Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
1.
J Vis Exp ; (207)2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38767374

RESUMO

The neuromodulatory effects of focused ultrasound (FUS) have been demonstrated in animal models, and FUS has been used successfully to treat movement and psychiatric disorders in humans. However, despite the success of FUS, the mechanism underlying its effects on neurons remains poorly understood, making treatment optimization by tuning FUS parameters difficult. To address this gap in knowledge, we studied human neurons in vitro using neurons cultured from human-induced pluripotent stem cells (HiPSCs). Using HiPSCs allows for the study of human-specific neuronal behaviors in both physiologic and pathologic states. This report presents a protocol for using a high-throughput system that enables the monitoring and quantification of the neuromodulatory effects of FUS on HiPSC neurons. By varying the FUS parameters and manipulating the HiPSC neurons through pharmaceutical and genetic modifications, researchers can evaluate the neural responses and elucidate the neuro-modulatory effects of FUS on HiPSC neurons. This research could have significant implications for the development of safe and effective FUS-based therapies for a range of neurological and psychiatric disorders.


Assuntos
Células-Tronco Pluripotentes Induzidas , Microeletrodos , Neurônios , Humanos , Neurônios/fisiologia , Neurônios/citologia , Células-Tronco Pluripotentes Induzidas/citologia , Ondas Ultrassônicas
2.
Commun Med (Lond) ; 4(1): 4, 2024 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-38182729

RESUMO

BACKGROUND: Tension in the spinal cord is a trademark of tethered cord syndrome. Unfortunately, existing tests cannot quantify tension across the bulk of the cord, making the diagnostic evaluation of stretch ambiguous. A potential non-destructive metric for spinal cord tension is ultrasound-derived shear wave velocity (SWV). The velocity is sensitive to tissue elasticity and boundary conditions including strain. We use the term Ultrasound Tensography to describe the acoustic evaluation of tension with SWV. METHODS: Our solution Tethered cord Assessment with Ultrasound Tensography (TAUT) was utilized in three sub-studies: finite element simulations, a cadaveric benchtop validation, and a neurosurgical case series. The simulation computed SWV for given tensile forces. The cadaveric model with induced tension validated the SWV-tension relationship. Lastly, SWV was measured intraoperatively in patients diagnosed with tethered cords who underwent treatment (spinal column shortening). The surgery alleviates tension by decreasing the vertebral column length. RESULTS: Here we observe a strong linear relationship between tension and squared SWV across the preclinical sub-studies. Higher tension induces faster shear waves in the simulation (R2 = 0.984) and cadaveric (R2 = 0.951) models. The SWV decreases in all neurosurgical procedures (p < 0.001). Moreover, TAUT has a c-statistic of 0.962 (0.92-1.00), detecting all tethered cords. CONCLUSIONS: This study presents a physical, clinical metric of spinal cord tension. Strong agreement among computational, cadaveric, and clinical studies demonstrates the utility of ultrasound-induced SWV for quantitative intraoperative feedback. This technology is positioned to enhance tethered cord diagnosis, treatment, and postoperative monitoring as it differentiates stretched from healthy cords.


Tethered spinal cord syndrome occurs when surrounding tissue attaches to and causes stretching across the spinal cord. People with a tethered cord can experience weakness, pain, and loss of bladder control. Although increased tension in the spinal cord is known to cause these symptoms, evaluating the amount of stretching remains challenging. We investigated the ability of an ultrasound imaging approach to measure spinal cord tension. We studied our method in a computer simulation, a benchtop validation model, and in six people with tethered cords during surgery that they were undergoing to reduce tension. In each phase, the approach could detect differences between stretched spinal cords and spinal cords in a healthy state. Our method could potentially be used in the future to improve the care of people with a tethered cord.

3.
Sci Rep ; 14(1): 714, 2024 01 06.
Artigo em Inglês | MEDLINE | ID: mdl-38184676

RESUMO

Ultrasound technology can provide high-resolution imaging of blood flow following spinal cord injury (SCI). Blood flow imaging may improve critical care management of SCI, yet its duration is limited clinically by the amount of contrast agent injection required for high-resolution, continuous monitoring. In this study, we aim to establish non-contrast ultrasound as a clinically translatable imaging technique for spinal cord blood flow via comparison to contrast-based methods and by measuring the spatial distribution of blood flow after SCI. A rodent model of contusion SCI at the T12 spinal level was carried out using three different impact forces. We compared images of spinal cord blood flow taken using both non-contrast and contrast-enhanced ultrasound. Subsequently, we processed the images as a function of distance from injury, yielding the distribution of blood flow through space after SCI, and found the following. (1) Both non-contrast and contrast-enhanced imaging methods resulted in similar blood flow distributions (Spearman's ρ = 0.55, p < 0.0001). (2) We found an area of decreased flow at the injury epicenter, or umbra (p < 0.0001). Unexpectedly, we found increased flow at the periphery, or penumbra (rostral, p < 0.05; caudal, p < 0.01), following SCI. However, distal flow remained unchanged, in what is presumably unaffected tissue. (3) Finally, tracking blood flow in the injury zones over time revealed interesting dynamic changes. After an initial decrease, blood flow in the penumbra increased during the first 10 min after injury, while blood flow in the umbra and distal tissue remained constant over time. These results demonstrate the viability of non-contrast ultrasound as a clinical monitoring tool. Furthermore, our surprising observations of increased flow in the injury periphery pose interesting new questions about how the spinal cord vasculature reacts to SCI, with potentially increased significance of the penumbra.


Assuntos
Contusões , Traumatismos da Medula Espinal , Humanos , Traumatismos da Medula Espinal/diagnóstico por imagem , Ultrassonografia , Processamento de Imagem Assistida por Computador
4.
Spine J ; 24(3): 435-445, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37890727

RESUMO

BACKGROUND CONTEXT: The optimal decompression time for patients presenting with acute traumatic central cord syndrome (ATCCS) has been debated, and a high level of evidence is lacking. PURPOSE: To compare early (<24 hours) versus late (≥24 hours) surgical decompression for ATCCS. STUDY DESIGN: Systematic review and meta-analysis. METHODS: Medline, PubMed, Embase, and CENTRAL were searched from inception to March 15th, 2023. The primary outcome was American Spinal Injury Association (ASIA) motor score. Secondary outcomes were venous thromboembolism (VTE), total complications, overall mortality, hospital length of stay (LOS), and ICU LOS. The GRADE approach determined certainty in evidence. RESULTS: The nine studies included reported on 5,619 patients, of whom 2,099 (37.35%) underwent early decompression and 3520 (62.65%) underwent late decompression. The mean age (53.3 vs 56.2 years, p=.505) and admission ASIA motor score (mean difference [MD]=-0.31 [-3.61, 2.98], p=.85) were similar between the early and late decompression groups. At 6-month follow-up, the two groups were similar in ASIA motor score (MD= -3.30 [-8.24, 1.65], p=.19). However, at 1-year follow-up, the early decompression group had a higher ASIA motor score than the late decompression group in total (MD=4.89 [2.89, 6.88], p<.001, evidence: moderate), upper extremities (MD=2.59 [0.82, 4.36], p=.004) and lower extremities (MD=1.08 [0.34, 1.83], p=.004). Early decompression was also associated with lower VTE (odds ratio [OR]=0.41 [0.26, 0.65], p=.001, evidence: moderate), total complications (OR=0.53 [0.42, 0.67], p<.001, evidence: moderate), and hospital LOS (MD=-2.94 days [-3.83, -2.04], p<.001, evidence: moderate). Finally, ICU LOS (MD=-0.69 days [-1.65, 0.28], p=.16, evidence: very low) and overall mortality (OR=1.35 [0.93, 1.94], p=.11, evidence: moderate) were similar between the two groups. CONCLUSIONS: The meta-analysis of these studies demonstrated that early decompression was beneficial in terms of ASIA motor score, VTE, complications, and hospital LOS. Furthermore, early decompression did not increase mortality odds. Although treatment decision-making has been individualized, early decompression should be considered for patients presenting with ATCCS, provided that the surgeon deems it appropriate.


Assuntos
Síndrome Medular Central , Traumatismos da Medula Espinal , Tromboembolia Venosa , Humanos , Pessoa de Meia-Idade , Síndrome Medular Central/cirurgia , Descompressão Cirúrgica/efeitos adversos , Traumatismos da Medula Espinal/cirurgia , Coluna Vertebral/cirurgia
5.
ArXiv ; 2023 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-37808091

RESUMO

While significant advancements in artificial intelligence (AI) have catalyzed progress across various domains, its full potential in understanding visual perception remains underexplored. We propose an artificial neural network dubbed VISION, an acronym for "Visual Interface System for Imaging Output of Neural activity," to mimic the human brain and show how it can foster neuroscientific inquiries. Using visual and contextual inputs, this multimodal model predicts the brain's functional magnetic resonance imaging (fMRI) scan response to natural images. VISION successfully predicts human hemodynamic responses as fMRI voxel values to visual inputs with an accuracy exceeding state-of-the-art performance by 45%. We further probe the trained networks to reveal representational biases in different visual areas, generate experimentally testable hypotheses, and formulate an interpretable metric to associate these hypotheses with cortical functions. With both a model and evaluation metric, the cost and time burdens associated with designing and implementing functional analysis on the visual cortex could be reduced. Our work suggests that the evolution of computational models may shed light on our fundamental understanding of the visual cortex and provide a viable approach toward reliable brain-machine interfaces.

6.
Front Med Technol ; 5: 1238129, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37854637

RESUMO

Tissue elasticity remains an essential biomarker of health and is indicative of irregularities such as tumors or infection. The timely detection of such abnormalities is crucial for the prevention of disease progression and complications that arise from late-stage illnesses. However, at both the bedside and the operating table, there is a distinct lack of tactile feedback for deep-seated tissue. As surgical techniques advance toward remote or minimally invasive options to reduce infection risk and hasten healing time, surgeons lose the ability to manually palpate tissue. Furthermore, palpation of deep structures results in decreased accuracy, with the additional barrier of needing years of experience for adequate confidence of diagnoses. This review delves into the current modalities used to fulfill the clinical need of quantifying physical touch. It covers research efforts involving tactile sensing for remote or minimally invasive surgeries, as well as the potential of ultrasound elastography to further this field with non-invasive real-time imaging of the organ's biomechanical properties. Elastography monitors tissue response to acoustic or mechanical energy and reconstructs an image representative of the elastic profile in the region of interest. This intuitive visualization of tissue elasticity surpasses the tactile information provided by sensors currently used to augment or supplement manual palpation. Focusing on common ultrasound elastography modalities, we evaluate various sensing mechanisms used for measuring tactile information and describe their emerging use in clinical settings where palpation is insufficient or restricted. With the ongoing advancements in ultrasound technology, particularly the emergence of micromachined ultrasound transducers, these devices hold great potential in facilitating early detection of tissue abnormalities and providing an objective measure of patient health.

7.
IEEE Trans Biomed Eng ; 70(7): 1992-2001, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37018313

RESUMO

OBJECTIVE: Here we investigate the ability of low-intensity ultrasound (LIUS) applied to the spinal cord to modulate the transmission of motor signals. METHODS: Male adult Sprague-Dawley rats (n = 10, 250-300 g, 15 weeks old) were used in this study. Anesthesia was initially induced with 2% isoflurane carried by oxygen at 4 L/min via a nose cone. Cranial, upper extremity, and lower extremity electrodes were placed. A thoracic laminectomy was performed to expose the spinal cord at the T11 and T12 vertebral levels. A LIUS transducer was coupled to the exposed spinal cord, and motor evoked potentials (MEPs) were acquired each minute for either 5- or 10-minutes of sonication. Following the sonication period, the ultrasound was turned off and post-sonication MEPs were acquired for an additional 5 minutes. RESULTS: Hindlimb MEP amplitude significantly decreased during sonication in both the 5- (p < 0.001) and 10-min (p = 0.004) cohorts with a corresponding gradual recovery to baseline. Forelimb MEP amplitude did not demonstrate any statistically significant changes during sonication in either the 5- (p = 0.46) or 10-min (p = 0.80) trials. CONCLUSION: LIUS applied to the spinal cord suppresses MEP signals caudal to the site of sonication, with recovery of MEPs to baseline after sonication. SIGNIFICANCE: LIUS can suppress motor signals in the spinal cord and may be useful in treating movement disorders driven by excessive excitation of spinal neurons.


Assuntos
Potencial Evocado Motor , Traumatismos da Medula Espinal , Ratos , Animais , Masculino , Potencial Evocado Motor/fisiologia , Ratos Sprague-Dawley , Medula Espinal/fisiologia , Coluna Vertebral , Potenciais Evocados
8.
J Vis Exp ; (193)2023 03 10.
Artigo em Inglês | MEDLINE | ID: mdl-36971451

RESUMO

Low-intensity focused ultrasound (LIFU) uses ultrasonic pulsations at lower intensities than ultrasound and is being tested as a reversible and precise neuromodulatory technology. Although LIFU-mediated blood-brain barrier (BBB) opening has been explored in detail, no standardized technique for blood-spinal cord barrier (BSCB) opening has been established to date. Therefore, this protocol presents a method for successful BSCB disruption using LIFU sonication in a rat model, including descriptions of animal preparation, microbubble administration, target selection and localization, as well as BSCB disruption visualization and confirmation. The approach reported here is particularly useful for researchers who need a fast and cost-effective method to test and confirm target localization and precise BSCB disruption in a small animal model with a focused ultrasound transducer, evaluate the BSCB efficacy of sonication parameters, or explore applications for LIFU at the spinal cord, such as drug delivery, immunomodulation, and neuromodulation. Optimizing this protocol for individual use is recommended, especially for advancing future preclinical, clinical, and translational work.


Assuntos
Traumatismos da Medula Espinal , Medula Espinal , Ratos , Animais , Medula Espinal/diagnóstico por imagem , Ultrassonografia , Barreira Hematoencefálica/diagnóstico por imagem , Modelos Animais
9.
J Vis Exp ; (192)2023 02 10.
Artigo em Inglês | MEDLINE | ID: mdl-36847383

RESUMO

Sonodynamic therapy (SDT) is an application of focused ultrasound (FUS) that enables a sonosensitizing agent to prime tumors for increased sensitivity during sonication. Unfortunately, current clinical treatments for glioblastoma (GBM) are lacking, leading to low long-term survival rates among patients. SDT is a promising method for treating GBM in an effective, noninvasive, and tumor-specific manner. Sonosensitizers preferentially enter tumor cells compared to the surrounding brain parenchyma. The application of FUS in the presence of a sonosensitizing agent generates reactive oxidative species resulting in apoptosis. Although this therapy has been shown previously to be effective in preclinical studies, there is a lack of established standardized parameters. Standardized methods are necessary to optimize this therapeutic strategy for preclinical and clinical use. In this paper, we detail the protocol to perform SDT in a preclinical GBM rodent model using magnetic resonance-guided FUS (MRgFUS). MRgFUS is an important feature of this protocol, as it allows for specific targeting of a brain tumor without the need for invasive surgeries (e.g., craniotomy). The benchtop device used here can focus on a specific location in three dimensions by clicking on a target on an MRI image, making target selection a straightforward process. This protocol will provide researchers with a standardized preclinical method for MRgFUS SDT, with the added flexibility to change and optimize parameters for translational research.


Assuntos
Neoplasias Encefálicas , Glioblastoma , Terapia por Ultrassom , Camundongos , Animais , Glioblastoma/diagnóstico por imagem , Glioblastoma/terapia , Ultrassonografia , Neoplasias Encefálicas/terapia , Neoplasias Encefálicas/tratamento farmacológico , Encéfalo/patologia , Terapia por Ultrassom/métodos , Linhagem Celular Tumoral
10.
Front Surg ; 9: 1040066, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36532130

RESUMO

Objects accidentally left behind in the brain following neurosurgical procedures may lead to life-threatening health complications and invasive reoperation. One of the most commonly retained surgical items is the cotton ball, which absorbs blood to clear the surgeon's field of view yet in the process becomes visually indistinguishable from the brain parenchyma. However, using ultrasound imaging, the different acoustic properties of cotton and brain tissue result in two discernible materials. In this study, we created a fully automated foreign body object tracking algorithm that integrates into the clinical workflow to detect and localize retained cotton balls in the brain. This deep learning algorithm uses a custom convolutional neural network and achieves 99% accuracy, sensitivity, and specificity, and surpasses other comparable algorithms. Furthermore, the trained algorithm was implemented into web and smartphone applications with the ability to detect one cotton ball in an uploaded ultrasound image in under half of a second. This study also highlights the first use of a foreign body object detection algorithm using real in-human datasets, showing its ability to prevent accidental foreign body retention in a translational setting.

11.
Neurotrauma Rep ; 3(1): 352-368, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36204385

RESUMO

Spinal cord injury (SCI) is a devastating disease with limited effective treatment options. Animal paradigms are vital for understanding the pathogenesis of SCI and testing potential therapeutics. The porcine model of SCI is increasingly favored because of its greater similarity to humans. However, its adoption is limited by the complexities of care and range of testing parameters. Researchers need to consider swine selection, injury method, post-operative care, rehabilitation, behavioral outcomes, and histology metrics. Therefore, we systematically reviewed full-text English-language articles to evaluate study characteristics used in developing a porcine model and summarize the interventions that have been tested using this paradigm. A total of 63 studies were included, with 33 examining SCI pathogenesis and 30 testing interventions. Studies had an average sample size of 15 pigs with an average weight of 26 kg, and most used female swine with injury to the thoracic cord. Injury was most commonly induced by weight drop with compression. The porcine model is amenable to testing various interventions, including mean arterial pressure augmentation (n = 7), electrical stimulation (n = 6), stem cell therapy (n = 5), hypothermia (n = 2), biomaterials (n = 2), gene therapy (n = 2), steroids (n = 1), and nanoparticles (n = 1). It is also notable for its clinical translatability and is emerging as a valuable pre-clinical study tool. This systematic review can serve as a guideline for researchers implementing and testing the porcine SCI model.

12.
Cancers (Basel) ; 14(19)2022 Oct 08.
Artigo em Inglês | MEDLINE | ID: mdl-36230843

RESUMO

Glioblastoma (GBM) is an aggressive primary astrocytoma associated with short overall survival. Treatment for GBM primarily consists of maximal safe surgical resection, radiation therapy, and chemotherapy using temozolomide. Nonetheless, recurrence and tumor progression is the norm, driven by tumor stem cell activity and a high mutational burden. Focused ultrasound (FUS) has shown promising results in preclinical and clinical trials for treatment of GBM and has received regulatory approval for the treatment of other neoplasms. Here, we review the range of applications for FUS in the treatment of GBM, which depend on parameters, including frequency, power, pulse duration, and duty cycle. Low-intensity FUS can be used to transiently open the blood-brain barrier (BBB), which restricts diffusion of most macromolecules and therapeutic agents into the brain. Under guidance from magnetic resonance imaging, the BBB can be targeted in a precise location to permit diffusion of molecules only at the vicinity of the tumor, preventing side effects to healthy tissue. BBB opening can also be used to improve detection of cell-free tumor DNA with liquid biopsies, allowing non-invasive diagnosis and identification of molecular mutations. High-intensity FUS can cause tumor ablation via a hyperthermic effect. Additionally, FUS can stimulate immunological attack of tumor cells, can activate sonosensitizers to exert cytotoxic effects on tumor tissue, and can sensitize tumors to radiation therapy. Finally, another mechanism under investigation, known as histotripsy, produces tumor ablation via acoustic cavitation rather than thermal effects.

13.
J Clin Neurosci ; 104: 18-28, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35933785

RESUMO

Elastography is an imaging technology capable of measuring tissue stiffness and consistency. The technology has achieved widespread use in the workup and management of diseases of the liver, breast, thyroid, and prostate. Although elastography is increasingly being applied in neurosurgery, it has not yet achieved widespread adoption and many clinicians remain unfamiliar with the technology. Therefore, we sought to summarize the range of applications and elastography modalities available for neurosurgery, report its effectiveness in comparison with conventional imaging methods, and offer recommendations. All full-text English-language manuscripts on the use of elastography for neurosurgical procedures were screened using the PubMed/MEDLINE, Embase, Cochrane Library, Scopus, and Web of Science databases. Thirty-two studies were included with 990 patients, including 21 studies on intracranial tumors, 5 on hydrocephalus, 4 on epilepsy, 1 on spinal cord compression, and 1 on adolescent scoliosis. Twenty studies used ultrasound elastography (USE) whereas 12 used magnetic resonance elastography (MRE). MRE studies were mostly used in the preoperative setting for assessment of lesion stiffness, tumor-brain adherence, diagnostic workup, and operative planning. USE studies were performed intraoperatively to guide resection of lesions, determine residual microscopic abnormalities, assess the tumor-brain interface, and study mechanical properties of tumors. Elastography can assist with resection of brain tissue, detection of microscopic lesions, and workup of hydrocephalus, among other applications under investigation. Its sensitivity often exceeds that of conventional MRI and ultrasound for identifying abnormal tissue and lesion margins.


Assuntos
Técnicas de Imagem por Elasticidade , Hidrocefalia , Neurocirurgia , Adolescente , Técnicas de Imagem por Elasticidade/métodos , Humanos , Hidrocefalia/diagnóstico por imagem , Hidrocefalia/cirurgia , Imageamento por Ressonância Magnética/métodos , Masculino , Procedimentos Neurocirúrgicos
14.
Microcirculation ; 29(6-7): e12770, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35611457

RESUMO

OBJECTIVE: Monitoring microcirculation and visualizing microvasculature are critical for providing diagnosis to medical professionals and guiding clinical interventions. Ultrasound provides a medium for monitoring and visualization; however, there are challenges due to the complex microscale geometry of the vasculature and difficulties associated with quantifying perfusion. Here, we studied established and state-of-the-art ultrasonic modalities (using six probes) to compare their detection of slow flow in small microvasculature. METHODS: Five ultrasonic modalities were studied: grayscale, color Doppler, power Doppler, superb microvascular imaging (SMI), and microflow imaging (MFI), using six linear probes across two ultrasound scanners. Image readability was blindly scored by radiologists and quantified for evaluation. Vasculature visualization was investigated both in vitro (resolution and flow characterization) and in vivo (fingertip microvasculature detection). RESULTS: Superb Microvascular Imaging (SMI) and Micro Flow Imaging (MFI) modalities provided superior images when compared with conventional ultrasound imaging modalities both in vitro and in vivo. The choice of probe played a significant difference in detectability. The slowest flow detected (in the lab) was 0.1885 ml/s and small microvasculature of the fingertip were visualized. CONCLUSIONS: Our data demonstrated that SMI and MFI used with vascular probes operating at higher frequencies provided resolutions acceptable for microvasculature visualization, paving the path for future development of ultrasound devices for microcirculation monitoring.


Assuntos
Microvasos , Ultrassonografia Doppler , Microcirculação , Ultrassonografia/métodos , Microvasos/diagnóstico por imagem , Ultrassonografia Doppler/métodos
15.
Spine J ; 22(8): 1372-1387, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35351667

RESUMO

Spinal cord injury (SCI) is a devastating condition that affects about 17,000 individuals every year in the United States, with approximately 294,000 people living with the ramifications of the initial injury. After the initial primary injury, SCI has a secondary phase during which the spinal cord sustains further injury due to ischemia, excitotoxicity, immune-mediated damage, mitochondrial dysfunction, apoptosis, and oxidative stress. The multifaceted injury progression process requires a sophisticated injury-monitoring technique for an accurate assessment of SCI patients. In this narrative review, we discuss SCI monitoring modalities, including pressure probes and catheters, micro dialysis, electrophysiologic measures, biomarkers, and imaging studies. The optimal next-generation injury monitoring setup should include multiple modalities and should integrate the data to produce a final simplified assessment of the injury and determine markers of intervention to improve patient outcomes.


Assuntos
Traumatismos da Medula Espinal , Apoptose , Biomarcadores , Humanos , Estresse Oxidativo , Medula Espinal , Traumatismos da Medula Espinal/complicações
17.
IEEE Biomed Circuits Syst Conf ; 2022: 610-614, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36695674

RESUMO

Imaging of spinal cord microvasculature holds great potential in directing critical care management of spinal cord injury (SCI). Traditionally, contrast agents are preferred for imaging of the spinal cord vasculature, which is disadvantageous for long-term monitoring of injury. Here, we present FlowMorph, an algorithm that uses mathematical morphology techniques to segment non-contrast Doppler-based videos of rat spinal cord. Using the segmentation, it measures single-vessel parameters such as flow velocity, rate, and radius, with visible cardiac cycles in individual vessels showcasing the spatiotemporal resolution. The segmentation outlines vessels well with little extraneous labeling, and outlines are smooth through time. Radius measurements of perforating vessels are similar to what is seen in the literature through other methods. Verification of the algorithm through comparison to manual measurement and in vitro microphantom standards highlights points of future improvement. This method will be vital for future work studying the vascular effects of SCI and can be adopted to other species as well.

18.
Front Oncol ; 12: 1072780, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36873300

RESUMO

Glioblastoma multiforme (GBM) is a deadly and aggressive malignant brain cancer that is highly resistant to treatments. A particular challenge of treatment is caused by the blood-brain barrier (BBB), the relatively impermeable vasculature of the brain. The BBB prevents large molecules from entering the brain parenchyma. This protective characteristic of the BBB, however, also limits the delivery of therapeutic drugs for the treatment of brain tumors. To address this limitation, focused ultrasound (FUS) has been safely utilized to create transient openings in the BBB, allowing various high molecular weight drugs access to the brain. We performed a systematic review summarizing current research on treatment of GBMs using FUS-mediated BBB openings in in vivo mouse and rat models. The studies gathered here highlight how the treatment paradigm can allow for increased brain and tumor perfusion of drugs including chemotherapeutics, immunotherapeutics, gene therapeutics, nanoparticles, and more. Given the promising results detailed here, the aim of this review is to detail the commonly used parameters for FUS to open the BBB in rodent GBM models.

19.
Front Public Health ; 9: 541191, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34660499

RESUMO

For-profit biotechnological and pharmaceutical companies have played an essential role in the research and development (R&D) of innovative medical products and drugs for many decades and embody a trillion-dollar industry. The past decades have been marked by an increase in growth of social non-profit biotechnology companies and organizations led by entrepreneurs committed to solve (global) health issues. In this review, we define the concept of social bioentrepreneurship and consider the potential impact of such ventures on global health. We analyse the current status of non-profit biotechnology and clarify the strategy, motivation, funding, and marketing techniques of these enterprises. We find that these non-profit ventures mainly focus on neglected and rare diseases by using different but also similar funding, marketing, and business strategy approaches to for-profit biotechnology enterprises. We also identify good leadership, multidisciplinary teams, and public awareness as key components to achieve long-term survival and higher success rates. Challenges faced by bioentrepreneurs include the lack of a clearly defined regulatory environment or governmental incentives to support their endeavors. Overall, with this qualitative data review and market analysis we draw a promising picture of social non-profit bioentrepreneurship and underscore its current and future impact on global health issues.


Assuntos
Saúde Global , Organizações sem Fins Lucrativos , Biotecnologia , Comércio
20.
Neurosurgery ; 89(3): 372-382, 2021 08 16.
Artigo em Inglês | MEDLINE | ID: mdl-34098572

RESUMO

Traumatic spinal cord injury (SCI) is a common and devastating condition. In the absence of effective validated therapies, there is an urgent need for novel methods to achieve injury stabilization, regeneration, and functional restoration in SCI patients. Ultrasound is a versatile platform technology that can provide a foundation for viable diagnostic and therapeutic interventions in SCI. In particular, real-time perfusion and inflammatory biomarker monitoring, focal pharmaceutical delivery, and neuromodulation are capabilities that can be harnessed to advance our knowledge of SCI pathophysiology and to develop novel management and treatment options. Our review suggests that studies that evaluate the benefits and risks of ultrasound in SCI are severely lacking and our understanding of the technology's potential impact remains poorly understood. Although the complex anatomy and physiology of the spine and the spinal cord remain significant challenges, continued technological advances will help the field overcome the current barriers and bring ultrasound to the forefront of SCI research and development.


Assuntos
Traumatismos da Medula Espinal , Humanos , Medula Espinal , Traumatismos da Medula Espinal/diagnóstico por imagem , Traumatismos da Medula Espinal/terapia , Coluna Vertebral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA