Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Int J Comput Assist Radiol Surg ; 12(11): 1995-2002, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28488238

RESUMO

PURPOSE: Surgery, chemo- and/or external radiation therapy are the standard therapy options for the treatment of laryngeal cancer. Trans-oral access for the surgery reduces traumata and hospitalization time. A new trend in treatment is organ-preserving surgery. To avoid regrowth of cancer, this type of surgery can be combined with radiation therapy. Since external radiation includes healthy tissue surrounding the cancerous zone, a local and direct intraoral radiation delivery would be beneficial. METHODS: A general concept for a trans-oral radiation system was designed, based on clinical need identification with a medical user. A miniaturized X-ray tube was used as the radiation source for the intraoperative radiation delivery. To reduce dose distribution on healthy areas, the X-ray source was collimated by a newly designed adjustable shielding system as part of the housing. For direct optical visualization of the radiation zone, a miniature flexible endoscope was integrated into the system. The endoscopic light cone and the field of view were aligned with the zone of the collimated radiation. The intraoperative radiation system was mounted on a semi-automatic medical holder that was combined with a frontal actuator for rotational and translational movement using piezoelectric motors to provide precise placement. RESULTS: The entire technical set-up was tested in a simulated environment. The shielding of the X-ray source was verified by performing conventional detector-based dose measurements. The delivered dose was estimated by an ionization chamber. The adjustment of the radiation zone was performed by a manual controlling mechanism integrated into the hand piece of the device. An endoscopic fibre was also added to offer visualization and illumination of the radiation zone. The combination of the radiation system with the semi-automatic holder and actuator offered precise and stable positioning of the device in range of micrometres and will allow for future combination with a radiation planning system. CONCLUSIONS: The presented system was designed for radiation therapy of the oral cavity and the larynx. This first set-up tried to cover all clinical aspects that are necessary for a later use in surgery. The miniaturized X-ray tube offers the size and the power for intraoperative radiation therapy. The adjustable shielding system in combination with the holder and actuator provides a precise placement. The visualization of radiation zone allows a targeting and observation of the radiation zone.


Assuntos
Neoplasias Laríngeas/radioterapia , Laringoscopia/métodos , Procedimentos Cirúrgicos Otorrinolaringológicos , Terapia por Raios X/instrumentação , Desenho de Equipamento , Humanos , Miniaturização , Tratamentos com Preservação do Órgão , Doses de Radiação , Radioterapia/instrumentação , Radioterapia/métodos , Radioterapia Adjuvante , Terapia por Raios X/métodos , Raios X
2.
Phys Med ; 37: 32-36, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28535912

RESUMO

PURPOSE: The current study evaluated the effect of lens-induced high myopia (IHM) on the activity of the occipital visual cortex during two visual stimuli presentations to the subjects. This was done by measuring the Blood Oxygenation Level Dependent (BOLD) signal using functional MRI (fMRI). METHODS: BOLD contrast fMRI was performed with a 1.5T MRI scanner on 12 emmetropic subjects (refractive error <±0.25Diopter) with no history of neurologic disorder. IHM conditions were applied to subjects by three convex lenses of +5D, +7D and +10D. Visual stimuli with 0.34cpd and 1.84cpd spatial frequencies (SF) were presented as a block paradigm to the participants in three IHM states and normal vision state during fMRI data acquisition. Resultant fMRI data were compared among different refractive states. RESULTS: Data analysis showed that IHM did not cause a significant change in the visual cortex activity throughout the presentation of 0.34cpd SF visual stimulus and BOLD signal intensity remained approximately constant (p=0.17). Although, fMRI responses to visual stimuli with spatial frequency of 1.84cpd demonstrated that visual cortex activity was significantly reduced in IHM states compared to normal vision (p=0.01), the results showed no significant differences between three different values of IHM. CONCLUSIONS: This study shows severe blurring caused by lens induced high myopia can decrease BOLD signal intensity depending on the visual stimulus pattern details. However in the low and moderate range of spatial frequencies, blur increment from +5D up to +10D is not associated with further reduction in the BOLD signal of the occipital visual cortex.


Assuntos
Imageamento por Ressonância Magnética , Miopia/fisiopatologia , Córtex Visual/diagnóstico por imagem , Adulto , Feminino , Humanos , Masculino , Estimulação Luminosa , Adulto Jovem
3.
World J Nucl Med ; 16(2): 150-155, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28553183

RESUMO

The main purpose of this study was to investigate dose rate emanating from patients treated with 131I to evaluate which of the theoretical formulas, inverse-square law (ISL) and International Atomic Energy Agency-International Commission on Radiological Protection (IAEA-ICRP) suggested equation, can provide a sufficiently close approximation of the measured dose rate. Measurements were performed based on the IAEA safety report No. 63 method at 0, 12, 24, and 48 h after administration of radioiodine at a distance of 1 m for 69 patients and for the rest of 67 patients, dose rate was measured at 2, 4, 24, and 48 h at a distance of 2 m. Results revealed that the ISL formula gained better approximation of measured dose rates than the IAEA-ICRP equation with the lesser error. The ISL formula is still more reliable than the novel method of dose calculation in the vicinity of patients. This finding reminded us the prime importance of distance as a radiation protection principle.

4.
J Clin Diagn Res ; 11(2): TC08-TC11, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28384957

RESUMO

INTRODUCTION: It is shown that beta-D-glucan is an immunologic system booster with radioprotectory effects. Radioprotectors are chemical components that can alleviate biological damage produced by ionizing radiation. AIM: This study was designed to investigate the synergistic radioprotectory effects of beta-D-glucan and vitamin E on irradiated mice with 60Co source. MATERIALS AND METHODS: A total of 240 female mice were arranged in four, equal population groups of control group (C), treated group with beta D-glucan (G), treated group with vitamin E (E), and treated group with both beta D-glucan and vitamin E (G+E). Each group was divided into three equal population groups of D6, D7 and D8 exposed to 60Co radiation with prescribed total body dose of 6, 7 and 8 Gray (Gy), respectively. After the exposure, the number of survived animals was counted by time, then Lethal Dose50/30 (LD50/30), Lethal Dose50/60 (LD50/60) and Dose Reduction Factor (DRF) were calculated in all groups and corresponding groups. RESULTS: Based on the results of current study, treatment of the animals with vitamin E did not change values of LD50/30 and LD50/60, in comparison to control group. LD50/30 and LD50/60 of treated groups with beta D-glucan and beta D-glucan + vitamin E showed significant difference with those of control group (p<0.01). The DRF values in groups E, G and G + E, were calculated respectively as 1, 1.25 and 1.375 based on LD50/30, and respectively as 1, 1.17 and 1.33 based on LD50/60. While values of DRF in groups G and G + E showed significant difference in comparison to that of control group (p<0.01), but the difference between DRF of groups G and G + E was not significant (p=0.395). CONCLUSION: The findings of study obviously showed that, presence of beta D-glucan in the body of mice, during exposure to ionizing radiation, leads to DRF of higher than one, proving the radioprotectory effect of this agent. Also, we demonstrated that, while vitamin E had no radioprotectory effect on irradiated mice, beta D-glucan in combination with vitamin E increased resistance of mice against ionizing radiation.

5.
Australas Phys Eng Sci Med ; 40(2): 395-400, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28397060

RESUMO

In general, a weighting factor of one is applied for low linear energy transfer radiations. However, several studies indicate that relative biological effectiveness (RBE) of low energy photons and electrons is greater than one. The aim of this current study was calculating the RBE of I-131 radiation relative to Co-60 gamma photons in 100 µm spheroid cells using Monte Carlo (MC) simulations. These calculations were compared to experimentally measured results. MCNPX2.6 was used to simulate the I-131 and Co-60 irradiation setups and calculate the secondary electron spectra at energies higher than 1 keV with varying oxygen concentrations. The electron spectra at energies lower than 1 keV were obtained by extrapolation (down to 10 eV). The calculated electron spectra were input into the MCDS micro-dosimetric Monte Carlo code to calculate the DSB induction and related RBE. The calculated RBE of I-131 radiation relative to Co-60 photons, as the reference radiation recommended by the International Commission on Radiation Protection (ICRP), was 1.06, 1.03 and 1.02 for oxygen concentrations of 0, 5 and 100%, respectively. Results of MC simulations indicate the RBE of I-131 is greater than one. This finding, despite a 10% discrepancy with the findings of the previous in vitro study of one of the authors of this paper, reemphasizes that I-131 radiation induces more severe biological damage than current ICRP recommendations.


Assuntos
Biomarcadores/análise , Dano ao DNA , Radioisótopos do Iodo/química , Método de Monte Carlo , Eficiência Biológica Relativa , Partículas beta , Radioisótopos de Cobalto/química , Simulação por Computador , Raios gama
6.
Mol Imaging Radionucl Ther ; 26(1): 17-23, 2017 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-28291006

RESUMO

OBJECTIVE: Gastroparesis is defined as delayed gastric emptying and is a common medical condition in diabetic patients. Scintigraphy is commonly used as a standard diagnostic procedure for the quantitative assessment of gastroparesis. The aims of this study were to determine an optimum imaging time for the diagnosis of gastroparesis, to assess the prevalence of gastroparesis, to evaluate the correlation between endoscopy and scintigraphy findings as well as the correlation between gastric emptying with patient genders, blood glucose concentration, and functional dyspepsia. METHODS: Gastric emptying was assessed in 50 diabetic patients with a mean age of 50.16 years. For evaluation of gastric emptying, a test meal containing 2 pieces of toast, 120 cc non-labeled water and fried egg labeled with 1 mCi of 99mTc was given to each patient. The scintigraphy was performed immediately after ingestion and was repeated at 1, 1.5, 2 and 4 hours after ingestion. In some patients, an additional 90-minute dynamic scan was also acquired. RESULTS: The prevalence of gastroparesis in this study population was determined as 64%. Also, the results of this study revealed that a 4-hour scan after ingestion is more relevant than a 90-minute dynamic scan for the evaluation of delayed gastric emptying. There was no statistically significant difference between 1-hour and 2-hour scans, 1-hour and 90-minute scans, 2-hour and 90-minute scans, 2-hour and 4-hour scans. Likewise there was no significant correlation between blood glucose levels, gender and calculated values of gastric emptying time in all groups. CONCLUSION: According to our findings, it can be suggested that the prevalence of gastroparesis is higher than that mentioned in some previous studies. Also, this study indicates that a gastric emptying scintigraphy at 2 and 4 hours after meal ingestion might provide the anticipated clinical information in diabetic patients with dyspepsia without other evident reasons.

7.
Clin Nucl Med ; 41(12): 917-921, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27764045

RESUMO

BACKGROUND: Because one of the major sites for metastasis of thyroid cancers is the lung, studying the pattern of pulmonary metastasis may provide useful information for the effective treatment of these patients. In this study, by assessing the metastasis pattern, we aimed to identify the factors that may affect prognosis and response to treatment in patients with differentiated thyroid carcinoma (DTC) with pulmonary metastasis. METHODS: This retrospective study included 75 patients with DTC with pulmonary metastasis who were referred to our nuclear medicine section over a period of 10 years. The data obtained were analyzed with regard to response to treatment to assess the effects of the included factors on prognosis. RESULTS: Of the 1746 patients referred to our section, 75 (4.3%) had pulmonary metastasis. According to the pattern of pulmonary metastasis, they were divided into 4 groups: nodular, diffuse, combined, and other. The mean age of the patients was 43.8 ± 18.5 years. After the follow-up, 58 patients survived, 14 of whom responded to the treatment. The mean number of radioiodine therapy sessions that the patients received was 3.2 ± 2, and the mean cumulative dose was 554.7 ± 387.8 mCi. Statistical analysis of the data revealed that there was no significant difference in the response to treatment between patients with different patterns of pulmonary metastasis (P > 0.3). However, significant differences were reported in the response to treatment between patients with papillary thyroid carcinoma and those with follicular thyroid carcinoma (P < 0.03). The 1-, 5-, and 9-year survival rates were reported as 98%, 76%, and 51%, respectively. CONCLUSIONS: Patients with DTC with pulmonary metastasis have a relatively favorable prognosis and response rate, as well as longer survival. The type of DTC is the only factor that affects the response to treatment.


Assuntos
Adenocarcinoma Folicular/patologia , Carcinoma/patologia , Neoplasias Pulmonares , Neoplasias da Glândula Tireoide/patologia , Adolescente , Adulto , Idoso , Carcinoma Papilar , Feminino , Humanos , Radioisótopos do Iodo/uso terapêutico , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/secundário , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Taxa de Sobrevida , Câncer Papilífero da Tireoide , Neoplasias da Glândula Tireoide/cirurgia , Tireoidectomia , Resultado do Tratamento , Adulto Jovem
8.
Mol Imaging Radionucl Ther ; 25(1): 26-31, 2016 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-27299285

RESUMO

OBJECTIVE: The aim of the current study was to compare 180° and 360° data collection modes to measure end diastolic volume (EDV), end systolic volume (ESV) and ejection fraction (EF) values of the cardiac system by gated myocardial perfusion tomography. METHODS: Thirty-three patients underwent gated myocardial perfusion tomography. Single photon emission computed tomography data of patients' heart were acquired by 180°, 45° left posterior oblique to 45° right anterior oblique, and 360° to obtain EDV, ESV, EF and cardiac volume changes (V1, V2, V3, V4, V5, V6, V7 and V8) throughout each cardiac cycle. RESULTS: Results of the current study indicated that there were no significant differences between 180° and 360° angular sampling in terms of measuring EDV, ESV and EF in myocardial perfusion imaging. Cardiac volume change patterns during a cardiac cycle were also similar in 360° and 180° scans. We also observed that there was no difference in EDV, ESV and EF values between the group with stress induced by exercise and the group with stress imposed by dipyridamole. CONCLUSION: As there is no difference between 180°and 360° cardiac scanning in terms of EDV, ESV and EF, half-orbit scan is recommended to study these cardiac system parameters because it offers more comfort to patients and a shorter scanning time.

9.
J Appl Clin Med Phys ; 17(1): 374-386, 2016 01 08.
Artigo em Inglês | MEDLINE | ID: mdl-26894357

RESUMO

The main purpose of this study was to investigate patient dose in the chest (PA/AP/LAT) and skull (PA/AP/LAT) X-ray examinations, as frequent procedures. The study was performed in eight public hospitals of Khuzestan province, Iran. Patient dosimetry was conducted on 567 standard patient X-ray examinations (males: 61.2%, female: 38.2%). Dosimetry protocol in this study was indirect method, according to the International Atomic Energy Agency (IAEA) Technical Reports series No.457. Patients weighing 70 ± 10 kg were considered as standard. In the indirect dosimetry approach, exposure parameters such as kVp, mAs, focal film distance (FFD), and tube outputs recorded during data acquisition were used for calculating incident air kerma on the patient's skin, entrance surface air kerma (ESAK) that is recommended by the IAEA as the most appropriate patient dosimetry quantity in simple radiographic examinations. This survey reveals significant variations in the radiological practice. Results showed that the parameters set by radiologic technologists change in a wide range: mAs varied from 2 to 80 for skull PA, 2 to 202 for chest LAT, and FFD varied from 50 to 180 for skull LAT projection. The study showed that patient doses in three chest projections exceed the IAEA and European Commission dose reference levels (EC DRLs) - 1.0, 1.12, and 2.20 mGy for chest PA, chest AP, and chest LAT, respectively. Results also showed that mean ESAKs of patients in skull projections were generally lower than the IAEA and EC DRLs, 1.5, 1.72, and 2.25 for skull LAT, skull AP, and skull PA, respectively. This study provides evidence that dose reduction in the simple X-ray examinations is feasible by updating clinical audits and implementation of systematic quality assurance (QA) and quality control (QC) programs. The authors recommend that DRLs obtained in this study can be used as local DRLs in Khuzestan area and dose surveys must be performed in all provinces to establish national dose reference levels (NDRLs) in Iran.


Assuntos
Controle de Qualidade , Proteção Radiológica/normas , Radiografia Torácica/normas , Crânio/diagnóstico por imagem , Feminino , Humanos , Irã (Geográfico) , Doses de Radiação , Raios X
10.
J Environ Health Sci Eng ; 12(1): 4, 2014 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-24393421

RESUMO

BACKGROUND: Present study was an attempt to measure outdoor and indoor gamma dose rates in Bushehr city to determine corresponding annual effective dose and, to assess effect of active nuclear power plant located in Bushehr city on background radiation level of this city. METHODS: All measurements were performed by G.M (Geiger Muller) detector (X5C plus) calibrated in Iran Atomic Energy Agency. In order to avoid effects of ground on outdoor and indoor measurements, G.M detector was placed one meter higher than ground level. Also, during the outdoor measurements, G.M detector was used at least six meters away from the walls of any building nearby to avoid unwanted effects of the materials used in the buildings on measurements. RESULTS: Average gamma dose rates of outdoor and indoor measurements were determined as 51.8 ± 8.8 nSv/h and 60.2 ± 7.2 nSv/h, respectively. Annual effective dose due to background gamma radiation was calculated as 0.36 mSv which was lower than average global level. CONCLUSIONS: The average annual effective dose from background gamma radiation in Bushehr city was less than global level. Comparison of the results of present study, as follow up, with previous attempt performed in 2004 to determine effective dose of environmental gamma radiation in Bushehr province revealed that, during eight years, nuclear power plant located in this city has not significantly increased level of annual effective dose of Bushehr city.

11.
Clin Nucl Med ; 39(3): 232-6, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24458179

RESUMO

PURPOSE: The aim of the present study is to evaluate whether or not the electromagnetic field generated by mobile phones interferes with the function of a SPECT γ-camera during data acquisition. METHODS: We tested the effects of 7 models of mobile phones on 1 SPECT γ-camera. The mobile phones were tested when making a call, in ringing mode, and in standby mode. The γ-camera function was assessed during data acquisition from a planar source and a point source of Tc with activities of 10 mCi and 3 mCi, respectively. A significant visual decrease in count number was considered to be electromagnetic interference (EMI). RESULTS: The percentage of induced EMI with the γ-camera per mobile phone was in the range of 0% to 100%. The incidence of EMI was mainly observed in the first seconds of ringing and then mitigated in the following frames. CONCLUSIONS: Mobile phones are portable sources of electromagnetic radiation, and there is interference potential with the function of SPECT γ-cameras leading to adverse effects on the quality of the acquired images.


Assuntos
Telefone Celular , Campos Eletromagnéticos , Câmaras gama , Tecnécio
12.
Cell J ; 15(3): 224-9, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24027663

RESUMO

OBJECTIVE: To assess relative biological effectiveness (RBE) of (131)I radiation relative to (60)Co gamma rays in glioblastoma spheroid cells. MATERIALS AND METHODS: : In this experimental study, glioblastoma spheroid cells were exposed to (131)I radiation and (60)Co gamma rays. Radiation induced DNA damage was evaluated by alkaline comet assay. Samples of spheroid cells were treated by radiation from (131)I for four different periods of time to find the dose-response equation. Spheroid cells were also exposed by 200 cGy of (60)Co gamma rays as reference radiation to induce DNA damage as endpoint. RESULTS: Resulted RBE of (131)I radiation relative to (60)Co gamma rays in 100 µm giloblastoma spheroid cells was equal to 1.16. CONCLUSION: The finding of this study suggests that (131)I photons and electrons can be more effective than (60)Co gamma rays to produce DNA damage in glioblastoma spheroid cells.

13.
Radiat Prot Dosimetry ; 156(4): 401-6, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23559585

RESUMO

Mobile phones' electromagnetic interference with medical devices is an important issue for the medical safety of patients who are using life-supporting medical devices. This review mainly focuses on mobile phones' interference with implanted medical devices and with medical equipment located in critical areas of hospitals. A close look at the findings reveals that mobile phones may adversely affect the functioning of medical devices, and the specific effect and the degree of interference depend on the applied technology and the separation distance. According to the studies' findings and the authors' recommendations, besides mitigating interference, using mobile phones at a reasonable distance from medical devices and developing technology standards can lead to their effective use in hospital communication systems.


Assuntos
Telefone Celular , Equipamentos e Provisões , Artefatos , Comunicação , Campos Eletromagnéticos , Radiação Eletromagnética , Análise de Falha de Equipamento , Hospitais , Humanos , Sistemas de Manutenção da Vida/instrumentação , Segurança do Paciente , Próteses e Implantes , Tomografia Computadorizada de Emissão de Fóton Único/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA