Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
2.
Med Biol Eng Comput ; 60(2): 583-598, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35029812

RESUMO

Free-breathing external beam radiotherapy remains challenging due to the complex elastic or irregular motion of abdominal organs, as imaging moving organs leads to the creation of motion blurring artifacts. In this paper, we propose a radial-based MRI reconstruction method from 3D free-breathing abdominal data using spatio-temporal geodesic trajectories, to quantify motion during radiotherapy. The prospective study was approved by the institutional review board and consent was obtained from all participants. A total of 25 healthy volunteers, 12 women and 13 men (38 years ± 12 [standard deviation]), and 11 liver cancer patients underwent imaging using a 3.0 T clinical MRI system. The radial acquisition based on golden-angle sparse sampling was performed using a 3D stack-of-stars gradient-echo sequence and reconstructed using a discretized piecewise spatio-temporal trajectory defined in a low-dimensional embedding, which tracks the inhale and exhale phases, allowing the separation between distinct motion phases. Liver displacement between phases as measured with the proposed radial approach based on the deformation vector fields was compared to a navigator-based approach. Images reconstructed with the proposed technique with 20 motion states and registered with the multiscale B-spline approach received on average the highest Likert scores for the overall image quality and visual SNR score 3.2 ± 0.3 (mean ± standard deviation), with liver displacement errors varying between 0.1 and 2.0 mm (mean 0.8 ± 0.6 mm). When compared to navigator-based approaches, the proposed method yields similar deformation vector field magnitudes and angle distributions, and with improved reconstruction accuracy based on mean squared errors. Schematic illustration of the proposed 4D-MRI reconstruction method based on radial golden-angle acquisitions and a respiration motion model from a manifold embedding used for motion tracking. First, data is extracted from the center of k-space using golden-angle sampling, which is then mapped onto a low-dimensional embedding, describing the relationship between neighboring samples in the breathing cycle. The trained model is then used to extract the respiratory motion signal for slice re-ordering. The process then improves the image quality through deformable image registration. Using a reference volume, the deformation vector field (DVF) of sequential motion states are extracted, followed by deformable registrations. The output is a 4DMRI which allows to visualize and quantify motion during free-breathing.


Assuntos
Imageamento Tridimensional , Respiração , Artefatos , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Movimento (Física) , Estudos Prospectivos
3.
PLoS One ; 16(12): e0259692, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34874934

RESUMO

Magnetic resonance imaging (MRI) plays a critical role in the planning and monitoring of hepatocellular carcinomas (HCC) treated with locoregional therapies, in order to assess disease progression or recurrence. Dynamic contrast-enhanced (DCE)-MRI sequences offer temporal data on tumor enhancement characteristics which has strong prognostic value. Yet, predicting follow-up DCE-MR images from which tumor enhancement and viability can be measured, before treatment of HCC actually begins, remains an unsolved problem given the complexity of spatial and temporal information. We propose an approach to predict future DCE-MRI examinations following transarterial chemoembolization (TACE) by learning the spatio-temporal features related to HCC response from pre-TACE images. A novel Spatial-Temporal Discriminant Graph Neural Network (STDGNN) based on graph convolutional networks is presented. First, embeddings of viable, equivocal and non-viable HCCs are separated within a joint low-dimensional latent space, which is created using a discriminant neural network representing tumor-specific features. Spatial tumoral features from independent MRI volumes are then extracted with a structural branch, while dynamic features are extracted from the multi-phase sequence with a separate temporal branch. The model extracts spatio-temporal features by a joint minimization of the network branches. At testing, a pre-TACE diagnostic DCE-MRI is embedded on the discriminant spatio-temporal latent space, which is then translated to the follow-up domain space, thus allowing to predict the post-TACE DCE-MRI describing HCC treatment response. A dataset of 366 HCC's from liver cancer patients was used to train and test the model using DCE-MRI examinations with associated pathological outcomes, with the spatio-temporal framework yielding 93.5% classification accuracy in response identification, and generating follow-up images yielding insignificant differences in perfusion parameters compared to ground-truth post-TACE examinations.


Assuntos
Carcinoma Hepatocelular/terapia , Quimioembolização Terapêutica/métodos , Neoplasias Hepáticas/terapia , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Idoso , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Análise Espaço-Temporal , Resultado do Tratamento
4.
Med Image Anal ; 74: 102250, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34601453

RESUMO

Shape and location organ variability induced by respiration constitutes one of the main challenges during dose delivery in radiotherapy. Providing up-to-date volumetric information during treatment can improve tumor tracking, thereby increasing treatment efficiency and reducing damage to healthy tissue. We propose a novel probabilistic model to address the problem of volumetric estimation with scalable predictive horizon from image-based surrogates during radiotherapy treatments, thus enabling out-of-plane tracking of targets. This problem is formulated as a conditional learning task, where the predictive variables are the 2D surrogate images and a pre-operative static 3D volume. The model learns a distribution of realistic motion fields over a population dataset. Simultaneously, a seq-2-seq inspired temporal mechanism acts over the surrogate images yielding extrapolated-in-time representations. The phase-specific motion distributions are associated with the predicted temporal representations, allowing the recovery of dense organ deformation in multiple times. Due to its generative nature, this model enables uncertainty estimations by sampling the latent space multiple times. Furthermore, it can be readily personalized to a new subject via fine-tuning, and does not require inter-subject correspondences. The proposed model was evaluated on free-breathing 4D MRI and ultrasound datasets from 25 healthy volunteers, as well as on 11 cancer patients. A navigator-based data augmentation strategy was used during the slice reordering process to increase model robustness against inter-cycle variability. The patient data was used as a hold-out test set. Our approach yields volumetric prediction from image surrogates with a mean error of 1.67 ± 1.68 mm and 2.17 ± 0.82 mm in unseen cases of the patient MRI and US datasets, respectively. Moreover, model personalization yields a mean landmark error of 1.4 ± 1.1 mm compared to ground truth annotations in the volunteer MRI dataset, with statistically significant improvements over state-of-the-art.


Assuntos
Radioterapia Guiada por Imagem , Humanos , Imageamento por Ressonância Magnética , Modelos Estatísticos , Respiração , Ultrassonografia
5.
Int J Comput Assist Radiol Surg ; 16(7): 1213-1225, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34114173

RESUMO

PURPOSE: Respiratory motion of thoracic organs poses a severe challenge for the administration of image-guided radiotherapy treatments. Providing online and up-to-date volumetric information during free breathing can improve target tracking, ultimately increasing treatment efficiency and reducing toxicity to surrounding healthy tissue. In this work, a novel population-based generative network is proposed to address the problem of 3D target location prediction from 2D image-based surrogates during radiotherapy, thus enabling out-of-plane tracking of treatment targets using images acquired in real time. METHODS: The proposed model is trained to simultaneously create a low-dimensional manifold representation of 3D non-rigid deformations and to predict, ahead of time, the motion of the treatment target. The predictive capabilities of the model allow correcting target location errors that can arise due to system latency, using only a baseline volume of the patient anatomy. Importantly, the method does not require supervised information such as ground-truth registration fields, organ segmentation, or anatomical landmarks. RESULTS: The proposed architecture was evaluated on both free-breathing 4D MRI and ultrasound datasets. Potential challenges present in a realistic therapy, like different acquisition protocols, were taken into account by using an independent hold-out test set. Our approach enables 3D target tracking from single-view slices with a mean landmark error of 1.8 mm, 2.4 mm and 5.2 mm in volunteer MRI, patient MRI and US datasets, respectively, without requiring any prior subject-specific 4D acquisition. CONCLUSIONS: This model presents several advantages over state-of-the-art approaches. Namely, it benefits from an explainable latent space with explicit respiratory phase discrimination. Thanks to the strong generalization capabilities of neural networks, it does not require establishing inter-subject correspondences. Once trained, it can be quickly deployed with an inference time of only 8 ms. The results show the capability of the network to predict future anatomical changes and track tumors in real time, yielding statistically significant improvements over related methods.


Assuntos
Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Redes Neurais de Computação , Radioterapia Guiada por Imagem/métodos , Neoplasias Torácicas/radioterapia , Ultrassonografia/métodos , Humanos , Respiração , Neoplasias Torácicas/diagnóstico
6.
Phys Med Biol ; 65(8): 085004, 2020 04 17.
Artigo em Inglês | MEDLINE | ID: mdl-32084661

RESUMO

This paper presents a prospective study evaluating the impact on image quality and quantitative dynamic contrast-enhanced (DCE)-MRI perfusion parameters when varying the number of respiratory motion states when using an eXtra-Dimensional Golden-Angle Radial Sparse Parallel (XD-GRASP) MRI sequence. DCE acquisition was performed using a 3D stack-of-stars gradient-echo golden-angle radial acquisition in free-breathing with 100 spokes per motion state and temporal resolution of 6 s/volume, and using a non-rigid motion compensation to align different motion states. Parametric analysis was conducted using a dual-input single-compartment model. Nonparametric analysis was performed on the time-intensity curves. A total of 22 hepatocellular carcinomas (size: 11-52 mm) were evaluated. XD-GRASP reconstructed with increasing number of spokes for each motion state increased the signal-to-noise ratio (SNR) (p < 0.05) but decreased temporal resolution (0.04 volume/s vs 0.17 volume/s for one motion state) (p < 0.05). A visual scoring by an experienced radiologist show no change between increasing number of motion states with same number of spokes using the Likert score. The normalized maximum intensity time ratio, peak enhancement ratio and tumor arterial fraction increased with decreasing number of motion states (p < 0.05) while the transfer constant from the portal venous plasma to the surrounding tissue significantly decreased (p < 0.05). These same perfusion parameters show a significant difference in case of tumor displacement more than 1 cm (p < 0.05) whereas in the opposite case there was no significant variation. While a higher number of motion states and higher number of spokes improves SNR, the resulting lower temporal resolution can influence quantitative parameters that capture rapid signal changes. Finally, fewer displacement compensation is advantageous with lower number of motion state due to the higher temporal resolution. XD-GRASP can be used to perform quantitative perfusion measures in the liver, but the number of motion states may significantly alter some quantitative parameters.


Assuntos
Meios de Contraste , Processamento de Imagem Assistida por Computador/métodos , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética , Movimento , Humanos , Masculino , Estudos Prospectivos , Respiração , Razão Sinal-Ruído , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA