Masui ; 53(5): 577-84, 2004 May.
Artigo em Japonês | MEDLINE | ID: mdl-15198249

RESUMO

BACKGROUND: Wrong drugs, overdose of drugs, and incorrect administration route remain unsolved problems in anesthetic practice. We determined the incidence and outcome of drug administration error in the operating room of Japanese Society of Anesthesiologists Certified Training Hospitals. METHODS: Data were obtained from annual surveys conducted by Japanese Society of Anesthesiologists between 1999 and 2002. There were 4,291,925 cases of anesthetic delivery for this analysis. RESULTS: Incidence of critical incidents due to drug administration error was 18.27/100,000 anesthetics. Cardiac arrest occurred in 2.21 patients per 100,000 anesthetics. Causes of these critical incidents were as follows: overdose or selection error involving non-anesthetic drugs, 42.1%; overdose of anesthetics, 28.7%; inadvertent high spinal anesthesia, 17.9%; local anesthetic intoxication, 6.4%; ampule or syringe swap, 4.3%; blood mismatch, 0.6%. Incidence of death following these incidents was 0.44/100,000. Causes of death were as follows: overdose or selection error involving non-anesthetic drugs, 47.4%; overdose of anesthetics, 26.3%; inadvertent high spinal anesthesia, 15.8%; local anesthetic intoxication, 5.3%. Ampule or syringe swap did not lead to any fatalities. Death following inadvertent high spinal anesthesia and local anesthetic intoxication was reported only in patients who had developed cardiac arrest. It should be noted that 88 percent of ampule or syringe swap occurred in patients with American Society of Anesthesiologists-Physical Status 1 or 2, who did not seem to require complex anesthetic management. CONCLUSIONS: We should increase awareness that drug administration is generally performed with limited objective monitoring, although "To error is human". Increased vigilance is required to avoid drug administration error in the operating room. Additional anesthesia resident education, adequate supervision, and improved organization are necessary. Bar-coding technology might be useful in preventing drug administration error.


Assuntos
Anestésicos/efeitos adversos , Erros de Medicação/estatística & dados numéricos , Salas Cirúrgicas/estatística & dados numéricos , Anestésicos/administração & dosagem , Overdose de Drogas/epidemiologia , Parada Cardíaca/epidemiologia , Humanos , Incidência , Japão/epidemiologia , Erros de Medicação/prevenção & controle , Gestão da Segurança/estatística & dados numéricos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA