Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Mol Cell ; 83(12): 2020-2034.e6, 2023 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-37295429

RESUMO

Biomolecular condensation underlies the biogenesis of an expanding array of membraneless assemblies, including stress granules (SGs), which form under a variety of cellular stresses. Advances have been made in understanding the molecular grammar of a few scaffold proteins that make up these phases, but how the partitioning of hundreds of SG proteins is regulated remains largely unresolved. While investigating the rules that govern the condensation of ataxin-2, an SG protein implicated in neurodegenerative disease, we unexpectedly identified a short 14 aa sequence that acts as a condensation switch and is conserved across the eukaryote lineage. We identify poly(A)-binding proteins as unconventional RNA-dependent chaperones that control this regulatory switch. Our results uncover a hierarchy of cis and trans interactions that fine-tune ataxin-2 condensation and reveal an unexpected molecular function for ancient poly(A)-binding proteins as regulators of biomolecular condensate proteins. These findings may inspire approaches to therapeutically target aberrant phases in disease.


Assuntos
Ataxina-2 , Doenças Neurodegenerativas , Humanos , Ataxina-2/genética , Proteína I de Ligação a Poli(A) , Doenças Neurodegenerativas/metabolismo , Condensados Biomoleculares
2.
Cells ; 10(2)2021 01 22.
Artigo em Inglês | MEDLINE | ID: mdl-33499374

RESUMO

The "distal axonopathy" hypothesis in amyotrophic lateral sclerosis (ALS) proposes that pathological changes occur at the neuromuscular junction (NMJ) early in the disease. While acetylcholinesterase (AChE) plays an important role in the functionality of the NMJ, its potential role in ALS remains unexplored. Here, we identified AChE as a limiting factor regulating muscle/motor neuron connection in a vertebrate model of ALS. Knockdown of the TAR DNA-binding protein 43 (TDP-43) orthologue in zebrafish resulted in early defects of motor functions coupled with NMJ disassembly. We found that a partially depleted tdp-43 caused a decrease of ache expression. Importantly, human AChE overexpression reduced the phenotypic defects in the tdp-43 loss of function model, with amelioration of post- and pre-synaptic deficits at the NMJ. In conclusion, our results provide a better understanding of the role of TDP-43 in the NMJ organization and indicate AChE as a contributing factor in the pathology of ALS. In particular, it may be implicated in the early defects that characterize NMJs in this major neurodegenerative disorder.


Assuntos
Acetilcolinesterase/metabolismo , Esclerose Lateral Amiotrófica/metabolismo , Esclerose Lateral Amiotrófica/patologia , Proteínas de Ligação a DNA/metabolismo , Proteínas de Peixe-Zebra/metabolismo , Peixe-Zebra/metabolismo , Animais , Epistasia Genética , Técnicas de Silenciamento de Genes , Junção Neuromuscular/patologia , Fenótipo , Ligação Proteica
3.
PLoS One ; 9(6): e98852, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24911840

RESUMO

The goal of this study was to assess the effect of corneal hydration on the quality of the femtosecond laser (FSL) anterior lamellar cut. The Visumax FSL was used to dissect an 8-mm-diameter corneal flap in 22 eye bank corneas showing various levels of hydration. The intended ablation depth was 220 µm in all eyes, which corresponded to the maximal depth available with this laser. After the cut, the achieved ablation depth was measured using optical coherence tomography images, flap separability was assessed by measuring the mean force generated to detach the flap, and stromal bed roughness was assessed by measuring the Haralick contrast level on the 1000× scanning electron microscopy images of the ablated surfaces. The preoperative central corneal thickness ranged from 547 to 1104 µm (mean ± SEM: 833 ± 30 µm). A negative correlation was found between the level of corneal hydration and the ablation depth measured in the mid-peripheral cornea (r =  -0.626, p = 0.003), the ablation being more superficial in more edematous corneas. The Haralick contrast also tended to increase as a function of corneal hydration (r = 0.416, p = 0.061), suggesting that laser ablation in edematous corneas results in rougher stromal surfaces. These results support the hypothesis that the quality of the FSL lamellar cut decreases as the level of corneal hydration increases. Although FSL is still considered in the field as the tool of the future for corneal dissection, a better understanding of the limits of this tool will be needed before it can replace manual or automated stromal dissection techniques in hydrated corneas.


Assuntos
Córnea/metabolismo , Córnea/cirurgia , Cirurgia da Córnea a Laser/métodos , Terapia a Laser/métodos , Substância Própria/metabolismo , Substância Própria/cirurgia , Cirurgia da Córnea a Laser/efeitos adversos , Humanos , Terapia a Laser/efeitos adversos , Retalhos Cirúrgicos , Resultado do Tratamento
4.
J Cataract Refract Surg ; 39(1): 118-127, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23128030

RESUMO

PURPOSE: To assess the accuracy of the scanning electron microscopy (SEM) and present alternative approaches to quantify surface roughness based on numerical analysis. SETTING: Department of Ophthalmology, Maisonneuve-Rosemont Hospital, University of Montreal, Montreal, Quebec, Canada. DESIGN: Experimental study. METHODS: Lamellar stromal cuts were performed on human corneas using a femtosecond laser or a microkeratome. The photodisrupted stromal surfaces were processed for SEM, and images were acquired at ×1000 magnification. First, images were evaluated by independent observers. Second, images were analyzed based on first-order and second-order statistics of gray-level intensities. Third, 3-dimensional (3-D) surface reconstructions were generated from pairs of SEM images acquired at 2 angles. RESULTS: Results show that traditional assessment of roughness based on evaluating SEM images by independent observers can be replaced by computer-image texture analysis; an algorithm was developed to avoid subjective and time-consuming observations. The 3-D reconstructions allowed additional characterization of surface properties that was not possible with SEM images alone. Significant fluctuations in surface height were lost, although they could be retrieved using 3-D reconstructions. CONCLUSIONS: Image texture analysis allowed objective and repeatable assessment of stromal surface roughness; however, full assessments of surface-height fluctuations required 3-D reconstruction. These complementary methodologies offer a more comprehensive assessment of corneal surface roughness in clinical applications.


Assuntos
Substância Própria/cirurgia , Substância Própria/ultraestrutura , Terapia a Laser , Microscopia Eletrônica de Varredura , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Propriedades de Superfície , Doadores de Tecidos
5.
Opt Lett ; 32(16): 2456-8, 2007 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-17700817

RESUMO

We present here a three-dimensional evaluation of the amplitude point-spread function (APSF) of a microscope objective (MO), based on a single holographic acquisition of its pupil wavefront. The aberration function is extracted from this pupil measurements and then inserted in a scalar model of diffraction, allowing one to calculate the distribution of the complex wavefront propagated around the focal point. The accuracy of the results is compared with a direct measurement of the APSF with a second holographic system located in the image plane of the MO. Measurements on a 100 x 1.3 NA MO are presented.

6.
J Opt Soc Am A Opt Image Sci Vis ; 23(12): 3177-90, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17106474

RESUMO

The concept of numerical parametric lenses (NPL) is introduced to achieve wavefront reconstruction in digital holography. It is shown that operations usually performed by optical components and described in ray geometrical optics, such as image shifting, magnification, and especially complete aberration compensation (phase aberrations and image distortion), can be mimicked by numerical computation of a NPL. Furthermore, we demonstrate that automatic one-dimensional or two-dimensional fitting procedures allow adjustment of the NPL parameters as expressed in terms of standard or Zernike polynomial coefficients. These coefficients can provide a quantitative evaluation of the aberrations generated by the specimen. Demonstration is given of the reconstruction of the topology of a microlens.


Assuntos
Artefatos , Holografia/instrumentação , Aumento da Imagem/instrumentação , Interpretação de Imagem Assistida por Computador/métodos , Lentes , Microscopia/instrumentação , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Análise Numérica Assistida por Computador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
Opt Lett ; 31(2): 178-80, 2006 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-16441022

RESUMO

For what we believe to be the first time, digital holographic microscopy is applied to perform optical diffraction tomography of a pollen grain. Transmission phase images with nanometric axial accuracy are numerically reconstructed from holograms acquired for different orientations of the rotating sample; then the three-dimensional refractive index spatial distribution is computed by inverse radon transform. A precision of 0.01 for the refractive index estimation and a spatial resolution in the micrometer range are demonstrated.


Assuntos
Holografia/métodos , Imageamento Tridimensional/métodos , Microscopia/métodos , Pólen/ultraestrutura , Refratometria/métodos , Processamento de Sinais Assistido por Computador , Tomografia Óptica/métodos , Algoritmos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA