads to the failure of aortic valve bioprostheses. It is suspected that lipid-derived factors could play a role in SVD. We hypothesised that oxidised low-density lipoprotein (OxLDL), OxLDL/LDL, OxLDL/high-density lipoprotein (OxLDL/HDL) and proprotein convertase subtilisin/kexin 9 (PCSK9) may be associated with SVD. METHODS: We included 199 patients who underwent an aortic valve replacement with a bioprosthesis and had an echocardiography follow-up to evaluate the function of the prosthesis. SVD was defined as an increase in mean transprosthetic gradient (≥10 mm Hg) or a worsening of transprosthetic regurgitation (≥1/3) during the follow-up. RESULTS: After a mean follow-up of 8±3.5 years, 41(21%) patients developed SVD. The univariate predictors of SVD were LDL (p=0.03), apolipoprotein B (p=0.01), OxLDL (p=0.02), OxLDL/HDL (p=0.009) and LDL associated with small, dense particles (LDL-C<255Å) (p=0.02). In a model adjusted for covariates, only OxLDL/HDL (OR 1.49, 95%CI 1.08 to 2.07 per 10 units, p=0.01) remained associated with SVD. There was a significant interaction between OxLDL/HDL and PCSK9 on SVD (p=0.05). After adjustment, compared with patients with low OxLDL/HDL (median, <25.4) and low PCSK9 (median, <298 ng/mL) (referent), patients with both an elevated OxLDL/HDL ratio and PCSK9 had a higher risk of SVD (OR 2.93, 95% CI 1.02 to 9.29, p=0.04). CONCLUSIONS: OxLDL/HDL ratio is independently associated with SVD.


Assuntos
Insuficiência da Valva Aórtica/etiologia , Valva Aórtica/cirurgia , Bioprótese , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Lipoproteínas HDL/sangue , Lipoproteínas LDL/sangue , Falha de Prótese , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/sangue , Insuficiência da Valva Aórtica/diagnóstico por imagem , Biomarcadores/sangue , Distribuição de Qui-Quadrado , Estudos Transversais , Ecocardiografia Doppler , Feminino , Humanos , Modelos Lineares , Modelos Logísticos , Masculino , Análise Multivariada , Razão de Chances , Pró-Proteína Convertase 9/sangue , Estudos Prospectivos , Desenho de Prótese , Medição de Risco , Fatores de Risco , Fatores de Tempo
16.
Clin Chim Acta ; 455: 20-5, 2016 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-26797670

RESUMO

BACKGROUND: We previously reported that plasma Lp-PLA2 was associated with aortic valve disease progression and degeneration of bioprostheses. Low systemic arterial compliance and high valvuloarterial impedance (Z(va)) are predictors of poor survival in patients with aortic valve disease. However, the prevalence of high Z(va) after AVR is largely unknown and whether Lp-PLA2 could predict Z(va) has not been documented. We investigated the relationships between plasma lipoprotein-associated phospholipase A2 (Lp-PLA2) mass and activity and valvuloarterial impedance (Z(va)), an index of global LV hemodynamic load, in patients that underwent aortic valve replacement (AVR). METHODS: A total of 195 patients with aortic bioprostheses underwent echocardiographic assessment of the prosthetic aortic valve function 8±3.4 years after AVR. Lp-PLA2 mass and activity were measured. RESULTS: In this group of patients, the mean Z(va) was elevated (5.73±1.21 mm Hg·ml(-1)·m(2)). In univariate analyses, Lp-PLA2 mass (p=0.003) and Lp-PLA2 activity (p=0.046) were associated with Z(va). After adjustment for covariates including age, gender, clinical risk factors, anti-hypertensive medications, body mass index and prosthesis size, Lp-PLA2 mass was associated with high Z(va) (≥4.5 mm Hg·ml(-1)·m(2)) (OR: 1.29, 95%CI: 1.10-1.53; p=0.005) and was inversely related with the systemic arterial compliance (ß=-0.01, SEM=0.003; p=0.003). CONCLUSIONS: An increased Z(va), an index of excessive hemodynamic load, was highly prevalent 8-year post-AVR and was independently related to circulating Lp-PLA2.


Assuntos
1-Alquil-2-acetilglicerofosfocolina Esterase/sangue , Valva Aórtica/cirurgia , Artérias/fisiopatologia , Complacência (Medida de Distensibilidade) , Próteses Valvulares Cardíacas , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino
17.
Heart ; 101(15): 1196-203, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25999587

RESUMO

OBJECTIVE: Low flow (LF), defined as stroke volume index (SVi) <35 mL/m(2), prior to the procedure has been recently identified as a powerful independent predictor of early and late mortality in patients undergoing transcatheter aortic valve replacement (TAVR). The objectives of this study were to determine the evolution of SVi following TAVR and to assess the determinants and impact on mortality of early postprocedural SVi (EP-SVi). METHODS: We retrospectively analysed the clinical, Doppler echocardiographic and outcome data prospectively collected in 255 patients who underwent TAVR. Echocardiograms were performed before (baseline), within 5 days after procedure (early post procedure) and 6 months to 1 year following TAVR (late post procedure). RESULTS: Patients with EP-SVi <35 mL/m(2) (n=138; 54%) had increased mortality (HR 1.97, p=0.003) compared with those with EP-SVi ≥35 mL/m(2) (n=117; 46%). Furthermore, patients with baseline SVi (B-SVi) <35 mL/m(2) and EP-SVI ≥35 mL/m(2), that is, normalised flow, had better survival (HR 0.46, p=0.03) than those with both B-SVi and EP-SVi <35 mL/m(2), that is, persistent LF, and similar survival compared with those with both B-SVi and EP-SVi ≥35 mL/m(2), that is, maintained normal flow. In a multivariable model analysis, EP-SVi was independently associated with increased risk of mortality (HR 1.41 per 10 mL/m(2) decrease, p=0.03). The preprocedural/intraprocedural factors associated with lower EP-SVi were lower B-SVi (standardised ß [ß] 0.36, p<0.001) atrial fibrillation (ß -0.13, p=0.02) and transapical approach (ß -0.22, p<0.001). CONCLUSIONS: The measurement of EP-SVi is useful to assess the immediate haemodynamic benefit of TAVR and to predict the risk of late mortality.


Assuntos
Estenose da Valva Aórtica/terapia , Valva Aórtica/fisiopatologia , Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Hemodinâmica , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/mortalidade , Distribuição de Qui-Quadrado , Ecocardiografia Doppler , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Estimativa de Kaplan-Meier , Modelos Lineares , Masculino , Análise Multivariada , Valor Preditivo dos Testes , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda
18.
Curr Cardiol Rep ; 17(6): 48, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26003146

RESUMO

The specific flow pattern and imaging features of prosthetic heart valves poses major challenges for the Doppler echocardiographic assessment of prosthetic valve structure and function. A comprehensive approach that integrates several semi-quantitative and quantitative parameters obtained from multiple views is key to appropriately detect and quantitate prosthetic valve dysfunction and complications. In patients with prosthetic valves, and particularly in those with mitral prostheses, transesophageal echocardiography is often required to confirm and/or complement information obtained by transthoracic echocardiography. Three-dimensional echocardiography may provide incremental information for the identification of the underlying etiology of prosthetic valve stenosis or regurgitation. Transcatheter aortic valve implantation has rapidly expanded in the past 10 years and paravalvular regurgitation is frequent following this procedure. Given that paravalvular regurgitant jets are often multiple, irregular, and eccentric, the grading of this type of regurgitation is particularly challenging and requires an integrative multiwindow, multiplane, multiparametric approach.


Assuntos
Ecocardiografia , Doenças das Valvas Cardíacas/diagnóstico por imagem , Próteses Valvulares Cardíacas/efeitos adversos , Próteses Valvulares Cardíacas/estatística & dados numéricos , Constrição Patológica/diagnóstico por imagem , Humanos , Falha de Prótese , Trombose/diagnóstico por imagem , Resultado do Tratamento
19.
Heart ; 101(6): 472-7, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25618481

RESUMO

BACKGROUND: Cusp calcification is the main mechanism leading to bioprosthetic heart valve (BPV) failure. Recent studies suggest that BPV calcification is an active rather than passive process probably modulated by several mechanisms including lipid-mediated inflammation and dysfunctional phosphocalcic metabolism. OBJECTIVE: To identify the clinical and metabolic determinants of BPV calcification assessed by multidetector CT (MDCT). METHODS AND RESULTS: Presence of BPV calcification was assessed by MDCT in 194 patients who had undergone aortic valve replacement. A calcification score was individually calculated and expressed in mm(3). Patients also underwent a clinical evaluation, a Doppler echocardiographic exam, and a plasma lipid and phosphocalcic profile. 46 patients (24%) had BPV calcification (cusp calcification score >0 mm(3)). After adjustment for age, gender, and time interval since BPV implantation, increased calcium-phosphorus product (OR 1.11, 95% CI 1.01 to 1.23 per 1 unit; p=0.02) and the presence of prosthesis-patient mismatch (OR 3.67, 95% CI 1.25 to 10.6; p=0.01) were the strongest independent factors associated with BPV calcification. Calcium supplement intake, age and female gender were independently associated with increased calcium-phosphorus product. CONCLUSIONS: This study suggests that higher calcium-phosphorus product and prosthesis-patient mismatch promote BPV calcification. Furthermore, this study reports that calcium supplements, which are extensively prescribed in elderly patients, are independently associated with higher calcium-phosphorus product.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/patologia , Bioprótese , Calcinose/diagnóstico por imagem , Próteses Valvulares Cardíacas , Tomografia Computadorizada Multidetectores , Complicações Pós-Operatórias/diagnóstico por imagem , Idoso , Valva Aórtica/diagnóstico por imagem , Estudos Transversais , Feminino , Humanos , Masculino , Estudos Prospectivos
20.
Heart ; 101(5): 391-6, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25326443

RESUMO

AIMS: The management of asymptomatic patients with mitral regurgitation (MR) remains controversial. Exercise-induced pulmonary hypertension (ExPHT) was recently reported as a strong predictor of rapid onset of symptoms. We hypothesised that ExPHT is a predictor of postoperative cardiovascular events in patients with primary MR. METHODS AND RESULTS: One hundred and two patients with primary MR, no or mild symptoms (New York heart association (NYHA) ≤2), and no LV dysfunction/dilatation, were prospectively recruited in 3 centres and underwent exercise-stress echocardiography. The presence of ExPHT was defined as an exercise systolic pulmonary arterial pressure >60 mm Hg. All patients were closely followed up and operated on when indication for surgery was reached. Postoperative events were defined as the occurrence of atrial fibrillation (AF), stroke, cardiac-related hospitalisation or death. Among the 102 patients included, 59 developed ExPHT (58%). These patients were significantly older than those without ExPHT (p=0.01). During a mean postoperative follow-up of 50±23 months, 28 patients (26%) experienced a predefined cardiovascular event. Patients with ExPHT had significantly higher rate of postoperative events (39% vs 12%, p=0.005); the rate of events was still higher in these patients (32% vs 9%, p=0.013), even when excluding early postoperative AF (ie, within 48 h). Event-free survival was significantly lower in the ExPHT group (all events: 5-year: 60±8% vs 88±5%, p=0.007, events without early AF: 5-year: 67±7% vs 90±4%, p=0.02). Using Cox multivariable analysis, ExPHT remained independently associated with higher risk of postoperative events in all models (all p≤0.04). CONCLUSIONS: ExPHT is associated with increased risk of adverse cardiac events following mitral valve surgery in patients with primary MR.


Assuntos
Ecocardiografia sob Estresse , Hipertensão Pulmonar/epidemiologia , Insuficiência da Valva Mitral/cirurgia , Complicações Pós-Operatórias/epidemiologia , Fatores Etários , Idoso , Doenças Assintomáticas , Fibrilação Atrial/epidemiologia , Bélgica/epidemiologia , Feminino , Seguimentos , França/epidemiologia , Átrios do Coração/diagnóstico por imagem , Insuficiência Cardíaca/mortalidade , Ventrículos do Coração/diagnóstico por imagem , Hospitalização/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/epidemiologia , Análise Multivariada , Estudos Prospectivos , Quebeque/epidemiologia , Acidente Vascular Cerebral/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA