1.
Echocardiography ; 34(7): 956-967, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28573718

RESUMO

BACKGROUND: Correctly selecting the end-diastolic and end-systolic frames on a 2D echocardiogram is important and challenging, for both human experts and automated algorithms. Manual selection is time-consuming and subject to uncertainty, and may affect the results obtained, especially for advanced measurements such as myocardial strain. METHODS AND RESULTS: We developed and evaluated algorithms which can automatically extract global and regional cardiac velocity, and identify end-diastolic and end-systolic frames. We acquired apical four-chamber 2D echocardiographic video recordings, each at least 10 heartbeats long, acquired twice at frame rates of 52 and 79 frames/s from 19 patients, yielding 38 recordings. Five experienced echocardiographers independently marked end-systolic and end-diastolic frames for the first 10 heartbeats of each recording. The automated algorithm also did this. Using the average of time points identified by five human operators as the reference gold standard, the individual operators had a root mean square difference from that gold standard of 46.5 ms. The algorithm had a root mean square difference from the human gold standard of 40.5 ms (P<.0001). Put another way, the algorithm-identified time point was an outlier in 122/564 heartbeats (21.6%), whereas the average human operator was an outlier in 254/564 heartbeats (45%). CONCLUSION: An automated algorithm can identify the end-systolic and end-diastolic frames with performance indistinguishable from that of human experts. This saves staff time, which could therefore be invested in assessing more beats, and reduces uncertainty about the reliability of the choice of frame.


Assuntos
Ecocardiografia/métodos , Coração/diagnóstico por imagem , Coração/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Diástole , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sístole
2.
Int J Cardiovasc Imaging ; 33(8): 1135-1148, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28220275

RESUMO

Current guidelines for measuring cardiac function by tissue Doppler recommend using multiple beats, but this has a time cost for human operators. We present an open-source, vendor-independent, drag-and-drop software capable of automating the measurement process. A database of ~8000 tissue Doppler beats (48 patients) from the septal and lateral annuli were analyzed by three expert echocardiographers. We developed an intensity- and gradient-based automated algorithm to measure tissue Doppler velocities. We tested its performance against manual measurements from the expert human operators. Our algorithm showed strong agreement with expert human operators. Performance was indistinguishable from a human operator: for algorithm, mean difference and SDD from the mean of human operators' estimates 0.48 ± 1.12 cm/s (R2 = 0.82); for the humans individually this was 0.43 ± 1.11 cm/s (R2 = 0.84), -0.88 ± 1.12 cm/s (R2 = 0.84) and 0.41 ± 1.30 cm/s (R2 = 0.78). Agreement between operators and the automated algorithm was preserved when measuring at either the edge or middle of the trace. The algorithm was 10-fold quicker than manual measurements (p < 0.001). This open-source, vendor-independent, drag-and-drop software can make peak velocity measurements from pulsed wave tissue Doppler traces as accurately as human experts. This automation permits rapid, bias-resistant multi-beat analysis from spectral tissue Doppler images.


Assuntos
Algoritmos , Técnicas de Imagem de Sincronização Cardíaca , Ecocardiografia Doppler de Pulso/métodos , Cardiopatias/diagnóstico por imagem , Frequência Cardíaca , Interpretação de Imagem Assistida por Computador/métodos , Software , Idoso , Automação , Feminino , Cardiopatias/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Contração Miocárdica , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Função Ventricular Esquerda