Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Acta Biomed ; 92(6): e2021221, 2022 01 19.
Artigo em Inglês | MEDLINE | ID: mdl-35075078

RESUMO

BACKGROUND AND AIM: Three-dimensional (3D) printing is prevailing in surgical planning of complex cases. The aim of this study is to describe the use of 3D printed models during the surgical planning for the treatment of four pediatric hip deformity cases. Moreover, pediatric pelvic deformities analyzed by 3D printed models have been object of a concise review. METHODS: All treated patients were females, with an average age of 5 years old. Patients' dysplastic pelvises were 3D-printed in real scale using processed files from Computed Tomography (CT) or Magnetic Resonance Imaging (MRI). Data about 3D printing, surgery time, blood loss and fluoroscopy have been recorded. RESULTS: The Zanoli-Pemberton or Ganz-Paley osteotomies were performed on the four 3D printed models, then the real surgery was performed in the operating room. Time and costs to produce 3D printed models were respectively on average 17:26 h and 34.66 €. The surgical duration took about 87.5 min while the blood loss average was 1.9 ml/dl. Fluoroscopy time was 21 sec. MRI model resulted inaccurate and more difficult to produce. 10 papers have been selected for the concise literature review. CONCLUSIONS: 3D printed models have proved themselves useful in the reduction of surgery time, blood loss and ionizing radiation, as well as they have improved surgical outcomes. 3D printed model is a valid tool to deepen the complex anatomy and orientate surgical choices by allowing surgeons to carefully plan the surgery.


Assuntos
Procedimentos de Cirurgia Plástica , Impressão Tridimensional , Criança , Pré-Escolar , Feminino , Humanos , Imageamento por Ressonância Magnética , Osteotomia , Tomografia Computadorizada por Raios X
2.
Radiol Technol ; 93(3): 246-254, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-35017268

RESUMO

PURPOSE: To evaluate the accuracy of 3-D printed models of the femoral head based on preoperative computed tomography (CT) images. Other goals were to compare the cartilage thickness of bony specimen to the printed models and calculate the standard deviation between 3-D printed models based on CT images and laser scan models. METHODS: This retrospective study analyzed 10 patients who underwent preoperative CT imaging and hip replacement. Preoperative femoral head 3-D printed models were produced from CT images. Bony specimens were collected from surgical operations and scanned using CT and 3-D laser scanning, and cartilage thickness subsequently was measured by histological analysis. Comparisons of printed models based on CT images and printed models based on 3-D laser scanning were performed by overlapping their external surfaces using dedicated software and the standard deviation was calculated. RESULTS: The average standard deviation between the bony specimen 3-D models and preoperative 3-D printed CT femoral head models was 0.651 mm. The cartilage was approximately 1.487 mm thick. DISCUSSION: The comparison between preoperative CT image-based 3-D models and the postoperative bony specimen-based models permitted evaluation of the accuracy of preoperative CT image-based 3-D printed models. Cartilage thickness was estimated indirectly by comparing models obtained by CT and laser scanning, and it was related to the calculated standard deviation to overcome the cartilage detection limit of CT. This study shows how each step can generate accuracy errors on the final 3-D printed model. A repeatable and sustainable workflow for creating accurate and reproducible 3-D printed models could overcome this issue. Moreover, orthopedic surgeons should be aware of 3-D printed model precision in clinical practice. CONCLUSIONS: This study provides encouraging results on the accuracy of 3-D printed models for surgical planning.


Assuntos
Impressão Tridimensional , Tomografia Computadorizada por Raios X , Fêmur , Humanos , Imageamento Tridimensional , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
3.
Radiol Med ; 125(2): 117-127, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31686317

RESUMO

PURPOSE: To compare measured radiation dose (MD), estimated radiation dose (ED) and image quality in coronary computed tomography between turbo-flash (TFP) and retrospective protocol (RP) and correlate MD with size-specific dose estimates (SSDE). MATERIALS AND METHODS: In this prospective study, we selected 68 patients (mean age, 59.2 ± 9.7 years) undergoing 192 × 2 dual-source CT (SOMATOM Force, Siemens) to rule out coronary artery disease. Thirty-one underwent TFP and 37 RP. To evaluate in vivo MD, thermoluminescent dosimeters were placed, superficially, at thyroid and heart level, left breast areola and left hemi-thorax. MD in each site, and ED parameters, such as volume CT dose index (CTDIvol), SSDE, dose length product (DLP), effective dose (E), were compared between two protocols with a t test. Image quality was compared between two protocols. Inter-observer agreement was evaluated with a kappa coefficient (k). In each protocol, MD was correlated with SSDE using a Pearson coefficient (r). RESULTS: Comparing TFP and RP, MD at thyroid (1.43 vs. 2.58 mGy; p = 0.0408), heart (3.58 vs. 28.72 mGy; p < 0.0001), left breast areola (3.00 vs. 24.21 mGy; p < 0.0001) and left hemi-thorax (2.68 vs. 24.03 mGy; p < 0.0001), CTDIvol, SSDE, DLP and E were significantly lower. Differences in image quality were not statistically significant. Inter-observer agreement was good (k = 0.796) in TFP and very good (k = 0.817) in RP. MD and SSDE excellently correlated with TFP (r = 0.9298, p < 0.0001) and RP (r = 0.9753, p < 0.0001). CONCLUSIONS: With TFP, MD, CTDIvol, SSDE, DLP and E were significantly lower, than with RP. Image quality was similar between two protocols. MD correlated excellently with SSDE in each protocol.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doses de Radiação , Meios de Contraste , Feminino , Humanos , Iopamidol , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Interpretação de Imagem Radiográfica Assistida por Computador , Dosimetria Termoluminescente
4.
Radiol Med ; 124(12): 1281-1295, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31792703

RESUMO

The physical principles of dual-energy computed tomography (DECT) are as old as computed tomography (CT) itself. To understand the strengths and the limits of this technology, a brief overview of theoretical basis of DECT will be provided. Specific attention will be focused on the interaction of X-rays with matter, on the principles of attenuation of X-rays in CT toward the intrinsic limits of conventional CT, on the material decomposition algorithms (two- and three-basis-material decomposition algorithms) and on effective Rho-Z methods. The progresses in material decomposition algorithms, in computational power of computers and in CT hardware, lead to the development of different technological solutions for DECT in clinical practice. The clinical applications of DECT are briefly reviewed in relation to the specific algorithms.


Assuntos
Algoritmos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tecnologia Radiológica/métodos , Tomografia Computadorizada por Raios X/métodos , Feminino , Humanos , Masculino , Espalhamento de Radiação , Raios X
5.
Radiol Med ; 124(8): 753-761, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31011995

RESUMO

PURPOSE: To compare radiation exposure associated with daily practice cardiovascular (CV) examinations performed on two different multidetector computed tomography (MDCT) scanners, a conventional 64-MDCT and a third-generation dual-source (DS) MDCT. MATERIALS AND METHODS: In this retrospective study, 1458 patients who underwent CV examinations between January 2017 and August 2018 were enrolled. A single-source 64-MDCT (Lightspeed VCT, GE) scan was performed in 705 patients from January to August 2017 (207 coronary examinations and 498 vascular examinations) and 753 patients underwent third-generation 192 × 2-DSCT (Somatom FORCE, Siemens) scan from January to August 2018 (302 coronary examinations and 451 vascular examinations). Volume CT dose index (CTDIvol), dose length product (DLP), effective dose (ED), tube voltage (TV) and exposure time (ET), pitch factor (PF) were registered for each patient. Student's t test was used to compare mean values between each corresponding group of MDCT and DSCT. RESULTS: In coronary examinations with DSCT, CTDIvol was 24.4% lower (23.1 mGy vs 30.6 mGy, p < 0.0001) and DLP and ED reductions were 35.6% than with MDCT (465.0 mGy * cm vs 732.3 mGy * cm and 6.5 mSv and 10.3 mSv; vs p < 0.0001). Concerning scan parameters, kVp and ET reductions were 12.7% and 69.4%, respectively (p < 0.0001); PF increase was 73.8% (p < 0.0001). In all vascular studies, DSCT, compared with MDCT, permitted to reduce CTDIvol from 43.5 to 70.6%; DLP and ED reductions were from 50.3 to 73.1%; kVp and ET decreases were from 10.7 to 32.5% and from 26.3 to 68.7%. PF increase was from 16.7 to 58.1% (all differences with p < 0.0001). CONCLUSIONS: In daily practice, CV examinations CTDI, DLP, ED, ET and TV were lower and PF was higher with 192 × 2-DSCT compared to 64-MDCT.


Assuntos
Doenças Cardiovasculares/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Tomografia Computadorizada Multidetectores/métodos , Exposição à Radiação , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Angiografia por Tomografia Computadorizada/efeitos adversos , Angiografia por Tomografia Computadorizada/instrumentação , Angiografia Coronária/efeitos adversos , Angiografia Coronária/instrumentação , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Segurança de Equipamentos , Humanos , Tomografia Computadorizada Multidetectores/efeitos adversos , Tomografia Computadorizada Multidetectores/instrumentação , Doses de Radiação , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/efeitos adversos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/instrumentação , Estudos Retrospectivos , Fatores de Tempo
6.
Radiol Med ; 124(8): 745-752, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31004322

RESUMO

AIM: To provide an overview on dose reduction and image quality after the installation of a third-generation dual-source CT (dsCT) in a Pediatric Radiology Department. MATERIALS AND METHODS: We included pediatric patients (< 20 years old) undergoing CT for oncological staging (neck, chest and abdomen) or low-dose chest CT for lung diseases. Each of these two groups were further divided in two age groups (≤ or > 10 years old) including patients scanned in the same period of two consecutive years, in 2017 with a 16-row LightSpeed CT (GE Healthcare) or in 2018 with a Somatom Force dsCT (Siemens Healthineers). Technical parameters such as kVp, mAs, slice thickness, exposure times and dose indicators were retrieved and compared. Image quality was evaluated in consensus by two radiologists on a five-point semiquantitative scale. Nonparametric tests were used. RESULTS: In oncological patients, significantly lower kVp and tube current with better image quality were achieved with the dsCT. Radiation dose (total DLP) was 5-6 times lower with dsCT, thanks also to virtual non-contrast images. In low-dose chest CT, the frequent use of tin filter required higher tube current; a total DLP 3 times lower was achieved with dsCT in patients ≤ 10 years old. The image quality was better with the dsCT in low-dose chest CT protocols. CONCLUSION: The third-generation dsCT provides high-quality images with reduced motion artifacts at lower dose.


Assuntos
Pneumopatias/diagnóstico por imagem , Tomografia Computadorizada Multidetectores/normas , Tomografia Computadorizada Multidetectores/tendências , Neoplasias/diagnóstico por imagem , Doses de Radiação , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Adolescente , Fatores Etários , Artefatos , Criança , Feminino , Humanos , Masculino , Tomografia Computadorizada Multidetectores/instrumentação , Movimentos dos Órgãos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/instrumentação , Radiografia Torácica/normas , Radiografia Torácica/tendências , Adulto Jovem
7.
Radiol Med ; 120(5): 466-73, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25412816

RESUMO

PURPOSE: This study was done to evaluate the appropriateness of dose indices in computed tomography (CT) by comparing the body computed tomography dose index (CTDI) and the size-specific dose estimates (SSDE) to determine which of these two parameters is more appropriate to estimate the radiation dose to both adult and paediatric patients. MATERIALS AND METHODS: We analysed 150 thoracic CT and 150 abdominal CT scans, half of which from adult patients and the other half from paediatric patients. We compared the values of the CTDIvol and the SSDE reporting the average, maximum and minimum percentage difference for each body region and depending on the age of the patients. RESULTS: In the thoracic CT and abdominal CT scans, we found values of difference between the SSDE and the CTDIvol of 26.3 and 27.3 %, respectively, in adult patients and of 46.9 and 48.5 % in paediatric patients. CONCLUSIONS: The SSDE is a good tool for estimating the average radiation dose for a given patient depending on the input parameters and the dimensions of the specific person in question before a CT examination.


Assuntos
Doses de Radiação , Radiometria/métodos , Tomografia Computadorizada Espiral/métodos , Adolescente , Carga Corporal (Radioterapia) , Criança , Pré-Escolar , Humanos , Lactente , Recém-Nascido , Imagens de Fantasmas , Software
8.
Clin Chem Lab Med ; 52(10): 1507-11, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24914727

RESUMO

BACKGROUND: Urinary tract infections (UTIs) are among the most common infectious diseases. RESULTS obtained from conventional microbiological analysis of urine and antibiotic susceptibility testing are available only after a few days, delaying precise diagnosis and appropriate therapy. Micro Biological Survey (MBS) srl (a spin-off of Roma Tre University, Rome, Italy) has developed and patented an automated colorimetric test for rapid bacterial counting. In a preliminary validation study it was demonstrated that the results obtained with the MBS method are equivalent to the results obtained with conventional culture-based microbiological analysis. METHODS: In this study, sterile urine samples were artificially contaminated with bacterial species that are most frequently responsible for UTIs. The MBS method was used to evaluate the presence of bacteria and their sensitivity to some of the most commonly used antibiotics in UTIs. RESULTS: The MBS method was able to detect in a few hours the presence or absence of bacteria at clinically significant concentrations (>105 CFU/mL), and to provide their susceptibility pattern to a limited panel of antibiotics. DISCUSSION: The results obtained demonstrate that the MBS point-of-care testing (POCT) device could be developed into a valuable aid for the management of UTIs, possibly addressing more precise diagnosis and appropriate therapy.


Assuntos
Carga Bacteriana/instrumentação , Infecções Urinárias/diagnóstico , Infecções Urinárias/microbiologia , Antibacterianos/uso terapêutico , Sistemas Automatizados de Assistência Junto ao Leito , Fatores de Tempo , Infecções Urinárias/tratamento farmacológico , Infecções Urinárias/urina
9.
J Dairy Sci ; 97(1): 46-55, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24239081

RESUMO

Dairy products are characterized by reduced shelf life because they are an excellent growth medium for a wide range of microorganisms. For this reason, it is important to monitor the microbiological quality of dairy products and, in particular, the total viable count and concentration of Escherichia coli, as they are indicators of the hygienic state of these products. In addition, in dairy products such as Mozzarella cheese, it is important to monitor the concentration of lactic acid bacteria (LAB), as they are the major components of starter cultures used in cheese production, contributing to the taste and texture of fermented products and inhibiting food spoilage bacteria by producing growth-inhibiting substances. For these reasons, to ensure the quality and safety of their products, cheese makers should monitor frequently, during fresh cheese production, the concentration of LAB and spoilage bacteria. However, usually, small- to medium-size dairy factories do not have an internal microbiological laboratory and external laboratories of analysis are often too expensive and require several days for the results. Compared with traditional methods, the microbiological survey (MBS) method developed by Roma Tre University (Rome, Italy) allows faster and less-expensive microbiological analyses to be conducted wherever they are necessary, without the need for a microbiological laboratory or any instrumentation other than MBS vials and a thermostat. In this paper, we report the primary validation of the MBS method to monitor LAB concentration in Mozzarella cheese and the analysis, using the MBS method, of total viable count, E. coli, and LAB concentrations in the production line of Mozzarella cheese as well as during the shelf life of the product stored at 20°C. The results obtained indicate that the MBS method may be successfully used by small- to medium-size dairy factories that do not have an internal microbiological laboratory. Using the MBS method, these dairy factories can monitor autonomously the microbiological safety and quality of their products, saving both time and money.


Assuntos
Queijo/microbiologia , Contaminação de Alimentos/prevenção & controle , Microbiologia de Alimentos , Qualidade dos Alimentos , Animais , Bactérias/isolamento & purificação , Queijo/análise , Contagem de Colônia Microbiana , Fermentação , Itália , Viabilidade Microbiana , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA